Passive Intermodulation
1.) Protocol Independent Multicast - network routing over existing unicast framework. 2.) Passive InterModulation - RF interference generation condition.
-
Product
Passive Oscilloscope Probes
5900 SERIES
-
Probe Master's new 5900 series passive oscilloscope probes are available in 400 MHz & 500 MHz bandwidths. Probes are also available with readout actuators for oscilloscopes with the readout feature. The "GOLD PROBE" has been designed specifically for use with Tektronix, Hewlett Packard and other high performance oscilloscopes. This new slim design along with a host of versatile accessories, allows you to reach the most difficult test point in today's highly complex circuitry. The gold plated Probe Tips, Sprung Hook, Ground Lead, Alligator Tip and other critical interconnect points within the Gold Probe, provide excellent contacts for probing low level analog signals and high speed digital data. Unlike most "off shore" commodity probes, Probe Master guarantees quality and continuing domestic support for our "Made in America" Gold Probe.The probe body is made of high impact ABS. Soft molded strain reliefs at all stress points assure long cable life. In short it has been designed to offer you high performance coupled with high quality.
-
Product
Passive XMC-to-PCI Express Adapter
5935
-
The Technobox, Inc. P/N 5935 is designed to adapt a single-wide XMC card to a 1X PCI Express slot. The 5934 supports P15 only and allows access to PN4 signal via the adapter's DIN connector. The A and C rows of a 96-pin DIN connector connect with the 64-pin user I/O connector (J4/P4) on the mezzanine card, permitting internal connection of rear I/O.
-
Product
GPS Antenna Signal Splitter 6 Way, N Type, Passive, L1 & L2, 50 Ohm
GPS600
-
INSTOCK Wireless Components, Inc
GPS L1 - L5, GLONASS, Galileo SplitterLow Insertion Loss (0.3 dB avg)High Port to Port Isolation (30 dB avg)Excellent VSWR (1.10 : 1 avg)15 VDC & 75 mA max on DC block portsRoHS Compliant Splitter Construction
-
Product
High Voltage Passive Probes
-
The PPE6KV-A and HVP120 can handle up to 6000 Vpeak transient overvoltages and are designed for probing up to 2000 Vrms and 1000 Vrms respectively. Fast rise times, excellent frequency response, and a variety of standard accessories make these probes safe and ideal for high voltage measurement applications
-
Product
GPS Antenna Signal Splitter 3 Way, SMA Jack, Passive, L1 & L2, 50 Ohm
GPS310
-
INSTOCK Wireless Components, Inc
GPS L1 - L5, GLONASS, Galileo SplitterLow Insertion Loss (0.3 dB avg)High Port to Port Isolation (30 dB avg)Excellent VSWR (1.10 : 1 avg)15 VDC & 75 mA max on DC block portsRoHS Compliant Splitter Construction
-
Product
5-slot ATX-supported 2U Butterfly PICMG 1.3 Bus Passive Backplane
FAB105-V1
-
*Designed for PICMG 1.3 SBC*Compatible with the AX61222TP/AX61220TP chassis*Supports one PICMG 1.3 CPU card slot, one PCIe x16 slot, and three 32bit/33MHz PCI slots
-
Product
Passive FTTx
-
Shenzhen Wiitek Technology Co.,Ltd
Fiber to the x (FTTX; also spelled "fibre") or fiber in the loop is a generic term for any broadband network architecture using optical fiber to provide all or part of the local loop used for last mile telecommunications. As fiber optic cables are able to carry much more data than copper cables, especially over long distances, copper telephone networks built in the 20th century are being replaced by fiber.
-
Product
500 MHz Passive Probe, 2.5mm, 10:1, 10 MOhm
PP021-1
-
Passive probes are the standard probe provided with most oscilloscopes. Typical passive probes provide a 10:1 attenuation and feature a high input resistance of 10 MΩ. This high input resistance means that passive probes are the ideal tool for low frequency signals since circuit loading at these frequencies is minimized. Passive probes are designed to handle voltages of at least 400V, some as high as 600V. Teledyne LeCroy passive probes feature an attenuation sense pin which tells the oscilloscope to scale the waveforms automatically requiring no user input.
-
Product
2 Way GPS / GNSS Signal Splitter IP67 Outdoor, N Type, 1-2 GHz, 50 Ohm, Passive
GPS201
-
INSTOCK Wireless Components, Inc
GPS L1 - L5, GLONASS, Galileo splitterLow Insertion Loss (0.2 dB avg)High Port to Port Isolation (30 dB avg)Excellent VSWR (1.10 : 1 avg)15 VDC & 75 mA max on DC block portTri Alloy N Type Female (Jack) 50 Ohm
-
Product
Thick Film Passive Element
GBR-403
-
GBR-403 series high voltage resistors are made in a thick film technology on ceramic substrates (Al2O3 96%). These elements are used in high voltage applications requiring high stability and resistance.
