MUX
Combine multiple signals into one signal.
-
product
Multiplexers (MUX)
WDM
It is highly desirable to reduce the number of cables required to communicate between spaces on Navy ships due to increased weight, cost and maintenance concerns. To reduce weight and expense, copper-based NTDS parallel and serial type cables can be converted to fiber optic and multiplexed using Wavelength Division Multiplexing (WDM) technology. WDM technology allows for multiple fiber optic wavelengths to be combined in a single fiber and then separated back to individual fibers at the distant end. Using Coarse WDM (CWDM) which utilizes wavelengths 20nm apart ranging from 1271 nm to 1611 nm, provides for up to 18 optical wavelengths to be combined into a single fiber. Optionally Dense WDM (DWDM) can be used allowing for up to 160 optical wavelengths.
-
product
PXI Dual 2 Channel Optic Mux FC/PC
40-855-022
Pickering PXI Fiber Optic MEMS Switching cards are available in many high density formats with a choice of 5 different connector styles to suit most applications: FC/APC (for optimal performance), FC/PC and SC/PC for general applications and LC and MU for high density applications. Fiber optic multiplexers create a signal path by redirecting the optical signal into a selected output fiber. This is achieved using Micro-Mechanical Mirrors driven by a highly precise mechanism and activated via an electrical control signal.
-
product
LXI Dual 8:1 Optic MUX LC Loop-Thru
60-850-422
The 60-850 and 60-851 are LXI conformant fiber optic multiplexers that use MEMS switching technology to ensure fast and reliable switching of single-mode (60-850) or multi-mode (60-851) optical signals being carried on fiber connections. The 60-850/851 is available with a variety of connector options and in a variety of multiplexer arrangements. Loop-thru versions are also available for easy multiplexer expansion.
-
product
PXI 2 Amp MUX, Single 8-Channel 8-Pole
40-635-004
The 40-635 2 Amp Multiplexer module is available in 9 standard configurations as well as 9 half density configurations, all using high quality electro-mechanical signal relays allowing each channel to switch current up to 2A and voltage up to 300VDC/250VAC.The module is suitable for signal routing in ATE and data acquisition systems. Connections are made via a front panel 78-way D-type connector.
-
product
High Density 1xN mux or 2xN Matrix Switching Systems
JX Series
This compact and economically priced series can be used as either 1xN multiplexers, 2xN matrices, or individual switches. As multiplexers, they can be used as a large number of individual muxes or jumpered together to form as large a mux as you need to switch a large number of inputs or outputs to one common port. As a 2xN matrix they allow you to switch any number of signals between two ports of a DVM, DMM, LCR, or other type of meter or supply. Individual relay modules are available for other configurations requiring discrete SPST or SPDT relays with standard or power relays.
-
product
PXI High Density MUX BRIC, 80-Chan, 10-Pole
40-570-415
This range of High-Density Multiplexer is part of our BRIC family. These MUX's are designed to simplify the connection of a common set of test equipment to one of a number of different devices for testing (simultaneous multiple channel selection is also possible, without limitation). These multiplexers are ideal for applications where the equipment needs to conduct the same test process on a series of similar devices one at a time. They are available in a variety of configurations that allow testing with differing number of devices to be tested and different connection widths to suit differing test equipment pin counts. All version are supported in a BRIC8 construction that occupies eight PXI 3U mechanical slots, one of which provides the PXI interface and power.
-
product
PXI 3A Power MUX BRIC, 8-Channel, 12-Pole
40-571-302
The 40-571 is a Power Multiplexer designed to simplify the connection of a common set of test equipment to one of a number of different devices for testing (simultaneous multiple channel selection is possible for most configurations, see switching specifications for restrictions). It is ideal for applications where the equipment needs to conduct the same test process on a series of similar devices one at a time. It is available in a variety of configurations that allow testing with differing number of devices to be tested and different connection widths to suit differing test equipment pin counts.
