Product
PXIe 10GBase-T1 Ethernet MEMS Fault Insertion Switch, 8 Channel
42-205-008
Fault Insertion Unit
42-205-008 (PXIe) is a 8-channel fault insertion switches designed to simulate common faults on high speed two wire communication interfaces such as xBaseT1 Ethernet. They available with 4 or 8 channels of two wire serial connections and can be used for simulating faults on 10BaseT1, 100BaseT1, 1000BaseT1 and 10GBaseT1 Ethernet interfaces. Any wire can be set as open circuit and shorts can be applied across wire pairs. Fault connections can be made to one of four external signals via two fault buses, typically simulating connections to supply voltage or ground.
-
Product
PXI Source Measure Unit
Source Measure Unit
PXI Source Measure Units (SMUs) combine high-precision source and measure capability with features designed to reduce test time and increase flexibility. These features include high channel density for building parallel SMU test systems, deterministic hardware sequencing for minimizing software overhead, and high-speed update and sample rates for quickly changing setpoints and acquiring data. Additionally, the flexible sampling rate and streaming capability of PXI SMUs allows you to use the instrument as a digitizer to capture transient behavior, and the digital control loop gives you the ability to adjust the transient response of the instrument. The ability to change the transient behavior of the SMU, called SourceAdapt, reduces SMU settling time and minimizes overshoot and oscillations, even with highly capacitive loads.
-
Product
PXI 10A Fault Insertion Switch 10-Chan 1-Bus
40-199-001
Fault Insertion Unit
The 40-199 is a 10 Channel Fault Insertion switch designed for the simulation of fault conditions in automotive/avionics applications, involving the reliability testing of safety critical controllers.
-
Product
High-Density Precision SMU (10 PA, 30 V)
PZ2131A
Source Measure Unit
The Keysight PZ2131A is a high-channel density precision source / measure unit (SMU) having 5 channels per module and saving space for a wide range of applications requiring numerous precision power supplies. The narrow-pulse function and fast Digitizer Mode allow the PZ2131A to expand the conventional static DC measurements to emerging dynamic measurements. Its seamless current measurement ranging function eliminates the time it takes to change the range and expands the dynamic range to cover multiple measurement ranges, which reduces test duration. These capabilities make the PZ2131A suitable for applications that require numerous precision power supplies, such as semiconductor reliability tests and integrated circuit (IC) tests. The Keysight PX0107A low noise filter adapter lowers its voltage source noise level, which makes the PZ2131A suitable for noise-sensitive applications such as quantum computing as well.
-
Product
PXI-2510, 68-Channel, 2 A PXI Signal Insertion Switch Module
778572-10
Fault Insertion Unit
68-Channel, 2 A PXI Signal Insertion Switch Module—The PXI‑2510 fault insertion unit (FIU) is designed for hardware‑in‑the‑loop (HIL) applications and electronic reliability tests. Each module has a set of feedthrough channels that you can open or short to one or more fault buses. You can use this architecture to simulate open or interrupted connections as well as shorts between pins, shorts to battery voltages, and shorts to ground on a per-channel basis. When controlled with the LabVIEW Real-Time Module, the PXI‑2510 is ideal for validating the integrity of control systems including engine control units (ECUs) and full authority digital engine controls
-
Product
PXI 10GBase-T1 Ethernet MEMS Fault Insertion Switch, 8 Channel
40-205-008
Fault Insertion Unit
The 40-205-008 (PXI) is a 8-channel fault insertion switches designed to simulate common faults on high speed two wire communication interfaces such as xBaseT1 Ethernet. They available with 4 or 8 channels of two wire serial connections and can be used for simulating faults on 10BaseT1, 100BaseT1, 1000BaseT1 and 10GBaseT1 Ethernet interfaces. Any wire can be set as open circuit and shorts can be applied across wire pairs. Fault connections can be made to one of four external signals via two fault buses, typically simulating connections to supply voltage or ground.
