National RF, Inc
National RF Inc offers State of the Art Radio Frequency and Unique Electronic Devices
- 858-565-1319
- 858-571-5909
- 7969 Engineer Road
Ste. 102
San Diego, CA 92111
-
Product
Reference Antennas
Type NRD
-
Reference antennas are precision dipole antennas that offer a fixed 2.15 dB of gain over an isotropic antenna along the major lobe axis at specified frequencies (2.15 dBi). They are intended to be used for antenna field pattern and gain measurements, or general RF sensing in the laboratory.
-
Product
Low Frequency Active Antenna And Amplifier
Type NLF-2
-
A Hot, Active, Noise Reducing Antenna System that will sit on your desk and copy 2200, 1700, and 600 through 160 Meter Experimental and Amateur Radio Signals!
-
Product
Attenuators
-
The National RF line of attenuators are compact, affordable attenuators which are ideal for insertion between a direction finding antenna and a receiver/transceiver, to aid in the DF process. In addition, they may be used in the laboratory for a low-power, in-line attenuation purposes. The affordable price is achieved by utilizing standard 5% tolerance resistors and commercial hardware. For laboratory purposes, an attenuation versus frequency curve (to 500mMHz) is provided.
-
Product
RF Proximity Detector
Type RPD-2 AND Type RPD-2A
-
The Type RPD-2 Radio Frequency (RF) Proximity Detector is designed to detect and locate devices that radiate radio waves in the high frequency to low microwave frequency range. Such devices often include surveillance and “spy” equipment. The Type RPD-2, when used with the different sensors, will detect the emanation of the radio wave within a confined area, and then isolate its location to within approximately a square foot. The type RPD-2A may be used as an RF field strength indicator for antenna field strength measurements. The RPD-2A is identical in function except that the meter scale is calibrated in relative dB units.
-
Product
Resonance Dip Meter
NRM-2
-
National RF’s Resonance Dip Meter is a test instrument used to determine the resonant frequency of a tuned circuit or resonant network, such as an antenna system. In addition, the unit may function as an RF detector, or a secondary frequency source. The instrument is analogous to the older vacuum tube “grid dip meter,” once popular in every electronic laboratory or radio station. Unique to this updated version is a buffered output that may drive a digital frequency counter for exact measurement of resonant frequency, or connected to an oscilloscope to be used as an RF detector and waveform/modulation monitor.
-
Product
Precision Dials
HROII-PD and HROII-PDA
-
National RF’s HROII-PD and PDA precision dials were inspired by the earlier National Radio Company’s famous HRO series of communications receivers. This earlier equipment incorporated a ten turn dial with a rotating number plate on the inside. Every 72 degrees of rotation, a new number appears in a rectangular cutout in the dial skirt. The numbers count from 0 to 500 in decade intervals. The HROII-PD and PDA duplicate this counting action but in a smaller diameter assembly than the earlier dial.
-
Product
VECTOR-GUN HANDHELD DIRECTION FINDING ANTENNA SYSTEM
HFDF
-
National RF's Type HFDF active directional antenna system consists of a high gain RF amplifier coupled to a tunable Faraday shielded loop antenna. Several loop antenna assemblies are available to provide coverage of frequencies in the HF and low VHF spectrum. Due to the nature of a Faraday shielded loop, the antenna exhibits a sharp null through the diametric center of the loop. This null is used to determine the direction of incoming radio signals or to locate electrical noise being radiated from some source. The internal high gain amplifier is used to compensate for the inherent inefficiency of the actual loop at the operating frequency. Overall, the system dynamic response is about +6 dB as compared to the dynamic response of a dipole. To aid in the direction finding process on strong signals, an internal 30 DB attenuator is provided. As the loop antenna presents a bi-directional response, tri-angulation may be required to eliminate the ambiguous signal direction. The line of site of the incoming signal is determined by listening for a signal null on the receiver or by watching the receiver’s S-meter.
-
Product
Vector Finders with InternalAttenuators
VF-145 LA AND VF-145 LMA
-
The VF-145 LA and LMA models are functionally the same as the VF-145 L and LM on both electrical performance and mechanical specifications. However, the LA and LMA models include an internal PIN diode attenuator that provides up to 12 dB of attenuation (measured at 150 MHz, attenuation decrease slightly as operating frequency increases) to the incoming radio signal. This attenuation occurs after the signal is received by the unit and phase shifted for processing, but before it is placed on the coax feedline to the receiver. In addition, the PIN diode utilized will absorb short burst of RF should transceivers be keyed accidentally by the user. This feature aids in very strong signal DF operations but will not totally guarantee against system overload under very strong RF emissions.








