-
Product
Measurement System for ESD Protection
SampleProtect
-
The SampleProtect measurement system is ready to go, and comes complete with Oxford Instruments’ Cryofree bottom loading cryostat – the OptistatDry BLV, Zurich Instruments’ MFLI Lock-in Amplifier, a specially designed ESD break-out box and high quality measurement grade cables. The patent-pending puck style mounting from Oxford Instruments provides safe installation of your samples. The MFLI 500 kHz Lock-in Amplifier (capable of 500 kHz demodulation as standard) with MF-MD multi-demodulator capability brings the benefits of high performance signal processing at low and medium frequencies. The differential voltage and current inputs of the MFLI are optimised for low noise operation and the high oversampling rate ensures an even better signal to noise ratio. Zurich Instruments’ unique LabOne® control software provides a toolset including an integrated oscilloscope, a spectrum analyser, a plotter and a parameter sweeper.
-
Product
T3DSO Passive Probe, 350 MHz, 10X, 10 MOhm, 300V/600V
T3PP350A
-
Passive probes are the standard probe provided with most oscilloscopes. Typical passive probes provide a 10:1 attenuation and feature a high input resistance of 10 MΩ. This high input resistance means that passive probes are the ideal tool for low frequency signals since circuit loading at these frequencies is minimized. Passive probes are designed to handle voltages of at least 400V, some as high as 600V. Teledyne LeCroy passive probes feature an attenuation sense pin which tells the oscilloscope to scale the waveforms automatically requiring no user input.
-
Product
Broadband Marine Source
TPS™
-
TPS™ (Tuned Pulsed Source) is a new marine seismic source that provides geophysical clarity by improving low frequency (content while) also supporting important environmental benefits.
-
Product
NLFA Notch
-
The NLFA is a multiple element device allowing several useful field configurations. The three internal elements,one low frequency amplifier, two notch amplifier each with the cut off freq. of 50Hz (or 60Hz for a specific version) can be used as independent ones or combined together to increase the notch function. The effect of the cascade of two notches is the increasing of the signal attenuation for the notch frequency.
-
Product
High-speed Dual-channel 2D GPR
CrossOver
-
First dual-channel RTS (Real-Time Sampling technology) antenna. The dual-channel configuration provides you with both low and high frequency bands in one package, making it possible to cover a broad range of applications with only one instrument. RTS-based GPR antenna designs have already proven their effectiveness against conventional designs in relation to performance improvements (increased dynamic range, sensitivity, and depth penetration).
-
Product
Compact Low-Frequency Control Element
900-LFC
-
The 900-LFC Low-Frequency Control Element extends the response of mid-sized P.A. systems to 35 Hz, revealing the nuances of your mix, down to the deepest bass with total accuracy.
-
Product
500 MHz Passive Probe for WaveJet Touch, 10:1, 10 MOhm
PP006D
-
Passive probes are the standard probe provided with most oscilloscopes. Typical passive probes provide a 10:1 attenuation and feature a high input resistance of 10 MΩ. This high input resistance means that passive probes are the ideal tool for low frequency signals since circuit loading at these frequencies is minimized. Passive probes are designed to handle voltages of at least 400V, some as high as 600V. Teledyne LeCroy passive probes feature an attenuation sense pin which tells the oscilloscope to scale the waveforms automatically requiring no user input.
-
Product
Handheld spectrum analyzer/Signal analyzer
-
Recently, a lot of equipment have taken the high frequency or microwave technology according to the advancement and the spread of the telecommunication equipment. As a result, the handheld spectrum analyzer to analyze the signal by the frequency domain is necessaries now. The handheld spectrum analyzer is roughly classified into a heterodyne method and a Fourier transform method. The heterodyne method is also called the swept frequency method and makes it possible to measure up to tens of GHz though only for the steady signal. On the other hand, the Fourier transform method is also called the real time method and can handle an unsteady signal though the low measuring frequency range up to tens of MHz. As for our spectrum analyzer or signal analyzer, the MSA300/400 series adopts the swept frequency method, and the MSA500 series adopts both the swept frequency method and the Fourier transform method.
-
Product
Frequency Up Converters
-
Are integrated assemblies that convert low frequency RF signals to higher frequency RF signals.
-
Product
Materials Lab XM
-
The Materials Lab XM product provides a fully integrated reference grade time domain and AC measurement platform. No need to switch sample connections between techniques. Time domain measurements include I-V (current voltage) characterization as well as fast pulse techniques. AC testing techniques include everything from single-sine analysis, to multisine / Fast Fourier Transform for faster low frequency analysis, to harmonics and intermodulation for testing linearity and breakdown of materials. Measurements of electrical impedance spectroscopy (EIS), admittance, permittivity and capacitance are all provided from the XM-studio MTS software platform, together with integrated equivalent circuit analysis functionality.
-
Product
Test Board For SFP+ / SFP28 Transceiver
ESFP280
-
The OPTELLENT ESFP280 is a cost-effective and convenient test board for testing SFP/SFP+/SFP28 optical transceivers in R&D and manufacturing environments. The ESFP280 is equipped with high quality RF connectors for data signals and test points for low frequency control and status signals. The ESFP280 is equipped with power supplies to enable voltage margining. Key status signals are displayed using LED indicators.
