Precision Current Sources
-
Product
Precision High Current Resistors/Shunts
-
Measurements International Ltd.
The precision high current shunts are a series of High Current Resistors ranging from 1 A to 3000 A with optional air moving fans and resistance values from ohms to micro-ohm.
-
Product
NI-9266 , 8-Channel C Series Current Output Module
785046-01
-
8-Channel C Series Current Output Module - The NI‑9266 is ideal for interfacing and controlling industrial current-driven actuators. The module has built-in open-loop detection, which generates an interrupt in software when an open loop is detected as well as zeroing outputs to ensure safety and avoid driving actuators at system power on. The NI‑9266 includes channel‑to‑earth ground isolation for safety and noise immunity.
-
Product
NI-9253, 50 kS/s/ch, ±20 mA, 24-Bit, 8-Channel C Series Current Input Module
785989-01
-
50 kS/s/ch, ±20 mA, 24-Bit, 8-Channel C Series Current Input Module - The NI-9253 is an 8-channel analog input module for ComapctDAQ and CompactRIO systems. Each channel provides a ±20 mA input range and 24 bits of resolution at a 50 kS/s sample rate. The NI-9253 has several diagnostic features to ensure your system is operating nominally at all times with open channel detection, power supply detection, and configurable thresholds. The NI-9253 has eight LEDs to indicate the status of each channel and the power supply so that a user in the field can easily validate that the system is operating normally. The NI-9253 also features a number of programmable hardware filters. By choosing the specific Butterworth and comb filters for your application, you can significantly reduce the noise in your system.
-
Product
Multi-Channel, Programmable Current Source
CS-48-100
-
The Model CS-48-100 is a multi-channel, programmable current source. Developed for both semiconductor and digital superconductor electronics, it is computer-controlled and features 48 low noise current source outputs. Each source output has the capability to both set and read back currents and can be set to a zero current high Z mute state. Each of the 48 sources are optically coupled for control and are sourced from their own secondary winding for complete galvanic isolation. The device consumes a maximum of only 80 W and handles a maximum load current of 4.8 A total over all outputs. Operating over a range of 0-100 mA on each channel, the device features accuracy of +/-25 ?A. The mute state can be set thru a rear panel interlock or from the front panel button for maximum circuit protection. The unit can be mounted in a standard-sized rack.
-
Product
Standard - 1.44 (41.00) - 4.50 (128.00) High Current Probe
HCP-13P
-
Current Rating (Amps): 15Average Probe Resistance (mOhm): 25Test Center (mil): 125Test Center (mm): 3.18Full Travel (mil): 250Full Travel (mm): 6.35Recommended Travel (mil): 167Recommended Travel (mm): 4.24Mechanical Life (no of cyles): 250,000Overall Length (mil): 1,300Overall Length (mm): 33.02
-
Product
NI-9247, 50 kS/s/ch, 50 Arms, 147 Apk, 24-Bit, 3-Channel C Series Current Input Module
783589-01
-
50 kS/s/ch, 50 Arms, 147 Apk, 24-Bit, 3-Channel C Series Current Input Module - The NI‑9247 is designed to support direct ring lug connectivity to the three-phase high-current measurements of 1 A and 5 A current transformers (CTs). It is optimized for power, energy, and industrial applications. The safety features, certifications, input ranges, overvoltage ranges, and connectivity are well suited for applications such as power quality monitoring and metering, utility pole-mounted smart switches, utility pole-mounted smart grid reclosers, substation merging units, industrial machine measurements, health monitoring, predictive maintenance and prognostics, and phasor measurement units (PMUs).
-
Product
NI-9208, 500 S/s, ±20 mA, 16-Channel C Series Current Input Module
780968-01
-
500 S/s, ±20 mA, 16-Channel C Series Current Input Module - The NI‑9208 is designed with industrial systems in mind. It includes a high-resolution mode with 50/60 Hz rejection to remove low frequency noise. It has high-channel density to reduce the number of modules needed, which leaves slots open for other measurement types or for reducing the overall per channel cost of the system. The NI‑9208 uses a standard D‑SUB connection for use with cables and connector blocks.
