Current Sources
See Also: Programmable Current Sources, Battery, Voltage Current Sources
-
Product
Micropower Voltage Reference
ISL21010
-
The ISL21010 is a precision, low dropout micropower bandgap voltage reference in a space-saving SOT-23 package. It operates from a single 2.2V to 5.5V supply (minimum voltage is dependent on voltage option) and provides a ±0.2% accurate reference. The ISL21010 provides up to 25mA output current sourcing with low 150mV dropout voltage.
-
Product
PXI Battery Simulator Modules
-
These PXI battery simulators are designed to simulate the power supplies of portable battery powered equipment and the single cell (model 41-753) is particularly suitable for cell phone testing. These modules can source current to simulate a battery supply or sink current to simulate a battery under charge.
-
Product
High Current Calibrator
MC151
-
MC151 Current calibrator is an accurate current source capable of 120 A. Typical uses include calibration of current sensors, current probes, current transformers, shunts, ammeters, DMMs or as stable current source for test and development applications. The calibrator is equipped with a built-in multimeter that can be used for simulation of programmable transconductance or current amplifier.
-
Product
DC Constant Current Source
-
SCR ELEKTRONIKS have developed equipment namely“DC CONSTANT CURRENT SOURCE”. The system comprises of Constant Current Sources having ranges: 900A continues & 3000A short time at 8V maximum.
-
Product
DPS & PMU
-
Analog Devices parametric measurement units (PMU) and device power supply (DPS) products provide a flexible range of voltage and current source/measurement capability to meet a wide range of cost-sensitive test application needs. The DPS will source currents to 1.2A and multiple devices can be ganged for even higher power applications.
-
Product
Calibrator, Calibrated w/Data, Current, 185 mm, 78 mm, 38 mm
72-6694 CAL D
-
The 72-6694 CAL D from Tenma is a current calibrator. It provides quality and accuracy of handheld calibrator of precision current source. It features large LCD display (maximum display counts 1999, 13mm (0.5") digit size). The current calibrator has 006P DC 9V, MN1604/PP3 battery or equivalent alkaline type or heavy duty type power supply. The dimension is 185mm × 78mm × 38mm (7.3" × 3" × 1.5") and weight is 265g/0.58lb (including battery). It has adjustable 0 to 24mA current source, 2 ranges (0 to 19.99mA (0.01mA display resolution, ±(0.25% FS + 1d) accuracy), 0 to 24mA (0.1mA display resolution, ±(0.5% FS + 1d) accuracy).
-
Product
Earth Contact Resistance Tester
-
SCR ELEKTRONIKS have developed an equipment namely Earth Contact Resistance Tester to test the appliance. To ensure the safety of operator it is essential that the Earth path (connection) should offer minimum impedance to by pass short circuit Current to Earth. This is ensured by measuring Resistance of the Earth path by passing heavy Current say 25 A. The Earth Contact Resistance Tester essentially comprises of a Variable Current source with digital Ammeter to measure the Current supplied. The Voltage drop across the Earth path is measured with a digital Voltmeter. Optionally for a particular Current (25 A) the meter can be calibrated in terms of Resistance. A timer is provided to switch off the Current after the Set Time.
-
Product
Calibrator, 0 to 24 mA, Current, 185 mm, 78 mm, 38 mm, ± 0.5%, 265 g
72-6694
-
*Adjustable 0 to 24 mA current source*Current calibrator drives loads up to 500 Ω*Large LCD display*Sampling Time : Approximately 0.4 seconds*Over Input Indicator : 1*Operating Temperature : 0°C to 50°C ( 32°F to 122°F)*Size : 185 × 78 × 38 mm (7.3 × 3 × 1.5 inches)*Weight : 265 g (0.58 lb) including battery*Requires one 9 V battery - not included*12 month limited warranty *view Terms & Conditions for details
-
Product
PXI Digital to Analog Converters
-
Keysight's PXI digital to analog converters and V/I sources are capable of supplying high and low voltages levels as well as source currents on one or multiple channels.
-
Product
4 Thermocouples/RTD Ch
APCI-3200-4
-
18-bit resolution, 16-bit accuracyEach channel can be configured either for thermocouples/RTD or as an analog voltage input channel4 analog input channels for thermocouple typesJ, K, T, E, R, S, B, N - or 2 diff. analog input channels for the acquisition of resistance temperature detectors (Pt100)- or 16 SE/8 differential analog voltage input channels, ± 2.5 V8 independent current sources for resistance temperature detectors (RTD) and one current source for cold junction compensationCold junction compensation (on separate screw terminal board PX 3200)Gain and offset calibrationLinearisation through table and calculation for the thermocouple types J, K, T, E, R, S, B, N and RTDsProgrammable gain16-bit accuracy with sample rates of 20, 40, 80 or 160 Hz (other rates on request)4 digital input channels, 24 V and 3 digital output channels, open collector, isolated
-
Product
16-Channel VME Current Source & Analog Measurement Module
V460
-
The V460 is a VME-based versatile source/measurement unit. It includes a programmable constant-current source, a precision programmable gain 16-bit analog-to-digital converter, and a 4-wire, 16-channel analog multiplexer. An internal microprocessor supervises channel scanning according to user loaded parameters, reporting sensor voltage drops or, for selected sensor types, engineering-unit data.
