Langer EMV-Technik GmbH
Langer EMV-Technik GmbH is a medium-sized electro-technical company which is active in the field of electromagnetic compatibility-related
- +1 888 687 5 687
+49 (0) 351 430093-0 - +49 (0) 351 430093-22
- mail@langer-emv.de
- sales@langer-emv.de
- Nöthnitzer Hang 31
Bannewitz, D-01728
Germany
-
Product
Near Field Micro Probes ICR HH H Field
-
The measuring coil is horizontally located in the probe head. The near field micro probes are operated with a positioning system (Langer Scanner).
-
Product
Scanner Probe
RFS set
-
The RFS set consits of three passive near field probes designed for the use in a measurement scanner during the development of E-field and magnetic field. They are designed for frequency ranges of 30 MHz to 3 GHz. The probe heads of the RFS set allow for close measurements needed to correctly localize interference sources on an electronic assembly.
-
Product
Immunity
RF coupling
-
is used for the conducted measurement of the immunity according to IEC 62132-4.
-
Product
Near Field Microprobe E-field 7 MHz to 3 GHz
ICR E150
-
The near field microprobe is used to measure electric fields at extremely high resolution and sensitivity. The optimal distance to the object being measured is < 1 mm. Due to its small probe head dimension, the probe has to be moved by a manual or automatic positioning system, e.g. Langer-Scanner.
-
Product
Mini Burst Field Generators
-
Mini burst field generators are small and handy burst generators used to detect weak spots in the device under test.
-
Product
MP CI set
-
The MP CI set up to measure coupling impedance is used to determine EMC characteristics of connectors and cables. The coupling inductivity defines the coupling inductance of external disturbance on the shield or on the ground with the desired signals. If the coupling inductivity is considered in the construction set-up and the pin or wire assignment of connectors or cables, then the connectors or cables will be more interference-resistant. The MP CI set-up for measuring coupling impedance can be used for following measurements at connectors or cables: 1. measurement of a single signal (common mode) 2. measurement of a symmetrical signal (common mode) 3. measurement of a symmetrical signal (differential mode)
-
Product
Near Field Probes 30 MHz - 6 GHz
XF Family
-
The XF family consists of 4 passive magnetic field probes and 3 passive E field probes designed for measuring magnetic and E-fields in ranges from 30 MHz to 6 GHz during the development phase. Due to their integrated impendance matching the probes are less sensitive in the lower frequency range than the RF type probes.
-
Product
MP field sources calibration set
-
The MP field source calibration set is used to measure electric or magnetic fields in a frequency range up to 3 GHz. RF fields or transient fields can be measured. The MP field source calibration set is used to check fields of the Langer EMV-Technik GmbH field sources, fields of TEM cells and IC striplines.