BAUR
The BAUR testing and measurement technology prevents damage to networks and systems, allows for accurate planning of investments for maintenance and locates faults as precisely and quickly as possible. For the reliability of your networks and systems.
- +43 5522 49410
- +43 5522 49413
- headoffice@baur.eu
- Raiffeisenstraße 8
Sulz, 6832
Austria
-
Product
Cable Fault Location System
Syscompact 2000 M Pro
-
Cable fault location system 2000 M pro. The portable BAUR Syscompact 2000 M pro cable fault location system is used for cable fault location and cable testing in low- and medium-voltage cables up to 65 km length.* Fully integrated proven cable fault pre-location methods* Surge mode for acoustic pin-pointing* Easily transportable* Ideal for locations that are difficult to access
-
Product
Report Manager
-
External USB interface for BAUR oil testers. BAUR Report Manager, the external USB interface for oil testers, is used to automatically export measurement logs from BAUR oil testers to a USB drive. Extensive language support and the integration of customised logos simplify professional reporting.
-
Product
Insulating Oil Testing
-
Insulating materials are the elixir of life of electrical equipment. These materials lose their insulating and cooling properties due to impuri ties and ageing. This damages equipment, causes failures and is consequently often accompanied by high costs. Precise and reliable measurement results.
-
Product
Pin-Pointing System
Protrac®
-
As precise as pre-location is, it will never be able to recognise the deviations of a cable route in the ground. These can only be detected by precise pin-pointing. With its protrac®, BAUR offers different solutions that combine acoustic and electro-magnetic cable fault pin-pointing, sheath fault location and tracing in a single system.
-
Product
Cable Test Van
Titron
-
Automatic cable test van. The BAUR titron is a new automatic cable test van designed for cable fault location and cable testing. The new generation of the high-performance cable test van is based on state-of-the-art technology and provides effi cient, safe and reliable cable fault location and cable testing.* New intuitive operational concept* Central, automatic system control* Top reliability and quality standard* Flexible in terms of technology and equipment
-
Product
Burn Down Transformer
ATG 2
-
Cable fault location with the BAUR ATG 2. The ATG 2 burn down transformer is used for impedance reduction of cable faults in low- and medium-voltage networks. The short-circuit proof 2300 VA stray field transformer delivers a maximum voltage of 10 kV and is housed in a fully enclosed 19" housing.* Portable device for changing the fault resistance* Useful for cables that are difficult to access* Proven methods for complicated faults* Independent current and voltage control on each burning level
-
Product
Search Receiver
KMF 1
-
Cable fault location with the BAUR KMF 1. The KMF 1 search receiver is used according to the step voltage method. The cable line is scanned with two measurement probes that can be dismantled during transport. The battery-operated device is also suitable for locating multiple consecutive sheath faults.* Battery mode* Zero point compensation* accurate location of cable sheath faults* battery test
-
Product
Oil Breakdown Voltage Tester
DPA 75 C
-
Insulating oil testing with the BAUR DPA 75C. The BAUR DPA 75C oil tester developed especially for mobile use in the field is one of its kind in the market due to its functionality and excellent user benefits in comparison to the costs. The BAUR DPA 75C delivers clear and reliable measurement results.
-
Product
VLF Testing and Diagnostics Unit
Frida TD
-
Cable testing and diagnostics with the BAUR frida TD. The portable and high performance high-voltage testing and diagnostics device is available in two different configurations: frida: Used for cable and cable sheath testing of medium-voltage cables and electrical equipment up to 20 kV. Another function is insulation testing on electrical equipment.frida TD: Expands the functional scope of frida with the tan delta diagnostics and Monitored Withstand Test (MWT) that combines the cable testing and dissipation factor measurement. This allows for an accurate and comprehensive assessment of the cable condition.* Cable testing and dissipation factor diagnostics in one device* Easy and quick test setup* Automatic testing and diagnostic sequences* Compact dimensions and lightweight
-
Product
Time Domain Reflectometer
TDR 500
-
Handheld Time Domain Reflectometer. The handheld time domain reflectometer TDR 500 and TDR 510 are used for fault location in all metal cables such as power cables, coaxial cables, data cables and communication cables.* Configurable for various measurement ranges and cable types* Standard-compliant, safe measurements on life cables through the measurement category CAT IV / 600 V (with separation filter)* Ideal for fault location in the area of telecommunication, video technology, data and security technology
-
Product
Cable Test Van
BAUR Transcable 4000/S 32-3
-
Transcable 4000/S 32-3. Thetranscable 4000/S 32-3 cable test van is a 32 kV cable fault location system in 3-phase version. The system is controlled with the MGS semi-automatic control unit. The high voltage switch unit is maintenance-free and fully safe to touch.
-
Product
Mobile Cable Fault Location System
BAUR Syscompact 4000
-
Fault location with Syscompact 4000. The Syscompact 4000 is a compact, fully enclosed fault location system for pre-location and pinpointing of high-resistive, low-resistive and intermittent faults on low- and medium-voltage cables. Easy operation and the use of latest fault location methods enable fast and safe fault location.* Location of low-resistive, high-resistive and intermittent cable faults* Efficient cable fault pre-location methods* Pinpointing according to the noise location method or acoustic propagation time measurement* (with Universal Locator and ground microphone)* Sheath fault location according to the step voltage method (with Universal Locator and two measurement probes)* Easy to handle
-
Product
Time Domain Reflectometer
BAUR TDR 510
-
Handheld Time Domain Reflectometer TDR 510. The BAUR handheld time domain reflectometer TDR 510 is used for fault location in all metal cables such as power cables, coaxial cables, data cables and communication cables. The BAUR TDR 510 comes with a device storage for 50 measurements and the option to compare the trace of an active TDR measurement with a stored trace.* Configurable for various measurement ranges and cable types* Standard-compliant, safe measurements on live cables through the measurement category CAT IV / 600 V* Ideal for fault location in the area of telecommunication, video technology, data and security technology
-
Product
Surge Voltage Generator
SSG 3000
-
Cable fault location with the BAUR SSG 3000. Surge voltage generators are used for pre-location and pinpointing of high- and low-resistive as well as intermittent faults in power cables. The energy stored in a high-voltage capacitor is released at regular intervals or as DC voltage. The thus generated acoustic signal at the fault position can be recorded with a ground microphone and a universal receiver.* High surge voltage up to 32 kV* Continuously adjustable voltage* Voltage monitoring through kV meters with 3 measuring ranges* high surge energy in each voltage range
-
Product
VLF Diagnostics System
PHG 70 TD
-
Cable testing and diagnostics with the BAUR PHG 70 TD. The combination of the PHG 70 programmable test generator with the BAUR dissipation factor measurement system produces the cable testing and diagnostics system PHG TD. It is operated via PC control. Dissipation factor measurement and diagnostic testing sequences can be programmed in the menu, after which the dissipation factor measured values are automatically determined in various voltage steps and a final evaluation is conducted.* Biggest dynamic range of tan delta measured values from 1 to 10-4 with a cable capacitance >10 nF to 20 uF* High resolution +/- 1x10-5 applicable even in new PE/XLPE cables* Insensitive against interferences due to complete mains separation* Lowest time required for assessing a medium-voltage cable (3-phase approx. 1 hour)