-
product
Dual 2 X 2 Channel Optic Mux 850nm Multi
40-810-124-M
Pickering PXI Fiber Optic Multiplexers connect a single channel to one of two or four channels. They are available in single or dual multiplexer configurations supporting single-mode or mult- mode fiber.A wide choice of connectors types is available. The 40-810 multiplexer connects the optical channel by redirecting the optical signal into a selected output fiber.
-
product
PXI MUX 1 Bank, 64 Channel Screened 1 Pole
40-610-021-S-1/64/1
This series of high density multiplexer modules feature a wide range of switching configurations, especially useful where a large number of small multiplexers are required. Typical applications include signal routing in ATE and data acquisition systems. Connections are made via a front panel 200-pin connector. Inter-bank linking relays allow multiplexer size to be increased in multiples of in multiples of three by joining the common terminals of adjacent banks. Closing one linking switch produces a 6-channel multiplexer, closing all linking switches produces an 54-channel multiplexer
-
product
SparkFun Qwiic Mux Breakout - 8 Channel (TCA9548A)
Do you have too many sensors with the same I2C address? Put them on the SparkFun Qwiic Mux Breakout to get them all talking on the same bus! The Qwiic Mux Breakout enables communication with multiple I2C devices that have the same address that makes it simple to interface with. The Qwiic Mux also has eight configurable addresses of its own, allowing for up to 64 I2C buses on a connection. To make it even easier to use this multiplexer, all communication is enacted exclusively via I2C, utilizing our handy Qwiic system.
-
product
PXI/PXIe MEMS Optical MUX, 4-Channel, Multi-Mode
40-850A-014-M50-HI
The 40/42-850A-014-M50-HI is a PXI/PXIe 4-channel multiplexer with FC/APC connectors, includes hardware interlock and is part of Pickering's range of PXI Fiber Optic MEMS Switching modules. They are available in many high density formats with a choice of different connector styles to suit most applications: FC/APC (for optimal performance), FC/PC and SC/PC for general applications and LC and MU for high density applications.
-
product
PXI High Density MUX BRIC, 2-Chan, 160-Pole
40-570-012
This range of High-Density Multiplexer is part of our BRIC family. These MUX's are designed to simplify the connection of a common set of test equipment to one of a number of different devices for testing (simultaneous multiple channel selection is also possible, without limitation). These multiplexers are ideal for applications where the equipment needs to conduct the same test process on a series of similar devices one at a time. They are available in a variety of configurations that allow testing with differing number of devices to be tested and different connection widths to suit differing test equipment pin counts. All version are supported in a BRIC8 construction that occupies eight PXI 3U mechanical slots, one of which provides the PXI interface and power.
-
product
PXI/PXIe MEMS Optical MUX, Single 2-Channel, Single-Mode
40-855A-012
The 40/42-855A-012 is a PXI/PXIe 2-channel multiplexer with FC/APC connectors and is part of Pickering's range of PXI Fiber Optic MEMS Switching modules. They are available in many high density formats with a choice of different connector styles to suit most applications: FC/APC (for optimal performance), FC/PC and SC/PC for general applications and LC and MU for high density applications. They are also available with an optional hardware interlock which, when activated, will return all optical switches to their default unpowered state.
-
product
SIMRC - 16-Channel 1-Pole MUX, Screened Reed
1020-R-16-1RF-5/1D
Our small format embedded switching (SIM relay) cards offer a choice of switching configurations using low cost industry standard SIM connectors. They free the designer from the detail of routing complex switching circuits, you may select from a wide range of cards using the built in RS-232 and I2C interfaces. These low-cost embedded switching cards are intended to be mounted on to a simple motherboard. They may be used to construct very high density switching networks. SIM based switching cards also allow for very simple in-field maintenance.
