Teledyne Advanced Pollution Instrumentation
Teledyne API (TAPI) designs and builds precision air quality and industrial gas monitoring instrumentation at our factory located in San Diego, California, USA. Our products are used worldwide in ambient air quality monitoring systems (AQMS), continuous emissions monitoring systems (CEMS), and industrial process applications.
- (858) 657-9800
- (858) 657-9818
- api-sales@teledyne.com
- 9970 Carroll Canyon Road
CA, San Diego 92131
United States of America
Categories
-
product
Paramagnetic O2 Analyzer Optional CO2 Sensor
Model T802
Teledyne Advanced Pollution Instrumentation
The Model T802 O2 uses the proven paramagnetic measurement principle, coupled with state of the art microprocessor technology, to provide accurate and dependable measurements of Percent-Level O2.Paramagnetic technology is non-depleting, which means that there are no consumable parts, and ensures a consistent performance over time. The selectivity of the paramagnetic measurement for oxygen means that there is little or no interference from other common background gases. The T802 offers a stable and inherently linear measurement of oxygen, making it possible to calibrate the analyzer by checking only two points. There is no requirement for a reference gas during operation.
-
product
UV Absorption O3 Analyzer
Model T400
Teledyne Advanced Pollution Instrumentation
The Model T400 UV Absorption analyzer uses a system based on the Beer-Lambert law for measuring low ranges of ozone in ambient air.A 254 nm UV light signal is passed through the sample cell where it is absorbed in proportion to the amount of ozone present. Periodically, a switching valve alternates measurement between the sample stream and a sample that has been scrubbed of ozone. The result is a true, stable ozone measurement.
-
product
Mid-Range Chemiluminescence NOX-NO2-NO Analyzer
Model N200M
Teledyne Advanced Pollution Instrumentation
The Model N200M uses the proven chemiluminescence detection principle, combined with a state-of-the-art modular architecture, and intuitive operating software to provide accurate and dependable measurements of Nitric Oxide (NO), Nitrogen Dioxide (NO2) and total Nitrogen Oxides (NOx) gases for use in extractive type CEM systems.
-
product
Photometric Ozone Calibrator
Model T703
Teledyne Advanced Pollution Instrumentation
The Model T703 is a microprocessor controlled ozone calibrator for precision gas analyzers. The Model T703 can deliver concentrations from 50 ppb to 5 ppm at flows from 1 LPM to 5 LPM.The Model T703 has two major components; the ozone generating device and the photometer. The ozone generator produces ozone by passing zero air over a UV lamp. Flow rate and lamp intensity are adjusted to deliver a specified ozone concentration by volume. The temperate and pressure compensated photometer, identical to that of the Model T400 ozone analyzer, provides feedback control of the UV lamp intensity, assuring stable ozone output. A nearly unlimited number of calibration sequences may be programmed into the non-volatile memory of the T703, covering time periods up to a year.
-
product
Single/Multi-Channel Industrial Safety Ozone Monitor
Model 465L
Teledyne Advanced Pollution Instrumentation
The Model 465L UV Photometric Ozone Monitor is an extremely stable analyzer, ideal for critical low-level ppm safety and process applications. Its calibration is NIST traceable and the included pressure and temperature compensation ensure high accuracy under all conditions.
-
product
Catalytic Ozone Destructs
CAT-O3 Series
Teledyne Advanced Pollution Instrumentation
The CAT-O3 series of ozone destructs safely decompose high concentrations of ozone gas to sub-ppm levels that are below recommended ozone safety limits. The catalytic method of decomposition uses a metal oxide catalyst to passively convert the ozone to oxygen.
-
product
Carbon Compound Instruments
Teledyne Advanced Pollution Instrumentation
Teledyne API's Carbon compound analyzers utilize Gas Filter Correlation combined with reliable NDIR (non-dispersed infrared) technology to produce very stable and accurate gas measurements. All T Series instruments offer two front-panel USB ports, an advanced touch screen full color display, customizable user interface with predictive maintenance alerts, one-touch real-time graphing, and multiple language support. All of our instruments are designed meet the rigorous demands of ambient air quality, stack, or industrial process gas monitoring.
