The HORIBA Group of worldwide companies provides an extensive array of instruments and systems for applications ranging from automotive R&D, process and environmental monitoring, in-vitro medical diagnostics, semiconductor manufacturing and metrology, to a broad range of scientific R&D and QC measurements.
- +81 75 313 8123
- +81 75 321 0752
- info@horiba.co.jp
- 2, Miyanohigashi,
Kisshoin
Minami-Ku, Kyoto 601-8510
Japan
-
Product
Plasma Emission Controller
RU-1000
-
The optical technology developed by HORIBA and the gas control technology offered by HORIBA STEC have been combined to make further advances in plasma control technology. The plasma emission controller RU-100 offers; faster deposition by controlling the transition region, optimized distribution in a large-area, high-capacity chamber, plasma stabilization in a long sputtering process (stable deposition), and mixture optimization of compounds for reactive sputtering.
-
Product
Engine Torque Pulse Simulation
ETPS
-
HORIBA has revolutionized the way vehicle manufacturers test their Powertrains and Front End Accessory Devices. The ETPS dynamometer system accurately produces torsional pulse characteristics of an engine. This new technology employs a sophisticated mathematical model to calculate the resulting torque at the output of the engine based on engine and combustion process parameters.
-
Product
Deep Cooled UV/Vis/NIR and VUV Scientific Cameras
Syncerity Scientific Cameras
-
HORIBA Scientific offers a complete line of spectroscopic multi-channel detectors for scientific research. For spectral detection from UV to near-IR, two dimensional CCDs offering a faster acquisition option over single point detectors with relatively high sensitivity. Coupled with HORIBA’s range of aberration corrected flat field imaging spectrographs, OEM packages can be assembled for a variety of applications.
-
Product
Process Laser Gas Analyzer
PLGA-1000
-
The PLGA-1000 Process Laser Gas Analyzer is designed to measure hydrocarbons and other gases contained in process gases at petrochemical plants. The PLGA-1000 uses proprietary technology to measure low concentrations of acetylene (C2H2) and carbon dioxide (CO2) contained as impurities in high concentration methane (CH4) and ethane (C2H6) which are material gases, continuously at high speed and with high sensitivity . This contributes to improvements in productivity, cost, and quality in the manufacturing process, as well as reducing environmental impact.
-
Product
Field-installation Type Residual Chlorine Meter (Four-Wire Transmission, Rotating Type)
HR-200RT
-
HR-200RT is connected to a residual chlorine sensor (RA-30), which allows the free residual chlorine concentration to be measured with high accuracy. It is sutable for waterworks, pool water sterilization, and desalination systems. The measurement method is a three-pole polarographic method, which enables continuous monitoring of residual chlorine concentrations without using reagents.Stable measurement over a long period was realized by physical polishing cleaning using beads.
-
Product
pH Pocket Water Meter
LAQUAtwin pH-11
-
The only pocket meter that directly measures pH in 0.1ml sample (or 0.05ml sample with sampling sheet B). Unique sensor allows measurement of viscous liquids, solids, and even powder samples. No need for a beaker to calibrate your meter or measure a sample. Just place few drops of the standard or sample onto the flat sensor. This procedure saves you time and prevents wasting your precious sample.
-
Product
AFM-Raman for Physical and Chemical Imaging
XploRA Nano
-
Fully integrated system based on SmartSPM state of the art scanning probe microscope and XploRA Raman micro-spectrometer.Compact, fully automated and easy-to-use, the XploRA Nano concentrates the power of AFM-Raman into an affordable yet full-featured package, making TERS imaging a reality for all. The TERS proven system.
-
Product
2-Channel Resistivity Meter
HE-960RW-GC(W)
-
The HE-960RW-GC(W) is a 2-channel simultaneous-measurement carbon sensor, resistivity meter that can be connected with two sensors. The measurement range is: 0 - 100.0 MΩ・cm.The high performance and high precision is maintained while simultaneously measuring the output of the resistivity of different two locations. This is carried out in a single converter for overall cost efficient performance.
