Vapor
-
Product
CVAF – Cold Vapor Atomic Fluorescence
-
Cold Vapor Atomic Fluorescence (CVAF) is a powerful technique based on detecting fluorescence light emitted by the sample. Below the principle of the technique is explained in a nutshell.
-
Product
Reid Vapor Pressure On-Line Analyzer
MiniVap On-Line RVP Analyzer
-
MINIVAP ON-LINE is a process monitoring analyzer for the determination of the vapor pressure of gasoline, crude oil, LPG and NPG. Also, the vapor-liquid ratio (LVR) of gasoline can be measured. The measuring principle is identical to the worldwide used laboratory instruments MINIVAP and therefore the MINIVAP ON-LINE produces equivalent results.
-
Product
Water Vapor Transmission Rate WVTR Tester
WPT Series
-
Water Vapor Permeability Tester is based on the Gravimetric method and is applicable to the water vapour transmission rate (WVTR) test of plastic films, composite films, sheets and other materials.
-
Product
Water Vapor Permeability Tester
QT-WVP
-
Qualitest Water Vapor Permeability Tester QT-WVP series is used to test the water vapor transmission rate (WVTR) of packaging materials.
-
Product
Vapor Pressure Tester
-
The MINIVAP laboratory and process vapor pressure analyzers are the worldwide accepted standard instruments for the determination of the vapor pressure of gasoline, crude oil and LPG.
-
Product
Dual Vapor Gravimetric Sorption Analyzer
DVS Resolution
-
DVS Resolution’s key feature is the combined ability to precisely control and measure temperature and relative humidity while recording the highest resolution changes in mass. DVS Resolution uses a dry carrier gas typically nitrogen or compressed air for its operation. Digital mass flow controllers regulate flows of dry and saturated gases. Relative humidity is generated by precisely mixing dry and saturated gas flows in desired flow ratios which produce expected relative humidity. In a typical experiment a known concentration of water vapor is delivered over a sample placed inside the sample pan connected to the Surface Measurement Systems Ultrabalance™ measuring realtime mass changes caused by sorption or desorption of water molecules. Prior to sorption measurements, the sample can be in-situ preheated/dried at temperatures of up to 300oC.
-
Product
Vapor Relays & Contactors
-
From rail passenger cars and locomotive control and starting circuits to earth moving equipment, Vapor relays and contactors have established a reputation for quality and reliability where dependable control of DC circuits is required. Performance-proven in thousands of applications worldwide, Vapor relays and contactors meet or exceed stringent qualification requirements of major locomotive and rail passenger car builders and heavy machinery manufacturers. Units are in daily service on U.S. Class 1 railroads, the New York City Transit Authority, the Chicago Transit Authority, the Toronto Transit Commission and other railroads and transit agencies around the globe.
-
Product
Cold Vapor Atomic Fluorescence (CVAF) Mercury Analyzer
QuickTrace M‑8000
-
The QuickTrace® M-8000 Cold Vapor Atomic Fluorescence (CVAF) mercury analyzer is ideal for ultra-trace to sub-mg/L mercury quantitation. Due to the high sensitivity of the M-8000, it easily achieves the ultra-trace detection limit of <0.05 ng/L total mercury that is demanded by customers following EPA method 1631. The QuickTrace® M-8000 is also versatile enough to analyze samples >400 µg/L without dilution in a research or industrial setting.
-
Product
Dynamic Vapor Sorption Analyzer
IGAsorp-CT
-
The IGAsorp-CT is a fully automated dynamic vapor sorption analyzer for the measurement of water and organic solvent isotherms and kinetics on a wide range of materials. Operating at temperatures from 5 to 85 °C and humidity values from 0 to 98 %RH, the IGAsorp-CT offers the widest combined range of any DVS analyzer. An optional internal heater allows fully programmable pre-heating and thermal desorption measurements to 350 °C.
-
Product
Heat, Vapor, and Carbon-Dioxide Flux Sensors
-
Heat, vapor, and carbon-dioxide flux sensors are typically used in eddy-covariance systems to measure exchanges of carbon dioxide, water vapor, and heat between the surface of the earth and the atmosphere.
