Ground Leakage
is unwanted current flowing to ground.
-
product
Static Grounding for Process Plant & Equipment
Earth-Rite MULTIPOINT II
The Earth-Rite® MULTIPOINT II is a unique multi-channel static grounding system that can monitor the simultaneous grounding of up to eight (8) individual pieces of equipment at risk of discharging electrostatic sparks.
-
product
Earth Leakage Breaker And Residual Current Device
IGR Series
IGR Leakage Current Analyzer is invented as the world first, and also can measure Insulation Resistance (MO) without power cut-off. This patented instrument can analyze leakage current, and display Igr(resistive), Igc(capacitive), and Io(vector sum), Ground Insulation Resistance, and the phase angle between voltage and current. (IGR ELB) - Operates due to Igr. - Properly-operating in spite of IGC in digital era. ( Not tripping on UPS load and Harmonics and noise area) - Possible to go down Igr for safety of people and animals. - Possible to manufacture high sensitive ELB. - Possible to prevent fire from electric leakage current.
-
product
Clamp on AC Leakage Current Sensors
High Accuracy Clamp AC Leakage Sensor use permalloy magnetic cores, with small size, high accuracy, good stability, strong anti-interference ability characteristics. It is applied with double shield technology, which insure strong anti-interference ability.
-
product
Ground Earth Resistance Tester
2678X
Shenzhen Chuangxin Instruments Co., Ltd.
Ground Earth Resistance Tester verifies the integrity (continuity) of the protective bonding of the equipment (Class I equipment) designed to secure safety through the basic insulation and protective earthing. It is also called earth (ground) bonding test. If the continuity of the protective bonding is confirmed, we can conclude that the equipment has the requirements for preventing electric shock even if the insulation between the primary circuit and the accessible conductive section fails and a fault current flows through the distribution system.
-
product
Ground Fault Locator
DC Trace
SCOPE introduces DC Trace, the most advanced and user friendly DC Earth (Ground) Fault Locator. This portable instrument consisting of Signal Generator & Signal Receiver (DC TraceR) uses latest digital signal processing technology. It’s ability to detect earth faults in live DC system quickly & accurately in online condition greatly relieves the substation maintenance engineers from nightmare of earth leakages & it’s detection.
-
product
AC Ground Bond Tester
448
Our 448 model is a 4-in-1 tester with 500VA AC Hipot, DC Hipot, Insulation Resistance and Ground Bond testing capabilities. The 448 is capable of a 500VA AC Hipot output to comply with 100mA leakage current test compliance requirements. This tester features a simple design and easy-to-use interface, reducing setup time and increasing production-line throughput for your application.
-
product
Electrolytic Capacitor Leakage Current Meter
TH2686N
Changzhou Tonghui Electronic Co., Ltd.
■ Test voltage: 0-200V, 0-500V ■ Voltage accuracy: 1% set value + 1 word ■ Measuring range: 10nA-19.99mA, resolution: 1nA ■ Current accuracy: 2% reading + 2 words ■ Intelligent type, microprocessor control
-
product
Ground Resistance Tester
2521
Shenzhen Chuangxin Instruments Co., Ltd.
High measuring accuracy, high speed, easy to use, especially suitable for using in laboratory and automatic testing line. Test current AC / 5 ~ 30 (a), resistance Ω (0 ~ 600 m), time (1 ~ 99 s) shows at the same time. Test time can be arbitrary setted. Test alarm value can be arbitrary set up. Pass/fail sound and light alarm.
-
product
Below Ground Insulator Tester
CE-IT
The CE-IT gives fast and accurate testing of below ground insulators and road crossing casings. This fully automatic unit tests the insulator without any adjustment by the operator needed.
-
product
For Detecting Low Range And Leakage AC/DC/Pulsed Current.
FDAZCT-20L-0.6S
MULTI MEASURING INSTRUMENTS Co., Ltd.
*Lowest Influence from Magnetization,Temperature *Change,Residual Current and Terrestrial Magnetism.*Low Cost and High Performance (Output Linearity ±1% F.S)
-
product
Cylinder Leakage Tester Kit
CLT200
Quickly locates internal engine problems such as bad rings, valves and leaking head gaskets. Dual 2-1/2" heavy duty gauges with protective outer boots. Scales read 0-100psi and 0-700 kg/cm2Pressure regulated manifold includes high quality quick couplers for fast set-ups.
-
product
3U VPX 6 Slot Power & Ground 10G Pass Through
101VPX306P-9X12R
Power for 3.3V, 5V and 12V are included, rear connectors are all fully loaded, use with Elma’s slot to slot or slot to I/O bulkhead cable products during system development.
-
product
12-bit, 4 Analog Voltage Outputs With Separate Grounds, Optically Isolated 500 V
APCI-3504
4 analog output voltage channels with 500V optical isolation, 12-bit resolution, each output has its own ground line.