-
product
Trace-Level Chemiluminescence NO/NO2/NOx Analyzer
Model T200U
Teledyne Advanced Pollution Instrumentation
The Model T200U Trace-level NO/NO2/NOx analyzer has been developed specifically to address the challenges of low level monitoring as required, for example, in the US NCore network. It uses the proven chemiluminescence principle and is designed to allow ultra-sensitive measurements with a lower detectable limit of 50 ppt while still meeting the requirements for use as a US EPA compliance analyzer.The Model T200U combines a gold plated reaction cell with an enhanced performance pump, special low noise photomultiplier tube, and unique signal conditioning to provide exceptional sensitivity. In addition, a pre-reactor separates the NO-O3 reaction from background chemiluminescence to allow accurate auto-zero of the analyzer.
-
product
Mid-Range Gas Filter Correlation CO Analyzer
Model N300M
Teledyne Advanced Pollution Instrumentation
The Model N300M is a microprocessor-controlled analyzer used to determine the concentration of carbon monoxide (CO) in a sample gas. The analysis method is based on the Beer-Lambert law.The N300M uses Gas Filter Correlation (GFC) to overcome the interfering effects of various other gases (such as water vapor) that also absorb IR. The analyzer passes the IR beam through a spinning wheel made up of two separate chambers: one containing a high concentration of CO known as the reference, and the other containing a neutral gas known as the measure. The concentration of CO in the sample chamber is computed by taking the ratio of the instantaneous measure and reference values and then compensating the ratio for sample temperature and pressure.
-
product
Portable Zero Air System
Model 751H
Teledyne Advanced Pollution Instrumentation
The Model 751H is a portable, fully self-contained source of high purity zero air for dilution calibrators. It is ideal for use with sensitive analyzers in ambient background and trace level applications. Packaged in a wheeled, high density plastic case, the Model 751H provides ultra-high purity output with a warm-up time of 30 minutes.
-
product
Mid-Range Chemiluminescence NO/NO2/NOX Analyzer
Model T200M
Teledyne Advanced Pollution Instrumentation
The Model T200M combines the proven chemiluminescence principle with a number of innovative features to provide reliable and repeatable NO, NO2, and NOx measurements for extractive type CEM systems. The option of either a molybdenum converter or a high-efficiency stainless steel thermal NO2 converter allows the T200M to be used in a variety of extractive CEM systems, from gas turbines to coal-fired boilers.
-
product
Chemiluminescence NO/NO2/NOX Analyzer
Model T200
Teledyne Advanced Pollution Instrumentation
The Model T200 NO/NO2/NOx analyzer uses the proven chemiluminescence detection principle, coupled with state-of-the-art electronics to allow accurate and dependable low level measurements for use as an ambient analyzer or dilution CEMS monitor.A unique AutoZero feature provides superb stability by continuously correcting for zero drift, while advanced Adaptive Filtering allows the analyzer to optimize performance under changing conditions. The Model T200 includes a permeation inlet dryer for ozone generation to provide excellent reliability with no periodic replacement required. A catalytic exhaust ozone scrubber is standard for maximum safety and pump life.
-
product
Compact Ozone Monitor
Model 430
Teledyne Advanced Pollution Instrumentation
Teledyne API, a recognized leader in Ozone measurements, is pleased to offer the Model 430 O3 Monitor. The 430 is a compact instrument that uses the proven UV-absorption principle. The small footprint and robust design make it ideal for a variety of applications where portability and accuracy are both necessary.
-
product
Process Ozone Monitor
Model 454
Teledyne Advanced Pollution Instrumentation
The Model 454 is a microprocessor based gas monitor for measuring mid to high concentrations of ozone in oxygen or air.Available in a standard DIN panel mount configuration with a 4-digit LED display, the compact design provides ease of mounting and installation.
-
product
Trace-Level Dilution Calibrator
Model T700U
Teledyne Advanced Pollution Instrumentation
The Model T700U is a microprocessor based calibrator for precision, trace-level gas analyzers. Using highly accurate mass flow controllers combined with compressed sources of standard gases, calibration standards are provided for multipoint span and zero checks using up to 4 gas sources.In addition to the features of the Model T700, the Model T700U is designed for the demanding requirements of trace-level measurements. The ability to calibrate and verify linearity for NO2 at levels below 50 ppb is difficult with standard calibrators. To overcome this limitation, the Model T700U ozone generator operates in two modes; a high range with similar performance to the Model T700 ozone generator, and a low range, or "fractional" mode, for producing accurate ozone levels down to 3 ppb. To ensure the highest accuracy of NO2 output, the calibrator measures the ozone concentration prior to performing a GPT, and the range is selected automatically by the Model T700U based on ozone concentration and flow specified by the user.