-
Product
Stack Gas Analysis System
ENDA-5000 series
-
Continuous simultaneous and high-precision measurement of NOx, SO2, CO, CO2 and O2.HORIBA has over 100,000 CEM systems installed and 30 years of quality and experience. That is the base on which HORIBA's new ENDA-5000 series of stack-gas analysis systems are built. These systems have a small footprint and use cross-flow modulated non-dispersive infrared (NDIR) and magneto-pneumatic detectors that are inherently drift-free. The ENDA-5000 series are superior continuous analysis systems that perform reliably for difficult exhaust gas measurements, when measurement errors cannot be tolerated. This CEM series features a new intuitive touch panel that makes every operation available with the touch of a single button. The ENDA-5000 series systems are also designed for ease of maintenance. They are ideal for a variety of uses, including emissions monitoring from steam boilers, refuse incinerators, and electric power generation plants to assure pollution standards are being met.
-
Product
Panel-mount Type pH Meter (Four-Wire Transmission, Industrial Time sharing Proportional Control)
HP-480TP
-
HP-480 connects pH sensor and measures pH and temperature in the sample water. Suitable for monitoring and control of various production processes and wastewater treatment, etc. Many types of electrodes are available to match the sample properties.HP-480TP is a pH meter with a time sharing proportional control function, making it ideal for tasks such as interval processing in any type of control process.
-
Product
Test Stand Controller for Automotive, Marine, and Aerospace Engine Testing
SPARC
-
The new SPARC Engine is the state-of-the-art test stand controller for automotive, marine and aerospace engine testing. The latest generation offers you advanced hardware and software for the highest performance, and touch functionality for intuitive operation. It is suitable for test stands with a synchronous machine (DYNASPM), asynchronous machine (DYNAS3), hydraulic dynamometer (DT) and eddy current dynamometer (WT) as well as tandem applications.
-
Product
Panel-mount Type Dissolved Oxygen Meter (Four-Wire Transmission, Membrane Type)
HD-480
-
The HD-480 industrial dissolved oxygen meter takes sequential measurements of the concentration of dissolved oxygen, which is an indicator used in the management of activated sludge tanks in waste water processing, and the quality of the water in boilers, or rivers and waterways.As there is no need to exchange the membrane of the disposable sensor included, it is easy for anyone to use.
-
Product
TCSPC Lifetime Kit
DeltaTime
-
The DeltaTime time correlated single photon counting (TCSPC) lifetime plug-in offers acquisition speed, flexibility, and affordability unavailable in any other multifunctioanl fluorescence solution on the market. DeltaTime seamlessly integrates monochromators, polarizers, and other accessories with the widest array of sources (LEDs, laser diodes, supercontinuum lasers) and detectors (including NIR), providing lifetime coverage from 25ps to 1sec over wavelengths spanning the UV to NIR.
-
Product
Hematology Analyzer
Yumizen H Range
-
an automated medical instrument that performs automated counts and analysis of blood cells, including red blood cells, white blood cells, and platelets
-
Product
Camera Endpoint Monitor based on Real Time Laser Interferometry
LEM Series
-
Our Real Time Interferometric Process Monitor provides high precision detection of film thickness and trench depth during the etching/deposition process.Depending on applications, LEM camera includes a 670 or 905 or 980 nm laser and when mounted on any dry etch/deposition process chamber with a direct top view of the wafer this generates a small laser spot on the sample surface.Interference occurs when monochromatic light hits the sample surface, resulting in different optical path lengths due to film thickness and height variations in the film.This allows the etch/deposition rate and thus thickness to be monitored in real time, also fringes counting or more complex analysis, providing enhanced process control Endpoint for a wide variety of processes. Additionally interfaces can be detected by their change in reflectivity.