Frequency Standards
Devices that produce a known frequency.
See Also: Hydrogen Frequency Standards, Rubidium Standards, GPS Clocks
-
Product
Standard 2.00 (57.00) - 4.00 (113.00) General Purpose Probe
P2757G-1W1S
General Purpose Probe
Current Rating (Amps): 20Average DC Resistance lower than (mOhm): 10Test Center (mil): 187Test Center (mm): 4.75Full Travel (mil): 230Full Travel (mm): 5.84Recommended Travel (mil): 167Recommended Travel (mm): 4.24Overall Length (mil): 1,210Overall Length (mm): 30.73Overall Length Remark: Tip 2C: 1140 mil (28.96 mm) Tip 1W: 1205 mil (30.61 mm) Tip 2W: 1205 mil (30.61 mm)
-
Product
Frequency Converter Unit
FCU
-
The Astronics Frequency Converter Unit (FCU) provides frequency conversion of variable frequency aircraft power. Recent trends in aircraft power systems use variable frequency (VF) generators instead of fixed frequency of 400Hz. While the majority of aircraft loads can use VF power, select loads still exclusively require 400Hz and are best addressed by the use of FCUs. The FCU performs the task of converting the power line frequency by leveraging recent advances in solid-state technology to provide dramatic improvements in performance over traditional frequency converter solutions.
-
Product
Xytronic Single-Phase Reference Standard +/- 0.04%, +/- 0.02%, +/- 0.01%
RADIAN RX-20, RX-21 and RX-23
-
Radian Research is committed to providing our customers with leading innovative and technologically superior products, while maintaining metrology capability in power and energy measurement that is surpassed by none. Our engineers drew on the expertise and knowledge we acquired for our industry-leading legacy RM (Metronic) and RD (Dytronic) reference standards to develop the RX (Xytronic), the ultimate in power and energy measurement technology perfection.
-
Product
Standard 0.79 (23.40) - 1.75 (49.60) General Purpose Probe
HPA-40B
General Purpose Probe
Current Rating (Amps): 2Average Probe Resistance (mOhm): 35Test Center (mil): 39Test Center (mm): 1.00Full Travel (mil): 75Full Travel (mm): 1.91Recommended Travel (mil): 50Recommended Travel (mm): 1.27Mechanical Life (no of cyles): 1,000,000Overall Length (mil): 660Overall Length (mm): 16.76
-
Product
Standard 2.00 (57.00) - 4.00 (113.00) General Purpose Probe
P2757G-2W1S
General Purpose Probe
Current Rating (Amps): 20Average DC Resistance lower than (mOhm): 10Test Center (mil): 187Test Center (mm): 4.75Full Travel (mil): 230Full Travel (mm): 5.84Recommended Travel (mil): 167Recommended Travel (mm): 4.24Overall Length (mil): 1,210Overall Length (mm): 30.73Overall Length Remark: Tip 2C: 1140 mil (28.96 mm) Tip 1W: 1205 mil (30.61 mm) Tip 2W: 1205 mil (30.61 mm)
-
Product
Nanoscale Microscopy Standards
-
The nanoscale AFM-CD standard (CD, critical dimension) contains structures to calibrate line widths and periods of AFM (atomic force microscopy) devices.
-
Product
Standard Pitch Spring Probes
-
Other than spring probes with gold plating, we have spring probe with anti-solder migration coating and plating that were developed by KITA. We also have anti-solder migration material for plunger tip. These are all included in “MARATHON” series. They have wide range of tip type for various use for every popular total length.
-
Product
Frequency Meter
-
Shenzhen Graigar Technology Co.,Ltd.
A frequency meter is an instrument that displays the frequency of a periodic electrical signal. Various types of frequency meters are used. Many are instruments of the deflection type, ordinarily used for measuring low frequencies but capable of being used for frequencies as high as 900 Hz.
-
Product
Frequency Synthesiser
RA062-F2
-
The RA062-F2 is a multiple LO module used to generate three pairs of LO signals, each pair being phase matched in order to provide the capability to drive two phase and amplitude matched, high sensitivity narrowband receivers such as might be required for an EW receiver system with DF functionality.The Stepped Frequency Synthesiser is based upon Direct Frequency Synthesis, DFS, whereby the 1GHz input reference signal is multiplied, filtered and mixed to generate a given number of isolated and filtered single tone CW signals from the 1GHz comb. A finely tuned signal is then generated using a multi-way switch to select between the 1GHz spaced CW tones and mixed with fine resolution signals generated using a custom DDS/VCO PLL network. In this way finely tuned signals can be generated between 7.5GHz and 23GHz.
