Dense Wavelength Division Multiplexing
Dense Wavelength Division Multiplexing
-
Product
PXI 2A Multiplexer, 2-Bank, 4-Channel, 16-Pole
40-614B-014
-
This 2-bank, 4-channel, 16-pole version is part of the 40-614B High Density 2A multiplexer module range that is available in 20 configurations (see Also in this Range link above). All configurations use high quality electro-mechanical signal relays allowing each channel to switch current up to 2A and voltage up to 300VDC/250VAC.
-
Product
LXI Microwave Multiplexer, SP4T, 9-Bank, 18GHz, 50Ω, SMA
60-803-109
-
Our 60-803-109 is a 9 bank terminated SP4T multiplexer and is part of a range of LXI based microwave multiplexers suitable for switching 50 ohm signals up to 18GHz. The 60-803 range is capable of supporting up to 14 banks of terminated 4 channel multiplexers it is ideal for constructing complex microwave switching systems for many applications. Connection is by high performance front panel mounted SMA, SMA-2.9, SMA-2.4 or SMA-1.85 connectors.
-
Product
LXI Microwave Multiplexer, SP4T, 9-Bank, 50GHz, 50Ω, SMA-2.4
60-803-709
-
Our 60-803-709 is a 9 bank terminated SP4T multiplexer and is part of a range of LXI based microwave multiplexers suitable for switching 50 ohm signals up to 50GHz. The 60-803 range is capable of supporting up to 14 banks of terminated 4 channel multiplexers it is ideal for constructing complex microwave switching systems for many applications. Connection is by high performance front panel mounted SMA, SMA-2.9, SMA-2.4 or SMA-1.85 connectors.
-
Product
PXI/PXIe High Voltage Multiplexer, Dual 4-Channel, 2-Pole
42-321-120-HI
-
The 40-321-120-HI (PXI) and 42-321-120-HI (PXIe) are dual 4-channel 2-pole high voltage multiplexers capable of hot or cold switching up to 1000 V peak. They are also available in a range of bank sizes with 1 or 2 poles and channel counts between 4 and 48. High quality reed relays are used throughout.
-
Product
LXI Microwave Multiplexer, SP6T, 8-Bank, 40GHz, 50Ω, SMA-2.92, Terminated
60-800-508
-
Our 60-800-508 is a 8 bank terminated SP6T multiplexer and is part of a range of LXI based microwave multiplexers suitable for switching 50 ohm signals up to 40GHz. The 60-800 range is capable of supporting up to 14 banks of 6 channel terminated multiplexers and is ideal for constructing complex microwave switching systems for many applications. Connection is by high performance front panel mounted SMA, SMA-2.9, SMA-2.4 or SMA-1.85 connectors.
-
Product
PXI/PXIe Microwave Multiplexer, Single SP6T, 26.5GHz, 50Ω, SMA, Remote Mount
40-784B-031-E
-
The 40-784B-031-E (PXI) and 42-784B-031-E (PXIe) are single SP6T 26.5GHz unterminated microwave multiplexers with remotely mounted relays. The 40/42-784B range is available with single, dual or triple, SP6T or SP4T multiplexers with front panel mounted or remotely mounted relays.
-
Product
Single 24-Channel 2-Pole 5 Amp PXI Solid State Multiplexer
40-652-003
-
The 40-652 range of multiplexers uses solid state relays with high tolerance to surge currents and hot switching events. Each multiplexer provides an isolation relay in the common to minimize capacitive loading when expanding the multiplexer across multiple modules. The 40-652 can sustain 30A for 300s on hot or cold switching. User connections are made via a 50-way D-Type connector which is fully support by our comprehensive range of cables and connector accessories.
-
Product
PXI/PXIe High Density 2A Multiplexer, 2-Bank, 16-Channel, 4-Pole
42-614D-012
-
The 40-614D-012 (PXI) and 42-614D-012 (PXIe) 2-bank, 16-channel, 4-pole multiplexers are part of the High Density 2A multiplexer module range available in 23 configurations (see 'Also in this Range' link above). All configurations use high quality electro-mechanical signal relays allowing each channel to switch current up to 2A and voltage up to 300VDC/250VAC.
