Total Organic Carbon
measure of carbon found in an organic compound.
-
Product
Gas Filter Correlation Carbon Dioxide Analyzer
Model T360
-
The Model T360 CO2 analyzer measures Carbon Dioxide by comparing infrared energy absorbed by a sample to that absorbed by a reference gas according to the Beer-Lambert law. Using a Gas Filter Correlation Wheel, a high-energy IR light source is alternately passed through a CO2 filled chamber and a chamber with no CO2 present. The light path then travels through the sample cell, which has a folded path of 2.56 meters.The energy loss through the sample cell is compared with the reference signal provided by the filter wheel to produce a signal proportional to concentration, with little effect from interfering gases within the sample. This design produces excellent zero and span stability and high signal to noise ratio, allowing excellent performance over a wide concentration range.All T Series instruments offer an advanced color display, capacitive touch screen, intuitive user interface, flexible I/O, and built-in data acquisition capability. All instrument set up, control and access to stored data and diagnostic information is available through the front panel, or via RS232, Ethernet, or USB com ports, either locally or by remote connection.The Model T360 comes with NumaView™ Software. NumaView™ Remote PC Software allows for a remote connection with virtual interface and data downloading capability to analyzers operating NumaView™ Software.
-
Product
Analyzer for Total Sulfur in Gas Application
SGA-1000
-
The ATOM SGA-1000 is an online process analyzer utilizing patented Excimer UV Fluorescence (EUVF) Technology to measure Total Sulfur in a variety of refinery process applications.ATOM Instrument offers the most versatile total sulfur analyzers available. The ATOM SGA-1000 has the fastest analysis time of any commercially available analyzer allowing user-defined, multiple cycle averaging to improve analyzer performance. The analyzer operating software is both intuitive and user-friendly. In addition, the ATOM SGA -1000 only requires bottled air for normal operation and does not require installation in a shelter.
-
Product
Total Nitrogen and Sulfur Analyzer
XPLORER-NS
-
The XPLORER-NS was developed as a total nitrogen/total sulfur combustion analyzer, capable of handling fully automated applications for liquids, solids, and gases (including LPG samples.) Changing from the liquids & gas module to the solids module has never been easier. Just push one button and the liquids module is automatically retracted from the heated zone. No clamps or manual locks required.
-
Product
Digital Total Chlorine Tester
MW11
-
The Milwaukee MW11 Total Chlorine Photometer lets you go digital with your testing. No more hit and miss testing with strips. Great for aquariums, aquaculture & coral, labs, water conditioning , classroom and more. This meter is also ideal for educators that want their students to learn the basics of water quality analysis to apply in the real world.
-
Product
Carbon / Sulfur Elemental Analyzer
EMIA-Expert
-
The EMIA-Expert Carbon/Sulfur Analyzer is based on HORIBA''s widely respected expertise in Non-Dispersive Infrared (NDIR) technology. It offers improved the cleaning efficiency, enhanced user-friendly software, durability, operability and maintenance to ensure efficient measurements and its shortened cycle time accelerates your development and manufacturing speed.
-
Product
Total Hydrocarbon in Water Analyzer
Model 4080
-
Teledyne Analytical Instruments
The Model 4080 is designed to detect hydrocarbons (C1-C9+) which may not absorb in the UV region)
-
Product
Carbon Monoxide Detector, CO
ENVIROMUX-CMD
-
Continuous air monitoring. Pre-set alarm points alert at: 70 ppm after 60 to 240 minutes; 150 ppm after 10 to 50 minutes; and 400 ppm after 4 to 15 minutes. Flush or surface mount. Test functionality of electrochemical CO sensing cell. Connect to RJ45 or digital input sensor ports. Screw terminal. To connect to the RJ45 inputs use CAT5/5e/6 cable terminated at one end with RJ45 connector. Connect the un-terminated end to the sensor screw terminal. Maximum cable length: 1000 ft (305m). LED indicators for operation status and system test. Powered by ENVIROMUX-2D/5D/16D. Regulatory approvals: UL.
-
Product
0-600 Amp Variable Carbon Pile Load Tester
6039
-
• Test batteries up to 1200 CCA• Fine threaded shaft for fine adjustment• Temperature compensation chart• Easy to read digital voltmeter & ammeter combine with the versatility of a carbon pile load• Spring loaded to shut-off automatically• Unique curved discs to prevent hot spots• Tests all battery types• Made in USA of US and Global Components
-
Product
Carbon Fibre Beam Gauge
-
Designed to measure both internal and external diameters and lengths, the high modulus carbon fibre beam is stiff, lightweight and has an extremely low co-efficient of thermal expansion (CTE). Suitable for measuring high accuracy diameters and lengths up to 4000mm+.