-
Product
Standard High Speed D/A Converters
-
Analog Devices digital-to-analog converter (DAC) portfolio provides solutions for your high speed and precision DAC applications. Thanks to complete data sheets and evaluation boards, as well as broad support among our clock and timing, RF, power management, and op amp portfolios, our DACs can help you reduce time to market and system design costs. A high speed range from 30 MSPS to multi-GSPS, 8- to 16-bit resolution, and a tiny package are just some of the features that make our industry-leading d/a converters stand out.
-
Product
Standard 1.50 (43.00) - 3.00 (85.00) General Purpose Probe
P2665G-1W1S
General Purpose Probe
Current Rating (Amps): 15Average DC Resistance lower than (mOhm): 10Test Center (mil): 125Test Center (mm): 3.18Full Travel (mil): 230Full Travel (mm): 5.84Recommended Travel (mil): 167Recommended Travel (mm): 4.24Overall Length (mil): 1,290Overall Length (mm): 32.77Overall Length Remark: Tip 2W: 1270 mil (32.26 mm)
-
Product
PCI Standard Programmable Resistor Cards
-
Pickering's PCI Standard Programmable Resistor Cards include fully programmable resistor and potentiometer cards for applications such as sensor emulation that require fine adjustment with a resolution down to 0.25 Ohm. All of our Programmable Resistor Cards can easily be formed to make Programmable Potentiometers by connecting two channels in series, using the unconnected terminals as the A and B connections and the link between the two channels as the wiper connection.
-
Product
Standard 0.62 (18.00) - 5.40 (153.00) Probe
LFRE-39L15-5.4
ICT/FCT Probe
Current Rating (Amps): 2Average Probe Resistance (mOhm): 50Test Center (mil): 75Test Center (mm): 1.91Full Travel (mil): 250Full Travel (mm): 6.35Recommended Travel (mil): 167Recommended Travel (mm): 4.24Mechanical Life (no of cycles): 50,000Overall Length (mil): 1,437Overall Length (mm): 36.50
-
Product
Frequency Ranges
1398A
-
The useable frequency range is from 5 Hz to more than 10 times higher than that listed in the table below, e.g. T2.5-1 volt and T5-2 volt can be used beyond 10 MHz.
-
Product
MOSFETs For High Frequency Amplifier
-
The MOSFETs shown below are best suited for amplification of high-frequency signals.
-
Product
Standard 0.79 (23.40) - 1.75 (49.60) General Purpose Probe
HPA-40A
General Purpose Probe
Current Rating (Amps): 2Average Probe Resistance (mOhm): 35Test Center (mil): 39Test Center (mm): 1.00Full Travel (mil): 75Full Travel (mm): 1.91Recommended Travel (mil): 50Recommended Travel (mm): 1.27Mechanical Life (no of cyles): 1,000,000Overall Length (mil): 660Overall Length (mm): 16.76
-
Product
Single Frequency Lasers
-
A single-frequency laser is a type of laser which operates within a singular resonator mode, achievable when the net gain bandwidth of the laser remains narrower than the frequency spacing of the resonator modes. In cases where the mode spacing isn’t adequately large to support a single resonator mode, single-frequency operation is maintained through the utilization of intracavity filters. This enables the single-frequency laser to possess an exceedingly narrow linewidth, frequently measuring only a few kHz, and an extended coherent length. A clear association exists between the coherence length and the spectral width of the laser.
-
Product
Standard Gain Horn Conical Lens antennas
-
Elva’s SLHA series of standard gain horn lens antennas cover the frequency range of 18 to 220 GHz in ten waveguide bands. They can be issued with rectangular or circular waveguide. Lens technology significantly allows decreasing mechanical sizes of horns and correcting beam for the best performance. These horns are ideal solution for measurement gain of other antennas, short range radars and radiometers.
-
Product
Variable Frequency Modules
9554-( )
-
Utilizing the high voltage power source in the Model 9354-1 Universal Transient Generator, four individual modules can be connected to provide tuning of damped sine waves from 10 KHz to 50 MHz. A fifth module is available which, when used in conjunction with the Model 9354-1, provides 20% frequency steps from 30 MHz to 100 MHz
-
Product
Primary Standards
-
Primary standards (often also referred to as mechanical dead-weight testers, pressure balances or primary pressure standards) are the most accurate reference instruments for pressure. Their functional principle is based on the physical principle of pressure = force/area. Mass pieces placed on the top of a piston-cylinder system are the source of a precisely defined force. By producing a certain (counter) pressure inside the primary standard an equilibrium is achieved: the mass pieces, including the free-running piston of the piston-cylinder system, are floating, which will lead to a very accurate pressure at the test port which measured through piston gauge technology.
