1.) Protocol Independent Multicast - network routing over existing unicast framework. 2.) Passive InterModulation - RF interference generation condition.
-
Product
14-slot ATX-supported PICMG 1.3 Bus Passive Backplane
FAB118
-
The FAB118 offers one PCIe x16 slot, five PCIe x4 slots and six 32bit/33MHz PCI slots as well as the PICMG 1.3 slot for the SHB (system host board). The onboard 24-pin ATX power connector and 8-pin connector for thermal detected board are featured. Furthermore, the backplane supports two high speed USB 2.0 ports. The FAB118 is designed for the 14-slot industrial chassis, such as Axiomtek's AX61460, AX6145, AX61400, AX6156E/LE/LLE, and AX61491.
-
Product
Passive Tapping Solution
GPON Phantom™
-
GPON Phantom™ is a unique passive tapping device for Lawful Interception (LI) of optical fiber lines using GPON technology and deployed in a Fiber-to-the-x (FTTx) topology. The GPON Phantom records and stores broadband digital information, offering unique advantages for Law Enforcement Authorities (LEAs) looking to capture any data between the central office and the target, without being detected, while providing solid evidence with unique identification of the target.
-
Product
Passive Probe, 10:1, 300 MHz, 1.2 M
N2842A
-
The Keysight N2842A low-cost passive probe provides a 10:1 attenuation and features a high input resistance of 10 MΩ. The probe can be adjusted for low-frequency compensation and high-frequency compensation.
-
Product
Passive XMC-to-PCI Express Adapter
6066
-
Our Passive XMC-to-PCI Express Adapter +5VPWR 4X (6066) is designed to adapt a single-wide XMC card to a 4X PCI Express slot. The 6067 supports P15 only and allows access to PN4 signal via the adapter's DIN connector. The A and C rows of a 96-pin DIN connector connect with the 64-pin user I/O connector (J4/P4) on the mezzanine card.
-
Product
Passive Optical TAPs
SplitLight
-
Designed for networks with high fiber counts, SplitLight is a patented and customizable 1RU solution offering the industry's highest density of Passive Optical Network TAPs, WDMs, and wavelength filters in a 1RU chassis. Using this platform, service providers, data centers, large enterprises, and government agencies can now monitor more fibers, or filter and route more wavelengths, than ever before while saving valuable rack space.
-
Product
Passive Probe Interface Adapter
CX1151A
-
The CX1151A is an adapter for passive probes for the voltage waveform measurements by the CX3300 series Device Current Waveform Analyzer.
-
Product
GPS, GLONASS, Galileo Splitter 2 Way, N Type, 1000 - 2000 MHz, 50 Ohm, Passive
GPS200
-
INSTOCK Wireless Components, Inc
GPS L1 - L5, GLONASS, Galileo splitterLow Insertion Loss (0.2 dB avg)High Port to Port Isolation (30 dB avg)Excellent VSWR (1.10 : 1 avg)15 VDC & 75 mA max on DC block portTri Alloy N Type Female (Jack) 50 Ohm
-
Product
250 MHz Passive Probe for HDO4000, 10:1, 10 MOhm
PP017-1
-
Passive probes are the standard probe provided with most oscilloscopes. Typical passive probes provide a 10:1 attenuation and feature a high input resistance of 10 MΩ. This high input resistance means that passive probes are the ideal tool for low frequency signals since circuit loading at these frequencies is minimized. Passive probes are designed to handle voltages of at least 400V, some as high as 600V. Teledyne LeCroy passive probes feature an attenuation sense pin which tells the oscilloscope to scale the waveforms automatically requiring no user input.Each passive probe is recommended for a certain oscilloscope, using the right passive probe with the right oscilloscope means that the probe will be properly compensated across the entire bandwidth. Using probes with a different oscilloscope will only let you compensate for low frequencies.
-
Product
500 MHz Passive Probe, 2.5mm, 10:1, 10 MOhm
PP022-1
-
Passive probes are the standard probe provided with most oscilloscopes. Typical passive probes provide a 10:1 attenuation and feature a high input resistance of 10 MΩ. This high input resistance means that passive probes are the ideal tool for low frequency signals since circuit loading at these frequencies is minimized. Passive probes are designed to handle voltages of at least 400V, some as high as 600V. Teledyne LeCroy passive probes feature an attenuation sense pin which tells the oscilloscope to scale the waveforms automatically requiring no user input.Each passive probe is recommended for a certain oscilloscope, using the right passive probe with the right oscilloscope means that the probe will be properly compensated across the entire bandwidth. Using probes with a different oscilloscope will only let you compensate for low frequencies.