-
Product
Matrix Vapor Deposition System
iMLayer
-
The iMLayer matrix vapor deposition system is sample pretreatment (application of matrix) in order to perform MALDI-MS imaging using an analysis system such as the iMScope imaging mass microscope or the MALDI-7090. With the iMLayer, the deposition method has been adopted as a pretreatment method to achieve high spatial resolution. By using this method, fine matrix crystal can be produced. Also, thanks to automated control, the coating thickness is reproducibly controlled as users configure.
-
Product
Vapor Sorption Analysis
-
Vapor Sorption Analysis is a technique in which a sample is subjected to varying conditions of humidity and temperature, and the response of the sample is measured gravimetrically. Understanding the effects of water content on structure and properties is critical in the development, processing and end use of a broad spectrum of materials. TA Instruments offers the most sensitive, versatile, and productive moisture sorption analyzers on the market. The Discovery SA combines a high-sensitivity thermobalance, innovative humidity control chamber, and reliable autosampler. Innovative technology combined with our unparalleled reputation for service and support make TA Instruments the clear choice of scientists worldwide for vapor sorption studies.
-
Product
Dynamic Vapor Sorption Analyzer
IGAsorp-XT
-
The IGAsorp-XT is a fully automated water sorption analyzer designed for measurements at temperatures and humidities beyond those available with conventional DVS analyzers. High resolution sorption isotherms are recorded at humidity values from 0.2 %RH or lower, using the unique climate-XT control method. Combined with high temperature water sorption measurements to 300 °C, an integrated pre-heater and completely flexible method programming, the IGAsorp-XT is the world’s most advanced benchtop DVS analyzer.
-
Product
Physical Vapor Deposition Systems
-
Physical Vapor Deposition (PVD) systems use physical processes, like sputtering and evaporation, to deposit thin films with exceptional purity and control. These techniques are widely used in semiconductor manufacturing, optical coatings and protective applications.
-
Product
Dew Point
-
At any temperature there is a maximum amount of water vapor that the air can hold.The dew point is the temperature at which the air must be cooled.Air compression increases the water vapor pressure and thus the dew point.If the air temperature is reduced, the water vapor in the air will begin to condense at a certain temperature. This temperature is called the dew point temperature
-
Product
Gas Analysis
HPR-20 DLS
-
The Hiden HPR-20 DLS gas analysis system is configured for continuous analysis of gases and vapours at pressures near atmosphere in standard form, alternative inlet systems being offered for applications requiring direct sampling from higher pressures to 30 bar.
-
Product
Ultrasonic Metal Welding
-
Ultrasonic metal welding method is used to join dissimilar metals of aluminum wire and copper for aluminum harnesses, thin copper alloys for vapor chambers and hoop materials, and aluminum laminated foil for rechargeable batteries.
-
Product
Selenium Valved Cracker
-
This source has multiple heating zones that can either generate cracked or uncracked selenium flux while resisting the chemical attack from the corrosive vapor. The unrivaled convenience and flux control are maintained without depleting the source material via an all-metal needle valve. Excellent results have been reported producing blue/green LED and laser diode devices.
-
Product
Humidity Meters
-
Easily measure relative humidity (or the percentage of water vapor present in the air or in a gas) and calculate dew point and ice point with ThermoWorks hygrometers, humidity meters and data loggers. Ensure the quality of perishable goods in transportation and storage for food processing and HACCP compliance. Perfect for pharmaceutical applications, computer rooms, construction, horticulture and heating and ventilation (HVAC). Also great for humidors, guitar and violin cases, or gun safes.
-
Product
Quadrupole Mass Spectrometer for Residual Gas Analysis
RGA Series
-
Systems for the examination of components present in a vessel or evolved from a process. HALO RGA – for residual gas analysis. 3F Series RGA – triple filter mass spectrometers for analytical applications. 3F-PIC – pulse ion counting detection for fast event studies. Measures the concentration of gases and vapours in real time.
-
Product
Large Flow Liquid Source Vaporization Control System
LE Series
-
A high-flow, high-efficiency, liquid vaporizer with flow channels and heater elements embedded in a cast aluminium block which ensures maximum heat transfer, and the elimination of both cold spots and the risk of condensation. This Liquid Source Vaporization Control System can operate at up to 300 °C and can vaporize up to 30g/min of IPA (or equivalent).