-
Product
PXIe-4143, 4-Channel, ±24 V, 150 mA Precision PXI Source Measure Unit
782431-01
Source Measure Unit
PXIe, 4-Channel, ±24 V, 150 mA Precision PXI Source Measure Unit - The PXIe-4143 is a 4-channel source measure unit (SMU) ideal for high-pin-count applications. It features 4-quadrant operation and each channel has integrated remote (4-wire) sensing for accurate measurements. The fast sample rate of the PXIe-4143 can reduce measurement times, capture transient device characteristics, and allow quick I V characterization of devices under test (DUTs). With a high-speed sequencing engine, you can synchronize all these SMUs with each other or with other instruments such as switches or high-speed digital test modules. Additionally, you can tune the PXIe-4143 response to any load to achieve optimum responses with maximum stability and minimum transients using SourceAdapt technology.
-
Product
PXI/PXIe Source Measure Unit Family
PXS(e)840x
Source Measure Unit
The PXS840x PXI SMU family is a high-speed, 4-quadrant source measure unit. Carry out measurements directly on the DUT with the integrated CMU and VMU.
-
Product
Precision Source / Measure Unit (2 Ch, 100 FA)
B2902B
Source Measure Unit
The Keysight B2902B precision source / measure unit (SMU) is a 2-channel, compact, and cost-effective benchtop SMU with the capability to source and measure both voltage and current. It easily measures current versus voltage (I/V) with high accuracy. The 4-quadrant source and measurement capabilities enable taking I/V measurements without configuring multiple instruments.
-
Product
PXI Single Bus 32-Ch 2A Fault Insertion Switch, N/O Through Relays
40-190B-501
Fault Insertion Unit
The Single Bus, 32 Channel PXI Fault Insertion switch is part of our family of 2 Amp fault insertion solutions, The range includes modules with 74, 64 or 32 channels and single or dual fault buses. This version has normally open through relays, so in the default state, there are no paths between inputs and outputs for any signal channel. It is primarily designed for the simulation of fault conditions in automotive & avionics applications involving the reliability testing of safety critical controllers.
-
Product
PXIe Precision Source/Measure Unit, 1.25 MSa/s, 10 fA, 210 V, 315 mA
M9601A
Source Measure Unit
M9601A PXIe precision SMU is the industry-first precision PXIe SMU enabling faster precise measurement from DC to 20 μs pulse up to 210 V/315 mA with the best-in-class 10 fA resolution and low noise.
-
Product
PXIe-4139 , ±60 V, ±3 A DC, ±10 A Pulsed, 40 W DC, 100 fA Precision System PXI Source Measure Unit
782856-03
Source Measure Unit
PXIe, ±60 V, ±3 A DC, ±10 A Pulsed, 40 W DC, 100 fA Precision System PXI Source Measure Unit - The PXIe-4139 is a high-precision, system source measure unit (SMU) that features 4-quadrant operation and sources up to 40 W of DC power. This module features analog-to-digital converters that help you perform high-precision measurements with a current resolution of 100 fA or high-speed acquisitions up to 1.8 MS/s. The module can maximize stability and measurement accuracy with SourceAdapt technology, which you can use to tune the transient response to match the characteristics of any load. You can use the PXIe-4139 for applications including manufacturing test, board-level test, and lab characterization with devices such as ICs, power management ICs (PMICs), and RFICs and discrete devices including LEDs and optical transceivers.
-
Product
PXI/PXIe 1000Base-T1 Fault Insertion Switch, 3-Channel
42-203-001
Fault Insertion Unit
The 40-203-001 (PXI) and 42-203-001 (PXIe) are designed to simulate common faults on high-speed two wire communication interfaces such as 1000Base-T1. They support 3 channels of two wire serial interfaces. Each channel pair can simulate an open fault in either or both wires, and using the fault bus switches can simulate short between both wires or a short to one of two externally applied fault connections – such as battery supply or ground - via two fault buses.
-
Product
High-Speed Precision SMU (100 FA, 60 V, 15 MSa/s)
PZ2121A
Source Measure Unit
The Keysight PZ2121A is a high-speed precision source / measure unit (SMU) featuring best-in-industry narrow-pulse width, fast Digitizer Mode, and seamless current measurement ranging. It enables narrow-pulsed measurements and fast dynamic measurements with a wide dynamic range for a wide range of emerging applications such as vertical-cavity surface-emitting laser (VCSEL) optical devices, integrated circuit (IC) testing. In addition, its low measurement noise performance enables measurements with shorter aperture times, and its seamless current measurement ranging function enables a wide dynamic range and eliminates range change time, which improves test throughput.