-
Product
GPS, GLONASS, Galileo Splitter 8 Way, N-Type, 1000 - 2000 MHz, 50 Ohm, Passive
GPS800
-
INSTOCK Wireless Components, Inc
GPS L1 - L5, GLONASS, Galileo SplitterLow Insertion Loss (0.6 dB avg)High Port to Port Isolation (30 dB avg)Excellent VSWR (1.15 : 1 avg)15 VDC & 75 mA Max on DC Block PortsRoHS Compliant Splitter Construction
-
Product
Passive and Active Resistor Trimming for Thick and Thin Film
LRT 2000L
-
*Travel: 6" x 6"*Laser : Fiber Laser Ytterbium 1064 nm*Kerf: 30 to 80 micron Adjustable*Pulse width : 80 nano second*Rap Rate: 1 to 1 million Pulse Per Second*Average Power: 20 watts*Target: Electric crosshair on monitor
-
Product
÷10, 500 MHz, 10 MΩ, Passive Probe
PP009-1
-
Passive probes are the standard probe provided with most oscilloscopes. Typical passive probes provide a 10:1 attenuation and feature a high input resistance of 10 MΩ. This high input resistance means that passive probes are the ideal tool for low frequency signals since circuit loading at these frequencies is minimized. Passive probes are designed to handle voltages of at least 400V, some as high as 600V. Teledyne LeCroy passive probes feature an attenuation sense pin which tells the oscilloscope to scale the waveforms automatically requiring no user input.Each passive probe is recommended for a certain oscilloscope, using the right passive probe with the right oscilloscope means that the probe will be properly compensated across the entire bandwidth. Using probes with a different oscilloscope will only let you compensate for low frequencies.
-
Product
Passive Tapping Device
DSL Phantom™
-
DSL Phantom™ is a unique passive tapping device for Lawful Interception (LI) of ADSL lines. The device records and stores broadband digital information, offering unique advantages to Law Enforcement Authorities (LEAs) looking to capture data between the target and the service provider premises.
-
Product
Thunderbolt 3 Type-C Cable, Passive 20 Gbps, 5A, 2m
785608-02
-
24-Pin USB-C Male to 24-Pin USB-C Male Thunderbolt™ Cable - The Thunderbolt 3 Male-to-Male Cable provides a USB-C connection for PXI chassis and controllers. This cable supports passive or active 40 Gbps or passive 20 Gbps data transfer speeds. The Thunderbolt 3 Male-to-Male Cable is available in 0.8 m or 2 m lengths. Thunderbolt and the Thunderbolt logo are trademarks of Intel Corporation or its subsidiaries in the US and/or other countries.
-
Product
3 Way GPS / GNSS Signal Splitter Passive, 1-2 GHz, SMA, DC Block+200Ω Load 3 Ports
GPS312
-
INSTOCK Wireless Components, Inc
GPS L1 - L5, GLONASS, Galileo splitterLow Insertion Loss (0.3 dB avg)High Port to Port Isolation (30 dB avg)Excellent VSWR (1.10 : 1 avg)15 VDC & 75 mA max on DC block portsTri Alloy SMA Female (Jack) 50 Ohm
-
Product
GPS, GLONASS, Galileo Splitter 2 Way, SMA, 1000 - 2000 MHz, 50 Ohm, Passive
GPS210
-
INSTOCK Wireless Components, Inc
GPS L1 - L5, GLONASS, Galileo splitterLow Insertion Loss (0.2 dB avg)High Port to Port Isolation (30 dB avg)Excellent VSWR (1.10 : 1 avg)15 VDC & 75 mA max on DC block portTri Alloy SMA Female (Jack) 50 Ohm
-
Product
GPS, GLONASS, Galileo Micro Splitter 2 Way, SMA, 1176.45 - 1602.00 MHz, 50 Ohm, Passive
GPSL10
-
INSTOCK Wireless Components, Inc
GPSL10 is a two way, passive, GPS signal splitter ideal for splitting a GPS antenna signal between two receivers while providing a DC current path to power a remotely located active GPS antenna from one receiver while blocking the DC path from the other. Max voltage rating is 50 VDC; maximum current rating is 1000 mA. Furnished with SMA female connectors all ports. Being a "micro-sized" splitter, GPSL10 weighs only 21 grams and is suitable for applications requiring low-weight parts.
