-
Product
LXI 50Ω Microwave Transfer Switch
60-808-315-015
Microwave Transfer Switch
These LXI (Ethernet-controlled) Microwave Transfer Switches are suitable for routing 50 Ω signals up to 50 GHz. With up to 16 switch banks, they are ideal for constructing complex microwave switching systems for many applications. Connection is by front panel mounted SMA. SMA 2.9 or SMA 2.4 connectors.
-
Product
PNA-L Microwave Network Analyzer
N5235B
Network Analyzer
Perform basic analysis of passive components and simple active devices Measure S-parameters with good accuracy up to50 GHz in cost-sensitive applications Get the world's best price-to-performance ratio for microwave manufacturing Configure an economical solution for signal-integrity measurements and materials characterization Accelerate insight into component behavior using a multi-touch display and intuitive user interface Every spec verified, adjustments included Lock in support & peak performance from the start
-
Product
18 GHz Differential TDR/TDT Probe Kit
N1021B
-
Connect PCBs and other devices without connectors to TDR/TDT modules in the oscilloscope mainframe
-
Product
Double Ridged Waveguide Horn
DRH110
-
Frequency Range 14 GHz - 110 GHz VSWR (AVG) <2.1 1:1Impedance 50 WConnector 1.00mm female Power (CW / Peak): 4 W / 8 W
-
Product
PXE EMI Test Receiver, 1 Hz to 44 GHz
N9048B
Receiver
Keysight's N9048B PXE is a standards-compliant EMI test receiver equipped with an RF pre-selector and LNA designs. Shorten your overall test time and easily perform gapless signal capture and analysis with real-time scan (RTS) capabilities.
-
Product
Active Hot Parameters For M98xxA PXIe VNA
S95111B
-
S95111B active hot parameters are available on M98xxA PXIe vector network analyzers and provide a more accurate method to test hot S-parameters, gain, and output power than traditional methods by utilizing X-parameter technologies. Restricted to 50 GHz.
-
Product
cRIO-9043, 1.30 GHz Dual-Core CPU, 2 GB DRAM, 8 GB Storage, -40 °C to 70 °C, Kintex-7 160T FPGA, 4-Slot CompactRIO Controller
785620-02
Embedded Controller
1.30 GHz Dual-Core CPU, 2 GB DRAM, 8 GB Storage, -40 °C to 70 °C, Kintex-7 160T FPGA, 4-Slot CompactRIO Controller - The cRIO-9043 is a rugged, high-performance, customizable embedded controller that offers Intel Atom dual-core processing, NI-DAQmx support, and an SD card slot for data-logging, embedded monitoring, and control. It includes a Kintex-7 160T FPGA with LabVIEW FPGA Module support for advanced control and coprocessing. The controller provides precise, synchronized timing and deterministic communications using Time Sensitive Networking (TSN), which is ideal for highly distributed measurements. This controller offers several connectivity ports, including Gigabit Ethernet, USB 3.1, USB 2.0, RS232, and RS485 ports. You can use the USB 3.1 ports to add a local human machine interface and program, deploy, and debug software, which simplifies application development.
-
Product
4-in-1 OSLT Calibration Kit, DC to 26.5 GHz, Type-3.5 mm (f) 50 Ohm
CK521A
-
The Network Analyzer Calibration Kits with open, short, load, and thru (OSLT) provide the RF components needed to enable stable and accurate error correct measurements. Calibration of a network analyzer using Spanawave's Network Analyzer Calibration Kits allow for precise measurements. The Calibration Kits offer broad test equipment coverage for use with the 8003 Scalar Network Analyzer as well as being compatible with most network analyzers produced by other manufacturers. Spanawave calibration kits yield complete calibrations, as it takes into consideration the three major sources of systematic error correction by one port calibration at both ports.
-
Product
WiFi / WiMAX RF Power Divider Combiners
-
INSTOCK Wireless Components, Inc
INSTOCK Wireless 2.4-6.0 GHz Power Divider, Power Combiners offer best-in-class performance for WiFi, WiMAX, 802.11b/g/n, and ISM signal splitting applications. IP67 outdoor weatherproof construction provides protection from the elements for uninterrupted outdoor use. All models available in 2-way thru 48-way configurations with Type N, SMA, TNC, BNC, and QMA connector configurations INSTOCK.
-
Product
WR-12 Waveguide Straight
WAG-12-SXX
-
• 60 GHz to 90 GHz• Low Insertion Loss, typical for length• Low Return Loss, typical for length• UG-387 flangeView more WR-12 Waveguide Straight
-
Product
PXI/PXIe Microwave Multiplexer, Dual SP8T, 26.5 GHz, 50 Ω, SMA, Terminated, Remote Mount, Failsafe
42-788-042-TE
Multiplexer Module
The 40-788-042-TE (PXI) and 42-788-042-TE (PXIe) are dual failsafe SP8T 26.5 GHz microwave multiplexers with automatic termination of unused signals and remotely mounted relays. The 40/42-788 range of multiplexers are also available as single or dual, SP8T, SP10T or SP12T panel mounted multiplexers with relays mounted on the front panel.