-
Product
Passive Probe, 10:1, 500 MHz, 1.2 M
N2843A
-
The Keysight N2843A low-cost passive probe provides a 10:1 attenuation and features a high input resistance of 10 MΩ. The probe can be adjusted for low-frequency compensation and high-frequency compensation.
-
Product
Attenuation 100 High Voltage Passive Probe
-
Safe high voltage probe solutions for ground-referenced voltage testing. It is critical to safely and accurately capture real-time signal information from "elevated" or "floating" voltage systems.
-
Product
Thick Film Passive Element
GBR-181
-
GBR-181series resistors are made in a thick film technology, or ceramic substrates (Al2O3) - 96&). Thick film resistors are characterized by a higher stability, and lower noises than a typical carbon resistors. The whole of resistor is encapsulated with epoxy resin by fluidization process. GBR-181 series elements are used both for general, and professional applications. Other values of resistance, and tolerance (up to 0.1%) are available on request.
-
Product
10:1 500 MHz 10 MOhms Passive Probe
PP005A
-
Passive probes are the standard probe provided with most oscilloscopes. Typical passive probes provide a 10:1 attenuation and feature a high input resistance of 10 MO. This high input resistance means that passive probes are the ideal tool for low frequency signals since circuit loading at these frequencies is minimized. Passive probes are designed to handle voltages of at least 400V, some as high as 600V. Teledyne LeCroy passive probes feature an attenuation sense pin which tells the oscilloscope to scale the waveforms automatically requiring no user input.
-
Product
MPU- Passive Sensors
-
sensors of the MPU series are passive elements intended for measuring rotational speeds or speeds of moving parts. The measuring principle is based on voltage induction in the coil through a changing magnetic field, which is caused, for example, by a rotating ferromagnetic gear. The coil is wound on a magnetic core and led out via a cable or a plug. The sensors are manufactured with metric or inch threads or with a flange connection and deliver a sinusoidal output signal, the amplitude of which is proportional to the peripheral speed. They can be connected to Orbit Controls evaluation devices. An OC35-IMP transmitter is available for converting to square-wave signals.
-
Product
CP500X, 500 MHz, ±60 V, 10X Attenuation, Single-Ended Passive Oscilloscope Probe
784253-01
-
The CP500X is a coaxial passive probe with fixed 10X attenuation for oscilloscopes that provide 1 MΩ input impedance. It is 1 meter in length. The CP500X attaches to BNC connections on both the signal input and instrument sides.
-
Product
Integrated Passive Devices
-
Macom Technology Solutions Holdings Inc.
MACOM’s new Integrated Passive Devices (IPD) products can be used in a wide range of aerospace and defense, wireless, and test and measurement applications. These IPD devices implement various functions such as baluns, couplers and power dividers, and are available in PQFN or bare die. Operating over the 2 GHz to 20 GHz frequency range our IPD products offer excellent performance over wide bandwidths.
-
Product
3-slot ATX-supported 1U Butterfly PICMG 1.3 Bus Passive Backplane
FAB209
-
*Designed for PICMG 1.3 SBC*Compatible with AX61120TP chassis*Supports one PICMG 1.3 CPU card slot, one PCIe x4 slot and one PCIe x16 slot
-
Product
Passive Component Storage Module Series
TrayPXIe
-
The TrayPXIe is an accessory tray that stores your fragile passive fiber optic components such as splitters, connector adaptor patchcords, WDM couplers, and isolators in one handy module in the PXI chassis.
-
Product
500 MHz Passive Probe, 5mm, 10:1, 10 MOhm
PP024-1
-
Passive probes are the standard probe provided with most oscilloscopes. Typical passive probes provide a 10:1 attenuation and feature a high input resistance of 10 MΩ. This high input resistance means that passive probes are the ideal tool for low frequency signals since circuit loading at these frequencies is minimized. Passive probes are designed to handle voltages of at least 400V, some as high as 600V. Teledyne LeCroy passive probes feature an attenuation sense pin which tells the oscilloscope to scale the waveforms automatically requiring no user input.Each passive probe is recommended for a certain oscilloscope, using the right passive probe with the right oscilloscope means that the probe will be properly compensated across the entire bandwidth. Using probes with a different oscilloscope will only let you compensate for low frequencies.