-
Product
PXI-4130, ±20 V, ±2 A DC, 40 W PXI Source Measure Unit
779647-31
Programmable Power Supply
±20 V, ±2 A DC, 40 W PXI Source Measure Unit - The PXI‑4130 is a programmable source measure unit (SMU). It has a single isolated SMU channel that offers a four-quadrant output that incorporates remote (4‑wire) sense. With its five current ranges, it is ideal for transistor characterization that requires accurately sourcing a constant current or voltage while sweeping another current. The PXI‑4130 also includes a utility channel that can source either current or voltage. This PXI SMU can act as either a constant voltage source or a constant current source, with a settable compliance limit for either mode. In addition, you can enable remote sense on the SMU channel to maximize voltage output and measurement accuracy on your device under test (DUT) for high-precision applications.
-
Product
High Powered External IP Transmitter
PowerSting
-
The PowerSting is a series of external high power transmitters (5kW, 10kW, and 15kW) for the SuperSting R8/IP/SP and SuperSting R1/IP/SP. The PowerSting system is a fully programmable constant voltage//constant current source. The PowerSting system comes with an SGS generator and a wireless repeater box, and operates in both wired and wireless modes. The applications of the PowerSting-SuperSting system include vertical electrical sounding, 2D electrical imaging, 3D electrical imaging, 3D offset electrical imaging of a 2D survey line in both manual and automatic modes.
-
Product
RCD/LOOP/PAT Testers
-
Kyoritsu Electrical Instruments Works, Ltd.
Custom microprocessor controlled for highest accuracy and reliability. 3 LEDs for checking correct wiring status. 0 and 180 degree phase angle switch permits quick tests and consistent readings. Digital read-out of tripping time. Constant current source circuitry ensures that a fluctuating mains voltage does not affect the accuracy of readings. Large custom digital display readout. Visual indication of reversed phase and neutral wiring at socket. Designed to IP54 Rating. Complies with IEC 61557 Test of a large kind of RCD''''s: Standard, Selective, AC and A (DC sensitive breakers)
-
Product
Hall Effect Measurement system
HMS-5000
-
Constant current source + Van der Pauw method terminal conversion system
-
Product
PC Based High Current Test Set for Circuit Breakers and Temperature Rise Test Equipment
-
This equipment comprises of high current source for testing of circuit breakers with additional facility for temperature rise testing (thus incorporating testing for moulded case, vacuum & air circuit breakers as per IEC 60947-2). The system integrates a servo controlled source with closed loop current feedback to maintain the current constant. It has the necessary instrumentation for maintaining current at full load & other conditions arising in testing at high current. The bench has a PC based control system with temperature data logger (24 channel with ch-ch isolation amplifiers). The data logger displays as well as stores a set of temperature values with time.
-
Product
Capacitor for DC Filtering
FIL2
-
Lifasa - International Capacitors, SA
FIL condensers are specially designed for use in direct current sources and their functions are to filter the alternating output ripple as well as protect the line from momentary spikes and sudden power surges.
-
Product
16 Thermocouples/RTD Ch
APCI-3200-16
-
18-bit resolution, 16-bit accuracyEach channel can be configured either for thermocouples/RTD or as an analog voltage input channel16 analog input channels for thermocouple typesJ, K, T, E, R, S, B, N - or 8 diff. analog input channels for the acquisition of resistance temperature detectors (Pt100)- or 16 SE/8 differential analog voltage input channels, ± 2.5 V8 independent current sources for resistance temperature detectors (RTD) and one current source for cold junction compensationCold junction compensation (on separate screw terminal board PX 3200)Gain and offset calibrationLinearisation through table and calculation for the thermocouple types J, K, T, E, R, S, B, N and RTDsProgrammable gain16-bit accuracy with sample rates of 20, 40, 80 or 160 Hz (other rates on request)4 digital input channels, 24 V and 3 digital output channels, open collector, isolated
-
Product
Programmable DC Current Source
Model 121
-
The Model 121 programmable DC current source is a precision instrument suitable for bench-top use or panel-mounted operation in labs, test facilities, and manufacturing environments. It provides a low-noise, highly stable source of current up to 100 mA, with convenient manual selection through 13 pre-set output levels, each representing a ten-fold change in power when attached to a resistive load. A “user” setting allows the current output to be defined anywhere within the operating range of the unit, from 100 nA to 100 mA.
