Product
Air Pollution Multigas Calibrator
APMC-370
-
Dilution of gases with high accuracy and precision requires high quality MFC’s, especially for high dilution ratios and ranges. Consequently HORIBA’s APMC-370 is equipped with digital MFC’s. These MFC’s are factory calibrated, optional also with a special Polynomial Calibration. HORIBA Europe‘s APMC-370 is designed to calibrate gas analyzers manually, remotely controlled or automatically. It is installed in air pollution monitoring stations for quality assurance in the laboratory and also in the production of gas analyzers.
-
Product
Automatic Air Purging Tank
MF-015
-
If the fuel passing through a flow detector has mixing of air, the flow rate cannot be measured correctly. The MF-015 is an automatic air purging tank that uses a precision float valve. When fluid enters the flow line, the air is automatically purged to the atmosphere.
-
Product
Photochemical Pollution Monitoring System
-
Are large-scale air quality models that simulate the changes of pollutant concentrations in the atmosphere using a set of mathematical equations characterizing the chemical and physical processes in the atmosphere.
-
Product
Electromagnets
-
The Lake Shore electromagnets (EM-V Series) produce magnetic fields with a variety of indexed air gap and pole cap configurations. The EM-V Series is ideally suited for integration into customer-designed magnetic test platforms for applications including magneto-optical studies, magnetic hysteresis studies, in-line annealing, Hall effect studies, susceptibility measurements, spin magnetic resonance demonstrations, and biological studies.
-
Product
Smart Indoor Air Quality Monitor
-
You want to provide the healthiest home possible for your family. Netatmo’s Smart Indoor Air Quality Monitor shows you how. Whether it's the CO2 levels for avoiding headaches while working from home, the right humidity levels for a child with asthma or the best noise level for sound sleeping.
-
Product
CO2 Concentration Transmitter
H5424
-
The regulators are designed for online measurement of temperature (C or F), relative humidity and carbon dioxide concentration of air without aggressive ingredients. Measured temperature and relative humidity are recomputed to following humidity expression: dew point temperature, absolute humidity, specific humidity, mixing ratio and specific enthalpy.
-
Product
High and Low Temperature Humidity Chamber
GDJS/GDJW
-
•The chamber is produced by SUS304 Steel, the temperature keeping material is produced by Polyurethane hard foam and ultra-fine fibre glass, the doorframe heat insulated by Double high temperature aging silicone rubber door sealing strip. •The temperature controller is used by Korean TEMI display in English/Chinese and German Siemens PLC, it can be communicated to PC via RS-232. The temperature accuracy is 0.1℃ and humidity is 0.1%R.H •The temperature sensor is platinum PT100 Ohms/MV resistor •The heating system is full separately system which produced by Nickel chromium alloy electric heating type heater •The cold system is applied by fully enclosed fan cooled single-stage and cascade refrigeration mode, the compressor is from France TECUMSEH brand which can allow you get after sales support from many countries •The cyclical system is applied by High temperature low noise air conditioning type motor and Multi blade centrifugal wind wheel •The safety self-protection function include Electric leakage, short circuit, over temperature, motor overheating, compressor pressure, overload, over-current protection •Working Power: AC380V±10% 3phases and frequency 50Hz/60Hz •Working Environmental: Temperature is 5℃~+30℃ Humidity ≤85%R.H
-
Product
Thermacon Request to Exit Sensor
T-80 and S-80
-
These units are designed for easy concealed installation in suspended ceilings or on an enclosed metal electrical box is acceptable for use in air handling areas. In addition to the four standard interchangeable detection patterns, others may be custom made.
-
Product
Pressure Gas Leak Detectors
-
The testo 512 differential pressure meter is available as four models. This model has a measuring range from 0.0.29 psi and is ideal for measuring pressure differences at filters and for carrying out pitot static tube measurements in air ducts at air flow speeds between 16 and 180 fps.
-
Product
Mass Air Flow Sensors
-
Mass air flow sensors are one of the essential components of an electronic fuel injection systems. They measure the amount of air entering the engine, or the air flow. Our reliable and accurate mass air flow (MAF) sensors help detect the mass of air flow in a variety of automotive, medical and industrial gas applications.
-
Product
Nitrogen Compound Instruments
-
Teledyne Advanced Pollution Instrumentation
Teledyne API produces a wide range of instruments for the measurement of Nitrogen compounds, including those that measure 'True NO2'. All T Series instruments offer two front-panel USB ports, an advanced touch screen full color display, customizable user interface with predictive maintenance alerts, one-touch real-time graphing, and multiple language support. All of our instruments are designed meet the rigorous demands of ambient air quality, stack, or industrial process gas monitoring
-
Product
OM Thermal Stress System
-
Conductor Analysis Technologies, Inc
The OM Thermal Stress System is a cost-effective performance based reliability test methodology which performs convection reflow assembly simulation and air-to-air thermal cycling. The methodology is utilized by both the IPC PCQR and the IPC 6012-QLM programs. OM systems are available for sale or lease, and test services are provided from both CAT and our service partners.