-
product
Magnetic Flux Leakage Testing
PRÜFTECHNIK Condition Monitoring GmbH
NOVAFLUX - Flux Leakage Inspection for Black or Bright Steel Bars
-
product
DC Earth Leakage Current Measurement
DCZCT-11M
MULTI MEASURING INSTRUMENTS Co., Ltd.
*DC Earth Leakage Current Measurement *Bipolar DC ±12V Power Supply*Output DC ±1.5V at DC 10mA *Isolated Housing Case based on UL94V-0*Through Hole PCB Mount Type, Exciting Current Method
-
product
Field Ground Module
SEL-2664
Schweitzer Engineering Laboratories, Inc.
Add the SEL-2664 Field Ground Module to the SEL-300G or SEL-700G to protect all the critical components in your generator with one comprehensive relay. Or, add the SEL-2664 to the SEL-2664S to complete ground fault protection on both the rotor and stator.
-
product
Personal Grounding Testers
Wolfgang Warmbier GmbH & Co. KG
The test result is indicated with audible and visual signals. A relay with a dry contact provides the connection to a door opening system
-
product
Ground Testing
Ensuring an effective earth system is essential in a telecommunications system, and Megger is expert in earth testing having been there right from the start. These days Megger offers top end systems for design and soil surveys as well as tough easy to use testers for field engineers. We have tried to make the testers self checking as much as we can, to allow you to concentrate on collating and understanding the results.
-
product
AC & DC Analog Leakage Meters
507 EL
Standard Electric Works Co., Ltd
● Optional for pivot or taut band movement.● Compact and lightweight; easy to use and store.● Mirror scale: for easier viewing & reading.● Built-in stand makes reading and measuring easy.● 200μA full scale value.● Fuse-protected.● Low battery indication.
-
product
Common Point Ground Connector
Q007-T
The Prostat Q007B Qube™ replaces ordinary electrical grounding devices with a convenient, cost effective means to connect several ESD controls to a single grounded electrical outlet. Use the Q007B Qube™ to ground workstations, mats, wrist strap & testers, instruments, and other ESD control products to a pre-tested facility electrical ground. It consists of a robust multi receptacle frame encased in fire retardant ABS with a solid brass grounding pin.
-
product
3U VPX 1 Slot Power & Ground
101V301P03-9003R
Power for 3.3V, 5V and 12V are included, rear connectors are all fully loaded, use with Elma’s slot to slot or slot to I/O bulkhead cable products during system development.
-
product
AC Ground Bond Testers
440 Series
The 440 Series provides advanced 4-in-1 test capability in a convenient one-box solution. This new series performs AC Hipot (448 - 500 VA), DC Hipot, Insulation Resistance and 40A AC Ground Bond tests while taking up minimal production line space. The 440 Series is simple and easy-to-use; reducing setup time and increasing production line throughput for your application. With multiple memories and an optional USB port for remote BUS communication so you can quickly perform tests on a variety of DUTs from the front panel or with a PC. Learn about our 5 Year Warranty.
-
product
Battery Ground Detector
BGD
Battery Ground Detectors supply contact closures for alarm indications at precise ground fault resistance settings.
-
product
Resistance Grounded Systems (HRG/LRG)
Neutral Grounding Resistors (NGRs) are used to limit the maximum ground-fault current. Restriction of fault current lowers hazards and reduces damage done to equipment. High Resistance Grounding (HRG) systems are often used on industrial and critical power applications to maintain system uptime during a first ground fault. HRG systems are also used in tripping applications to help control touch potential on portable loads and improve personnel safety.
-
product
Leakage Current Clamp Mete
Basic functions:AC current:20mA resolution: 0.01mA, ± (2.5%, +5)200mA resolution: 0.1mA, ±(2.5%, +5)2A resolution: 1mA, ±(2.5%, +5)60A resolution: 100mA, ±(3%, +8)AC voltage: 600V, ±(0.8%, +5)DC voltage: 600V, ±(0.8%, +5)Special functions:Auto ranging Low battery display Data hold Auto power-off Over-load protection Input impedanceDC voltage measurement: ≥10MΩ Sampling frequency: 3 times/s Maximum display: 1999 Maximum distance between clamps: 30mm General characteristics:Product colors: iron-gray and redProduct net weight: approximately 136gLCD size: 25x36mmProduct size: 183x63x29mmPower: 2x1.5V, 7#Standard accessories: packing carton and handheld bag English user's manual and battery
-
product
Power Quality, Ground Resistance & Insulation Testers
Improving energy efficiency, reducing downtime, and prolonging the life of your equipment are some of the ways you can save money with Amprobe tools.
-
product
Line Leakage Tester
LineCHECK II
Designed for Automated Test ApplicationsFull Compliment of Automation InterfacesComplete Line Leakage Testing SolutionEnhanced Graphic LCDCompatible with Scanning Matrix for Patient Lead TestingContinuous Run FeatureSoftware CompatibleSafety Agency Listed





