-
Product
High-Density Precision SMU (10 PA, 30 V)
PZ2131A
-
The Keysight PZ2131A is a high-channel density precision source / measure unit (SMU) having 5 channels per module and saving space for a wide range of applications requiring numerous precision power supplies. The narrow-pulse function and fast Digitizer Mode allow the PZ2131A to expand the conventional static DC measurements to emerging dynamic measurements. Its seamless current measurement ranging function eliminates the time it takes to change the range and expands the dynamic range to cover multiple measurement ranges, which reduces test duration. These capabilities make the PZ2131A suitable for applications that require numerous precision power supplies, such as semiconductor reliability tests and integrated circuit (IC) tests. The Keysight PX0107A low noise filter adapter lowers its voltage source noise level, which makes the PZ2131A suitable for noise-sensitive applications such as quantum computing as well.
-
Product
PXI/PXIe High Density Precision Resistor Module
42-297A-052
-
The 40-297A-052 (PXI) and the 42-297A-052 (PXIe) are 6-channel programmable resistors with a range of 3 Ω to 5.82 MΩ. They are part of the 40/42-297A series of high density precision resistor modules and provide a simple solution for applications requiring accurate simulation of resistive sensors.
-
Product
Source Measure Units (SMUs)
B1511B
-
The SMUs of B1500A integrate 4-quadrant voltage/current source and measurement capabilities for accurate IV measurement with the range of 0.1 fA - 1 A / 0.5 µV - 200 V. It supports spot, sweep, pulse sampling and QS-CV measurements.
-
Product
Precision Calibrated Noise Sources
-
ELVA-1's calibrated noise source ISSN-XX series delivers a uniform level of noise power spectral density within the whole waveguide frequency range. Sources are available in eight waveguide bands covering 26.4-170 GHz.
-
Product
Brute High Current Probe
P4301-1W
-
Current Rating (Amps): 50Current Rating Remark: 40 Amps for BeCu plungersAverage Probe Resistance (mOhm): 5Test Center (mil): 300Test Center (mm): 7.62Full Travel (mil): 250Full Travel (mm): 6.35Recommended Travel (mil): 167Recommended Travel (mm): 4.24Mechanical Life (no of cyles): 1,000,000Overall Length (mil): 1,750Overall Length (mm): 44.45
-
Product
Precision Multi-Channel DC Source PXI Card
GX1838 Series
-
The GX1838 is a multi-channel programmable DC Source providing multiple discrete outputs for avionics automotive, industrial testing and other ATE applications.
-
Product
Current & Voltage Sources for Calibration of Measuring Systems and Sensors
-
ChenYang Technologies GmbH & Co. KG
*DC/AC Current: 0-60A *DC/AC voltage: 0-1000V frequency 50Hz, 60Hz, 400Hz, 1kHz
-
Product
10-Ch. 0… 5V 400mA Isolated
YAVAP955
-
The YAV board AP955 contents 10 CAN Bus programmable bipolar Isolated precision and low noise 0 to 5VDC voltage sources up to 400mA output, with Tripaddle VPC connector.
-
Product
PXI/PXIe High Density Precision Resistor Module, 9-Channel
40-297A-035
-
The 40-297A-035 (PXI) and the 42-297A-035 (PXIe) are 9-channel programmable resistors with a range of 2 Ω to 102 kΩ. They are part of the 40/42-297A series of high density precision resistor modules and provide a simple solution for applications requiring accurate simulation of resistive sensors.
-
Product
Precision Source / Measure Units (SMU)
B2900 Series
-
The Keysight B2900 Series precision source measure unit (SMU) provides superior performance and usability at a reasonable price. These compact benchtop SMUs enable you to quickly take various I-V (current versus voltage) measurements requiring high resolution and accuracy. Easily view results on the user-friendly, color LCD graphic interface without changing connections.
-
Product
16-Channel VME Current Source & Analog Measurement Module
V460
-
The V460 is a VME-based versatile source/measurement unit. It includes a programmable constant-current source, a precision programmable gain 16-bit analog-to-digital converter, and a 4-wire, 16-channel analog multiplexer. An internal microprocessor supervises channel scanning according to user loaded parameters, reporting sensor voltage drops or, for selected sensor types, engineering-unit data.
-
Product
SpikeSafe DC Current Sources
-
The Vektrex SpikeSafe DC Current Sources provide reliable drive for LED/laser diode reliability, IESNA LM-80 test, and other current-driven test applications. Models support currents from 500mA to 60A and compliance voltages from 50V to 400V. All models feature individual channel control, precise current, and high power density — typically 6.4kW-8kW.