-
Product
Sound Level Meters
-
A sound level meter is used for acoustic (sound that travels through air) measurements. It is commonly a hand-held instrument with a microphone. The diaphrahm of the microphone responds to changes in air pressure caused by sound waves.
-
Product
Scalable Multi-Channel Active Thermal Control (ATC)
T-Core Thermal Control System
-
Cohu’s proprietary T-Core thermal system’s controller provides precise, multi-site temperature management of power dissipation ICs, such as graphic chips and CPUs, optimizing test yield.The T-Core thermal control system optimizes test yield at cold, ambient, and hot temperatures and offers better than +/- 1°C accuracy with response speeds of >125°C/sec. The system’s flexibility to control air, liquid, and refrigerant based thermal heads gives semiconductor manufacturers excellent temperature control capability for high volume manufacturing.
-
Product
LAGRANGIAN DRIFTERS
SVP
-
SVP drifters track currents at depths of 5 to 100 meters, and are equipped to accommodate a range of additional sensors. Standard drifter sensor configurations include sea surface temperature, air pressure, wind velocity, and salinity
-
Product
Paper Testing Instruments
-
Whiteness and chromaciticity tester, whiteness meter, tensile stiffness tester, automatic horizontal tensile tester, automatic horizontal tensile tester, vertical tensile tester, pulp beating (refining) freeness tester, water absorbtion tester, Cobb tester, COBB sample cutter, coefficient of friction tester, electronic bending stiffness tester, paper and cardboard thickness meter, paper and cardboard thickness meter, ink rubber tester, standard strip cutter, softness tester, carton compression tester, paper air permeability tester, internal ply bond tester, puncture strength tester, paper tearing tester, electronic tearing tester, mullen burst tester, crush tester, Bekk smoothness tester, folding endurance tester
-
Product
Environmental Chamber
REXMED REC-200
-
MOD. REC-200, AC 230/380/415V, 1/3 phase, Environmental chamber, HS CODE: 841989, UNCCS CODE: 484384, UMDNS CODE: 16327, Main construction: SS304, Interior: SS304, Exterior: SS304 powder coated, Insulation: Rigid polyurethane foam and glass wool, Controller: Fix point PID controller, temperature ˚C/PV and ˚C/SV, humidity %/PV and %/SV display and setting, Temperature range: -20˚C~100˚C, Humidity range: 20%RH~98%RH, Constancy: ±0.3˚C ±2.5%RH, Uniformity: ±1˚C ±3%RH, Temperature and humidity sensor: PT 100Ω, Temperature and humidity audio and visual warning and OFFS correction setting, Temperature heater: 1.5KW X 2pcs, Humidity heater: 2.5KW X 1pc, Heat up transition time: -20˚C~100˚C within 35 min, Refrigeration system: Air cooled, single stage, Cooling compressor: Bristol hermetic compressor, Cooling capacity: 1,892 Watts, 6,455 BTU/hr, 1,630 Kcal/hr, Cool down transition time: 20˚C~-20˚C within 45 min, Safety devices: No fuse breaker, refrigerator over load relay, refrigeration high pressure switch, over temperature protector, protection relay, protection fuse, water level control and overheat protector, Chamber: L50 X W60 X H75cm, Capacity: 225L, chamber with key lock, with lamp (DC 12V 50W) X 1pcs and double glass viewing window, testing cable port with cover: Ø25mm, 4 castors, W/S: shelf X 2pcs, standard testing wet cloth X 5pcs, PCV water container X 1pc
-
Product
FastBrake®
-
FastBrake® Electronic Air Brake is a microprocessor based, electro-pneumatic braking system. Designed for superior reliability, the system includes tightly integrated electronics and pneumatics, redundant electronics, dual channel power supply, and reduced part count. With over 4,100 systems installed globally, FastBrake® is service-proven and backed by Wabtec's global service and support network.