-
Product
Cable Assembly, Type-N (m) to Type-N (m), DC to 18 GHz
11500D
Cable Assembly
The Keysight 11500D is a 152 cm (60 in) type-N male to type-N male cable assembly with a frequency range of dc to 18 GHz.
-
Product
RF Matrix Switch for Wireless Technologies up to 4 GHz
NEXUS-4
-
Quintech Electronics and Communications Inc.
The NEXUS-4 is a bi-directional fully non-blocking 3232 RF matrix switching system that can route any input ports to any outputs in a 6 RU chassis. With the frequency range of 700 MHz to 4 GHz and the capability of expanding to 256256, it enables large scale wireless testing that involves many MIMO base stations and devices. The built-in programmable attenuators and efficient automation interface provide ease-of-use testing of signal fade and emulation of mobility scenarios. It can dramatically increase lab efficiency by eliminating manual patch panel and cabling as it can be remotely reconfigured for different test setups consistently in seconds.
-
Product
Near Field Microprobe E-field 7 MHz to 3 GHz
ICR E150
-
The near field microprobe is used to measure electric fields at extremely high resolution and sensitivity. The optimal distance to the object being measured is < 1 mm. Due to its small probe head dimension, the probe has to be moved by a manual or automatic positioning system, e.g. Langer-Scanner.
-
Product
PXI/PXIe Microwave Multiplexer, Single SP8T, 40 GHz, 50 Ω, SMA 2.9, Terminated, Remote Mount
40-788-051-TE
Multiplexer Module
The 40-788-051-TE (PXI) and 42-788-051-TE (PXIe) are single SP8T 40 GHz microwave multiplexers with automatic termination of unused signals and remotely mounted relays.
-
Product
Coaxial Switch, DC Up To 26.5 GHz, SPDT
N1810UL
-
The Keysight N1810UL latching coaxial switch combines unmatched flexibility of configuration with excellent repeatability, long life, and reliability.
-
Product
WaveMaster Oscilloscope, 4 GHz Bandwidth, 4 Input Channels, 40 GS/s Max Sample Rate
WaveMaster 804Zi-B
Oscilloscope
Up to 20 GHz bandwidth and 80 GS/s sample rate.The most advanced oscilloscope user interface.The industry’s only true hardware 14.1 Gb/s serial trigger.Low Jitter Measurement Floor and exceptional timebase stability.Comprehensive set of serial data analysis, debug, validation and compliance tools.Integrated 50 Ω and 1 MΩ inputs for true connection and probing flexibility.Integrated standard and custom measurements and math functions for unrivaled analysis capability.Multi-lane serial data eye, jitter and crosstalk analysis.Real-time de-embedding, emulation, and equalization.
-
Product
Test Port Adapter Set, 2.4 Mm To 2.4 Mm
85130G
-
The Keysight 85130G test port adapter protects the test set port from connecting directly with the device under test. It has a special rugged female connector that connects to the network analyzer test port. This special connector does not mate with a standard male connector but converts the rugged test set port to a connection that will mate with the device under test. This set contains a NMD-2.4 mm (f) to NMD-2.4 mm (m) adapter and a NMD-2.4 mm (f) to PSC-2.4 mm (f) adapter. The frequency range for these adapters is dc to 50 GHz with a return loss of 23 dB or better.
-
Product
PXI/PXIe Microwave Multiplexer, Single SP8T, 18 GHz, 50 Ω, SMA, Failsafe
42-788-021
Multiplexer Module
The 40-788-021 (PXI) and 42-788-021 (PXIe) are single failsafe SP8T 18 GHz unterminated microwave multiplexers. The 40/42-788 range of multiplexers are available as single or dual, SP8T, SP10T or SP12T configurations with relays mounted on the front panel. Remote versions are also available which can support one or two multiplexers in a dual slot module.
-
Product
Differential Active Probe, 1.7 GHz
DP0013A
Signal Probe
The Keysight DP0013A is the 1.7 GHz model of the DP001xA Series differential active probes. These provide the superior general-purpose differential signal measurements required for many of today’s high-speed power-related measurements such as motor drives, automotive differential bus measurements, and high-speed digital system designs.
-
Product
Oscilloscope, 65 GHz Bandwidth, 4 Input Channels, 160 GS/s Max Sample Rate
LabMaster 10 Zi-A 65 GHz Systems
Oscilloscope
65 GHz, 160 GS/s, 64 Mpts/Ch Digital Bandwidth Interleaved Acquisition Module, 50 Ohm Input. Also operates in 36 GHz, 80 GS/s, 4ch, 32 Mpts/Ch mode.
