Network Technologies Inc
A company that specializes in both the manufacturing of IT and audio/visual (A/V) solutions and providing technology consulting services.
- 800-742-8324
330-562-7070 - 330-562-1999
- sales@ntigo.com
- 1275 Danner Dr.,
Aurora, OH 44202
United States of America
-
product
Smoke Detection Sensor – 120VAC Wire-In with Battery Backup
ENVIROMUX-SDS-120V
For warning of smoke and invisible fire particles. Ionization smoke detector. Applications from 40°F to 100°F (4°C to 38°C). Front loading battery door. 9V battery backup (included) in case of power failure. One button design for easy testing and HUSH mode activation control. LED indicates four modes of operation: standby condition, alarm condition, alarm memory and hush mode. Hush mode: silences false alarms for 8 minutes, or low battery warning for 13 hours. Voltage supply: 120VAC. Pre-stripped wiring harness with tinned strands. Audio alarm: 85dB at 10ft. Dimensions: 5" diameter x 1.75" depth. Dust cover prevents false alarms. Tamper resist feature. Links with up to 24 devices. Max distance between first and last device: 1000ft (305m). Alarm memory indicates initiating alarm in interconnected systems. Use compatible relay (ENVIROMUX-RLY-SDS120V) for connection to the ENVIROMUX system or other auxiliary warning devices such as external sirens or stairwell lighting. ENVIROMUX-RLY-SDS120V includes normally open and normally closed contacts. Contact ratings: 10A at 120VAC, 5A at 30VDC. Regulatory approvals: UL.
-
product
Glass Break Detection Sensor
ENVIROMUX-GBS
Acoustically detects the cracking of glass. Adjustable sensitivity. Includes mounting hardware. Connect to RJ45 or digital input sensor ports. Supports CAT5/5e/6 UTP or STP cables. Screw terminal. To connect to the RJ45 inputs use CAT5/5e/6 cable terminated at one end with RJ45 connector. Connect the un-terminated end to the sensor screw terminal. Maximum cable length: 1,000 ft (305 m). Powered by ENVIROMUX-2D/5D/16D.
-
product
Digital Input/Output Expander (Normally-Open Relay Contact Outputs)
ENVIROMUX-DI16DOR16
Adds 16 digital inputs and 16 digital normally-open relay contact outputs to the ENVIROMUX-2D/5D/16D. Interfaces with the ENVIROMUX-2D/5D/16D via the RJ45 Sensor Port. Digital inputs: 16 screw terminal pairs for connecting dry contact devices; One screw terminal pair for tachometer; 0 to 255 Hz. Accepts 26 to 16AWG wire. Potential free. Voltage range: 0 to +36VDC. Over-voltage surge protected. Digital outputs: 16 screw terminal pairs for normally-open relay contact outputs. Accepts 26 to 16AWG wire. Potential free. Rated switching load: 0.5A @ 125 VAC, 1.0A @ ±30VDC. Fused. Supports CAT5/5e/6 cable up to 500 ft. (152.4 m). Includes 5V/3A power supply. Compatible with ENVIROMUX-2D/5D/16D. Dimensions WxDxH: 6.49x3.10x1.78 in (165x79x45 mm). Regulatory approvals: RoHS.
-
product
Day/Night IP Surveillance Camera
ENVIROMUX-IPCAM-N
View and control the camera from the ENVIROMUX web interface, the camera web interface, included software, or with a compatible cell phone. With the ENVIROMUX-2D/5D/16D, a triggered snapshot can be forwarded in alert e-mails. A snapshot can be triggered by any programmed event (motion detection, door open/close, glass break, smoke, liquid detection, etc.). Image sensor: 1/4" progressive scan CMOS sensor. Video Streaming: simultaneous Motion JPEG and MPEG-4. Frame rate: 30fps at 640x480 (VGA) resolution. Lens: F2.0, 4.3 mm (0.17 in), 12 infrared LEDs for night vision. RJ45 connector. Wireless models: wireless IEEE 802.11 b/g up to 54 Mbps. Regulatory approvals: CE, FCC, RoHS.
-
product
Rugged Door Contact Sensor with Universal-Style Magnet
ENVIROMUX-DCSR-U
Monitors access with a magnetic bridge sensor (no special inserts necessary). Ideal for commercial and industrial installations in harsh environments. Heavy-cast aluminum housing with 18-inch stainless steel armored cable. Floor-mounting hardware included. Universal-style magnet option has a smaller width and depth that provides greater installation flexibility. For normally open or normally closed circuit connection. Wide actuating gap, approximately 3". Maximum cable length: 1,000 ft (305 m). Dimensions WxDxH (in): Magnet: 3.13x0.81x2.13 (79x21x54 mm), Switch: 3.5x1.5x0.44 (89x38x11 mm). Regulatory approvals: UL.
-
product
Smoke Detection Sensor - UL Approved
ENVIROMUX-SDS
For warning of smoke. Photoelectric smoke detector. Smoke sensitivity: 0.98-2.4%/ft. Built-in 135° F (57° C) thermal heat sensor. Includes mounting hardware. Connect to RJ45 or digital input sensor ports. Supports CAT5/5e/6 UTP or STP cables. Screw terminal. To connect to the RJ45 inputs use CAT5/5e/6 cable terminated at one end with RJ45 connector. Connect the un-terminated end to the sensor screw terminal. Operating temperature: 14 to 122°F (-10 to 50°C). Maximum cable length: 1,000 ft (305 m). Powered by ENVIROMUX-2D/5D/16D. Regulatory approvals: UL, RoHS.