-
Product
3 Way GPS / GNSS Signal Splitter Passive, 1-2 GHz, N Type, DC Block+200Ω Load 3 Ports
GPS302
-
INSTOCK Wireless Components, Inc
GPS L1 - L5, GLONASS, Galileo splitterLow Insertion Loss (0.3 dB avg)High Port to Port Isolation (30 dB avg)Excellent VSWR (1.10 : 1 avg)15 VDC & 75 mA max on DC block portsTri Alloy N Type Female (Jack) 50 Ohm
-
Product
Passives
-
Blonder Tongue Laboratories, Inc.
The staple of any cable TV installation, Blonder Tongue's wide range of Passives will surely meet the needs of your application. Offered in a variety of outputs and dB values, we have the product that will put the finishing touch on your installation.
-
Product
500 MHz Passive Probe, 2.5mm, 10:1, 10 MOhm
PP022-1
-
Passive probes are the standard probe provided with most oscilloscopes. Typical passive probes provide a 10:1 attenuation and feature a high input resistance of 10 MΩ. This high input resistance means that passive probes are the ideal tool for low frequency signals since circuit loading at these frequencies is minimized. Passive probes are designed to handle voltages of at least 400V, some as high as 600V. Teledyne LeCroy passive probes feature an attenuation sense pin which tells the oscilloscope to scale the waveforms automatically requiring no user input.Each passive probe is recommended for a certain oscilloscope, using the right passive probe with the right oscilloscope means that the probe will be properly compensated across the entire bandwidth. Using probes with a different oscilloscope will only let you compensate for low frequencies.
-
Product
Passive Backplanes
-
A wide range of ADLINK backplanes are available for PICMG CPU cards. They are the most flexible and expansible solutions for industrial slot-hungry applications.
-
Product
High Performance Passive Antenna, Waterproof, Wide Operating Temperature Range, IP67 Level
AIW-521
-
Passive antennaIP67-ratedGPS-L1: 1575.42 MHz/GLONASS-G1: 1589.0625 MHz/GALILEO-E1: 1575.42 MHz/BeiDou-B1/B1-2: 1561.098/1589.742 MHzSMA male connectorOperating Temperature: -40 ~ 85℃
-
Product
Passive Probe, 1:1, 20 MHz, 1.5 M
10070D
-
The Keysight 10070D 20 MHz passive probe is a great choice if you are looking for high quality at a very reasonable price. This general purpose probe is designed specifically to give you optimal performance with your 5000, 6000, 7000 Series, 54620 Series and 9000 Series oscilloscopes. Rugged enough for general-purpose measurements, the 10070D features a durable cable and a solid stainless-steel probe body encased with a hard, fracture-resistant plastic.
-
Product
Passive Network TAPs
ApconTap
-
Our portfolio of passive optical network TAPs captures network traffic under all conditions to simplify network monitoring and security. Each ApconTap model supports common datacenter optical fiber standards with split ratio options availble at 50/50, 60/40, and 70/30. With passive fiber 40G and 100G TAPs, APCON offers short-range, long-range, and bidirectional models to accomodate requirements for high-density, next-generation datacenter deployments.
-
Product
Passive Probe, 10:1, 500 MHz, 1.3 M
N2873A
-
The N2873A passive probe offers DC to 500 MHz and 10:1 attenuation factor to address a wide range of measurement needs.
-
Product
GPS, GLONASS, Galileo Micro Splitter 2 Way, SMA, 1176.45 - 1602.00 MHz, 50 Ohm, Passive
GPSL15
-
INSTOCK Wireless Components, Inc
GPSL15 is a two way, passive, GPS signal splitter ideal for splitting a GPS antenna signal between two receivers while providing a DC current path to power a remotely located active GPS antenna from one receiver while blocking the DC path from the other. Max voltage rating at the DC blocked port is 10 VDC; maximum current rating is 50 mA. Maximum voltage rating at the DC pass port is 50 VDC; max current rating is 1000 mA. Furnished with SMA female connectors all ports. Being a "micro-sized" splitter, GPSL10 weighs only 21 grams and is suitable for applications requiring low-weight parts.
-
Product
3 Way GPS / GNSS Signal Splitter IP67 Outdoor, N Type, 1-2 GHz, 50 Ohm, Passive
GPS301
-
INSTOCK Wireless Components, Inc
GPS L1 - L5, GLONASS, Galileo SplitterLow Insertion Loss (0.3 dB avg)High Port to Port Isolation (30 dB avg)Excellent VSWR (1.10 : 1 avg)15 VDC & 75 mA max on DC block portsTri Alloy N Type Female (Jack) 50 Ohm