-
Product
4 Way GPS / GNSS Signal Splitter Passive, 1-2 GHz, N Type, DC Block+200Ω Load 4 Ports
GPS402
-
INSTOCK Wireless Components, Inc
GPS L1 - L5, GLONASS, Galileo splitterLow Insertion Loss (0.4 dB avg)High Port to Port Isolation (30 dB avg)Excellent VSWR (1.10 : 1 avg)15 VDC & 75 mA max on DC block portsTri Alloy N Type Female (Jack) 50 Ohm
-
Product
10 MHz to 6 GHz/33 GHz LAN Power Sensor
U2049XA
Power Sensor
Wide dynamic range (-70 to +20 dBm) for small signal measurements LAN/ Power-Over-Ethernet (PoE) connectivity for long distance remote monitoring (up to 100 meter)TVAC compliant for operation in vacuum Best-in-class long term drift performance Internal zero and automatic calibration saves time and reduces measurement uncertainty Easy measurement start-up with new intuitive BenchVue software
-
Product
Manual Step Attenuator, DC to 18 GHz, 0 to 11 dB, 1 dB steps
8494B
Attenuator
The Keysight 8494B dc to 18 GHz manual step attenuator offers exceptional repeatability and reliability. Attenuation is provided in 1 dB steps from 0 to 11 dB. Precision gold-plated leaf springs ensure long life (over 5 million cycles) and very high attenuator repeatability (typically 0.01 dB). To improve measurement accuracy, NIST traceable data (SWR and attenuation) is available as Option UK6. Custom step attenuator/switch combinations are possible. The Keysight 11716A/B/C interconnect kits provide quick connection of Keysight 8494/5/6/7 1 dB and 10 dB step attenuators in series for greater dynamic range with 1 dB steps.
-
Product
Multiport Coaxial Switch, DC to 4 GHz, SP6T
87106A
-
The Keysight 87106A multiport switch improves insertion loss repeatability and isolation, which is necessary for higher performance test systems. The repeatability and reliability of this switch is vital to ATS measurement accuracy and can cut the cost of ownership by reducing calibration cycles and increasing test system up time. The Keysight 87106A terminated multiport switch provides the long life and reliability required for automated test and measurement, signal monitoring, and routing applications. Highly repeatable switching capability is made possible through Keysight's rigorous design and tight manufacturing specifications. Low insertion loss repeatability reduces sources of random errors in the measurement path, which improves measurement accuracy.
-
Product
Impedance Matching Pads
-
Impedance matching pads from BroadWave eliminate impedance discontinuity (mismatches) without introducing reflection to the circuit. Custom units are available in a variety of impedance and connector types from DC to 4 GHz. BroadWave Technologies impedance matching pads preserve signal integrity by matching virtually any transmission line.
-
Product
PXI/PXIe Microwave Multiplexer, Single SP10T, 18 GHz, 50 Ω, SMA, Remote Mount, Failsafe
Multiplexer Module
The 40-788-121-E (PXI) and 42-788-121-E (PXIe) are single failsafe SP10T 18 GHz unterminated microwave multiplexers with remotely mounted relays. The 40/42-788 range of multiplexers are also available as single or dual, SP8T, SP10T or SP12T panel mounted multiplexers with relays mounted on the front panel.
-
Product
PXI/PXIe Microwave Multiplexer, Dual SP10T, 18 GHz, 50 Ω, SMA, Terminated, Remote Mount, Failsafe
40-788-122-TE
Multiplexer Module
The 40-788-122-TE (PXI) and 42-788-122-TE (PXIe) are dual failsafe SP10T 18 GHz microwave multiplexers with automatic termination of unused signals and remotely mounted relays. The 40/42-788 range of multiplexers are also available as single or dual, SP8T, SP10T or SP12T panel mounted multiplexers with relays mounted on the front panel.
-
Product
PXI RF Multiplexer: 3 GHz, 1 x 8, 50 Ω
M9148A
Multiplexer Module
Route signals up to 3 GHz through a 1 x 8 RF switch multiplexer in a single PXI module.
-
Product
LXI 50Ω Microwave Transfer Switch
60-808-410-001
Microwave Transfer Switch
These LXI (Ethernet-controlled) Microwave Transfer Switches are suitable for routing 50 Ω signals up to 50 GHz. With up to 16 switch banks, they are ideal for constructing complex microwave switching systems for many applications. Connection is by front panel mounted SMA. SMA 2.9 or SMA 2.4 connectors.





