-
Product
CAPS Trace-Level NO2 Analyzer
Model T500U
-
Teledyne Advanced Pollution Instrumentation
The T500U CAPS NO2 Analyzer represents the next generation of criteria pollutant monitoring technology for the direct measurement of Nitrogen Dioxide (NO2) in air. The instrument utilizes a patented Cavity Attenuated Phase Shift (CAPS) technique to provide an extremely sensitive, fast and accurate NO2 measurement in a cost effective and low maintenance instrument package.The T500U provides a direct NO2 measurement, eliminating the need for catalytic conversion or reagents which introduce measurement artifacts inherent in traditional heated metal converter based chemiluminescense instruments. The CAPS measurement approach also reduces maintenance items, and removes the need for hazardous materials and high temperature scrubbers within the instrument. The T500U has an expected maintenance interval of one year under typical ambient monitoring conditions.
-
Product
Infrared Thermometer
MT-4612
-
Ideal for measuring of mechanical, chemical, pottery,food, metallurgy, electric power, air condition,high-temperature heat treatment.
-
Product
Zero Air System
Model T701
-
Teledyne Advanced Pollution Instrumentation
The T701 adds Modbus TCP/IP connectivity to the proven reliability and performance of our zero air systems. This allows remote monitoring of key instrument functions including dewpoint status, scrubber temperature, box temperature, and output pressure. Additionally, this digital access provides the ability to remotely disable the internal pump, allowing longer service intervals and less power consumption. The user can also remotely start instrument warm-up prior to arrival at the site.The T701 is a fully self-contained source of clean, dry air for dilution calibrators. It can also be used to create purge air for permeation tube ovens or burner air for FID analyzers. The T701 includes a dewpoint sensor, an oil and diaphragm-free pump, and scrubbers to remove SO2, NO, NO2, O3, H2S, and NH3. Optional high performance scrubbers are available to remove CO and Hydrocarbons.
-
Product
OEM Photoionization Sensors
-
As one of the most widely used gas detection techniques, the OEM Photoionization Detector (PID) is commonly applied in both portable and fixed instruments for detection of a wide variety of organic compounds and some inorganic gases in ambient air. Baseline PID monitors offer:
-
Product
Advanced Seismic Source
GI-SOURCE
-
Sercel developed the GI-SOURCE to reduce and suppress the bubble oscillation from a single impulsive source to simplify processing. The GI-SOURCE impulsive source is based on the same technology as the GI-SOURCE but is different in that it has two independent air chambers within the same casing : the Generator (generating the primary pulse and creating the main bubble) and the Injector (injecting air inside the main bubble so that it collapses quickly).
-
Product
Analytical Gear Inspection Machine for Workpieces Up to Ø 6,000 mm
KNM X series
-
machine structure with outstanding intrinsic accuracylarge bearing distances of guidesinherently stable granite machine base on active dampers to absorb vibrations ? no foundation requireddrive system close to center of gravitylinear motors in X-, Y-, Z- measuring axeshigh precision air- or hydrostatic bearing rotary tables (diameters from 500 to 1,800 mm) with direct drive and through holemotorized positioning of measuring column (V-axis) to the actual workpiece diameterlaser based system for safe operation
-
Product
Analogue (1kV below) Insulation Tester
2132 IN
-
Standard Electric Works Co., Ltd
● High quality Taut Band movement.● Three insulation test voltages(DC) : 250V, 500V, 1000V.● Two continuity test on low ohms : 3Ω & 500Ω.● Compact and lightweight.● 200mA continuity short circuit current.● 1mA test current on insulation test at nominal voltage.● Automatic discharge of capacitive and inductive circuit with charge stored in the circuit under test. ● Live warning and display or external voltage presence.● Fuse, air gap, crowbar and overload protected.● On line battery monitoring shows if battery is ok.● Manual zero ohm adjustment.● Low battery consumption.● Mirror scale.● Push and turn locking switch for continuous and hand free testing.● BS 16 edition.
-
Product
Non-contact Ultrasonic Testing System
-
Yamaha Fine Technologies Co., Ltd.
Contact-free inspection through ultrasonic transmission detecting air bubbles, separation, and foreign materials inside workpieces. With a Yamaha ultrasonic amplifier installed, contact-less inspection in the air is realized. Without damaging or wetting the workpiece, it is possible to inspect the workpiece for packing defects, air bubbles, and even flaw depth.
-
Product
Acoustic Imaging Solutions
-
Visualize the unheard and the unseen with the power of fixed acoustic imaging solutions from Fluke Process Instruments. Fixed acoustic imaging enables users to detect, locate and visualize air and gas leaks or changes in sound signatures across their process and equipment in real-time before they become costly problems.
-
Product
Acrylic Buttons
VAT810-TH/SD (VAT810-CO2)(VAT845
-
Shanghai Yi Hua V&A Instrument Co., Ltd. CO.,LTD
Desktop:Touch buttons : CO2 monitor Real-time monitoring of indoor air quality including CO2,temperature ,humudity and VOC.
-
Product
Anemometer-Thermometer
HD2303.0
-