Radiated Emissions
See Also: Emission, Acoustic Emission, Gas Emission, Conducted Emission, Immunity Test
-
Product
Aspirated Radiation Shield
-
The fan has an ingress protection (IP) rating of 55, virtually eliminating moisture and dust ingress. At full speed the power requirement is 1 W (80 mA at 12 V DC). To conserve power fan speed can be reduced, via pulse width modulation (PWM), to 0.3 W at night or when wind speed is greater than 3 m s-1 without loss of accuracy. If the fan is continuously operated at full speed lifetime is rated at 50,000 hours (5.7 years). The fan includes a tachometer, allowing RPM to be mounted to detect obstruction of the fan.
-
Product
Small Device Noise Emission Test System
-
The Small Device Noise Emission Test System from VIacoustics is a turnkey solution for the measurement of noise emissions of small devices typically used in computers, consumer electronics, appliances and automobiles. The system includes all hardware and software necessary (see the components tab) for the determinations of sound power levels (1/3 octave band and A-weighted), emission sound pressure levels (normalized 1/3 OB, A-weighted and high resolution FFT) and *ISO 532B loudness. The system is designed to be operated by a technician for production level testing or to be used by an engineer in the product development process.
-
Product
Radiation Monitoring Systems
-
Monitoring the radiation situation on the territory of radiation-hazardous and radiation-sensitive objects and premises, conducting radiation monitoring of the environment.
-
Product
EMC Emission Measurements
-
AFJ manufactures a complete range of RF emission test equipment for EMC applications.Our FFT EMI Receivers cover the frequency range from 9kHz to 3GHz.
-
Product
Acoustic Emission (AE) Monitoring System
Sensor Highway II System
-
The Sensor Highway II System™ is an Acoustic Emission (AE) monitoring system with up to 16 high-speed channels and 16 standard parametric input channels (expandable to over 100). The system is designed for unattended and remote monitoring use in Structural Health Monitoring management and condition monitoring applications. It is rated for outdoor use and comes equipped in a rugged weather proof NEMA 4 enclosure.
-
Product
Solar Radiation Sensors
-
The solar radiation sensors that Campbell Scientific offers come in a variety of designs: pyranometers, net radiometers, quantum sensors, and pyrheliometers. These sensors measure various aspects of the energy imparted by the sun on the Earth’s surface. A leveling fixture fitted with a bubble level may be required to accurately install solar radiation sensors.
-
Product
SRS-200A Spectral Radiation Safety Test System
-
Hangzhou Everfine Photo-E-Info Co., LTD
SRS-200A is a new generation of portable photo-biological safety test and evaluation equipment. Based on the mainfunctions of the laboratory spectral radiation safety test system, the convenience and operability of test are fully considered.To some extent, the analyzer makes up for on site measurement insufficiency.
-
Product
Emissions Dynamometers
MD-100-CM-2WD
-
High throughput demands of Centralized Emission Inspection require the use of rugged and durable emission inspection equipment. Designed from inception to withstand punishing use and misuse, Mustang Dynamometer has set the performance standards of equipment manufactured and used worldwide for centralized emissions testing. Our pioneering experience has led us to be the world leader in the design and manufacturing of rugged inspection and maintenance hardware and software for the I/M industry. We have centralized testing lanes installed all over the world in climates from cold to hot and from wet to dry. By the end of 2020 we estimate that our equipment will have performed nearly 1 billion vehicle tests. Continuous improvement leads us to innovative solutions based on our knowledge of design, service, maintenance, ergonomics and overall functional capabilities. Mustang I/M Centralized Emission Inspection equipment is designed for our customer’s demands.
-
Product
Sound Level Meter for Automotive – Car Noise Emission Inspection
HD2010MCTC
-
The level of noise produced by vehicles shall comply with standards prescribed by international regulations. During car inspections, horns and exhaust devices must be in good condition and comply with the requirements.
-
Product
EMF Measurements/EM Measurements/Electromagnetic Radiation
-
Holland Shielding Systems B.V.
Electromagnetic fields cause interference in electronic devices and may affect the health of people close to where the fields are generated. It is important to recognize this at an early stage in a construction process, for instance at a future construction location or while construction is already underway, so that budgets are not exceeded. By means of field-strength measurements one can chart the existing electromagnetic fields and radiation emitted by GSM, UMTS antennas and transformer spaces, to mention a few examples. These measurements can help determine the best location in the new building for rooms where sensitive measurements are to take place, e.g. in hospitals or nano laboratories. And last but not least, field-strength measurements can detect sources of interference and can be part of a scheduled check of existing screened spaces and Faraday cages.