-
Product
Process Meter & Totalizer
-
User-scalable for display to 999,999 for 0-1 mA, 4-20 mA, or 0-10 V process signals requiring zero and span adjustment. Ideal as flow rate meter or flow totalizer for analog flow meter signals. Includes 5, 10, 24 V transducer excitation output (user-selectable).
-
Product
Carbon and Sulfur in Inorganic Materials by the Combustion Infrared Detection Technique
844 Series
-
LECO combined our customers' feedback with innovative engineering to develop the CS844, an elemental analyzer designed for wide-range measurement of carbon and sulfur content of primary steels, ores, finished metals, ceramics, and other inorganic materials using the combustion technique. Our exclusive MS Windows®-based software, coupled with a boom-mounted touch interface, gives you complete access to instrument control, analysis settings, diagnostics, reporting, and more—without sacrificing valuable bench space.
-
Product
Diamond-Like Carbon: High-Performance Coatings for Extreme Applications
-
When durability matters, Diamond-Like Carbon (DLC) coatings deliver. Known for their hardness, low friction, and chemical resistance, DLC films are the go-to solution for protecting surfaces in high-stress environments: from precision mechanical parts to advanced semiconductor devices.
-
Product
Carbon Dioxide Quality Control System
CDQC
-
Teledyne Analytical Instruments
Teledyne’s Carbon Dioxide Quality Control (CDQC) system offers an integrated package to continuously monitor impurities in carbon dioxide (CO2). The plug-and-play design allows for the user to select only the gases and features of interest to maximize cost benefit and space.Front door viewing windows allow for view of all analyzer displays, flow and pressure settings. Stainless steel tube fitting connections and NPT or metric electrical ports as required are conveniently located in a central location for ease of access. Sample conditioning, utility gas provisions and integral calibration gas solenoid valves are standard.
-
Product
Transmitter Monitors Carbon Monoxide
CO-R
-
The CO transmitter monitors carbon monoxide (CO) levels and is designed for the continuous monitoring of vehicle exhaust in non-hazardous areas. The CO uses a wide spectrum, long life electrochemical sensor to measure the amount of carbon monoxide in the environment. It is offered with an operating range of 0 to 125 ppm. Both the Room and Duct CO transmitters are offered in a standard NEMA 1 rated ABS Polycarbonate plastic enclosure. An optional NEMA 4X watertight and dust proof enclosure is only available with the CO room transmitter.
-
Product
Carbon Dioxide (CO2) Gas Leak Detector
-
Carbon dioxide detectors detects the presence of CO2 molecules in the air based on the absorption of infrared light.
-
Product
Carbon / Sulfur Analyzer
ELEMENTRAC CS‑d
-
ELTRA's ELEMENTRAC CS-d is the only analyzer in the market for determination of carbon and sulfur in organic as well as inorganic samples. For this purpose, the ELEMENTRAC CS-d is equipped with both an induction and a resistance furnace (ELTRA Dual Furnace Technology), covering the full range of carbon and sulfur analysis.
-
Product
CO Carbon Monoxide Probe
HD320A2
-
HD320A2 is a probe to be used with the HD32.1 Thermal Comfort data logger.
-
Product
Platform for Identifying Strategic Opportunities for Reducing Whole-Life Carbon
Carbon First
-
Carbon First is an award-winning platform that helps you identify strategic opportunities for reducing whole-life carbon in the early planning and design phases of infrastructure projects or portfolios.It empowers users to act earlier on net-zero strategies by highlighting bespoke carbon reduction opportunities and helping you set accurate Key Performance Indicators. It runs and compares multiple options on a visual dashboard quickly and easily, empowering companies to act effectively on net-zero goals and regulatory requirements.This digital innovation enables front-end loading in project planning, helping projects and portfolios be more successful and efficient across entire life cycles. Carbon First harnesses the highly respected Institute of Civil Engineer’s’ (ICE) Project 13 principles in infrastructure delivery, especially within digital transformation. These principles are designed to boost delivery productivity and certainty, improve whole-life outcomes, and support a more sustainable, innovative, highly skilled industry.
-
Product
Keysight Multifunction Module with 32-bit DIO, 2-ch D/A and Totalizer for 34980A
34952A
-
The Keysight 34952A module for the 34980A Multifunction Switch/Measure Unit allows great flexibility for a variety of sense and control applications.It combines the following on a single earth-referenced module:
-
Product
Carbon Monoxide Detectors
Inspector CO Detectors
-
Sensorcon, Sensing Solutions by Molex believes in the importance of a dependable gas detector. Featuring proprietary engineering & software, our Inspector Series utilizes electrochemical sensors for fast & accurate measurements of CO.