-
Product
Halogen Moisture Analyzers
-
Halogen Moisture Analyzers determine the initial weight of the sample. The sample is quickly heated by the internal halogen dryer unit causing moisture to vaporize. During the drying operation, the instrument continuously determines the weight of the sample and displays the loss of moisture.
-
Product
ATEX & CID2 Anti-Explosion Certified Robust DIN-rail Fanless Embedded System With Intel® Atom® Processor E3827 (1.75 GHz)/E3845 (1.91 GHz)
rBOX510-6COM (ATEX/C1D2)
-
The rBOX510-6COM(ATEX/C1D2) robust din-rail fanless embedded system is certified with ATEX and C1D2 for use in hazardous environments where ignitable concentrations of flammable gases, vapors or liquids might exist. The embedded system supports the dual-core Intel® Atom™ processor E3827 1.75GHz SoC with the onboard 4GB DDR3L system memory. The din-rail heavy-duty embedded PC adopts an IP30-rated aluminum and steel enclosure, and can perform in wide temperatures ranging from -40°C to +70°C. To prevent ESD and over-voltage, the compact embedded box PC is equipped with four isolated RS-232/422/485 ports, two isolated 10/100/1000Mbps Ethernet ports, and one isolated DIO (8-IN/8-OUT) port. One 2.5" SATA SSD, one mSATA and one CompactFlash™ socket are available for storage. More I/O features include one USB 3.0 port, one USB 2.0 port, two COM ports, and one VGA output. In addition, box PC comes equipped with a wide range 12 - 48VDC power input with a terminal block and has overvoltage and reverse protection. The box PC provides two watchdog timers and RTC battery function. Pre-installed with Linux, Windows® 8 Embedded and Windows® 7 Embedded, the embedded system provides programmers with a friendly environment for developing application software at a lower cost. For secure mounting, the rBOX510-6COM(ATEX/C1D2) can be easily installed on a DIN-rail mount or in an enclosure box.
-
Product
Tunable Diode Laser Absorption Spectroscopy
5100P TDLAS Transportable
-
Using tunable diode laser absorption spectroscopy, the 5100P is a transportable, easy-to-use analyzer optimized to measure either water vapor (H2O) or carbon dioxide (CO2) in select gas streams.
-
Product
Direct Liquid Injection System
VC Series
-
The VC Series is able to rapidly vaporize pure water or other liquid sources without carrier gas, which enables you to construct a more compact vaporization system.
-
Product
Moisture Permeability Tester
DRK501D
-
Shandong Drick Instruments Co., Ltd.
It is used for the determination of water vapor permeability of rigid foam plastics and other materials.
-
Product
Mid-Range Gas Filter Correlation CO2 Analyzer
Model N360M
-
Teledyne Advanced Pollution Instrumentation
The Model N360M measures carbon dioxide (CO2) by comparing infrared energy absorbed by a sample to that absorbed by a reference according to the Beer-Lambert law.The N360M uses Gas Filter Correlation (GFC) to overcome the interfering effects of various other gases (such as water vapor) that also absorb IR. The analyzer passes the IR beam through a spinning wheel made up of two separate chambers: one containing a high concentration of CO2 known as the reference, and the other containing a neutral gas known as the measure. The concentration of CO2 in the sample chamber is computed by taking the ratio of the instantaneous measure and reference values and then compensating the ratio for sample temperature and pressure. A nitrogen purge system is provided for the GFC wheel assembly to eliminate the effects of ambient CO2, if necessary.
-
Product
Gas Adsorption Analyzers
-
These compact, fully automatic analyzers measure high-resolution physisorption, chemisorption, and vapor sorption isotherms for pore size, surface area, and specific gas/solid interactions. All these parameters are essential for the optimization of a wide range of materials, including adsorbents, catalysts, pharmaceuticals, battery materials, and other porous solids.
-
Product
Adsorption Analyzers
-
These compact, fully automatic analyzers measure high-resolution physisorption, chemisorption, and vapor sorption isotherms for pore size, surface area, and specific gas/solid interactions. All these parameters are essential for the optimization of a wide range of materials, including adsorbents, catalysts, pharmaceuticals, battery materials, and other porous solids.