-
Product
Chemical Emissions Testing
-
Underwriters Laboratories Inc.
As a global leader in the science of safety, UL evaluates products and materials to determine their impact on indoor air quality and, by extension, human health. Whether your products need to meet the emissions requirements of environmental certifications or regulations or you simply wish to have a better understanding of your products'''' potential impact on the indoor air for legal or risk assessment purposes, UL is your partner for developing healthier, lower emitting products.
-
Product
IR Radiation Systems And Systems
-
Irradiation systems with infrared are used in test applications when a high heat input to the test object is required. In our portfolio you will find a wide range of different designs and areas of application for IR systems. From simple radiation modules to highly complex radiation systems.
-
Product
Gamma Radiation Detector
PocketGeiger
-
Yaguchi Denshi Kogyo Co., Ltd.
Pocket Geiger is a smartphone-connected radiation detector. We have three product types on PocketGeiger series to support various devices you have.; iOS, USB and Embedded ( for ARDUINO, PIC, Edison).
-
Product
Radiation Meters
-
A radiation meters is a device designed for measuring varying types of radiation. These devices are portable and are used to inspect personnel, equipment, and facilities for radioactive contamination by measuring the emission of certain radiation particles. They are used to measure external or ambient ionizing radiation field to assess the direct exposure hazard.
-
Product
Particle Counter Emissions Tester
PARTICLE COUNTER | VP 135046
-
Maschinenbau Haldenwang GmbH & Co. KG.
With the PARTICLE COUNTER emission tester, you can really count every particle. Compact, rugged design, clearly readable display, rapid readiness for measurement and precise measurement results are the distinguishing features of the MAHA particle counter.
-
Product
PCE-2000UV_1.5 Ultraviolet Light Radiation Measurement System
-
Hangzhou Everfine Photo-E-Info Co., LTD
PCE-2000UV UV light source radiation Measurement system can realize the measurement of the relative spectral power distribution of ultraviolet LED, UV fluorescent lamp, UV light source, peak wavelength, half-peak wavelength, spectral radiation flux of UV-A/B/C, and the total radiation flux in specific wavelength.
-
Product
Combination Emissions Tester on CONNECT Trolley for Measurement of Petrol- and Diesel-Powered Vehicles
MCT CT | VP 135226
-
Maschinenbau Haldenwang GmbH & Co. KG.
The combination tester on CONNECT trolley is designed for the measurement of petrol- and diesel-powered vehicles. In addition, low weight, compact design and short warm-up time ensure easy handling.
-
Product
Radiation Microdosimeters
-
Teledyne e2v HiRel Microdosimeter is a compact hybrid microcircuit which directly measures total ionizing dose (TID) absorbed by an internal silicon test mass. The test mass simulates silicon die of integrated circuits on-board a host spacecraft in critical mission payloads and subsystems. By accurately measuring the energy absorbed from electrons, protons, and gamma rays, an estimate of the dose absorbed by other electronic devices on the same vehicle can be made. The Microdosimeter can operate from a wide range of input voltages. The accumulated dose is presented to three dc linear outputs and one pseudo-logarithmic output giving a dose resolution of 14 µrads and a measurement range up to 40 krads. These outputs are intended to be directly connected to most analog-to-digital converters (ADCs) or spacecraft housekeeping analog inputs (0-5 V range), which makes minimal demands on the host vehicle. The Microdosimeter incorporates a test function to allow electrical testing of the hybrid without the need for a radiation source.
-
Product
Low-PIM, High-Power Filter Solutions for Monitoring Broadband Emissions
-
Enables monitoring of PIM to 13 GHz; 100W CW and 1KW peakNear-end monitoring: Carriers rejected -90dB by the notchtravel through the bandpass filter to the low PIM termination.Far-end monitoring: Carriers rejected -90dB by the highpass,IM products passed are monitored by the spectrum analyzer.
-
Product
Osram Direct Emission Green Laser Diodes (510 - 530nm)
-
The Optoelectronics Company Ltd
The PLT3 520D laser diode can deliver 140mW pulses at 520nm with 8% efficiency, driven at 300mA at 50% duty cycle – OSRAM's previous limit was 80mW with the PL 520B. This new diode has been developed to work in MEMS-based scanners.