-
Product
2 Way GPS / GNSS Signal Splitter Passive, 1-2 GHz, N Type, DC Block+200Ω Load 2 Ports
GPS202
-
INSTOCK Wireless Components, Inc
PS L1 - L5, GLONASS, Galileo splitterLow Insertion Loss (0.2 dB avg)High Port to Port Isolation (30 dB avg)Excellent VSWR (1.10 : 1 avg)15 VDC & 75 mA max on DC block portsTri Alloy N Type Female (Jack) 50 Ohm
-
Product
GPS, GLONASS, Galileo Splitter 3 Way, TNC, 1000 - 2000 MHz, 50 Ohm, Passive
GPS320
-
INSTOCK Wireless Components, Inc
GPS L1 - L5, GLONASS, Galileo splitterLow Insertion Loss (0.2 dB avg)High Port to Port Isolation (30 dB avg)Excellent VSWR (1.10 : 1 avg)15 VDC & 75 mA max on DC block portsTri Alloy TNC Female (Jack) 50 Ohm
-
Product
CP500X, 500 MHz, ±60 V, 10X Attenuation, Single-Ended Passive Oscilloscope Probe
784253-01
-
The CP500X is a coaxial passive probe with fixed 10X attenuation for oscilloscopes that provide 1 MΩ input impedance. It is 1 meter in length. The CP500X attaches to BNC connections on both the signal input and instrument sides.
-
Product
ABex Passive Terminal Module for Meilhaus ME-9000
ABex TM-ME-9000
-
The ABex TM-ME-9000 is an ABex terminal module for the ABex system to route signals from a Meilhaus ME-9000 device to the front connector of the ABex. It is only a feedthrough-module.
-
Product
Thick Film Passive Element
GBR-182
-
GBR-182 series resistors are made in a thick film technology, on ceramic substrates (Al2O3 - 96%). Thick film resistors are characterized by a higher stability, and lower noises than a typical carbon resistors. The whole of resistor is encapsulated with epoxy resin by fluidization process. GBR-182 series elements are used both for general, and professional applications.
-
Product
Passive probe with X1/X10 switch
-
They are normally designated X1 and X10, although 1X and 10X are sometimes seen. The designation refers to the factor by which the impedance of the scope itelf is multiplied by the probe.The X1 probes are suitable for many low frequency applications. They offer the same input impedance of the oscilloscope which is normally 1 MΩ. However for applications where better accuracy is needed and as frequencies start to rise, other test probes are needed.
-
Product
500 MHz Passive Probe for WaveJet Touch, 10:1, 10 MOhm
PP006D
-
Passive probes are the standard probe provided with most oscilloscopes. Typical passive probes provide a 10:1 attenuation and feature a high input resistance of 10 MΩ. This high input resistance means that passive probes are the ideal tool for low frequency signals since circuit loading at these frequencies is minimized. Passive probes are designed to handle voltages of at least 400V, some as high as 600V. Teledyne LeCroy passive probes feature an attenuation sense pin which tells the oscilloscope to scale the waveforms automatically requiring no user input.
-
Product
11-slot ATX-supported PICMG 1.3 Bus Passive Backplane
FAB121
-
*Designed for PICMG 1.3 SBC*Compatible with AX61410, AX6145, AX6156 chassis*Supports one PICMG 1.3 CPU card slot, seven PCIe x4 slots, one PCIe x8 slot, and two 32bit/33MHz PCI slots
-
Product
T3DSO Passive Probe, 350 MHz, 10X, 10 MOhm, 300V/600V
T3PP350A
-
Passive probes are the standard probe provided with most oscilloscopes. Typical passive probes provide a 10:1 attenuation and feature a high input resistance of 10 MΩ. This high input resistance means that passive probes are the ideal tool for low frequency signals since circuit loading at these frequencies is minimized. Passive probes are designed to handle voltages of at least 400V, some as high as 600V. Teledyne LeCroy passive probes feature an attenuation sense pin which tells the oscilloscope to scale the waveforms automatically requiring no user input.
-
Product
Components - Passive Multipliers (FT)
FT Series
-
Farran Technology manufactures a series of standard frequency multipliers which are available in fixed or tunable versions. GaAs Schottky barrier varactors are used to achieve the highest efficiency. The multipliers can be used with solid state or vacuum tube sources. A rugged compact mechanical design is used to maximise reliability.
-
Product
MPU- Passive Sensors
-
sensors of the MPU series are passive elements intended for measuring rotational speeds or speeds of moving parts. The measuring principle is based on voltage induction in the coil through a changing magnetic field, which is caused, for example, by a rotating ferromagnetic gear. The coil is wound on a magnetic core and led out via a cable or a plug. The sensors are manufactured with metric or inch threads or with a flange connection and deliver a sinusoidal output signal, the amplitude of which is proportional to the peripheral speed. They can be connected to Orbit Controls evaluation devices. An OC35-IMP transmitter is available for converting to square-wave signals.