Static Analyses
-
Product
Static Pressure Meters
-
Portable dual port manometer accessory head for use with our modular multimeters (DMMs) and instruments. Measures gas pressure, static pressure and pressure differential. The ADMN2 includes a zero adjust and the Auto Power-Off (APO) function to conserve battery life. Disable APO for data logging. The ADMN2 measures pressure between -60inWC and 60inWC (inches of water column) and -150.0 to 150.0 mBar. The ADMN2 also measures P1 or P2 pressure readings and calculates the difference between P1 and P2. Take static pressure measurements using the resolution mode of 0.01inWC or 0.01mBar.
-
Product
FM/ATEX Approved Static Discharge Cable Reels
Cen-Stat Static Discharge Reels
-
Retracting cable reels are an alternative solution to using retractable Cen-StatTM spiral cable. They are normally specified for locations where there is a preference for ensuring process operators stow grounding clamps correctly for good "housekeeping" purposes when the clamps are not in use.
-
Product
Battery Electrical System Analyser
-
We invented the “Resistance method” which uses a series of shorting pulse to measure the voltage drop in order to calculate the plate’s internal resistance. Unlike other patented “Conductance method” which generates an AC pulse across the battery terminal to measure impedance.
-
Product
Digital Static Field Meter
Model 715B
-
- Assess electrostatic fields or charge on objects- Measures up to ±19.99 kV at a distance of 1 inch- Accuracy of <±5% in both normal and ionized environments- Uses a chopper stabilized sensor- LED ranging lights for positioning the meter at the right distance- Zero function allows the display to be adjusted to zero (0)- Hold feature to lock the reading on the display- Low battery indicator on the display- 1-year limited warranty
-
Product
Locomotive Circuit Breaker Analyser
CBScan Locomotive Circuit Breaker
-
CBScan Locomotive Circuit Breaker Analyser is a compact and portable analyser used for testing 25 kV medium voltage circuit breakers that are used in electric locomotives for protection from the frequently occurring short-circuits in the overhead catenary system. The analyser is ideal for railway yards for performing periodic maintenance checks.
-
Product
MDS Audio Oscilloscope / Spectrum Analyser
-
Sampling frequency: 8 000 - 192 000 HzVertical resolution: 16 bitSound card selection: YESChannels count: 2Channels modes: independent, I master - II slave, II master - I slaveMath: Ch1=Ch1+Ch2; Ch1=Ch1-Ch2; Ch2=Ch2+Ch1; Ch2=Ch2-Ch1Signal reconstruction: YESPretrigger: YESTrigger events: above, below, free runInternal trigger: YESExternal trigger: two channel mode - NO, single channel mode - YESData visualisation modes: single, continuous displayFFT points count: 8 - 2 097 152FFT Window functions: Rectangular, Gauss, Hamming, Hann, Bartlett, Triangular, Bartlett-Hann, Blackman, Nutall, Blackman-Harris, Blackman-Nutall, Flat TopOscilloscope amplitude axis units of measurement: Volts (nV...kV), Sample Value (smp)
-
Product
Wire/Cable Harness Analyser
-
Qmax Test Technologies Pvt. Ltd.
Wire/Cable Harness Analyser by QMax
-
Product
Pitot / Static Tester for Laboratories and Workshops
ADSE 741
-
The ADSE 741 is a complete high performance three channel Ps, Pt and AoA stand-alone test bench specially designed to be used in the workshop or in the laboratory to test and calibrate all air data equipment such as altimeters, vertical speed indicators, air speed indicators, pneumatic AoA (Angle of Attack) indicators, MACH-meter, air data computers, specific probes and sensors.The high precision embedded sensors enable the ADSE 741 to be used as a pressure standard.The user interface is programmed underWindows and Labview, with a data base managed in a spreadsheet for easy evaluation, management, statistics and presentation.
-
Product
Automated Total Nitrosamine Analyser
-
Ellutia Chromatography Solutions
Nitrosamines are carcinogenic compounds that can be found and formed in many products. This has been a particular issue in the pharmaceutical industry recently. Traditional approaches to the analysis, such as by mass spec, have been challenging due to the low detection levels required, the possibility of false positives, or even missing. This system takes a unique approach of using the combination of a chemical reaction targeting nitrosamine compounds, then detection by a detector with very high selectivity and sensitivity for nitro/nitroso compounds. Rather than speciating the various nitrosamines present, the system gives a single quantitative result down to 1 ppb for the total nitrosamine content. This means both volatile and non-volatile nitrosamines are measured at the same time. This process is automated to allow a high sample throughput. This makes it ideal for screening a large number of samples rapidly.
-
Product
Pitot Static Tester
ADSE 650
-
The ADSE 650 caters fully for all aircraft types and the different electrical power supplies.It can be used for testing high performance civil and military aircraft, fix and rotary wings. This Pitot Static Tester is designed primarily for flightline use to cover the testing of all barometric and manometric pressure instrument systems.The large touch screen display, with on-screen help ,enables all checks to be carried out easily on the flight deck or in the cockpit, by a single operator.
-
Product
Static Load Cells (5 N to 300 kN)
2530 Series
-
The Instron 2530 Series static load cells are precision force transducers engineered for versatile use in tension, compression, cyclic, and reverse stress testing, delivering accurate measurements down to 1/500th of their capacity. Individually temperature-compensated and calibrated, they support automatic recognition and electronic calibration, and are built to international force-measurement standards (ASTM E4, ISO 7500-1 class 0.5, and JIS B7721, B7733). With overload protection (150 % of rating without damage, 300 % without mechanical failure), the 2530 family offers consistent, repeatable performance across a wide force range (5 N to 300 kN).2530 Series load cells with capacities of 5 N to 100 N are for use with 3300, 3400, 5900, and 6800 Series testing systems.2530 Series Load cells with capacities of 500 N to 300 kN are for use with 3300 and 3400 Series testing systems.
-
Product
Surface Resistance Meter Kit - Test Anti-Static, Static Dissipative and Conductive Surfaces
PRS-812RM
-
- Surface Resistance Tester from 0.10 Ω to 1 Teraohm- Constant Voltages 10 volts and 100 volts- Automatic Electrification Period- Determines if a surface is Dissipative, Conductive, or Insulative- Measures resistance point-to-point(Rtt) and resistance to ground (Rtg)- Measures resistance of ESD Flooring, ESD Worksurfaces and Packaging- Conforms to all ESD Association Standards for Resistive Characterization- Includes 2 each Surface Resistance Probes- Packaged in a hard shell Carrying Case- Certificate of Calibration Traceable to NIST included- 2-year Limited Warranty on Main Instrument
-
Product
Anti Static Nozzles
-
is a high-performance ionization source, designed to simultaneously neutralize static charges and remove electrostatically bonded particulate from surfaces.
-
Product
Static Charge Event Detector / Data Logging System
EV-10A
-
Tokyo Electronics Trading Co., Ltd.
EV-10A detects ESD (Electro-Static Discharge) and records them in a PC. ESD sensitive electronic components increase rapidly. If electro-static charge is not strictly controlled in the production line of these components or in the assemble line using them, the yield will be decreased.
-
Product
Static Multiple Light Scattering (SMLS)
TURBISCAN
-
Static Multiple Light Scattering (SMLS) is an optical method that allows for the direct characterization of native concentrated liquid dispersions. Microtrac’s TURBISCAN range uses this technology to provide accurate and rapid results. TURBISCAN was the first patented technology to provide tools that allow accelerated aging tests on unstressed products, thus becoming a reference for direct stability characterization technology.














