product
Resistance Substitution Box
RS Series
The RS Series Resistance Substitution Box is the most commonly used decade box on the market today. The RS Series is not only easier to use, but it is also priced lower than most its competition.
-
product
LCR Meter
ET/QuadTech 1910/1920
The 1920 1 MHz LCR Meter is the most popular and designed to perform capacitance and impedance measurements on a variety of electronic components and materials over a frequency range from 20 Hz to 1 MHz. The1920 features programmable bias voltage from 1 mV to 2 V for biasing capacitors and other semiconductor devices during measurements.
-
product
Capacitance Standard
SCA Series
The SCA Standard Capacitor series are highly stable cost-effective capacitance standards with low temperature coefficient, low losses and a wide range of values of 1 pF - 10,000 F. The cost and flexibility make this our most popular capacitance standard.
-
product
Decade Capacitor
GenRad 1423-A
The GenRad 1423 decade capacitor is a versatile tool for calibration laboratories and production-line testing. With it a bridge can be standardized to an accuracy exceeded only by that of the highest quality, individually certified laboratory standards such as the GR 1404 Reference Standard Capacitors.Used with a limit bridge, such as the GR 1689 Digibridge, the 1423 facilities fast and accurate production-line measurements of arbitrary capacitancevalues with minimum setup time.
-
product
Precision LCR Meter
1693
The GenRad 1693 LCR Meter Bridge gives you the best combination of features, in an LCR meter, to meet your most demanding testing requirements. It's a versatile, flexible instrument with a full range of programmable test frequencies, speeds, and voltages. An easy to understand display show both primary and secondary measurement parameters. The Digibridge is an excellent choice for metrology applications requiring accurate and repeatable measurements. The 1693 is also widely used in production testing, incoming inspection, component design and evaluation, process monitoring or dielectric measurement applications.
-
product
Programmable Capacitance Decade Box
PCS Series
A broad range of laboratory grade programmable capacitance decade boxes for applications requiring a programmable impedance unit controlled manually and by a computer via an IEEE-488, RS-232 interface.
-
product
Resistance & Capacitance Box
RCS Series
The RCS-box combines the features and specifications of both the R-box and the C-box in one convenient package. Ideal for setting timers, oscillators, and filters, the resistance and capacitance may be used independently, in series, or in parallel. A shorting link allows them to be coupled or separated.
-
product
Digibridge
1659
The GenRad 1659 Digibridge RLC Tester is an easily programmable, microprocessor-based high performance passive component tester. It automatically identifies the type of component under test and measures in the proper range. The result is simple, precise, unambiguous RLC component testing. The GenRad 1659 RLC Digibridge is an instrument for measuring primary parameters of inductance (L), capacitance (C) and resistance (R) and secondary parameters of dissipation factor (D) and quality factor (Q). GenRad designed this single compact unit with maximum flexibility and operator convenience in mind. The simple front panel design of the Digibridge requires less effort to operate. Digital display and user friendly control allows test parameters and limits to be set easily.
-
product
Capacitance Bridge
1620
The GenRad 1620-A Capacitance Measuring System is a self-contained assembly of the GR 1615-A Capacitance Bridge with appropriate oscillator and null detector for measurements at 11 frequencies between 20 Hz and 20 kHz. For applications requiring other or higher frequencies, to 100 kHz, the 1615-A bridge can be supplied separately and the oscillator and detector selected to meet your needs.
-
product
Primary Standard Capacitors
GenRad 1404 Series
The GenRad 1404 Series standard capacitors are the standard of choice in metrology labs, and still used today by standards bodies around the world. These capacitors have been designed as primary reference standards of capacitance with which working standards can be compared.
-
product
High Accuracy Decade Capacitance Box
HACS-Z Series
The HACS-Z Series high accuracy capacitance box is capable of meeting exacting requirements for fixed or adjustable calibration capacitance, or any applications requiring precise and stable capacitance values. You can pick the best unit for your application, without overpaying for ranges that you do not require. Models are available with a range of 1 pF - 11,111 F in as few as 3 or as many as 11 decades.
-
product
Standard Capacitor
1409 Series
The elements used in 1409 Standard Capacitors are selected for low dissipation factor and are stabilized by heat cycling. They are housed in cast aluminum cases, along with silica gel which provides continuous desiccation. These cases are sealed with high-temperature wax. A well is provided in the wall of the case for insertion of a dial-type thermometer. Three jack-top binding posts are provided on the top of the case, and removable banana plugs on the bottom, for convenient parallel connection without error
-
product
Capacitance Standard
GenRad 1417
The GenRad 1417 Four-Terminal Capacitance Standard consists of a 1 F standard capacitor and two precise inductive voltage dividers used to scale the value of the 1 F capacitor up to 1 F in decade steps. This arrangement provides accuracy and stability unattainable with very high-value true capacitors.
-
product
Megohmmeter
1864-9700
The GenRad 1864 Megohmmeter is the choice for more demanding applications. The test voltage can be set to any value from 10VDC to 109VDC in 1-volt steps and to 1090VDC in 10 volt steps. Thus the GenRad 1864 can be set to any common, or uncommon test voltage for ceramic, mica or paper capacitors, or other devices. The reverse resistance of rectifiers can be readily measured; the low test voltages are especially useful in measuring solid state diodes. An additional range on the 1864 Megohmmeter permits measurements up to 200 T (2 x 1014)
-
product
Precision Voltage and Current Sources
VI-700
The VI-700 Voltage and Current Source is a versatile precision dialable or remotely programmable voltage and current source. Its three ranges provide up to 20 V full scale (200 V with the HV option), and down to 100 mV resolution; and 20 mA full scale down to 0.1mA resolution. Both voltage and current outputs are available simultaneously. The output is set by a range selector and thumbwheel switches in the LOCAL mode, or by a digital input at the rear panel. The REMOTE mode control can be a RS232 or IEEE-488 interface.