-
Product
Frequency Expansion Modules
-
bsw TestSystems & Consulting AG
Up To 1.5THz For Network Analyzers Modern communication standards, like for instance 5G, place high demands on components (mixers, amplifiers, antennas, etc.), which have to be examined in high frequency bands (millimeter waves); the requirements include: broad frequency coverage, sufficient output power to operate the components under compression, high dynamic range and stability as well as a reduced dynamic content within the spectrum.
-
Product
CPCI-S.0 Standard Compliant Peripheral Carrier Board
MIC-3810
Carrier Board
The carrier board provides a PCIe x16 connector for standard PCIe x8, PCIe x4, PCIe x1 PCIExpress® cards supporting PCIe Gen3 speeds. The carrier board can accommodate cards with maximum dimensions of 176 x 68.9 mm (6.9" x 2.7" inches).
-
Product
Audio Frequency System
Locator Set / UL 30
-
Cable fault location with the BAUR Locator Set / UL 30. The audio frequency system Locator Set is used to exactly determine the alignment of cables and metal gas or water pipes. With various accessories, this system becomes a universal, indispensable device for power companies, industries, installation companies and water suppliers.* Output energy up to 50 VA* Automatic or manual impedance adjustment* Charging unit and rechargeable battery integrated; battery or mains operation* Continuous or cyclical output
-
Product
Standard Amplifiers
-
Teledyne RF & Microwave, a Business Unit of Teledyne Microwave Solutions (TMS), supplies catalog and custom RF and microwave amplifier designs for aerospace, defense, and industrial applications. These standard amplifiers, originally designed by Teledyne Cougar, provide both excellent stability and cascadability.
-
Product
Standard 1.10 (31.00) - 3.85 (109.00) General Purpose Probe
HPA-64-10
General Purpose Probe
Current Rating (Amps): 3Average Probe Resistance (mOhm): 50Test Center (mil): 100Test Center (mm): 2.54Test Center Remark: max. test center 187 mil / 4,74 mmFull Travel (mil): 50Full Travel (mm): 1.27Recommended Travel (mil): 50Recommended Travel (mm): 1.27Mechanical Life (no of cyles): 1,000,000Overall Length (mil): 375Overall Length (mm): 9.53Overall Length Remark: Exact length depends on selected tip: Tip 1,4, 7: 0,375″; Tip 2,3,9,10: 0,365″; Tip 8: 0,385″
-
Product
WR3.4 Frequency Extension Solution, 220-330 GHz with VDI Extender Modules
CobaltFx 220 to 330 GHz
-
CobaltFx cost-effective millimeter wave frequency extension system allows you to build a scalable and affordable 5G testing solution.
-
Product
Standard 0.70 (2.00) - 1.70 (4.80) General Purpose Probe
P2262AG-1C1S
General Purpose Probe
Current Rating (Amps): 3Average DC Resistance lower than (mOhm): 30Test Center (mil): 50Test Center (mm): 1.27Full Travel (mil): 90Full Travel (mm): 2.29Recommended Travel (mil): 67Recommended Travel (mm): 1.70Overall Length (mil): 710Overall Length (mm): 18.03
-
Product
40-72 GHz Doubler
1GC1-8048
Frequency Extender
The 1GC1-8048 is a balanced diode frequency doubler consisting of two Schottky diodes and a coplanar balun structure. The doubler provides 15 dB conversion loss and 17.5 dBc 1st and 3rd order feed-thru for input frequencies between 20 and 33.5 GHz. This IC is fabricated in HFTC's InGaP/GaAs heterojunction bipolar transistor (HBT) process that provides excellent uniformity, reliability and 1/f noise performance.
-
Product
Standard In-door Forward Optical Receiver
HR8636
-
Hangzhou Huatai Optic Tech. Co., Ltd.
HR8636 with standard configuration is a type of high index and universal in-door forward optical receiver. It adopts Philip optical receiving module. End-grade adopts power-doubling module. Optical connectors and RF connector can be installed at the front panel or back panel.
-
Product
Standard 1.68 (48.00) - 3.20 (91.00) General Purpose Probe
HPA-52D
General Purpose Probe
Current Rating (Amps): 3Average Probe Resistance (mOhm): 15Test Center (mil): 75Test Center (mm): 1.91Full Travel (mil): 75Full Travel (mm): 1.91Recommended Travel (mil): 75Recommended Travel (mm): 1.91Mechanical Life (no of cyles): 250,000Overall Length (mil): 629Overall Length (mm): 15.98





