-
product
PXI MUX 4 Banks of 32 Channel 1 Pole
40-610-022-4/32/1
This series of high density multiplexer modules feature a wide range of switching configurations, especially useful where a large number of small multiplexers are required. Typical applications include signal routing in ATE and data acquisition systems. Connections are made via a front panel 200-pin connector. Inter-bank linking relays allow multiplexer size to be increased in multiples of in multiples of three by joining the common terminals of adjacent banks. Closing one linking switch produces a 6-channel multiplexer, closing all linking switches produces an 54-channel multiplexer
-
product
PXI Dual 4 to 1 RF MUX MCX 75 Ohm
40-832-102
The 40-832-102 is a 75 Ohm 4 to 1 RF MUX with 2 banks in a single PXI slot. It has been designed to exhibit low insertion loss and VSWR through the use of modern RF relay technology at an affordable cost. Each MUX has been carefully designed to ensure excellent and repeatable RF characteristics to frequencies of 3GHz with each path having a nominally equal insertion loss. The design of the 40-832 minimizes the injection of noise and unwanted signals into the signal path by careful attention to the mechanical and electrical design.
-
product
PXI High Density MUX BRIC, 8-Chan, 40-Pole
40-570-212
This range of High-Density Multiplexer is part of our BRIC family. These MUX's are designed to simplify the connection of a common set of test equipment to one of a number of different devices for testing (simultaneous multiple channel selection is also possible, without limitation). These multiplexers are ideal for applications where the equipment needs to conduct the same test process on a series of similar devices one at a time. They are available in a variety of configurations that allow testing with differing number of devices to be tested and different connection widths to suit differing test equipment pin counts. All version are supported in a BRIC8 construction that occupies eight PXI 3U mechanical slots, one of which provides the PXI interface and power.
-
product
PXI Single 4 Channel Mux Fibre Optic MU
40-850-314
The 40-850-314 4-channel multiplexer is part of Pickering's range of PXI Fiber Optic MEMS Switching modules. They are available in many high density formats with a choice of different connector styles to suit most applications: FC/APC (for optimal performance), FC/PC and SC/PC for general applications and LC and MU for high density applications. Fiber optic multiplexers create a signal path by redirecting the optical signal into a selected output fiber. This is achieved using Micro-Mechanical Mirrors driven by a highly precise mechanism and activated via an electrical control signal.
-
product
PXI MUX 4 Bank 0f 16 Channel 1 Pole
40-610-021-4/16/1
This series of high density multiplexer modules feature a wide range of switching configurations, especially useful where a large number of small multiplexers are required. Typical applications include signal routing in ATE and data acquisition systems. Connections are made via a front panel 200-pin connector. Inter-bank linking relays allow multiplexer size to be increased in multiples of in multiples of three by joining the common terminals of adjacent banks. Closing one linking switch produces a 6-channel multiplexer, closing all linking switches produces an 54-channel multiplexer
-
product
PXI 3A Power MUX BRIC, 4-Channel, 12-Pole
40-571-301
The 40-571 is a Power Multiplexer designed to simplify the connection of a common set of test equipment to one of a number of different devices for testing (simultaneous multiple channel selection is possible for most configurations, see switching specifications for restrictions). It is ideal for applications where the equipment needs to conduct the same test process on a series of similar devices one at a time. It is available in a variety of configurations that allow testing with differing number of devices to be tested and different connection widths to suit differing test equipment pin counts.
-
product
PXI High Density MUX BRIC, 6-Chan, 160-Pole
40-570-016
This range of High-Density Multiplexer is part of our BRIC family. These MUX's are designed to simplify the connection of a common set of test equipment to one of a number of different devices for testing (simultaneous multiple channel selection is also possible, without limitation). These multiplexers are ideal for applications where the equipment needs to conduct the same test process on a series of similar devices one at a time. They are available in a variety of configurations that allow testing with differing number of devices to be tested and different connection widths to suit differing test equipment pin counts. All version are supported in a BRIC8 construction that occupies eight PXI 3U mechanical slots, one of which provides the PXI interface and power.
-
product
PXI High Density MUX BRIC, 48-Chan, 20-Pole
40-570-316
This range of High-Density Multiplexer is part of our BRIC family. These MUX's are designed to simplify the connection of a common set of test equipment to one of a number of different devices for testing (simultaneous multiple channel selection is also possible, without limitation). These multiplexers are ideal for applications where the equipment needs to conduct the same test process on a series of similar devices one at a time. They are available in a variety of configurations that allow testing with differing number of devices to be tested and different connection widths to suit differing test equipment pin counts. All version are supported in a BRIC8 construction that occupies eight PXI 3U mechanical slots, one of which provides the PXI interface and power.
