RF / Microwave Switches
-
product
Switch Modules - 16 Single Pole Relays Arranged as an 8x2 Matrix
JX16/AB-1
This module has 16 single pole relays arranged as an 8x2 matrix as shown in the figure to the left. The matrix may be operated and wired individually for up to 16 8x2's per chassis, or jumpered to the backplane to form up to a 128x2 matrix. It is available with Type S or M reed relays for high speed, long life application. These modules are usually used for 2 wire testing where high and low meter leads must be switched between any two points. Often used for 2 wire LCR meter measurements, cable testing, or open / short testing in a variety of applications.
-
product
Switch Modules - 16 Single or Two Pole Relays Arranged as Four Separate 4x1 Multiplexers
JX16/4(4x1)-1 and -2
This module has 16 single or two pole relays arranged as four separate4x1 multiplexers as shown in the figure. The muxes may be operated and wired individually for up to 64 4x1"s per chassis, or jumpered together to form 8x1"s or 16x1"s or jumpered to the backplane to form up to a 256x1 mux or two 128x1 muxes. It is available with Type S, M or LT reed relays.
-
product
High 1.80 (51.00) - 12.60 (357.00) Switch Probe
TSP138-FK400-3
Current Rating (Amps): 10Average DC Resistance lower than (mOhm): 20Test Center (mil): 138Test Center (mm): 3.50Full Travel (mil): 197Full Travel (mm): 5.00Recommended Travel (mil): 157Recommended Travel (mm): 4.00Overall Length (mil): 1,760Overall Length (mm): 44.70Switch Point (mil): 67Switch Point (mm): 1.70
-
product
PXI Microwave Multiplexer, Single SP8T, 26.5 GHz, 50 Ω, SMA, Failsafe
40-788-041
The 40-788-041 (PXI) and 42-788-041 (PXIe) are single failsafe SP8T 26.5 GHz unterminated microwave multiplexers. The 40/42-788 range of multiplexers are available as single or dual, SP8T, SP10T or SP12T panel mounted multiplexers with relays mounted on the front panel. Remote versions are also available which can support one or two multiplexers in a dual slot module.
-
product
NI-5791, 200 MHz to 4.4 GHz RF Adapter Module For FlexRIO
782510-01
The NI‑5791 provides continuous frequency coverage from 200 MHz to 4.4 GHz. It features a single-stage, direct conversion architecture that provides high bandwidth in the small form factor of a FlexRIO adapter module. The onboard synthesizer, which is the local oscillator (LO), sets the center frequency for acquisition and generation, and you can export it to other modules for multiple input, multiple output (MIMO) synchronization. You can also import the LO from an external connector, enabling synchronization of up to eight NI‑5791 modules. For higher frequencies or a greater number of devices, you can use an external LO distribution amplifier.
-
product
LXI Microwave Multiplexer, SP6T, 5-Bank, 50GHz, 50Ω, SMA-2.4, Terminated
60-800-705
High performance RF multiplexer suitable for switching microwave signals up to 50GHz with automatic termination of unused signals
-
product
PXI/PXIe MEMS Optical Switch, Dual Insert/Bypass, Single-Mode, 9/125 Fiber, FC/PC Connectors, With Interlock
42-860A-122-HI
The 40/42-860A-122-HI is a PXI/PXIe dual insert/bypass switch with FC/PC connectors, includes hardware interlock and is part of Pickering's range of PXI Fiber Optic MEMS Switching modules.
-
product
Coaxial Plug-in Switch Card
1260-152/172
The Astronics 1260-152/172 is a high- frequency coaxial switch card for use in either the Adapt-a-Switch® 1260-100, VXI carrier, or the 1256, GPIB/RS-232 Switching Mainframe.
-
product
PXI 10A Fault Insertion Switch 6-chan 2-bus
40-192-012
This PXI fault insertion switch uses solid state switching elements and is capable of switching current up to 10A. It is designed to be able to insert three different fault conditions between the test fixture and the equipment under test: Open-Circuit. Short-Circuit between UUT connections. Short-Circuit to external signals. Through relays on each channel enable signals to the UUT to be set open-circuit. Fault Insertion Buses allow any channel to be shorted to any other channel and also enable any channel to be connected to an external signal such as Power, Ignition or Ground to simulate fault conditions. The module is supplied with 2 fault buses.
-
product
High-Density PXI Multiplexer Switch Modules
This range of High-Density Multiplexer Switch Modules provides a compact array of MUX solutions with differing combinations of channel counts and poles. Most of our high-density solutions include isolation relays that allow the MUX to be disconnected from the single input/output port, enabling the convenient interconnection of other channels.
-
product
PXI Dual SPDT RF Switch 6GHz 50 SMA Terminated
40-880-001
A range of 50Ω SPDT RF switching with automatic termination of unused signals. Available as a dual switch in a 1 slot PXI module, a quad switch in a two slot PXI module or hex and octal switches in three slot PXI modules.
-
product
PXI Hex SPDT RF Switch 3GHz 50 MCX
40-870-106
The 40-870 is a 50 RF Switch available with 3 or 6 separate SPDT relays in a single PXI slot. Both versions exhibit low insertion loss and VSWR through the use of modern RF relay technology at an affordable cost. The switch banks been carefully designed to ensure excellent and repeatable RF characteristics to frequencies of 3GHz. The injection of noise and unwanted signals into the signal paths of the 40-870 has been minimized by careful attention to the mechanical and electrical design.