-
Product
NI-9208, 500 S/s, ±20 mA, 16-Channel C Series Current Input Module
785041-01
-
500 S/s, ±20 mA, 16-Channel C Series Current Input Module - The NI‑9208 is designed with industrial systems in mind. It includes a high-resolution mode with 50/60 Hz rejection to remove low frequency noise. It has high-channel density to reduce the number of modules needed, which leaves slots open for other measurement types or for reducing the overall per channel cost of the system. The NI‑9208 uses a standard D‑SUB connection for use with cables and connector blocks.
-
Product
PXIe-4138, 60 V, 3 A System PXI Source Measure Unit
782856-01
-
±60 V, 3 A System PXI Source Measure Unit—The PXIe‑4138 system source measure unit (SMU) delivers high power, precision, and speed. It is ideal for a broad range of applications including manufacturing test; board-level test; lab characterization with devices such as integrated circuits (ICs), power management integrated circuits (PMICs), and radio frequency integrated circuits (RFICs); and discrete devices including LEDs and optical transceivers. The PXIe‑4138 features 4-quadrant operation. The PXIe‑4138 is a hardware-timed instrument with a high-speed sequencing engine for synchronizing acquisitions between multiple SMUs. The module supports direct DMA streaming between the host PC and SMU, so you can stream large waveforms and measurement data at the full update rate and sample rate of the instrument.
-
Product
Tunable Laser Source - MATRIQ
-
The Laser 1000 Series is a fully-compliant micro-ITLA laser with up to four channels in a compact benchtop form factor.Offering 0.01 pm resolution tunability across C or L bands, exceptional power accuracy up to 16.5dBm, and optional dither suppression, this is a versatile and cost-effective general purpose instrument.
-
Product
Precision Current Shunt
-
Has five precision selectable Ultra stable Current Shunts which ranges from 0.0001 to 1Ω. The Shunt T/C is less than 10ppm, and the internal current meter will measure from 1μA to 1000Amps.
-
Product
High Power Precision Current Sensing Resistors
HPCR4T
-
High Power Precision Current Sensing Resistors of HPCR4T designed with four terminals, are distinguished by excellent long term stability & TCR. The Kelvin connections of this device allow for high precision measurements even with low resistance values. HPCR 4T has a non-inductive copper manganin element inserted into the ceramic case and finally sealed with a cement molding.
-
Product
PXI/PXIe High Density Precision Resistor Module
42-297A-030
-
The 40-297A-030 (PXI) and the 42-297A-030 (PXIe) are 9-channel programmable resistors with a range of 2 Ω to 6.97 kΩ. They are part of the 40/42-297A series of high density precision resistor modules and provide a simple solution for applications requiring accurate simulation of resistive sensors.
-
Product
Blackbody Sources
Hyperion R Model 982
-
The Hyperion R Calibration Bath comprises a blackbody cavity for calibration of infrared thermometers. An important factor is that its operation range includes ambient temperature, which is a difficult radiation point to achieve.
-
Product
Omnidirectional Source
BAS001
-
The BAS001 Source is designed to generate omnidirectional sound fields for making standard compliant measurements including: reverberation time (ISO 3382, ASTM E2235), building acoustics (insertion loss, acoustic absorption area, etc: ISO 140-4 ISO 140-3, ASTM E336, ASTM E90, DIN 55 210). The BAS001 is typically used to saturate a room with a uniform acoustic field. The available high-efficiency power amplifier has no fan for cooling, allowing measurements in quiet environments, like those in reverberation time applications.
-
Product
PXIe 5-channel Source/Measure Unit, 500 kSa/s, 100 pA, 30 V, 500 mA
M9614A
-
The Keysight M9614A is a PXIe five-channel source / measure unit (SMU). It supports accurate measurement up to 30 V / 500 mA with resolution down to 6 μV / 100 pA.
-
Product
Precision Current Preamplifier
SIM918
-
Stanford Research Systems, Inc.
The SIM918 Current Preamplifier is ideal in applications in which the input offset voltage must be kept to a minimum. The DC voltage difference between the two inputs (current input and voltage bias) is accurately measured every 2 seconds, and is nulled.