-
product
PCI High Density Screened MUX 10 Ch 8 Pole
50-670-021-S-10/8
The 50-670 series of very high density multiplexer cards feature a wide range of switching configurations. Typical applications include signal routing in ATE and data acquisition systems.
-
product
PXI/PXIe MEMS Optical MUX, 8-Channel, Single-Mode
40-852A-218
The 40/42-852A-218 is a PXI/PXIe 8-channel multiplexer with SC/PC connectors and is part of Pickering's range of PXI Fiber Optic MEMS Switching modules. They are available in many high density formats with a choice of different connector styles to suit most applications: FC/APC (for optimal performance), FC/PC and SC/PC for general applications and LC and MU for high density applications.
-
product
PXI 2 Banks of 40 Channel 1 Pole MUX
40-615-021-2/40/1
High density multiplexer modules featuring a wide range of switching configurations, especially useful where a large number of small multiplexers are required. Typical applications include signal routing in ATE and data acquisition systems. Each module is factory configured into one of the configuration modes. Connections are made via a front panel 200-pin connector.
-
product
PXI MUX 2 Bank, 32 Channel Screened 1 Pole
40-610-021-S-2/32/1
This series of high density multiplexer modules feature a wide range of switching configurations, especially useful where a large number of small multiplexers are required. Typical applications include signal routing in ATE and data acquisition systems. Connections are made via a front panel 200-pin connector. Inter-bank linking relays allow multiplexer size to be increased in multiples of in multiples of three by joining the common terminals of adjacent banks. Closing one linking switch produces a 6-channel multiplexer, closing all linking switches produces an 54-channel multiplexer
-
product
PXI 16 to 1 Mux 1GHz 50Ohm SMB
40-747-511
The 40-747 is a single 16 to 1 RF MUX available in 50 Ohmhm or 75 Ohmhm versions occupying a single PXI slot. The module is available with SMB or SMA connectors for 50 Ohmhm versions or, 1.0/2.3 or Mini SMB connectors for 75 Ohm versions. Applications for the 40-747 include routing high frequency signals to and from oscilloscopes, analyzers, signal generators and synthesizers, telecoms tributary switching, video/audio switching and switching high frequency logic signals
-
product
PXI/PXIe MEMS Optical MUX, 8-Channel, Single-Mode, 9/125 Fiber
40-852A-118-HI
The 40/42-852A-118-HI is a PXI/PXIe 8-channel multiplexer with FC/PC connectors, includes hardware interlock and is part of Pickering's range of PXI Fiber Optic MEMS Switching modules. They are available in many high density formats with a choice of different connector styles to suit most applications: FC/APC (for optimal performance), FC/PC and SC/PC for general applications and LC and MU for high density applications.
-
product
PXI MUX 8 Banks of 8 Channel 2 Pole
40-610-022-8/8/2
This series of high density multiplexer modules feature a wide range of switching configurations, especially useful where a large number of small multiplexers are required. Typical applications include signal routing in ATE and data acquisition systems. Connections are made via a front panel 200-pin connector. Inter-bank linking relays allow multiplexer size to be increased in multiples of in multiples of three by joining the common terminals of adjacent banks. Closing one linking switch produces a 6-channel multiplexer, closing all linking switches produces an 54-channel multiplexer
-
product
PXI/PXIe MEMS Optical MUX, 4-Channel, Multi-Mode, 62.5/125 Fiber
40-850A-514-M62.5-HI
The 40/42-850A-514-M62.5-HI is a PXI/PXIe 4-channel multiplexer with ST connectors, includes hardware interlock and is part of Pickering's range of PXI Fiber Optic MEMS Switching modules. They are available in many high density formats with a choice of different connector styles to suit most applications: FC/APC (for optimal performance), FC/PC and SC/PC for general applications and LC and MU for high density applications.





