-
Product
Ethernet/AFDX/BroadR-Reach PCI Fault Insertion Switch - 8 Channel
50-201-008
Fault Insertion Unit
This high bandwidth differential PCI fault insertion card is designed to simulate common faults on high speed two wire communication interfaces such as Ethernet. This card supports 4 or 8-channels of two wire serial connections and can be used for simulating faults on Ethernet, AFDX, BroadR-Reach, 100BaseT and 1000BaseT interfaces. Any wire can be set to an open circuit, shorts can be applied across the wire pair, or to the adjacent pair. Fault connections can be made to one of four external signals via two fault buses, typically simulating connections to a supply voltage or ground.
-
Product
PXI 11-Channel 2A Fault Insert Switch
40-202-101
Fault Insertion Unit
This is the 11 Channel version of the 40-202 Fault Insertion Switch. It is primarily designed for the simulation of fault conditions in automotive & avionics applications involving the reliability testing of safety critical controllers. It is designed to be able to insert three different fault conditions between the test fixture and the equipment under test
-
Product
PXI 10GBase-T1 Ethernet MEMS Fault Insertion Switch, 8 Channel
40-205-008
Fault Insertion Unit
The 40-205-008 (PXI) is an 8-channel fault insertion switch designed to simulate common faults on high speed two wire communication interfaces such as xBaseT1 Ethernet. It is available with 4 or 8 channels of two wire serial connections and can be used for simulating faults on 10BaseT1, 100BaseT1, 1000BaseT1 and 10GBaseT1 Ethernet interfaces. Any wire can be set as open circuit and shorts can be applied across wire pairs. Fault connections can be made to one of four external signals via two fault buses, typically simulating connections to supply voltage or ground.
-
Product
PXI 30A Fault Insertion Switch 6-chan 2-bus
40-191-012
Fault Insertion Unit
The 40-191-012 is a PXI fault insertion switch using solid state switching elements and is capable of carrying 40A on single channel or 30A on all channels at the same time and provides a robust solution to high current fault insertion.
-
Product
Source Measurement Unit
PEMU4
Source Measure Unit
The PEMU4 represents a new level of performance and capabilities for USB-based SMU (Source MeasurementUnit) instrumentation. The PEMU4 supports -1V to +6.5V 0.5A with FVMI, FVMV, FIMV, FIMI modes. 4 channel can be ganged to support high current driving. I2C/SPI/RFFE function for serial port device testing. 4 Counter for frequency measurement.
-
Product
PXI Dual Bus 64-Chan 2A Fault Insertion Switch
40-190B-102
Fault Insertion Unit
The Dual Bus, 64 Channel PXI Fault Insertion switch is part of our family of 2 Amp fault insertion solutions, The range includes modules with 74, 64 or 32 channels and single or dual fault buses. This version has normally closed through relays, so in the default state, there is a path between input and output for all signal channels. It is primarily designed for the simulation of fault conditions in automotive & avionics applications involving the reliability testing of safety critical controllers.
-
Product
6x 3U OpenVPX MOSA Data Concentrator Unit
SIU36-DCUVARM-01
Data Concentrator Unit
SIU36-DCUVARM-01 is a Modular Open Systems Approach (MOSA) DO-178C & DO-254 Certifiable Data Concentrator Unit (DCU) with low power high performance OpenVPX Xilinx UltraScale+ SBC with Quad Core ARM Cortex -A53, 8 GB DDR4 SDRAM, 32 GB SATA Flash, 2 x 10/100/1000Base-T Ethernet, USB 3.0, FIPS-140-3 Level 3 Cyber Security, and Single Event Upset support.
-
Product
PXI Isolated Single Channel Voltage/Current Source, 100V
M9186A
Source Measure Unit
The V/I source lets you source a voltage and measure the resultant current, or source a current and measure the resultant voltage. It consist of two separate amplifiers, denoted "low" and "high" that share a common output connection. The "low" amplifier provides voltages in the range of 16 volts at up to 200ma and the "high" amplifier provides voltages in the range of 100V at up to 20mA.