-
Product
16CH Battery Cell Simulator
Chroma 87001
-
Chroma Systems Solutions, Inc.
Chroma 87001 Battery Cell Simulator is a high precision, programmable, and bidirectional DC power source with both voltage source and current source functions. In addition, the model can be used as a multi-channel DC power supply or an electronic load as well. A single simulator has 16 channels and each of them can set voltage and current respectively via Chroma software.
-
Product
SpikeSafe DC Current Sources
-
The Vektrex SpikeSafe DC Current Sources provide reliable drive for LED/laser diode reliability, IESNA LM-80 test, and other current-driven test applications. Models support currents from 500mA to 60A and compliance voltages from 50V to 400V. All models feature individual channel control, precise current, and high power density — typically 6.4kW-8kW.
-
Product
Power Sources
GF303
-
Beijing GFUVE Electronics Co.,Ltd.
GF303 Program-controlled three phase AC standard power source is a high precision three phase AC standard current source and AC standard voltage source.
-
Product
PCI Digital I/O Boards
PISO-P32A32U
-
The PISO-P32A32/P32A32-5V/P32A32U has 32 channels of optically isolated digital input and 32 channels of optically isolated digital output, arranged into four isolated banks. Each digital output offers a PNP transistor and integral suppression diode for the inductive load. Isolated input channels 0-15 are designed into group A, while channels 16-31 are group B. Isolated output channels are designed into group C and Group D. The photo-coupler input of the PISO-P32A32-5V can be powered by either an internal current source or an external power supply, while the input of the PISO-P32A32/P32A32U works with external power only.
-
Product
CT/VT Test System
-
Fully pre-wired comprehensive turn test system. *Suitable for CTs up to 6000A & VTs up to 132kV. * Precision to (0.005 class) internal multi-ratio standard CT. * Internal 4KA current source. * State-of-the-art Instrument Transformer Test Set AITTS-98 with computer & printer interfaces. * Electronic potential divider facilitates testing any VT ratio upto 132kV. * Current & potential burdens.
-
Product
Temperature Rise Test Panel
2000A
-
SCR ELEKTRONIKS have developed “TEMPERATURE RISE TEST BENCH FOR MEDIUM VOLTAGE SWITCH BOARDS” to measure rise in temperature at various points as mentioned in standard at junctions. The set-up consists of a True RMS Constant Current Source (to maintain the Current within + / - 1 % of set value with Digital Indication), PC based control system, Temperature data logging on PC, Servo-Controller and other indications. Digital voltmeter Primary Voltage) indicates the position of auto transformer (variac).
-
Product
Solar Array Simulator DC Module, 65V, 8.5A, 510W
E4361A
Simulator
The Keysight E4361A is a 510W solar array simulator DC power module that simulates the output characteristics of a solar array. The E4361A is primarily a current source with very low output capacitance. It offers fast I-V curve changes allowing you to accurately simulate the output of different solar arrays under various environmental conditions (ex. temperature, age, eclipse, spin etc.). The E4360 gives you the flexibility to operate it in two ways:
-
Product
16-Ch Digital Input Modules
ADAM-5051
-
Input voltage: 30 VmaxCircuit type: Pull-Up current: 0.5 mA (Source Type)Power consumption: 0.53 WChannels: 16
-
Product
Capacitor for DC Filtering
FIL1
-
Lifasa - International Capacitors, SA
FIL condensers are specially designed for use in direct current sources and their functions are to filter the alternating output ripple and protect the line from instantaneous peaks and surges of tension.
-
Product
1μΩ-4kΩ AC Milliohmmeter Low Resistance Tester
TH2521
-
Shenzhen Chuangxin Instruments Co., Ltd.
TH2521 AC Milliohmmeter is a high-performance and intelligent tester widely used to test contact resistance, internal resistance and battery voltage. The application of constant current source with 1kHz frequency can greatly eliminate the potential error caused by thermoelectricity on DUT. This meter has the function to automatically detect contact failures on test cable. At the range of 30mΩ, basic R resolution can reach 1μΩ. It is applicable for transformer, inductance coil copper resistance, relay contact resistance, switch, connector contact resistance, wire resistance, PCB line and via reistance dan metal defect detection, etc. In the mean time, signals, such as HIGH, LOW, PASS, can be output through HANDLER interface, thus it is very convenient to be used in automatic production line.
-
Product
External DC Bias Adapter
16200B
Bias Tee
The 16200B test fixture is designed to operate with high frequency LCR meters and impedance analyzers. It allows you to supply a bias current across the device of up to 5 Adc through a 7 mm port by using an external DC current source.