Detectors
register the presence of a stimuli.
See Also: Metal Detectors, Particle Detectors, Sensors, Charge Sensitive Preamplifiers, Checkers
-
Product
Capacitive H.V. Detectors (Contact)
213 HVD~226 HVD
-
Standard Electric Works Co., Ltd
Excellent shock resistance. Rugged nylon moulding. Auto on (when voltage detected). Excellent drop resistance. Good vibration resistance. Loud sound alarm indication. Built-in proving and self-test circuit. High bright color-coded LEDS. Works from standard 9V battery. Interchangeable contact electrode. Use in all whether conditions. Compatible with all link sticks. Lightweight, robust & compact. Models available from 11kV to 132kV. Suitable for indoor and outdoor use. Self(auto on) or manual arming. Easy access to batteries. Customized threshold on demand. Auto off (if no voltage detected). Waterproof design, protection class : IP65.
-
Product
Flame Ionization Detector
-
A flame ionization detector converts a hydrocarbon gas concentration into an electrical signal. The flame is hydrogen fueled and burns in hydrocarbon free combustion air. Either side of the flame are two electrodes between which an electric field is generated by means of a polarization voltage. The sample is pre-mixed with the fuel gas and heated in the flame to a temperature at which the hydrocarbon molecules ‘crack’ and CH fragments appear. These CH fragments are oxidated by the oxygen in the combustion air resulting in the formation of CHO+ ions. The ion current then passes to the electrodes and the resulting current measured is proportional to the quantity of C atoms derived from organic compounds.The Thermo-FID features two separate microprocessor controlled pressure compensations to avoid any influence from environmental or sample conditions. In addition, the complete Thermo-FID range of analyzers are equipped with a flame trap that is used as a heated sample inlet filter. The measurement chamber and all material in contact with the sample gas are heated between 120°C and 200°C to avoid condensation.
-
Product
Ultrasonic Leak Detector
ULD-420
-
When equipment begins to fail due to an air or gas leak or vibration, or electrical discharge, the leakage point emits an ultrasonic sound wave that is above the natural range of human hearing. The ULD-420 Ultrasonic Leak Detector converts this ultrasonic sound into a signal that can be used to pinpoint the exact location of the equipment failure. When working in unpressurized systems or the pressure is not sufficient enough to detect or verify a leak with the Receiver alone use the Transmitter.
-
Product
Thermo-Electrically Cooled Dual Mode Analog/Photon Counting Photmultiplier Tube (PMT)
CoolOne
-
For spectroscopy and microscopy experiments in the UV/Vis/NIR region of the spectrum, a photomultiplier tube (PMT) is the ideal detector for quantitative low light level measurements. A PMT is extremely sensitive, with very wide dynamic range so it can also measure high levels of light. PMT’s are also very fast so rapid changes in optical signals can be reliably monitored. As a practical matter, PMT’s are durable, long-lived, and economical.
-
Product
Expert Partial Discharge Detector
XDP-II™
-
The well-established XDP-II™ is a battery-operated portable device allowing partial discharge detection and analysis. The data is saved in its internal memory for local or further analysis on the PC-based XDP-SOFT™. Paired with the proper accessories, the XDP-II™ becomes a powerful solution for many applications such as Cable Joints and Elbows, Switchgear, Offline, Acoustic, TEV, Rotating machines, Transformer, etc…
-
Product
AC Voltage Detector
-
Triplett Test Equipment & Tools
high performance AC Voltage detector with adjustable sensitivity that has a wide measurement range of 25 to 1000ACV, Dual Color Tip to indicate low/high voltage, built-in flashlight and durable overmold. The high sensitivity allows it to detect low voltage AC wiring commonly found in doorbell circuits, thermostats, control circuits, and video surveillance camera power. The Sniff-It 3 is designed for industrial applications with its impact and drop resistance in a sleek ergonomic design, and the easy to use thumb wheel helps dial-in detection range. Includes (2) AAA batteries. CAT III safety rating.
