Shimadzu Corp.
It is a leading global producer of analytical instruments, laboratory equipment, medical diagnostic systems (such as X-ray and imaging systems), and industrial machinery.
- 81-75-823-1111
- 1 Nishinokyo Kuwabara-cho
Nakagyo-ku
Kyoto, 604-8511
Japan
-
Product
SampleStation And AuraSolution: Automated Analysis Software For MALDI-8020
SampleStation and AuraSolution
-
The SampleStation and AuraSolution software link to the MALDI Solutions MALDI-8020 control and analysis software to analyze samples automatically based on a worklist.
-
Product
Energy Dispersive X-ray Fluorescence Spectrometer
Pharmaceutical Elemental Impurities Analysis System
-
Control of Elemental Impurities in Pharmaceuticals In the pharmaceutical industry, the analysis of elemental impurities is necessary to ensure the safety of pharmaceuticals. In December 2014, the "Guideline for Elemental Impurities" (Q3D) was issued by the International Council for Harmonisation of Technical Requirements for Pharmaceuticals for Human Use (ICH), consisting of representatives from Europe, the U.S. and Japan. In Japan, the "Guideline for Elemental Impurities in Drug Products" (PFSB/ELD Notification 0930 #4 from the Ministry of Health, Labour and Welfare) was issued, and will be applied to new drug products submitted for approval after April 1 2017. For 24 elements categorized in Class 1 to Class 3, residual quantities in pharmaceutical drug products must be controlled within permissible limits. Although ICP-AES and ICP-MS are used for precise analysis of elemental impurities, X-ray fluorescence spectrometers can be used as an alternative analysis method. This is because they can quantitatively and qualitatively analyze a variety of elements nondestructively, and without chemical pretreatment, unlike ICP-AES and ICP-MS systems. The X-ray fluorescence spectrometry has been adopted as a general method of analysis in the U.S Pharmacopeia and the European Pharmacopoeia. (USP<735>, Ph.Eur.2.2.37)
-
Product
Sulfur Chemiluminescence Detection Gas Chromatograph System
Nexis SCD-2030
-
The Nexis SCD-2030 is a next-generation sulfur chemiluminescence detection system. It has been developed to fulfill the unmet needs of laboratories the world over. The dramatically enhanced sensitivity and reliability, the excellent maintainability, and the automation functions, a first for the industry, will improve laboratory productivity.
-
Product
UV-VIS-NIR Spectrophotometer
SolidSpec-3700i/3700iDUV
-
The SolidSpec-3700i/3700i DUV have three detectors which cover the range from ultraviolet to near-infrared.
-
Product
Conductivity Detector
CDD-10AVP
-
Low noise, low drift and wide dynamic range assure proven performance of the Shimadzu VP series HPLC. Data acquired by the CDD-10AVP is transferred to the SCL system controller via an optical fiber interface and are digitally processed by workstation. By adding the optional cell (dual kit NS), a low-cost and compact non-suppressor type dual ion chromatograph, which detects anions and cations simultaneously, can be made.
-
Product
Static Jack System
-
The servo actuator system applies static test force loads on structures at high precision to obtain their mechanical characteristics on an experimental basis.
-
Product
Compact Tabletop Tester
EZ Test
-
This easy-to-use, compact, stylish frame incorporates enhanced functions, enabling tests to be carried out with good efficiency.
-
Product
Impurity Analysis In Bulk Gas
-
High-purity gas is necessary in industries such as chemical, medical, and foods. Precisely controlled GC enables identification and quantitation of a trace amount of impurities in bulk gas. If the gas resources in a factory consist of multiple lines, a sample line selector SLS-2020 can be utilized to switch sample lines automatically, allowing a single GC to analyze all samples.
-
Product
Differential Transformer Type Extensometers
DT Series
-
ISO Class 1 Compliant Differential Transformer Type Extensometers The ISO 6892-1 standard for tensile testing of metallic materials prescribes Class 1 or higher extensometers, and JIS Z2241 prescribes Class 2 or higher extensometers when measuring withstanding pressure. The DT series includes Class 1 compliant differential transformer type extensometers, which can be used to implement test methods compliant with metal tensile test standards.
-
Product
Transportable Gas Analyzer
CFP-8000
-
The CFP-8000 is pretreatment unit that is used with CGT-7100 or NOA-7100. When performing continuous gas analysis, dust and moisture must be removed from the gas before sending to the analyzer. This essential preprocessing can be performed by this one device, and two lines of cleaned measurement gas can be used simultaneously. Light-weight and compact, the CFP-8000 is the perfect preprocessor for use with portable analyzers.
-
Product
LC/MS/MS Method Package For Mycotoxins
-
Mycotoxins are highly toxic chemical byproducts from fungi commonly found in crops, and residual content in foods are regulated the world over. This method package provides simultaneous multi-component analysis conditions for mycotoxins subject to the regulations in Japan, the USA, the EU, and China.
-
Product
TG/DTA Simultaneous Measuring Instrument
DTG-60 Series
-
This instrument varies the sample temperature in accordancewith a program, and simultaneously measures the change inmass of the sample (TG) and the temperature differencebetween the sample and a standard substance (DTA). An analytical balance mechanism (Roberval mechanism) offers high reproducibility and allows worry-free operation even for measuring sample weights. Two models are available for different maximum measurement temperature requirements-the DTG-60 (max. 1,100 °C) and the DTG-60H (max. 1,500 °C). Corresponding DTG-60A and DTG-60AH models with a built-in autosampler are also available for measuring up to 24 samples automatically.