-
product
DC Voltage Detector
ENVIROMUX-S60VDC
Monitors up to two DC voltages: -60VDC ~ 0VDC or 0VDC ~ 60VDC. Connector: Screw Terminal, 5-position. Supports CAT5/5e/6 cable up to 1,000 ft. (305 m). Includes Mounting Hardware. Operating temperature: 32 to 158°F (0 to 70°C). Regulatory approvals: CE, RoHS.
-
product
Duct Mount Temperature/Humidity Sensor
ENVIROMUX-STHS-DCT
Combines excellent stability with easy installation and reliable operation. Duct Mount ENVIROMUX-STHS-DCT: Applications from 14 to 140°F (-10 to 60°C). Temperature accurate to within ±0.54°F (±0.3°C). Relative Humidity accurate to better than ±3% from 10 to 90% relative humidity at 68°F (20°C). Insensitive to dust and most chemicals. Requires the ENVIROMUX-S420MA-24V to operate. Maximum cable length: 500 ft (152m). Regulatory Approvals: CE, RoHS. Enclosure: IP65, NEMA 4.
-
product
Smoke Detection Sensor - CE Approved
ENVIROMUX-SDS-CE
For warning of smoke. Photoelectric smoke detector. Smoke sensitivity: 0.08-0.14 dB/m. Built-in 135° F (57° C) thermal heat sensor. Includes mounting hardware. Connect to RJ45 or digital input sensor ports. Supports CAT5/5e/6 UTP or STP cables. Screw terminal. To connect to the RJ45 inputs use CAT5/5e/6 cable terminated at one end with RJ45 connector. Connect the un-terminated end to the sensor screw terminal. Operating temperature: 14 to 122°F (-10 to 50°C). Maximum cable length: 1,000 ft (305 m). Powered by ENVIROMUX-2D/5D/16D. Regulatory approvals: CE, RoHS.
-
product
RS232 Extender via One CAT5e/6 up to 3,935 Feet
ST-C5RS-LC
The XTENDEX® RS232 Extender extends one RS232 serial device up to 3,935 feet over a single CAT5e/6/7 cable.
-
product
IP Surveillance Camera
ENVIROMUX-IPCAM
View and control the camera from the ENVIROMUX web interface, the camera web interface, included software, or with a compatible cell phone. With the ENVIROMUX-2D/5D/16D, a triggered snapshot can be forwarded in alert e-mails. A snapshot can be triggered by any programmed event (motion detection, door open/close, glass break, smoke, liquid detection, etc.). Image sensor: 1/4" progressive scan CMOS sensor. Video Streaming: simultaneous Motion JPEG and MPEG-4. Frame rate: 30fps at 640x480 (VGA) resolution. Lens: F2.0, 4.0 mm (0.16 in). RJ45 connector. Wireless models: wireless IEEE 802.11 b/g up to 54 Mbps. Regulatory approvals: CE, FCC, RoHS.
-
product
Large Enterprise Environment Monitoring System
ENVIROMUX-16D
The ENVIROMUX-16D supports 16 external configurable sensors, 8 digital inputs, and 4 output relays for control of external devices. The system also includes three internal sensors: temperature, humidity and power. It features 4 USB ports for USB modem, USB flash drive, or USB LCD screen. Linux inside.
-
product
CATx Surge Protector
SP-CAT5-6V
Protects sensors running on CATx unshielded twisted pair (UTP) cable against the effects of electrostatic discharge, faulty wiring and lightning. The use of two protectors on each end of the line will provide increased protection for each end against surges. Protected pins: (1,2) (3,6) (4,7) and (7,8) pass through. Impedance: 85 to 115 Ohms. Surge suppression: 22Vpeak @ 100A 10/1000µs. Maximum continuous voltage: 6Vpeak. Dimensions WxDxH: 1x3.6x0.9 in (25x91x23 mm). Regulatory approvals: GR 1089, NEC 800.100 and 830.100, ITU 703, UL94 V0 Flame Rated.
-
product
Air Flow Sensor
ENVIROMUX-AFM
Reliable mechanical solution for monitoring air flow. Reacts to any condition causing insufficient flow of air such as malfunctioning cooling fan, increased friction, or physical blockage. Ideal for direct monitoring of a cooling fan, HVAC duct, or under a raised floor. Switch contact is closed when air flow is >8.2 ft/s. Connection: 2x single strand AWG26, length 18 in. Maximum cable length: 1000 ft (305m). Regulatory approvals: RoHS.
-
product
Outdoor Infrared Motion Sensor
ENVIROMUX-IMD-O
Outdoor weatherproof - high reliability against water and insects. Double conductive shielding to eliminate false alarms from light sources. Registers movement in the area covered: 40 ft (12 m) x 50 ft (15 m) - 120° wide. LED lights during detection. Selectable detection paterns: Multi-Level (40 zones) or Pet Alley (18 zones). Unwanted detection areas can be eliminated using the included area masking strips. Selectable Sensitivity: High, Mid and Low. Adjustable to the brightness of surrounding environment with the Day/Night Mode switch. Tamper switch opens when cover is removed. Screw terminal. To connect to the RJ45 inputs use CAT5/5e/6 cable terminated at one end with RJ45 connector. Connect the un-terminated end to the sensor screw terminal. Operating temperature: -4 to 122°F (-20 to 50°C). IP54 compliant. Powered by ENVIROMUX-2D/5D/16D.