-
Product
Full Band Scalar Network Analyzer Extenders
-
Full band scalar network analyzer extenders are designed to extend low frequency scalar network analyzers to higher millimeterwave frequency ranges. These extenders offer a low cost means of producing millimeterwave scalar network analyzers while preserving the functionality and features that industry standard models offer. These extenders deliver a superior performance since they are assembled with SAGE Millimeter’s instrumentation grade frequency extenders (STE series), Faraday isolators (STF series), direct or programmable attenuators (STA series), directional couplers (SWD series) and waveguide detectors (STD series). The below standard offering covers the frequency range of 26.5 to 170 GHz. Specifications other than those listed below are available upon request.
-
Product
Acoustic Transducer
RESON TC 1037
-
Originally designed for underwater telephone systems, the TC 1037 is a rugged directional transducer ideal for operating at low frequencies.
-
Product
Calibration
-
Calibrations of electronic equipment is one of the activities that Kiwa Dare offers to its clients. these calibrations are under accreditation in the field of electrical quantities. Besides calibrations in the field of DC current, DC voltage and low frequency (test and measuring) equipment, Kiwa Dare is specialized in calibrating high frequency measuring equipment and in particular EMC equipment in a frequency range of (DC) 40 GHz. New the site validation calibrations whereby Kiwa Dare can calibrate shielded rooms (Faraday room) and anechoic chambers under accreditation.
-
Product
Maritime Navigation and Communications Antennas
-
LBA provides equipment and services to support shore station requirements for modern maritime communications in the low frequency, medium frequency, and high frequency radio bands
-
Product
Directional Couplers From 0.01 To 2000 MHz
-
Pulsar Microwave's low frequency directional couplers operate within the frequency range of 10 kHz to 2 GHz. They're available in either surface mount or connectorized designs. SMA female connectors are standard, but BNC, TNC, F, N, jack or plug are available upon request.Most of these directional couplers have a flatness of +/- 0.25 dB and directivity of 20 dB or better within the operating band. VSWR of 1.3:1 or better maintained on all ports for most models. Maximum power handling is between 1 and 3 watts depending on model.
-
Product
Ultra-Low Frequency Spring Activated Vibration Isolation Workstation
MK26 Series
-
The New MK26 Series Vibration Control Workstation with more ergonomic comfort is designed specifically for ultra-low natural frequency applications. Kinetic Systems manufactures the system utilizing the Minus K patented negative stiffness vibration isolators in order to provide a compact, passive Vibration Isolation Workstation with ultra-low natural frequencies, higher internal structural frequencies, and excellent vertical and horizontal isolation efficiencies. The MK26 has also been upgraded to provide much better user comfort and additional leg space.
-
Product
Handheld 3GHz Freqency Counter
PFM3000
-
3 Hz to 3000 MHz in two overlapping rangesHigh input sensitivity over the full frequency rangeHigh impedance measurement up to 125 MHzReciprocal counting technique gives superior resolutionPeriod measurement from 3 Hz to 125 MHzBattery operation and lightweight, handheld formatPush-to-measure function with auto power-downLarge 8+ digit display with full range of annunciatorsSelectable measurement time; display hold functionNoise filter for low frequency measurements
-
Product
Personal RF Detection Meters, Low Frequency
-
Personal RF Detection Meters, Low Frequency by Sensory Perspective Ltd.
-
Product
Compact Juno USB Interface
Juno 7Z01250
-
*Virtual laser power meter - From sensor to interface to PC - no power source needed*Plug and play with all standard Ophir smart sensors*Use with StarViewer free Android app to turn your smartphone / tablet into a power meter*Record every energy pulse at up to 10 KHz*Log power and energy, average, statistics, histograms and more with included StarLab application*New: Pulsed Power measurements with Thermopile sensors*New: Low Frequency Power on Photodiode sensors - power measurement based on pulse cycle (for VCSEL)*System Integrator Tools included: LabVIEW VIs, COM Object Interface*Very compact - is just an extension of the smart plug
-
Product
E-Series Average Power Sensor
E9304A
Power Sensor
Refer to the E9301A for standard power sensor features Low frequency coverage (9 kHz to 6 GHz) for EMC/EMI test applications such as the radiated immunity test (IEC61000-4-3)High sensitivity (-60 to +20 dBm) and fast measurement speed to reduce the time taken to calibrate radiated field uniformity and EMC/EMI test receivers Measure transmitter power and receiver sensitivity at Very Low Frequency (VLF) to microwave frequencies Special option available to 18 GHz Compatible with EPM (new N1913A/ 14A, E4418B/ 19B), EPM-P (E4416A/ 17A) and P-series (N1911A/ 12A) power meters
-
Product
Dual-ridge Horn Antenna 1 to 18 GHz
EH118
-
EH118, a dual-ridge horn antenna that will operate from 1 to 18 GHz. This antenna has a balanced, smooth antenna factor curve that extends all the way to 18 GHz, a reduction of higher order modes on the aperture, and low return loss (SVSWR). The EH118 is applicable for commercial, military and automotive test standards and will include applicable calibrations. The EMC dual-ridge horn antenna offers these key features: single linear polarization, smooth/balanced gain with frequency, low return loss /VSWR, and ultrawide bandwidth (18:1).