-
Product
PXI/PXIe High Voltage Multiplexer, Single 48-Channel, 1-Pole
42-321-109-HI
-
The 40-321-109-HI (PXI) and 42-321-109-HI (PXIe) are single 48-channel 1-pole high voltage multiplexers capable of hot or cold switching up to 1000 V peak. They are also available in a range of bank sizes with 1 or 2 poles and channel counts between 4 and 48. High quality reed relays are used throughout.
-
Product
LXI Microwave Multiplexer, 50Ω 6-Channel 6-Bank 26.5GHz SMA
60-801-306
-
The 60-801-306 is a 6-channel, 6-bank RF multiplexer suitable for switching 50Ω signals up to 26.5GHz. It is part of Pickering Interfaces’ range of LXI Microwave Multiplexers which are available with bandwidths between 6GHz and 40GHz and support for 4, 8 12 or 16 banks of 4 or 6-channel multiplexers. It is ideal for constructing complex microwave switching systems for many applications. Connection is by high performance front panel mounted SMA or SMA-2.9 connectors.
-
Product
High Performance LXI Microwave Multiplexers
-
Pickering's LXI Microwave Multiplexers offer the highest density microwave multiplexer configurations possible, packaging 16 multiplexers into a 2U high rack. All versions of this multiplexer have an extremely high level of performance, offering low VSWR, high isolation, low loss and high power handling. Occupying only 2U of valuable rack space - our microwave multiplexers provide a space saving solution for systems requiring high performance multiplexers in the construction of microwave switching systems.
-
Product
PXI 3A Power MUX BRIC, 3-Channel, 16-Pole
40-571-201
-
The 40-571 is a Power Multiplexer designed to simplify the connection of a common set of test equipment to one of a number of different devices for testing (simultaneous multiple channel selection is possible for most configurations, see switching specifications for restrictions). It is ideal for applications where the equipment needs to conduct the same test process on a series of similar devices one at a time. It is available in a variety of configurations that allow testing with differing number of devices to be tested and different connection widths to suit differing test equipment pin counts.
-
Product
PXI Dual SP6T MUX 26.5GHz 50Ω SMA
40-784-032
-
Pickering Interfaces’ 40-784 PXI Microwave Multiplexer Modules have a characteristic impedance of 50 Ohm and are capable of switching signals up to 40GHz. Available in single or dual SP6T or SP4T formats, they are suitable for constructing complex microwave switching networks and provide a range of switching configurations to suit most applications. Connection is by high performance front panel mounted SMA or SMA-2.9 connectors.
-
Product
PXI/PXIe Wide Current Range Multiplexer Module, Single 6-Channel, 4-Pole
42-514-102
-
The 40-514-102 (PXI) and 42-514-102 (PXIe) are low density multiplexers in single 6-channel, 4-pole configuration. They are capable of switching a wide range of current, from 10 μA to 2.5 A at 220 VDC/250 VAC. The current capability of the module permits the use of a single module type for both low and medium current test applications.
-
Product
LXI Microwave Multiplexer, 50Ω 6-Channel 6-Bank 18GHz SMA
60-801-206
-
The 60-801-206 is a 6-channel, 6-bank RF multiplexer suitable for switching 50Ω signals up to 18GHz. It is part of Pickering Interfaces’ range of LXI Microwave Multiplexers which are available with bandwidths between 6GHz and 40GHz and support for 4, 8 12 or 16 banks of 4 or 6-channel multiplexers. It is ideal for constructing complex microwave switching systems for many applications. Connection is by high performance front panel mounted SMA or SMA-2.9 connectors.
