Current Sources
See Also: Programmable Current Sources, Battery, Voltage Current Sources
-
Product
Triaxial Cable For Current Higher Than 1 A (1.5 M Or 3 M)
16493L
-
16493L can be used as a general purpose triaxial cable for high current applications up to 4.2 A DC and 200 V. It can also be used for low current applications down to the sub-pA level.
-
Product
3-Phase Programmable AC Source
-
Chroma Systems Solutions, Inc.
Delivers the right solution to simulate all kinds of input condition of UUT to be utilized in R&D and QA, suitable for commercial applications from laboratory testing to mass production
-
Product
Through Hole type AC Current Sensor
CT-30AR
-
MULTI MEASURING INSTRUMENTS Co., Ltd.
For measuring electric power (through hole type)
-
Product
High Power Noise Sources
NS-7001
-
The NS-7001 is high-power noise source specifically designed to operate in the 2.11-2.17 GHz UMTS band. It features flat output power that is regulated over a wide temperature range with high rejection outside the operating band of interest. Logic control is provided to enable/disable the noise source and an internal BIT function continuously monitors the output power. Other frequency bands and power levels are available.
-
Product
High-Voltage, High Current I/O Module
Model JI-4516
-
The JI-4516 module is a versatile, easy-to-use device for adding high-voltage, high-current digital I/O capability to a computer system via a USB connection. The module is comprised of 8, low-side power MOSFET switches, and 8 high-voltage inputs. I/O ground isolation eliminates ground-loops and provides protection from noise and switching transients during high-current load switching. The JI-4516 is available as either a desktop unit or low-cost OEM board.
-
Product
200 Amp AC Current Adaptor
DL6701
-
The DL6701 is a compact 200A AC current clamp adaptor with voltage output via standard 4 mm connectors. To be connected to a digital multimeter or other voltage measurement device.
-
Product
Mobile Communications DC Source, 15V, 3A
66311B
-
The Keysight Mobile Communications DC Source 663xx series offers several features ideal for testing wireless and battery powered devices. Excellent voltage transient response ensures maximum test-system throughput by minimizing device shutdowns due to significant voltage drops in the test wiring. Built-in advanced measurement system to accurately measure battery current drains when the device operates in different modes and a Keysight-developed feature that enables cellular telephone manufacturers to detect permanently and intermittently open-sense wire connections.The Keysight 66311B mobile communications DC source provides fast transient, exceptional sourcing, and precision measurement.
-
Product
Clamp type AC Current Sensor/for Load Current Measurements(CT Series)
CT-3000
-
MULTI MEASURING INSTRUMENTS Co., Ltd.
*Ultra big CT window*AC 1A~3000A*Current measurements of main cable
-
Product
Direct Current Measurement Card
LQI5
-
Computer Gesteuerte Systeme GmbH
The LQI5 is a precision direct current measurement card. It features 6 measurement ranges for unipolar current measurements of up to 32 A. Current pulses shorter than 5 seconds can be measured up to 65 A.
-
Product
High Frequency Current Transformer
HFCT Ø 140mm
-
Techimp Clamp High Frequency Current Transformer model 140 is an inductive sensor for partial discharge measurements. It is suitable for online /off line PD tests on : large diameter cables ; grounding rod bar ; etc. A TNC termination is available to connect the Clamp HFCT 140 to the TechImp PD analyzer : PDCheck , PDBase etc. The arrow indicates the requested input current (Iin) direction to get coherent output voltage (Vout) polarity respect to ground. When the sensor is installed with the arrow directed to ground, the detected voltage signal (Vout) has the same phase of the input current (Iin).
-
Product
150 A, 5 MHz Current Probe - AC/DC, 150 A rms, 500 A Peak Pulse, 6 Meter Cable
CP150-6M
-
Teledyne LeCroy current probes are available in a variety of models for a wide range of applications. The full range of Teledyne LeCroy current probes includes models with bandwidths up to 100 MHz, peak currents up to 700 A and sensitivities to 1 mA/div. Teledyne LeCroy current probes are often used in applications such as the design and test of switching power supplies, motor drives, electric vehicles, and uninterruptible power supplies.
-
Product
Current Meter
MTD32
-
The mezzanine module (mezzanine) MTD32 is designed to measure instantaneous current values over 32 channels.
-
Product
Dual Mobile Comm DC Source w/ Battery Emulation
66319B
-
The Keysight Mobile Communications DC Source 663xx series offers several features ideal for testing wireless and battery powered devices. Excellent voltage transient response ensures maximum test-system throughput by minimizing device shutdowns due to significant voltage drops in the test wiring. Built-in advanced measurement system to accurately measure battery current drains when the device operates in different modes and a Keysight-developed feature that enables cellular telephone manufacturers to detect permanently and intermittently open-sense wire connections. The Keysight 66319B dual output mobile communications dc source provides two outputs for testing both the main battery power and the battery charger circuitry, allowing customers to test phones and chargers with the same equipment. This feature helps save on rack space (2 outputs in a rack box) and eliminates the need for two separate power supplies.
-
Product
Current Booster
BUX
-
The current boosters allow performing tests up to 2000A, 3000A and 5000A. The option is made of a module, which incorporates a power transformer, which generates a low-voltage, high current output and a metering CT, which measures the output current and sends the metering to eKAM.
-
Product
5 Amp High Accuracy Current Probe
HA5
-
Our HA5 Current Probe covers the measurement range from 20 milliamps to 5 amps, making it the best choice for measuring very small loads and the outputs of CT (Current Transformer) step-down circuits.