-
Product
Passive Probe, 500 MHz, 10:1, 1 MOhm/10 MOhm
PP020-1
-
Passive probes are the standard probe provided with most oscilloscopes. Typical passive probes provide a 10:1 attenuation and feature a high input resistance of 10 MΩ. This high input resistance means that passive probes are the ideal tool for low frequency signals since circuit loading at these frequencies is minimized. Passive probes are designed to handle voltages of at least 400V, some as high as 600V. Teledyne LeCroy passive probes feature an attenuation sense pin which tells the oscilloscope to scale the waveforms automatically requiring no user input.Each passive probe is recommended for a certain oscilloscope, using the right passive probe with the right oscilloscope means that the probe will be properly compensated across the entire bandwidth. Using probes with a different oscilloscope will only let you compensate for low frequencies.
-
Product
÷10, 500 MHz, 10 MΩ, Passive Probe
PP009-1
-
Passive probes are the standard probe provided with most oscilloscopes. Typical passive probes provide a 10:1 attenuation and feature a high input resistance of 10 MΩ. This high input resistance means that passive probes are the ideal tool for low frequency signals since circuit loading at these frequencies is minimized. Passive probes are designed to handle voltages of at least 400V, some as high as 600V. Teledyne LeCroy passive probes feature an attenuation sense pin which tells the oscilloscope to scale the waveforms automatically requiring no user input.Each passive probe is recommended for a certain oscilloscope, using the right passive probe with the right oscilloscope means that the probe will be properly compensated across the entire bandwidth. Using probes with a different oscilloscope will only let you compensate for low frequencies.
-
Product
GEOPHYSICS, SEISMIC, and ATMOSPHERICS RESEARCH RECEIVER
Type RAS-1
-
Called the RAS-1, the receiver is designed for ultra low and very low frequency scientific research work, including the exploration of low frequency emissions due to seismic and earth-quake activity, study of atmospheric phenomenon such as "whistlers", and low frequency Sudden Ionospheric Disturbance (SID) and electromagnetics phenomenon. The RAS-1 will receive signals from under 200 Hz. To over 250 KHz in both narrow bandwidth modes as well as broad badnwidth reception.
-
Product
Digital Combo Set for Measuring Low-Frequency Signals
SVG-5
-
- Measurement of root-mean-square AC voltage and frequency of single-ended or differential signals- Measurement of AC voltage frequency of single-ended or differential signals- Generation of sine waves- Visual examination of freeform signals- Signal spectrum analysis
-
Product
500 MHz Passive Probe, 2.5mm, 10:1, 10 MOhm
PP021-1
-
Passive probes are the standard probe provided with most oscilloscopes. Typical passive probes provide a 10:1 attenuation and feature a high input resistance of 10 MΩ. This high input resistance means that passive probes are the ideal tool for low frequency signals since circuit loading at these frequencies is minimized. Passive probes are designed to handle voltages of at least 400V, some as high as 600V. Teledyne LeCroy passive probes feature an attenuation sense pin which tells the oscilloscope to scale the waveforms automatically requiring no user input.
-
Product
EOC Master
EOCM-7102
-
Hangzhou Softel Optic Co., Ltd.
EOCM-7102 is the outdoor EOC Master of the EOC (Ethernet Over Coaxial) solution. It is in compliant with HomePlug AV standard. The EOCM-7102 have two EOC module. It provide two TV input, two com output and two 10/100/1000M auto-negotiation uplink ports. It offers the high-speed data service to the customer based on the coaxial cable network. The EOC module in the EOCM-7102 is based the Qualcomm AR7410 chipset solution, with high anti jamming capability OFDM technology. The 7.5-65Mhz low frequency band is used for EOC signals. Built in high isolation filter as CATV RF and EOC signal mixer, the EOC signal and CATV signal in 87~862Mhz can running on one cable without interference. The EOC Master can provide high speed data service. The PHY Layer speed is 600Mbps, the MAC Layer throughput is up to 320Mpbs.
-
Product
Long Life Seismic Energy Source
1500LL
-
Excellent low frequency content. Using heavy-duty cluster spreader bars cluster elements in excess of 1,000 cubic inches possible without sacrificing peak output
-
Product
Bench/portable Universal Counters With USB Interface 3GHz Or 6GHz
TF900 Series
-
Frequency, period, pulse width, frequency ratio, duty cycle, and event counter modesDC to 3000 or 6000MHz range, 0.001mHz resolutionHigh impedance measurement up to 125 MHzAC or DC coupling, 1M/50Ohm selection, polarity invertSwitchable attenuator, threshold controlNoise filter for low frequency measurementsSelectable measurement time; display hold functionLarge 10 digit display with full range of annunciatorsInternal rechargeable batteries for portable useUSB interface provides full remote control and readback





