-
Product
PXI/PXIe Microwave Multiplexer, Triple SP6T, 50GHz, 50Ω, SMA-2.4
40-785C-553-E
-
The 40-785C-553-E (PXI) and 42-785C-553-E (PXIe) are triple SP6T 50GHz unterminated microwave multiplexers with remotely mounted relays. The 40/42-785C range of multiplexers are available as single or dual, SP6T or SP4T panel mounted multiplexers with relays mounted on the front panel. The single slot version can support up to three supplied remotely mounted multiplexers.
-
Product
PXI/PXIe MEMS Optical MUX, 4-Channel, Multi-Mode, 62.5/125 Fiber, FC/APC Connectors
42-850A-014-M62.5
-
The 40/42-850A-014-M62.5 is a PXI/PXIe 4-channel multiplexer with FC/APC connectors and is part of Pickering's range of PXI Fiber Optic MEMS Switching modules.
-
Product
PXI/PXIe RF Multiplexer, Single 16-Channel, 3GHz, 75Ω, MCX
42-835A-101
-
The 40-835A-101 (PXI) and 42-835A-101 (PXIe) are single 75 Ohm 16-channel RF multiplexers in a single slot. It has been designed to exhibit low insertion loss and VSWR through the use of modern RF relay technology at an affordable cost. The MUX has been carefully designed to ensure excellent and repeatable RF characteristics to frequencies of 3GHz. The design of the 40/42-835A minimizes the injection of noise and unwanted signals into the signal path by careful attention to the mechanical and electrical design.
-
Product
PXIe Microwave Multiplexer, Dual SP4T, 26.5 GHz, 50 Ω, SMA, Failsafe
42-785C-432
-
The 40-785C-432 (PXI) and 42-785C-432 (PXIe) are dual failsafe SP4T 26.5 GHz unterminated microwave multiplexers. The 40/42-785C range of multiplexers are available in single or dual, SP6T or SP4T configurations with relays mounted on the front panel. Remote versions are also available which can support up to three multiplexers in a single slot.
-
Product
PXI/PXIe USB Data Comms Multiplexer, 8-Channel
40-737A-901
-
The 40-737A-901 (PXI) and 42-737A-901 (PXIe) are 8:1 USB multiplexers for switching USB1 and USB2 data and power connections with USB connectors. The data signal paths are 2-pole arranged as differential pairs as defined by the USB standard. The signal pair has a controlled differential impedance and the multiplexer has been designed for minimum insertion loss. The USB power paths are arranged as a common negative and a switched positive. The power paths are designed to ensure minimum loss of the USB power.
-
Product
PXI/PXIe Microwave Multiplexer, Single SP10T, 22 GHz, 50 Ω, SMA, Remote Mount, Failsafe
40-788-131-E
-
The 40-788-131-E (PXI) and 42-788-131-E (PXIe) are single failsafe SP10T 22 GHz unterminated microwave multiplexers with remotely mounted relays. The 40/42-788 range of multiplexers are also available as single or dual, SP8T, SP10T or SP12T panel mounted multiplexers with relays mounted on the front panel.
-
Product
LXI Microwave Multiplexer, SP6T, 11-Bank, 40GHz, 50Ω, SMA-2.92, Terminated
60-800-511
-
Our 60-800-511 is a 11 bank terminated SP6T multiplexer and is part of a range of LXI based microwave multiplexers suitable for switching 50 ohm signals up to 40GHz. The 60-800 range is capable of supporting up to 14 banks of 6 channel terminated multiplexers and is ideal for constructing complex microwave switching systems for many applications. Connection is by high performance front panel mounted SMA, SMA-2.9, SMA-2.4 or SMA-1.85 connectors.
-
Product
PXI Single SP6T MUX 40GHz 50Ω SMA-2.9
40-784-041
-
Pickering Interfaces’ 40-784 PXI Microwave Multiplexer Modules have a characteristic impedance of 50 Ohm and are capable of switching signals up to 40GHz. Available in single or dual SP6T or SP4T formats, they are suitable for constructing complex microwave switching networks and provide a range of switching configurations to suit most applications. Connection is by high performance front panel mounted SMA or SMA-2.9 connectors.