-
Product
Package Leak Detectors
-
Package leak detectors ensure that seal integrity problems are identified. This is a vital part of Modified Atmosphere Packaging (MAP) quality control, since compromising the protective atmosphere will cause a reduction in the shelf-life of MAP products.
-
Product
X-Ray Components
-
Photonis designed the Micro Pore Optics detector to be used in X-Ray imaging applications. Its perfectly square, flat channels are optimized to allow X-Ray and UV photons to be focused or collimated due to the total external reflection at a grazing angle (<2°). Micro Pore Optics are installed on a number of international space missions.
-
Product
X Ray Flaw Detector
-
A non-destructive testing (NDT) device used to inspect materials for internal flaws or defects such as cracks, voids, inclusions, and weld discontinuities.
-
Product
Optical Gas Imaging Camera
FLIR GF620
-
The FLIR GF620 is the first high-resolution, handheld camera from FLIR to detect methane and other volatile organic compound (VOC) emissions. With its ground-breaking 640 x 480 resolution IR detector, inspectors can check thousands of components and safely scan for gases from greater distances. It's also the first FLIR OGI camera to offer Quantification mode (Q-Mode) for streamlined set-up of the optional QL320 gas quantification system.
-
Product
Capacitance Bridge
1620
-
The GenRad 1620-A Capacitance Measuring System is a self-contained assembly of the GR 1615-A Capacitance Bridge with appropriate oscillator and null detector for measurements at 11 frequencies between 20 Hz and 20 kHz. For applications requiring other or higher frequencies, to 100 kHz, the 1615-A bridge can be supplied separately and the oscillator and detector selected to meet your needs.
-
Product
Deep Ultraviolet Spectrophotometer System
VUVAS-10X
-
A new ultraviolet spectrophotometer system for optical metrology just arrived at NASA Goddard! The VUVAS-10X spectrophotometer works best in the 90 to 160 nanometer wavelength range, also known as deep or vacuum ultraviolet (VUV) region. It uses a windowless hydrogen plasma light source and differential pump section to reach many wavelengths beyond those of conventional deuterium lamps. The source also works with other gases, or gas mixtures, for atomic spectral line emission from about 30 nanometers (double ionized Helium gas) up to the Visible light range. The new spectrophotometer system, McPherson VUVAS-10X, uses a one-meter focal length high-resolution monochromator with the special light source, scintillated detector and Model 121 goniometric sample chamber. The system is ideal for optical transmission, absorbance and specular reflectance at incident angles up to 60 degrees. This McPherson spectrophotometer system will help develop, inspect and qualify optical materials and coatings used for very high altitude and extraterrestrial space flight missions.
-
Product
Broadband Detectors
-
These waveguide bandwidth detectors use silicon beam lead diodes on a planar stripline circuit to obtain an extremely rugged and compact device. Most millimeter wave broadband detectors have very poor VSWR due to the difficulty in obtaining a good wideband impedance match to the diode. To overcome this problem, these detectors utilize two diodes and an internal matched termination and 3 dB hybrid as shown below. This circuit allows a VSWR of 2.0 or better over a full waveguide bandwidth for most of these detectors. Detectors for waveguides WR-8 and smaller use a single zero bias GaAs diode. The high sensitivity zero bias GaAs diodes can also be special ordered for use at lower frequencies when highest sensitivity is required.
-
Product
Phase Rotation Indicator DX2
-
STB Electrical Test Equipment, Inc
From the company who builds the popular analog ground fault detector comes the newest phase rotation indicator on the market. No other manufacturer offers a phase rotation indicator like STB's DX2 that will read up to 5kV! The phase rotation indicator is used to determine the phase sequence of three-phase voltages. This meter is most commonly used for phasing-in a power line which has supplied power to motors and plants. It is essential for testing departments of public utility systems for laboratory and field testing. The convenient and durable carrying case allows user to safely transport the unit to wherever the job takes them.
