BH Loop
-
Product
Closed Loop Hall AC/DC Current Sensor
CYHCS-D8
-
ChenYang Technologies GmbH & Co. KG
This Hall Effect current sensor is based on closed loop compensating principle and can be used for measurement of DC and AC current, pulse currents etc. The output of the transducer reflects the real wave of the current in the carrying conductor.
-
Product
Digital Closed Loop Control Thermal and Mechanical Testing System
3800 System
-
The Gleeble 3800 is a fully integrated digital closed loop control thermal and mechanical testing system. Easy-to-use Windows based computer software, combined with an array of powerful processors, provides an extremely user-friendly interface to create, run and analyze data from thermal-mechanical tests and physical simulation programs.The result is a system unequaled for physical simulation and thermal-mechanical materials testing.
-
Product
PXI Analog Output/Current Loop Simulator Module - 16 Channel
41-765-001
Analog Output Module
The 41/43-765-001 is a PXI/PXIe 16-channel Analog Output Module designed to meet the requirements of industrial control applications utilizing current loops 4 – 20mA. It consists of up to four 16-bit, digital-to-analogue converters (DAC), capable of creating four current outputs each. Output current within 0mA - 4mA and 20mA - 24mA, give the ability to simulate error or extra signaling conditions. The ±24mA mode gives the ability to simulate either sourcing or sinking sensor.
-
Product
Loop Powered Trip Amplifier With Dual Relay Output
SEM1636
-
The SEM1636 monitors a (4 to 20) mA loop and provides two independent change over trip contacts set to trip at any point within the (4 to 20) mA range.
-
Product
Antenna, Active Loop
EM-6869 | 9 KHz – 50 MHz
-
The Electro-Metrics EM-6869 Active Loop Antenna is used with any receiver or spectrum analyzer with 50 ohm input and covers the frequency range of 9 kHz to 50 MHz.
-
Product
Dynamic Scale Deposition Loop System
-
Dynamic Scale Deposition Loop fully automated systems includes hardware and software to measure and evaluate the performance of scale inhibitors under high pressure and high temperature conditions.
-
Product
Open And Closed Loop Inverters
VFD
-
Inverter products support the energy-saving operation of equipment and machinery with fine speed control.
-
Product
Loop Antennas
-
A.H. Systems' designs, manufactures and delivers high performance Loop Antennas for a wide range of magnetic field testing. Whether used in a set to measure shielding effectiveness per MIL-STD 285 and NSA 65-6 or individually to satisfy specific requirements,
-
Product
PXI Analog Output/Current Loop Simulator Module - 8 Channel
41-765-003
Analog Output Module
The 41/43-765-003 is an 8-channel Analog Output Module designed to meet the requirements of industrial control applications utilizing current loops 4 – 20mA. It consists of up to four 16-bit, digital-to-analogue converters (DAC), capable of creating four current outputs each. Output current within 0mA - 4mA and 20mA - 24mA, give the ability to simulate error or extra signaling conditions. The ±24mA mode gives the ability to simulate either sourcing or sinking sensor.
-
Product
LOCAL LOOP SIMULATOR FOR TR-114 INCLUDING BRIDGED TAP
458-LM-A1-30-TR114
-
The Model 458-LM-A1-30-TR114 Local Loop Simulator for TR-114 is the ideal solution for simulating test loops as defined in TR-114 and includes a Bridged Tap. In addition, it is also suitable for ADSL, ADSL2, ADSL2+, and VDSL2 chip/modem/DSLAM testing of straight loops out to 24,000
-
Product
Short Circuit Loop Impedance Meter
AMZC-305
-
Loop impedance measurement with resolution 0,01Ω ; Loop impedance measurement without tripping the circuit breaker > 30mA with resolution 0,01Ω (100...440V) ; Measurements possible in installations 110/190V, 115/200V, 127/220V, 220/380V, 230/400V, 240/415V, 290/500V and 400/690V (range 100...750V)
-
Product
Recorder for non-stop(Loop)
-
You just set the desired number of the days to keep track of, and Stream MultiRec will record them uninterruptedly 24 hours a day with no human intervention. The number of tracked channels is defined by the user depending on specific requirements and the storage capacity of the video server in use.
-
Product
PXI/PXIe Analog Output/Current Loop Simulator Module - 8 Channel
43-765-003
Analog Output Module
The 41/43-765-003 is an 8-channel Analog Output Module designed to meet the requirements of industrial control applications utilising current loops 4 – 20mA. It consists of up to four 16-bit, digital-to-analogue converters (DAC), capable of creating four current outputs each. Output current within 0mA - 4mA and 20mA - 24mA, give the ability to simulate error or extra signalling conditions. The ±24mA mode gives the ability to simulate either sourcing or sinking sensor.
-
Product
PXI Analog Output / Current Loop Simulators
-
These modules are aimed at simulating industrial control transceivers, utilizing 4–20mA current loops. The modules include built-in relays for shorts and opens functionality enabling fault insertion testing on every channel and also enable slew rates to be programmed so that different sensors can be effectively mimicked.
-
Product
Digital Phase Locked Loop (PLL)
A6-CPS
-
The A6-CPS digital phase locked loop (PLL) can be customised to a specific application and shipped ready for use in production.
-
Product
Loop Meters
-
The CM-1TB + XL-1 are modern digital current loop-powered meters that convert standard loop current to engineering units. They feature high accuracy and a large 0.6-inch LCD display. Proven reliability combined with low cost has earned these meters world-wide acceptance, with thousands in use.