-
Product
Ethernet/AFDX/BroadR-Reach PCI Fault Insertion Switch - 4 Channel
50-201-004
Fault Insertion Unit
This high bandwidth differential PCI fault insertion card is designed to simulate common faults on high speed two wire communication interfaces such as Ethernet. This card supports 4 or 8-channels of two wire serial connections and can be used for simulating faults on Ethernet, AFDX, Broad R-Reach, 100BaseT and 1000BaseT interfaces. Any wire can be set to an open circuit, shorts can be applied across the wire pair, or to the adjacent pair. Fault connections can be made to one of four external signals via two fault buses, typically simulating connections to a supply voltage or ground.
-
Product
Source/Measure Unit for Functional Test, Multiple Ranges, 80 W, Double-wide
N6786A
Source Measure Unit
Only Keysight`s N6780 Series SMUs let you visualize current drain from nA to A in one pass and one picture unlocking insights to deliver exceptional battery life.
-
Product
PXI 10A Fault Insertion Switch 10-Chan 2-Bus
40-199-002
Fault Insertion Unit
The 40-199 is a 10 Channel Fault Insertion switch designed for the simulation of fault conditions in automotive/avionics applications, involving the reliability testing of safety critical controllers.
-
Product
Dual Function Slot MOSA Data Concentrator Unit (DCU)
NIU2A-DCU-01
Data Concentrator Unit
NIU2A-DCU-01 is a Modular Open Systems Approach (MOSA) Data Concentrator Unit with low power high performance ARM Cortex -A9 processing. 512 MB RAM, 32 GB SATA Flash, 2 x 10/100/1000Base-T Ethernet and optional Fiber Optic Ethernet support
-
Product
PXIe-4137, ±200 V, ±1 A DC, ±3 A Pulsed, Up to 40 W DC, 100 fA Precision System PXI Source Measure Unit
783761-01
Source Measure Unit
PXIe, ±200 V, ±1 A DC, ±3 A Pulsed, Up to 40 W DC, 100 fA Precision System PXI Source Measure Unit - The PXIe-4137 is a high-precision, system source measure unit (SMU). It features 4-quadrant operation and sources up to 40 W of DC power and can pulse up to 500 W. Analog-to-digital converter technology helps you perform high-precision measurements with a current resolution of 100 fA or high-speed acquisitions up to 1.8 MS/s. The module also can maximize stability and measurement accuracy with SourceAdapt technology, which you can use to tune the transient response to match the characteristics of any load. The PXIe-4137 is ideal for a broad range of applications including manufacturing test, board-level test, and lab characterization with devices such as ICs, power management ICs (PMICs), and RFICs and discrete devices including LEDs and optical transceivers.
-
Product
Ethernet/AFDX/BroadR-Reach PXI Fault Insertion Switch - 8 Channel
40-201-008
Fault Insertion Unit
This high bandwidth differential PXI fault insertion module is designed to simulate common faults on high speed two wire communication interfaces such as Ethernet. This module supports 4 or 8-channels of two wire serial connections and can be used for simulating faults on Ethernet, AFDX, BroadR-Reach, 100BaseT and 1000BaseT interfaces. Any wire can be set to an open circuit, shorts can be applied across the wire pair, or to the adjacent pair. Fault connections can be made to one of four external signals via two fault buses, typically simulating connections to a supply voltage or ground. Each fault bus is capable of carrying 2A allowing multiple channels to be connected to the same fault condition. Additionally, each fault bus features a changeover relay to allow the user to connect alternative fault conditions to the fault buses.
-
Product
PXIe 5-channel Source/Measure Unit, 500 kSa/s, 100 pA, 30 V, 500 mA
M9614A
Source Measure Unit
The Keysight M9614A is a PXIe five-channel source / measure unit (SMU). It supports accurate measurement up to 30 V / 500 mA with resolution down to 6 μV / 100 pA.
-
Product
PXIe-4140, 4-Channel Source Measure Unit
781742-01
Source Measure Unit
The PXIe-4140 is a 4-channel source measure unit (SMU) ideal for high-pin-count applications. It features 4-quadrant operation, and each channel has integrated remote (4-wire) sensing for accurate measurements. The fast sample rate of the PXIe-4140 can reduce measurement times, capture transient device characteristics, and allow quick I V characterization of devices under test (DUTs). With a high-speed sequencing engine, you can synchronize all these SMUs with each other or with other instruments such as switches or high-speed digital test modules.