-
Product
Photon Counting PMT Detection System
-
For spectroscopy and microscopy experiments in the UV/Vis/NIR region of the spectrum, a photomultiplier tube (PMT) is the ideal detector for quantitative low light level measurements. A PMT is extremely sensitive, with very wide dynamic range so it can also measure high levels of light. PMT’s are also very fast so rapid changes in optical signals can be reliably monitored. As a practical matter, PMTs are durable, long-lived, and economical.HORIBA provides a simple, self contained PMT housing that operates in either analog or photon counting modes with the flick of a switch. This ambient PMT housing is ideal for standard side-on PMTs that are used from 185 to 900 nanometers. It has a very low dark count for a non-cooled PMT housing providing a dark count of only ~ 50 to 500 counts per second (cps) depending on the PMT selected.
-
Product
Data Acquisition Control Boards
X-GCU
-
X-GCUs are a data acquisition and control boards of Detection Technology’s digital X-ray detector platforms. X-GCU together with the digital X-Cards provide complete and easily scalable detector subsystems shortening time-to-market and delivering total cost savings for all types of X-ray imaging systems.
-
Product
Holiday Detector
266
-
The Elcometer 266 Holiday Detector revolutionises high voltage DC testing of coatings porosity detection making it safer, easier and more reliable than ever before.
-
Product
Planar-Doped Barrier Diode Detector, 0.01 to 33 GHz
8474C
-
The Keysight 8474C is a high-performance detector using a gallium arsenide, planar-doped barrier detecting element. It features extremely flat frequency response over its entire band of operation and very good frequency response stability versus temperature. The Keysight 8474C is also very rugged with high resistance to ESD damage. The Keysight 8474C detector is available with a 3.5-mm (mates with SMA, 0.01 to 33 GHz) connector. This detector offers the options for optimal sqaure-law loads (Option 102) and for positive polarity output (option 103). Because the unit-to-unit frequency response tracking of this device is typically better than 0.3 dB, no matched response option is offered.
-
Product
Platinum and Nickel RTD Temperature Sensors
-
Accurate, repeatable and robust resistance temperature detector (resistance thermometers) sensor assemblies manufactured provide fast temperature response and can be applied in most temperature measurement and control applications.
-
Product
Viscometer
ViscoStar III
-
A highly sensitive, on-line differential viscometer used in conjunction with SEC-MALS to determine the size and conformation of all types of biopolymers, synthetic polymers and even proteins and peptides. The ViscoStar III incorporates multiple novel technologies to provide the highest sensitivity, stability and solvent compatibility of any available viscometer for GPC. Its ease-of-use and serviceability make it the perfect companion for Wyatt's DAWN HELEOS II light scattering and Optilab T-rEX refractive index detectors.
-
Product
Hall Probes and Magnetic Pole Detector/Identifier
-
ChenYang Technologies GmbH & Co. KG
Is the new generation of the pole detector CY-PD248. It ispowered with one battery (1.5V, type AAA). The continuous operation time of the battery is longerthan 10 hours. The minimum detectable magnetic field is 9mT (90Gs).
-
Product
Radiometer
X1-1-RCH-116-4
-
The X1-1 radiometer from Gigahertz-Optik features an RCH-116-4 detector and is ideal for measurement of the irradiance of high power LEDs in the UV-A and blue light range. The device can accurately measure irradiance levels of up to 40,000 mW/cm². One of the outstanding features of the RCH-116-4 detector is its proven concept of a passive radiation absorber coupled to a UV sensor. This provides stability even in high temperature and intense UV radiation environments. In addition to the passive radiation absorber, the device also has a cosine-corrected field of view. The sensor’s housing also serves as a handle. The battery-powered X1-1 optometer supports a usable dynamic range from less than 1 mW/cm² to 40,000 mW/cm² thanks to its high-end signal amplifier. It can be used to perform precise measurements of up to 5 standard LED wavelengths for which the detector was calibrated for active irradiance. In addition to the CW measurement function, the device also has a dose measurement function. The radiometer can be used with other detectors from the RCH series. e.g. for gas discharge lamps. Remote control of the device is possible via its user software and a software development kit is offered for integration of the device in the user’s own software.