-
Product
PXI/PXIe Microwave Multiplexer, Single SP10T, 18 GHz, 50 Ω, SMA, Terminated, Failsafe
42-788-121-T
-
The 40-788-121-T (PXI) and 42-788-121-T (PXIe) are single failsafe SP10T 18 GHz microwave multiplexers with automatic termination of unused signals. The 40/42-788 range of multiplexers are available as single or dual, SP8T, SP10T or SP12T panel mounted multiplexers with relays mounted on the front panel. Remote versions are also available which can support one or two multiplexers in a dual slot module.
-
Product
PXI/PXIe RF Multiplexer, Single 4-Channel, 3GHz, 75Ω, SMB
42-832A-001
-
The 40-832A-001 (PXI) and 42-832A-001 are 75 Ohm 4 to 1 RF multiplexers with 1 bank in a single slot. They have been designed to exhibit low insertion loss and VSWR through the use of modern RF relay technology at an affordable cost. Each MUX has been carefully designed to ensure excellent and repeatable RF characteristics to frequencies of 3GHz with each path having a nominally equal insertion loss. The design of the 40/42-832A minimizes the injection of noise and unwanted signals into the signal path by careful attention to the mechanical and electrical design.
-
Product
2x16 Channel Multiplexer
FXA-103 MUX 16×2
-
The FXA-103 is a two times sixteen channel multiplexer which allows to route analog or digital input signals from multiple sources to one measurement device. To simplify control the corresponding relays of both multiplexers are switched together and each channel is equipped with a status led. In addition, it is delivered with an installed DIN rail carrier.
-
Product
PXI/PXIe Microwave Multiplexer, Single SP4T, 40GHz, 50Ω, SMA-2.9, Remote Mount
40-785C-441-E
-
The 40-785C-441-E (PXI) and 42-785C-441-E (PXIe) are single SP4T 40GHz unterminated microwave multiplexers with remotely mounted relays. The 40/42-785C range of multiplexers are available as single or dual, SP6T or SP4T panel mounted multiplexers with relays mounted on the front panel. The single slot version can support up to three supplied remotely mounted multiplexers.
-
Product
PXI-2545, 2.7 GHz, 50 Ω, Terminated 4x1 PXI RF Multiplexer Switch Module
778572-45
-
2.7 GHz, 50 Ω, Terminated 4x1 PXI RF Multiplexer Switch Module—The PXI‑2545 is an RF signal multiplexer switch module. The internal termination of the PXI‑2545, which helps prevent high-power reflections that arise from open channels on the module, makes it ideal for use in RF applications where such reflections can damage the source. The module also provides excellent insertion loss, voltage standing wave ratio (VSWR), and isolation parameters to minimize signal degradation. You can use the onboard relay count tracking feature to predict relay lifetime and reduce unexpected system downtime.
-
Product
PXI/PXIe MEMS Optical MUX, Dual 2-Channel, Single-Mode
40-855A-322
-
The 40/42-855A-322 is a PXI/PXIe dual 2-channel multiplexer with MU connectors and is part of Pickering's range of PXI Fiber Optic MEMS Switching modules. They are available in many high density formats with a choice of different connector styles to suit most applications: FC/APC (for optimal performance), FC/PC and SC/PC for general applications and LC and MU for high density applications. They are also available with an optional hardware interlock which, when activated, will return all optical switches to their default unpowered state.
-
Product
PXI/PXIe High Voltage Multiplexer, Dual 4-Channel, 1-Pole
42-321-100-HI
-
The 40-321-100-HI (PXI) and 42-321-100-HI (PXIe) are dual 4-channel 1-pole high voltage multiplexers capable of hot or cold switching up to 1000 V peak. They are also available in a range of bank sizes with 1 or 2 poles and channel counts between 4 and 48. High quality reed relays are used throughout.