-
Product
Radiation Survey Device
DRG-T
-
The DRG-T radiation survey device is designed for use in special-purpose vehicles for continuous control and measurement of exposure dose rate (EDR) of gamma and X-ray radiation, as well as for providing audio and visual alarm of its dangerous levels and for issuing commands to start the actuators of protection equipment.
-
Product
Electromagnetic Radiation Tester
KM 196
-
Kusam Electrical Industries Limited
Unit : Electric Field : V/m; Magnetic Field : mT. Precision : Electric Field : 1V/m; Magnetic Field : 0.01 mT. Range : Electric Field : 1V/m ~ 1999V/m. Magnetic Field : 0.01 mT ~ 19.99 mT. Alarm Threshold : Electric Field : 40V/m, Magnetic Field : 0.4 mT. Reading Display : 3½ Digit Digital LCD display with Backlight. Frequency Range : 5Hz ~ 3500MHZ. Sampling Time : About 0.4 second. Measuring Mode : Dual Mode. Overload Alert : “1” appears on LCD. Sound & Light Alarm. Data Hold function. Auto Power Off. Average & Peak measurement. Low Battery Indication. Operating Temperature & Humidity : 0°C ~ 50°C; below 80%RH. Power battery : 9V Battery. Dimension : 63.6 x 31 x 125.8mm. Weight : Approx. 146g.
-
Product
Proton Induced X-ray Emission (PIXE)
-
Elemental Analysis Incorporated, utilizing Proton Induced X-ray Emission (PIXE), provides a non-destructive, simultaneous analysis for the 72 inorganic elements from Sodium through Uranium on the Periodic Table for solid, liquid, and thin film (i.e. aerosol filter) samples. The PIXE technique offers the advantage of analysis, without the necessity for time consuming digestion, thereby minimizing the potential for error resulting from sample preparation.
-
Product
Radius Radiation Probe
Hawk Radius®
-
The Hawk® Radius is a ruggedized solution for monitoring both ambient and elevated levels of ionizing radiation. Like a Hawk with its remarkable vision, the Hawk Radius Probe “sees” things that other probes cannot. The high sensitivity weatherized pancake sensor can provide early warning of changing ambient radiation conditions, while the energy compensated detector can accurately report penetrating gamma radiation dose rate at elevated levels. Radius probes are typically deployed as part of an environmental radiation monitoring program, or for safety and security systems. In its standard configuration the probe detects beta, low energy gamma and x-radiation with one channel and energy compensated penetrating gamma radiation levels with a second channel. It can be configured to detect alpha radiation as well. The Hawk® Radius has been deployed worldwide in demanding conditions for protecting communities and collecting environmental radiation data. It can be deployed easily and requires minimum maintenance. The Radius is compatible with Medcomʻs GeigerLink adapter and the IMI Gateway App for use with personal computers. It can also be used with most data loggers including popular Campbell Scientific models.
-
Product
Personal Gamma Radiation Dosimeter
DKG-21M
-
Measurement of individual equivalent dose rate (EDR) of gamma radiation.Measurement of individual equivalent dose (ED) of gamma radiation.Clock, alarm clock.
-
Product
Optical Emission Spectrometers
-
Optical emission spectrometers (OES) and the measuring principle of the atomic emission are the ideal method and provide the perfect instrumentation for metal analysis in all different industrial businesses and environments.
-
Product
600MHz To 4GHz Radiation Measurement System
RMS-0640
-
The MegiQ Radiation Measurement System (RMS) is a compact test system that performs 3-axis radiation pattern measurement in non-anechoic spaces.
-
Product
Solar Radiation Meter
MacSolar E
-
The measuring device has been designed primarily for engineers, architects, fitters and measurement technicians. The MacSolar E allows both an indication of the current irradiance as well as an estimate of the solar installation yield.
-
Product
CDNE For Emission Measurement On Luminaries
-
CDNs have been used as coupling-/decoupling networks to measureconducted noise as well as for immunity testing so far.
-
Product
Sample Pretreatment For Optical Emission Spectrometry
-
Samples are taken from molten metal, thin sheet, semi-complete or complete products. When sampling molten metal with a ladle, small quantities of molten metal are poured into a casting mold. Unnecessary parts of the sample are removed using a grinder or a cutter. As particles from a grinder may contaminate the surface of the sample, a lathe or milling machine is used (not a grinder) to cut soft samples such as white metal. If trace elements are not being investigated, a grinder or belt sander can be used. However, to minimize contamination, the grinding wheel or belt should be changed for each sample. Samples excised from semi-complete or complete products must be at least 12 mm in diameter. Small rod-shaped samples can be analyzed using special equipment.