Platinum
See Also: Precious Metal, Gold, Platinum RTD
-
Product
Platinum RTD Sensor - PT100 - 3 Wire 1 meter long
-
For precision temperature sensing, nothing beats a Platinum RTD. Resistance temperature detectors (RTDs) are temperature sensors that contain a resistor that changes resistance value as its temperature changes, basically a kind of thermistor. In this sensor, the resistor is actually a small strip of Platinum with a resistance of 100 ohms at 0C, thus the name PT100. Compared to most NTC/PTC thermistors, the PT type of RTD is much most stable and precise (but also more expensive) PT100's have been used for many years to measure temperature in laboratory and industrial processes, and have developed a reputation for accuracy (better than thermocouples), repeatability, and stability.
-
Product
RTD / PRT Platinum Sensing Resistor Inserts
-
RTD / PRT Platinum Sensing Resistor Inserts - Ceramic Sheathed, Pt100 & Pt1000 Inserts
-
Product
Platinum and Nickel RTD Temperature Sensors
-
Accurate, repeatable and robust resistance temperature detector (resistance thermometers) sensor assemblies manufactured provide fast temperature response and can be applied in most temperature measurement and control applications.
-
Product
Environmental Test Chamber
-
The chamber is produced by SUS304 Steel, the temperature keeping material is produced by Polyurethane hard foam and ultra-fine fibre glass, the doorframe heat insulated by Double high temperature aging silicone rubber door sealing strip.The temperature controller is used by Korean TEMI display in English/Chinese and German Siemens PLC, it can be communicated to PC via RS-232. The temperature accuracy is 0.1 and humidity is 0.1%R.HThe temperature sensor is platinum PT100 Ohms/MV resistor
-
Product
Tracking Index Test Apparatus
CX-L19
-
Shenzhen Chuangxin Instruments Co., Ltd.
It applied with rectangle size of platinum electrode, each electrode can force to the sample is 1.0±0.05N. Electrode Distance: 4.0mm±0.01mm, included angle: 60°±5°. Electrode Voltage: 100~600V, (48~60HZ) adjustable, when the short-circuit current at 1.0±0.1A, the voltage goes down less than 10%. The liquid drop device can make the liquid height from 30~40mm (adjustable), drops liquid size is 44~55 drops/1cm3. The interval drops of liquid is 30s±5s (adjustable). During the testing, the short-circuit current is more than 0.5A to keep 2 seconds, then shut off current, it show the sample not pass. Inside dimension: 0.5CBM and outside dimension: 630mm*390mm*750mm.
-
Product
RTD Thermometers
-
Precision Platinum Temperature Sensor, High Accuracy With 0.01°C Resolution, Automatic Locked Push-pull Connector For Easy Connection, Large Back Light LCD
-
Product
Ring Disk Electrode
-
This ring-disk type electrode developed by NTT Advanced Technology Corporation is a form of printed electrodes. Users can choose them from Carbon, Gold and Platinum applied versions. Available as a working electrode of radial flow cells, achieves complete reduction/oxidation on the center disk at ultra-low flow rate because of its fine coulometric electrolysis efficiency. This also enables to analyze subsequent reaction as well as identification and quantitation of the sample at the same time.
-
Product
8 Channels, RTD Measurement
RT1
-
The module provides 8 measurement channels, and can be programmed for interfacing to 2, 3, and 4-wire platinum RTD sensor configurations. The 4-wire mode (default) is the most accurate, providing excellent stability and repeatability. The RTD channels feature individual A/D converters and precision excitation/current drive. Programmable lead-wire compensation is provided for inherently less accurate 2 and 3-wire configurations. All RTD channels are self-aligning because each channel is automatically "aligned" on a rotating basis to eliminate offset and gain errors throughout the operating envelope. Programmability for expected resistance range and wire modes allows for optimization of scaling/resolution, as well as flexibility in reading many RTD types.
-
Product
Wireless Precision RTD Based Temperature Data Logger with LCD
RFRTDTemp2000A
-
The RFRTDTemp2000A is an RTD-based, wireless temperature data logger with display. This data logger is ideal for applications that require high accuracy temperature monitoring such as within laboratories, pharmaceutical and biotech industries. The RFRTDTemp2000A accepts 2, 3 or 4 wire 100Ω platinum RTD’s and features a device accuracy of +/-0.5°C.
-
Product
Diode Temperature Monitor
SIM922
-
Stanford Research Systems, Inc.
The SIM922 Diode Temperature Monitor and the SIM923 Platinum RTD Monitor are designed to measure four sensors simultaneously. Based on the modular SIM platform, they provide high-performance and multiple-channel capability in a small footprint.