-
Product
Laser Diode Source Product Family
LDS-7200
-
5 nanometers tuning range• 10 picometer setpoint accuracy• 0.1 picometer resolution• 20mW output power• 0.005 dB power stability• Built-in coherence control• Integrated function generator• USB remote interface• Application program with source code
-
Product
PXI/PXIe Wide Current Range Multiplexer Module, Dual 12-Channel, 1-Pole
40-514-107
-
The 40-514-107 (PXI) and 42-514-107 (PXIe) are low density multiplexers in dual 12-channel, 1-pole configuration. They are capable of switching a wide range of current, from 10 μA to 2.5 A at 220 VDC/250 VAC. The current capability of the module permits the use of a single module type for both low and medium current test applications.
-
Product
AC Power Source
SPS-100
-
Kongter Test & Measurement Co., Limited
SPS-100 is designed for various tests of analog and digital AC Voltage meter and Current meter, Single/three phase active and reactive power meter, Phase angle meter, Single/three phase power factor meter, frequency meter, and synchronous-meter, Single/three phase active and reactive power meter; it also outputs 2nd ~63rd harmonics.
-
Product
High End Current Sensors
-
AC and DC currents with an accuracy down to 1ppm. Our standard products offers the following features: Automotive current sensors. Extended temperature current sensor - 85 deg Celcius. AC current sensor - DC current sensor.
-
Product
Standard Round 2m Cables, Shielded, for Higher Current
ST010-S
-
Connection to digital boards, intended for higher currents. to be used with CPCI-1500, APCI-1500, APCI-1564, APCI-2032.
-
Product
Digital Current Integrator
-
The ORTEC Model 439 Digital Current Integrator was designed to accurately measure DC currents or the average value of pulse currents such as produced by accelerator beams. It digitizes the input current by producing an output pulse for specific values of input charge. A front-panel switch permit the selection of three different amounts of charge (10–10, 10–8 or 10–6 coulomb) required to produce an output pulse. The instrument has a digitizing rate from 0 to 10 kHz to provide wide dynamic range on each setting and high-resolution readout without meter interpolation.
-
Product
Current Probe For Multimeters
CP 1000
-
The CP 1000 current probe has been designed for use with multimeteres respectively for accurate, non-intrusive measurement of AC, DC and complex waveform currents.
-
Product
Noise Figure Analyzers & Noise Sources
-
Keysight Technologies provide a range of noise figure measurements solutions to meet your needs, from the NFA series noise figure analyzers to the noise figure measurement personalities for our spectrum analyzers. We also have a range of noise sources to complete the measurement solution.
-
Product
Cryogenic Current Comparator (CCC)
6200A
-
Measurements International Ltd.
Introducing the Model 6200A Cryogenic Current Comparator Bridge (CCC) from Measurements International (MI) – the ultimate solution for achieving the highest level of resistance calibration accuracy. With an uncertainty of less than 3 parts in 10-9, our CCC surpasses all other technology on the market.
-
Product
NI-9208, 500 S/s, ±20 mA, 16-Channel C Series Current Input Module
780968-01
-
500 S/s, ±20 mA, 16-Channel C Series Current Input Module - The NI‑9208 is designed with industrial systems in mind. It includes a high-resolution mode with 50/60 Hz rejection to remove low frequency noise. It has high-channel density to reduce the number of modules needed, which leaves slots open for other measurement types or for reducing the overall per channel cost of the system. The NI‑9208 uses a standard D‑SUB connection for use with cables and connector blocks.
-
Product
Eddy Current Testing
-
Shanghai Xianda Denshijiki Industry Co.,Ltd
And the eddy current generated on the specimen by the specimen by the action of the magnetic field can not be detected (defect) and the change due to the influence of the material is detected.
-
Product
Current Sense Magnetics
-
Current sense magnetics are used as a low loss method for sensing AC current in a circuit and also provide electrical and safety isolation between the source of the current and the measurement circuit. The key parameters for a current sense transformer are the rms current rating (to ensure it does not overheat in the application) and the safety and voltage isolation (to ensure it conforms to the end-application requirements).
-
Product
Current Sensing
-
voltage-output, current-sensing amplifier family that integrates an internal shunt resistor to enable high-accuracy current measurements at common-mode voltages that can vary from 0 V to 36 V, independent of the supply voltage. The device is a bidirectional, low- or high-side current-shunt monitor that allows an external reference to be used to measure current flowing in both directions through the internal current-sensing resistor sensor. The integration of the precision current-sensing resistor provides calibration equivalent measurement accuracy with ultra-low temperature drift performance and ensures an optimized Kelvin layout for the sensing resistor is always obtained.
-
Product
Low Power Programmable AC Source
61600 Series
-
Chroma Systems Solutions, Inc.
Power:500VA (61601)1000VA (61602)1500VA (61603)2000VA (61604)4000VA (61605)Voltage range: 0-150V/0-300V/AutoFrequency: 15Hz 1000HzCompact size and weight attributable to advance PWM technologyBuilt-in PFC, provide input power factor over 0.98 (full load)AC+DC output mode for voltage DC offset simulationProgrammable slew rate setting for changing voltage and frequencyProgrammable voltage, current limitOne-key recall for 9 different voltage and frequencyLow output impedance for testing IEC 61000-3-2 ( 61605 )Comprehensive measurement capability, V, Irms, Ipk, Inrush, P, Q, S, PF, CF of current and etc.High output current crest factor, ideal for inrush current testingTurn on, turn off phase angle controlTTL signal which indicates ON/OFFAnalog programming interface3 units combined to 3-phase power outputEasy-use software for operation and ON/OFF testOptional GPIB and RS-232C interfaceFull protection: OP,OC,OV and OT protection