Validyne Engineering
A leading manufacturer of pressure transducers, pressure transmitters, signal conditioning in rack mount format and in portable units for field testing, and data acquisition systems with expandable chassis designs as well as PC based products for industrial and laboratory testing applications.
- (818) 886-8488
- (818) 886-6512
- sales@validyne.com
- 8626 Wilbur Avenue
Los Angeles, CA 91324
United States of America
-
Product
Variable Reluctance Pressure Sensor with All-Welded Construction
DP10
-
The DP10 Pressure Sensor, is designed for low and medium pressure measurements, to laboratory accuracy, of corrosive liquids and gases. In typical AC excited bridge circuits, this transducer delivers a full scale output of 30 mV per volt at 3kHz. The unit operates with carrier system including the Validyne CD15 since wave carrier demodulator and CD16 miniature DC input DC output carrier demodulator.
-
Product
Ruggedized Pressure Transducer
P24
-
The P24 Differential Pressure Transducer is the combination of a variable reluctance pressure transducer and a miniature carrier demodulator integrated into a single package to provide for operation from mobile dc power and deliver a standardized dc output suitable for recording or telemetry.
-
Product
HVAC Pressure Transmitter
DP850/851
-
The DP850/851 transmitters are designed for low pressure measurement in HVAC applications. The DP850 is available in full scale pressure ranges as low as 0.25 inH2O and the DP851 can be ranged to 0.025 inH2O full scale. Both models are available in 4-20 mA or 0 to +5 Vdc signal output options.
-
Product
Digital Panel Mount Manometer
PS409
-
The PS409 self-contained digital indicator and pressure sensor is ideally suited for test panels in industrial and laboratory applications where accurate low-Pressure readings are required.
-
Product
Wet-Wet Differential Pressure Sensor
DP303
-
The DP303 features "take-apart" construction enabling the user to easily disassemble the unit for cleaning or to change full scale range by exchanging the sensing diaphragm. As noted from the Pressure Range/Diaphragm Selection Chart on the reverse side of this Data Sheet, a family of interchangeable diaphragms are available to cover virtually any full scale pressure range from 0.08 psid full scale to 5,000 psid full scale-all rated for operation at 5,000 psig line pressure!
-
Product
Pressure Transducers with USB Interface
P61
-
The Validyne model P61 is a digital differential pressure transmitter designed for industrial pressure measurement applications. The on-board microprocessor provides high accuracy and improved stability in changing thermal environments. Communication and power via USB interface provides remote zero and span adjustment as well as digital pressure readings in engineering units. Drivers and software for the USB interface are included.
-
Product
Single-Channel DC Powered Carrier Demodulator
CD16
-
The CD16 Miniature Carrier Demodulator is designed to deliver a 0 to 5 Vdc output from a variable reluctance transducer and operate from unregulated 9 to 55 Vdc power. A square wave excitation of 5 kHz is furnished to the transducer and the solid state integrated circuit amplifier and demodulator converts the transducer signal to an analog dc output. Zero and Span adjustments are made through access holes in the case.
-
Product
Variable Reluctance Absolute Pressure Sensor
AP10
-
The AP10, Absolute Pressure Sensor, is designed for low and medium pressure measurements, to laboratory accuracy, of corrosive liquids and gases. In typical AC excited bridge circuits, this transducer delivers a full-scale output of 40 mV per volt at 3kHz. The unit operates with carrier systems including the Validyne CD15 sine wave carrier demodulator and CD16 miniature DC input DC output carrier demodulator to produce a high level analog DC output suitable for recording and control.
-
Product
Test and Measurement Grade Vacuum Pressure Transducer
P897V
-
The P897V is designed for a wide variety of pressure measurements where high resistance to vibration and superior stability through temperature change is required. The zero and full-scale output calibrations are set by the potentiometer adjustments accessible from the top cover. The P897V is digitally compensated and corrected to provide high accuracy pressure measurement in a robust cylindrical form factor. Small vacuum pressures are accurately measured with full scale vacuum ranges as low as 2.22 InH2O.
-
Product
ReCalibration and Post Calibration Software
SI58
-
The SI58 software allows the user to set zero and span as well as do full temperature compensation and linearity corrections for your Validyne USB pressure transducer. The SI58 provides everything needed to change the range of your transducer and calibrate it through the new full scale pressure. Corrections to non-linearity and temperature error are also possible. The SI58 software provides prompts to the operator for temperature and pressure points to achieve an accurate calibration.
-
Product
Draft Range Trasmitter
DR800
-
The Validyne Model DR800 Draft Range Transmitter is designed exclusively for very low pressure measurement needs. It has a "true" full-scale range as low as 0.25" H2O, making it ideal for air flow control applications. It can be turned down to 0.1" H2O; higher full-scale ranges to 100" H2O are available. The DR800 offers 0.5% accuracy and an operating temperature range of -20F to +185F. The total combined temperature effects are less than 3%/100F.
-
Product
Very Low Pressure Variable Reluctance Sensor
DP103
-
The Validyne DP103 is designed for exceedingly low differential pressure measurement applications where high accuracy is required under rough physical conditions. With full scale ranges down to -0.008 psid (-0.56cm H2O), this instrument is being used in the measurement of very low flow rates of gases where symmetrical pressure cavities are required for dynamic response. It is also used in very small leak detection and pressure null detection systems.
-
Product
Variable Reluctance Pressure Sensor Capable of Range Changes
DP15
-
An easy-to-replace pressure-sensing diaphragm maximizes the system's functionality by making pressure measurements from 2.22" H2O to 3200 psi in one compact unit. Rugged and reliable, the DP15 pressure sensor provides superior accuracy for measuring low-pressure liquids and gasses, while it withstands the abuse of field and laboratory testing. The ability to change full scale ranges make the DP15 a very cost effective solution for applications that need different pressure ranges or university labs.
-
Product
General Purpose Basic Carrier Demodulator
CD15
-
The CD15 Sine Wave Carrier Demodulator operates with variable reluctance transducers to provide a DC output signal for dynamics as well as steady state measurements. A 5kHz sine wave excitation is applied to the two inductance ratio arms of the transducer and the resulting output is demodulated and amplified using the latest integrated circuit techniques. The DC output is obtained from an active filter circuit and gives a uniform response from steady state to 1000 Hz. The low impedance sine wave excitation allows operation with the transducer located over 1,000 feet from the CD15.
-
Product
Test and Measurement Grade Pressure Transducer for CAN Bus
P896
-
The P896 is a test and measurement grade pressure transducer for applications requiring high accuracy and outstanding performance through ambient temperature changes. The P896 is digitally compensated and corrected to provide high accuracy pressure measurement in a robust cylindrical form factor.