-
Product
Force Tensiometers
Sigma 703D
-
Sigma 703D is a simple and robust digital force tensiometer for accurate measurement of surface and interfacial tension (Platinum Du Noüy ring, Platinum Wilhelmy Plate), and density. Manual measurement of Critical Micelle Concentration (CMC) can also be conducted.
-
Product
Multi-Function Recorder
Platinum 2.5K
-
For all types of power system events, the Platinum 2.5K Multi-Function Recorder provides all the information you need to capture the complete picture. This comprehensive fault recorder simultaneously performs transient, sequence of events and disturbance recordings, phasor measurements and power quality analysis. All of these functions are performed at the highest level so it will meet your needs of today and the future. In a deregulated environment, the Platinum 2.5K is the best tool to provide the necessary data to increase revenues and retain your customer.
-
Product
Galvanic DO Sensor
Model 20
-
The Model 20 Galvanic DO Sensor utilizes proven galvanic sensing technology – without a question the most accurate and reliable DO sensing technology ever developed. The pure platinum cathode makes the sensor incapable of being poisoned by other gases often found in impure waters, such as hydrogen sulfide. This sensor utilizes the only DO sensing technology that is successful in continuous de-nitrification monitoring and control applications. It is also the only sensor design that can be used continuously in very violent pure liquid oxygen injection systems. Complete systems are supplied with over 5 years of sensor electrolyte and membranes.
-
Product
Digital Melting Point Apparatus
DRK8011
-
Shandong Drick Instruments Co., Ltd.
DRK8011 Digital melting point apparatus is fully in line with ‘humanize’ of the design concept, using photoelectric automatic detection, dot matrix image LCD technology, digital keyboard input, each measuring one sample, measure three times the average of the melting point of the automatic strike, and has a melting, melting end automatically, melting curve automatic recording function. Temperature system uses high inearity make platinum resistance sensing element, the use of PID regulationtechnology to improve theaccuracy and reliability of the melting point, and with integrated electronic circuits to achieve rapid "starting temperature" setting and eight stalls to choose from linear "heating rate" Automatic Control. Instrument to establish communication with the PC via USB, save or print the graph, the instrument can be directly connected with the RS232 mini-printers, print graphs. The instrument uses Pharmacopoeia as a sample capillary tube.
-
Product
Conductivity Electrode
-
As current-carrying and potential difference measuring electrodes, platinum was deposited on a quartz glass substrate. Voltage terminal distance can be varied by changing the connection pin. In-situ measurement of the metal transition produced in a conductive polymer insulator doping, 4 terminal electrode is used, where for insulator layer with low doping side 2 terminal method and for metal layer with high doping side 4 terminal method is used for the measurement. With this electrode, become possible to have measurement in 15 distances by combining the connection terminal.
-
Product
Chilled Mirror Transmitter
DewTrak II
-
The DewTrak II uses the chilled mirror dew point temperature condensation principle to determine the water vapor concentration in gas mixtures, and a platinum resistance thermometer to accurately measure that temperature. Outputs include 4 to 20mA, 0 to 5 Vdc, or 0-10Vdc and an RS232 serial port as well as electrically isolated relay contacts.
-
Product
Particle Image Analyzer
DRK-7020
-
Shandong Drick Instruments Co., Ltd.
Determine the melting point to detect the purity of crystal material. Mainly used for determination of medicine, dyestuff, spice, and other crystal organic compounds’ melting point. Using photoelectric automatic detection, dot matrix image liquid crystal-display technology, and digital keyboard input. The instrument can measure three samples at the same time and has the initial melting, final weld automatic display, automatic recording of melting curve, automatically determine the melting point of the mean value function. The temperaturesystem uses highly linear platinum resistance as detection elements and PID regulation technology, improved the melting point’s precision and reliability. The instrument establishes communication with PC through the USB or RS232, printing or saving the curve and it uses capillary Pharmacopoeia as sample tube.
-
Product
Working Electrodes for Flow Cell
-
Our working electrodes for flow cell are mounted in blocks of PEEK. This resin protects the electrodes from external noise and allows researchers to utilize them regardless the content of mobile phase of HPLC because of their hardness and organic slovent-resistance. Glassy carbon is usually chosen for the redox reaction study on liquid chromatography. Platinum, Gold, Carbon paste and Nickel electrodes are utilized for special purporses.
-
Product
Dual MAX31865 PT-1000 RTD to Digital Breakout
SEN-30202-PT1K
-
Dual channel breakout board for the MAX31865 RTD-to-Digital converter from Maxim. Two breakout hardware configurations are available standard, designed to interface with either the PT100 or PT1000 platinum RTDs. For non-standard applications, including thermistors, custom hardware configurations can be accommodated. Contact Technical Support for more information.