-
Product
UV Fluorescence Total Reduced Sulfur Analyzer
Model T102
-
The Model T102 TRS analyzer uses the proven UV fluorescence principle to measure Total Reduced Sulfur at levels commonly required for ambient air monitoring.The Model T102 uses a high temperature external converter set at 850°C to allow conversion of H2S, methyl mercaptan, dimethyldisulfide, and methyl-disulfide to SO2 at this temperature with efficiency greater than 98%. A switching option alternately measures TRS and SO2 while showing both readings concurrently on the front display.All T Series instruments offer an advanced color display, capacitive touch screen, intuitive user interface, flexible I/O, and built-in data acquisition capability. All instrument set up, control and access to stored data and diagnostic information is available through the front panel, or via RS232, Ethernet, or USB com ports, either locally or by remote connection.The Model T102 comes with NumaView ™ Software. NumaView™ Remote PC Software allows for a remote connection with virtual interface and data downloading capability to analyzers operating NumaView ™ Software.
-
Product
Volatile Organic Compound VOC Meters, Monitors
-
For handheld and long-term VOC measurement and logging.
-
Product
High Carbon Process Carrier Pallets
Composite Family
-
High Strength, high temperature, semiconductive composite board designed for use as circuit board and flex circuit carrying pallets for solder reflow ovens.
-
Product
Ultra-Low Range Gas Filter Correlation Carbon Monoxide Analyzer
Model T300U
-
The Model T300U Trace-level CO analyzer has been developed specifically to address the challenges of low level monitoring as required, for example, in the US NCore network. Using IR absorption with a Gas Filter Correlation Wheel, the T300U is designed to allow ultra-sensitive CO measurements while still meeting the requirements for use as a US EPA compliance analyzer.The optical bench is enclosed in a temperature controlled oven, dramatically decreasing instrument noise and drift. The objective and field mirrors in the sample cell are gold plated to maximize signal to noise performance, while a temperature-controlled Nafion dryer on the inlet minimizes water interference caused by ambient humidity changes. Periodically, the T300U seamlessly corrects its baseline by routing the sample through a heated catalytic CO scrubber. This Auto Reference function corrects zero drift and reduces the effect of interferences.All T Series instruments offer an advanced color display, capacitive touch screen, intuitive user interface, flexible I/O, and built-in data acquisition capability. All instrument set up, control and access to stored data and diagnostic information is available through the front panel, or via RS232, Ethernet, or USB com ports, either locally or by remote connection.The Model T300U comes with NumaView™ Software. NumaView™ Remote PC Software allows for a remote connection with virtual interface and data downloading capability to analyzers operating NumaView™ Software.
-
Product
Total Effective Irradiance Probe
LP471A-Uveff
-
The combined probe LP471A-UVeff measures the Total Effective Irradiance (W/m²) weighted according to the UV action curve (CEI EN 60335-2-27).
-
Product
Carbon Monoxide Detector Tester
Solo C3
-
Many multi-sensor fire detectors detect carbon monoxide (CO) as well as smoke and / or heat. Under international codes and standards the CO cell needs to be functionally tested with a CO stimulus from the protected area through the detector vents to the sensor.
-
Product
Reverse Osmosis Meters For Measuring Total Dissolved Solids
RO Meters™
-
The choice of professionals for years, this compact instrument has been designed specifically to demonstrate and test Point of Use (POU) reverse osmosis or distillation systems. By measuring electrical conductivity, it will quickly determine the parts per million/Total Dissolved Solids (ppm/TDS) of any drinking water.
-
Product
Automated Total Nitrosamine Analyser
-
Ellutia Chromatography Solutions
Nitrosamines are carcinogenic compounds that can be found and formed in many products. This has been a particular issue in the pharmaceutical industry recently. Traditional approaches to the analysis, such as by mass spec, have been challenging due to the low detection levels required, the possibility of false positives, or even missing. This system takes a unique approach of using the combination of a chemical reaction targeting nitrosamine compounds, then detection by a detector with very high selectivity and sensitivity for nitro/nitroso compounds. Rather than speciating the various nitrosamines present, the system gives a single quantitative result down to 1 ppb for the total nitrosamine content. This means both volatile and non-volatile nitrosamines are measured at the same time. This process is automated to allow a high sample throughput. This makes it ideal for screening a large number of samples rapidly.