-
Product
High Current Short Circuit Loop Impedance Meter
AMZC-310S
-
Measurement of very small short-circuit loop impedances (with resolution of 0,1mΩ) using the current of 150A under 230V, maximum 280A under 440V, or measurement using the current of 23A under 230V, maximum 42A under 440V
-
Product
Line Loop Tester
8455
-
Simpson?s Model 8455 Line Loop tester detects line shorts, opens and multiple ringers, DC voltages and loop resistance. It can measure DC voltage up to 100 volts and loop resistance to 2 megohms. A front panel ?reverse polarity? switch allows changing polarity positions quicker and easier than manually switching test leads when making line checks.
-
Product
8 Direction Receiving Loops Antenna System
AS-SAL-12/20/30 - Mark II
-
The Array Solutions Shared Apex Loop™ Array (AS-SAL-12 Mark II, AS-SAL-20 Mark II, and AS-SAL-30 – Mark II) is an improved version of the new type of receiving antenna that delivers exceptional directivity in a compact package and is useable over a wide range of frequencies without need for adjustment. This array opens the door to a new class of compact, high performance, wideband receiving antennasdeveloped for both amateur and professional users.
-
Product
Opto-Isolated Current Loop Signal
4029
-
SPECTEC Innovative Sensor Solutions
SPECTEC's Model 4029 digital opto-isolated current loop signal conditioner prevents ground loops and interrupts any galvanic signals riding on magnetic speed sensor's output signal.. This signal conditioner converts magnetic, variable reluctance and inductive sensors' sinusoidal signals into a 4-20 mA output suitable for interfacing with process control units, dataloggers, flow controllers, and computers.
-
Product
Closed Loop Precise Hall AC/DC Current Sensor
CYHCS-LF
-
ChenYang Technologies GmbH & Co. KG
This Hall Effect current sensor is based on closed loop compensating principle and can be used for accurate measurement of DC and AC current, pulse currents etc. The output of the transducer reflects the real wave of the current carrying conductor.
-
Product
MULTI-STANDARD LOCAL LOOP SIMULATOR
458-LM-A8-30
-
Accurately simulates attenuation and impedanceFull bidirectional operation at all specified frequencies26 AWG PIC as specified in ANSI T1.417
-
Product
Loop and Line Powered Level Switch
Safety IntelliPoint
-
The Safety IntelliPoint level switch provides a capacitance probe level switch with either a current output or relay contacts and “On-Board” self-diagnostics to ensure reliability. This SIL Intellipoint conforms to SIL 2 specifications providing the ultimate in level switch integrity and level sensing elements for a wide variety of temperatures, pressures, and materials.
-
Product
Closed Loop Hall AC/DC Current Sensor
CYHCS-SH
-
ChenYang Technologies GmbH & Co. KG
This Hall Effect current sensor is based on closed loop compensating principle and can beused for measurement of DC and AC current, pulse currents etc. The output of thetransducer reflects the real wave of the current carrying conductor.
-
Product
Current Loop Adapter
OP-1C
-
This adapter supports current loop communications.The kit incorporates a communications circuit with photo-coupler isolation and constant-current power supply of insulated type, thus realizing not only monitoring but also easy communications testing with passive or active current loop devices.
-
Product
Short Circuit Loop Impedance Meter
AMZC-304
-
Short circuit loop impedance measurement in networks with nominal voltage: 220/380V, 230/400V, 240/415V, with frequency 45…65Hz ; Short circuit loop impedance measurement with 15mA current, without triggering RCD. ; Detection of the replacement L and N in the socket and automatic swap in the meter
-
Product
Closed Loop Hall Effect Current Sensors/Transducerswith Rectangle Windows
-
ChenYang Technologies GmbH & Co. KG
This Hall Effect current sensor is based on closed loop compensating principle and can be used formeasurement of DC and AC current, pulse currents etc. The output of the transducer reflects thereal wave of the current carrying conductor.
-
Product
Active Loop Antenna
AL-130R
-
Also known as Magnetic Loop Antenna, the AL-130R is compliant with CISPR 16-1-4. It is ideal for emissions measurements as required by various EMC standards such as FCC 18, CISPR 11, CISPR 13, CISPR 14, CISPR 32 and many more. The built-in, low-noise preamplifier, increases overall measurement sensitivity as well as the overall signal to noise ratio. As per ANSI C63.4-2014, the use of active loop antenna for compliance testing is permitted in a non-sheilded environment ONLY if the saturation indicator is continuously monitored during the course of testing. Com-Power’s Remote Antenna Interface (RAI-100) comes in very handy for this application. It is a compact controller which can be used to enable/ disable RF measurement circuit and monitor saturation and battery low conditions remotely via a fiber optic cable up to 30 mtrs in length.
-
Product
Phase Locked Loop with Integrated VCO
-
PLL with integrated VCOs provide local oscillator sources and clock sources for communications (COMMS) , test and measurement (ETM) and aerospace/defense (ADEF) applications. ADI's PLLs with integrated VCO portfolio includes both narrowband and wideband parts, supporting frequencies up to 13.6GHz. Our PLLs with integrated VCO, as well as our full PLL portfolio including integer-N and fractional-N PLLs, feature best-in-class performance for phase noise, jitter, and spurious, and also feature high levels of integration in small form factor packages.
-
Product
Active Loop Antennas / Magnetic Field Probes
-
Is an active, shielded handheld loop antenna with nearly con- stant antenna factor over the entire frequency range. It can be used for testing according to CISPR, MIL, FCC, EN, ISO, ANSI, ETSI and many other standards.