-
Product
Enameled Wire Portable Pinhole Tester
-
Shanghai Dean Electrical Co., Ltd
DZK high and low voltage (portable) pinhole detector is designed and produced in accordance with GB/T4074.5-2008 standard, and can be used by users to monitor the continuous performance of the paint film of the product in real time during production and use. . It takes into account the detection function of the traditional high-voltage paint film continuity tester, and the advantages of being easy to move and replace the use position (the whole machine weight is less than 5KG and can be equipped with lithium batteries), which is convenient for users to detect multiple environments and multiple cables. use.
-
Product
Photometric Detector head / very low light level
VL-3707
-
To meet the demands of the increasing number of very low light level applications, Gigahertz-Optik has introduced the VL-3707 precision photometric detector capable of accurate measurements down to less than 100 μlux.
-
Product
sbRIO-9218, Non-Enclosed, 24-Bit, 51.2 kS/s/channel, 2-Channel C Series Universal Analog Input Module
783362-02
-
Non-Enclosed, 24-Bit, 51.2 kS/s/channel, 2-Channel C Series Universal Analog Input Module - The sbRIO‑9218 helps you perform multipurpose testing. With the sbRIO‑9218, you can measure signals from sensors such as strain gages, resistance temperature detectors (RTDs), thermocouples, load cells, and other powered sensors. You also can use the sbRIO‑9218 to perform quarter-bridge, half-bridge, and full-bridge current measurements, with built-in voltage and current excitation. You can individually select and perform a different measurement type on each channel. Additionally, the sbRIO‑9218 features 60 VDC analog input isolation. Non-enclosed modules are designed for OEM applications.
-
Product
Radiometric Detectors - Clinical
-
Designed for use in regulated environments. It comes with 5 or 10 detectors (each with 550-sample capacity), and 5 and 10 detectors (each with 1,000-sample capacity).
-
Product
Evaporative Light Scattering Detector for HPLC
ELSD-LT III
-
The evaporative light scattering detector (ELSD) is a general-purpose universal detector that can even detect components with no UV absorption, such as carbohydrates, lipids, surfactants, and synthetic polymers. With exceptional sensitivity, a wide dynamic range through Analytical Intelligence features, and easy operability using LabSolutions™ software, the ELSD-LT III contributes to more effective analysis in a wide variety of fields.
-
Product
Photoluminescence Spectrometer
FLS1000
-
The FLS1000 sets the standard in both steady state and time-resolved photoluminescence spectroscopy for both fundamental research and routine laboratory applications. The system is a modular fluorescence and phosphorescence spectrometer for measuring spectra from the ultraviolet to the mid-infrared spectral range (up to 5,500 nm), and lifetimes spanning from picoseconds to seconds. All of this can be achieved through various upgrade routes, either at the time of order or in the future. Whether you are studying photophysics, photochemistry, biophysics, biochemistry, material or life sciences, the FLS1000 will enable you to reliably and accurately measure luminescence spectra and kinetics using state-of-the-art sources, detectors, acquisition techniques, quality optics and precision mechanics. The large sample chamber will house practically any type of sample accessory.
-
Product
Non-Contact Type Phase Sequence Indicator
890 PR
-
Standard Electric Works Co., Ltd
● The 890 PR is a Non-Contact phase detector with flashing LEDs and a beeping buzzer to show the detection of AC 3-phase sequence.● Two functions in one unit : open phase and phase sequence detection.● Convenient brightness switch to make the indication visible in dim areas or sunlight.● Back cover magnets which attach the instrument to the AC distribution panel offer easy measurement. ● 3-Phase AC 75 to 1000V is fitted for detection.● Conductor size: 1~35mm● Detect frequency range is from 45 to 65Hz.
-
Product
Bi-Directional-Coaxial LD/PD Module
BiDi-C1000 (CWDM)
-
Hangzhou Huatai Optic Tech. Co., Ltd.
*Tx Laser wavelengths optical : 17 CWDM *Using DFB Lasers *DFB laser optical: with isolation or without isolation *Low threshold current and operating current* High output power *Built-in InGaAsP monitor PD* High responsivity, InGaAs planar PIN detector *Wide temperature range operation(Tc=-40℃to+85℃) *Fiber ITU-T G.657 Bending low loss, fiber optic cable features