-
Product
Force Tensiometers
Sigma 702
-
The Sigma 702 is a standalone force tensiometer that provides accurate surface and interfacial tension measurements (Platinum Du Noüy ring, Platinum Wilhelmy Plate), manual determination of Critical Micelle Concentration (CMC) and density measurements. The open design and convenient control keyboard operations make these instruments easy to use without the need for an external computer.
-
Product
Reference Thermapen®
-
Until now you would have spent hundreds more to get this level of accuracy in a NIST-Traceable standards thermometer. Our Reference Thermapen takes lab accuracy into the field. Each unit is factory calibrated at 5 test points and includes a UKAS accredited calibration certificate with test data. A true "system calibration" is performed matching its Platinum RTD sensor and the built-in electronics so all errors are included in the spec.
-
Product
Power Meters andCalibration Cells
-
The Solar Reference Cell consist of a 20 x 20 mm monocrystalline silicon Photovoltaic Cell encased in a 92 x 70 x 16 mm metal enclosure with a protective quartz window and a temperature sensor. The temperature sensor is a 100 ohm platinum Resistance Temperature Detector (RTD).The Solar Reference Cells come with a Certificate of Calibration and compatible set of connecting cables. The following parameters of the reference cell are certified: Isc, Imax, Voc, Vmax, Pmax, Area, Fill Factor and Efficiency. The certification is accredited by NIST to the ISO-17025 standard and is traceable both to the National Renewable Energy Laboratory (NREL), and to the International System of Units (SI). A compatible cable set is also supplied with each Solar Reference Cell.
-
Product
Grid Electrode
-
Grid electrode is produced by the deposition of the platinum, gold or carbon onto the quartz glass. The dimension of the glass is 8 x 27 mm, with a 1 mm of the thickness, and the grid line is 100 m width with a distance of the 150 m between lines.
-
Product
Salinity Testers
-
Labodam pocket salinity testers are equipped with platinum sensors, providing fast and reliable results measuring the salinity of water and other low and high salt concentrated solutions. Equipped with replaceable electrodes, helping to reduce maintenance cost.
-
Product
Dual MAX31865 PT-100 RTD to Digital Breakout
SEN-30202-PT100
-
Dual channel breakout board for the MAX31865 RTD-to-Digital converter from Maxim. Two breakout hardware configurations are available standard, designed to interface with either the PT100 or PT1000 platinum RTDs. For non-standard applications, including thermistors, custom hardware configurations can be accommodated. Contact Technical Support for more information. RTD devices may be wired in 2, 3 or 4-wire configurations using the 4-pin screw terminal input. The MAX31865 breakout is interfaced via 3 or 4-wire SPI with a data-ready output for specific operating modes. An LDO and a high-speed level shifter are included to allow interfacing with microcontroller devices between 3.0V and 5V (all Arduinos, Raspberry PI, etc) without sacrificing device performance.
-
Product
Reference Thermometers
-
Our Reference Thermapen takes lab accuracy into the field. Each unit is factory calibrated at 5 test points and includes a UKAS accredited calibration certificate with test data. A true "system calibration" is performed matching its Platinum RTD sensor and the built-in electronics so all errors are included in the spec.
-
Product
Gold Purity Tester
PRO‑ALLOY
-
The Easy Way To Test Gold & Platinum Jewelry. Measure the purity of rings, chains, watches and more… Instant gold karat reading • Fast and accurate • Non-destructive.
-
Product
Precision Thermometer
F252
-
ASL's F252 provides high accuracy, dual channel temperature measurement with Platinum Resistance Thermometers - PRTs - and uses AC bridge technology as developed by ASL for Standards Laboratories throughout the world. Model F252 requires no regular recalibration, the AC circuit techniques eliminating thermal EMFs and drift, while providing excellent long term stability. Front panel data entry allows you to enter probe calibration data into the F252's memory, so that thermometer resistance can be accurately converted to temperature in C, F or K. This can be password protected to prohibit unauthorised or accidental data entry.
-
Product
Low Constant Temperature Trough
DRK6691
-
Shandong Drick Instruments Co., Ltd.
Drk6691 small low constant temperature trough is a special product designed for small Abbe refractometer, supporting the use of. It has many advantages such as constant speed, constant temperature, small volume, low noise and convenient operation and so on , so it is a higher price products. This product adopts the technology of the one chip computer, PID selftuning regulation technology;adopts imported platinum resistance temperature (Pt100), so it has high precision of temperature control and temperature fluctuation is small; adopts the semiconductor refrigeration technology, so that it consists of advantages of fast refrigeration, no noise.
-
Product
Tone And Probe Kit
#TP150
-
Make cable tracing easy with Platinum Tools’ Tone and Probe Set. With its steady tone, push-to-scan button and a clear loudspeaker, quickly trace and identify cable locations on jacks or through walls. Wire bundles are easily penetrated with the tapered probe tip and the probe volume is controlled with a thumbwheel. With common send and […]