-
product
PXI Dual 2 x 2 Fibre Optic (M Mode) SC M62.5
40-860-222-M62.5
Pickering PXI Fiber Optic MEMS Switching cards are available in many high density formats with a choice of 5 different connector styles to suit most applications: FC/APC (for optimal performance), FC/PC and SC/PC for general applications and LC and MU for high density applications. Fiber optic multiplexers create a signal path by redirecting the optical signal into a selected output fiber. This is achieved using Micro-Mechanical Mirrors driven by a highly precise mechanism and activated via an electrical control signal.
-
product
Handheld RF Power Meter
V3500A
The V3500A Handheld RF Power Meter is a compact, handheld instrument that makes accurate RF power measurements in both field and manufacturing applications. With an absolute accuracy as good as 0.21dB, a wide frequency range of 10MHz to 6GHz, and a measurement range of -63dBm to +20dBm, the V3500A is suitable for a wide variety of RF measurement applications. Its built-in power sensor eliminates the need for users to carry both an instrument and a separate sensor module. Truly portable, the V3500A fits easily into your hand or a toolkit. An optional belt loop holster or carrying case with shoulder strap is also available. To optimize flexibility, it is capable of drawing operating power from batteries, an AC-DC converter module, or a computer via USB interface.
-
product
Alternate 1.10 (31.18) - 7.20 (204.00) Switch Probe
TSP100-F180-2
Current Rating (Amps): 5Average DC Resistance lower than (mOhm): 20Test Center (mil): 100Test Center (mm): 2.54Full Travel (mil): 197Full Travel (mm): 5.00Recommended Travel (mil): 157Recommended Travel (mm): 4.00Overall Length (mil): 1,990Overall Length (mm): 50.60Switch Point (mil): 59Switch Point (mm): 1.50
-
product
LXI Microwave Multiplexer, SP6T, 3-Bank, 18GHz, 50Ω, SMA
60-800-103
Our 60-800-103 is a 3 bank terminated SP6T multiplexer and is part of a range of LXI based microwave multiplexers suitable for switching 50 ohm signals up to 18GHz. The 60-800 range is capable of supporting up to 14 banks of 6 channel terminated multiplexers and is ideal for constructing complex microwave switching systems for many applications. Connection is by high performance front panel mounted SMA, SMA-2.9, SMA-2.4 or SMA-1.85 connectors.
-
product
PXI/PXIe MEMS Optical Switch, Triple Insert/Bypass
40-860A-332
The 40/42-860A-332 is a PXI/PXIe triple insert/bypass switch with MU connectors and is part of Pickering's range of PXI Fiber Optic MEMS Switching modules. They are available in many high density formats with a choice of different connector styles to suit most applications: FC/APC (for optimal performance), FC/PC and SC/PC for general applications and LC and MU for high density applications. They are also available with an optional hardware interlock which, when activated, will return all optical switches to their default unpowered state.
-
product
LXI Microwave Multiplexer, SP6T, 11-Bank, 50GHz, 50Ω, SMA-2.4, Terminated
60-800-711
High performance RF multiplexer suitable for switching microwave signals up to 50GHz with automatic termination of unused signals
-
product
PXI Flexible Microwave Module, Dual SP6T Terminated 40 GHz, Single SPDT 40 GHz, 50 Ω, SMA
40-890-006
The 40-890 (PXI) and 42-890 (PXIe) range of PXI microwave modules allows users to specify the mix of relay types, frequencies and quantities based on the application requirements within the capabilities of the module driver card. Choose from the extensive relay selection already available in the Pickering microwave range to create a flexible solution.
-
product
LXI Microwave Multiplexer, SP6T, 12-Bank, 40GHz, 50Ω, SMA-2.92, Terminated
60-800-512
Our 60-800-512 is a 12 bank terminated SP6T multiplexer and is part of a range of LXI based microwave multiplexers suitable for switching 50 ohm signals up to 40GHz. The 60-800 range is capable of supporting up to 14 banks of 6 channel terminated multiplexers and is ideal for constructing complex microwave switching systems for many applications. Connection is by high performance front panel mounted SMA, SMA-2.9, SMA-2.4 or SMA-1.85 connectors.
-
product
LXI Microwave Multiplexer, SP6T, 5-Bank, 40GHz, 50Ω, SMA-2.92, Terminated
60-800-505
Our 60-800-505 is a 5 bank terminated SP6T multiplexer and is part of a range of LXI based microwave multiplexers suitable for switching 50 ohm signals up to 40GHz. The 60-800 range is capable of supporting up to 14 banks of 6 channel terminated multiplexers and is ideal for constructing complex microwave switching systems for many applications. Connection is by high performance front panel mounted SMA, SMA-2.9, SMA-2.4 or SMA-1.85 connectors.
-
product
LXI Microwave Multiplexer, SP6T, 12-Bank, 50GHz, 50Ω, SMA-2.4
60-800-612
Our 60-800-612 is a 12 bank SP6T multiplexer and is part of a range of LXI based microwave multiplexers suitable for switching 50 ohm signals up to 50GHz. The 60-800 range is capable of supporting up to 16 banks of 6 channel multiplexers and is ideal for constructing complex microwave switching systems for many applications. Connection is by high performance front panel mounted SMA, SMA-2.9, SMA-2.4 or SMA-1.85 connectors.
-
product
PXI Triple SPDT RF Switch SMB 75 Ohm
40-830-003
The 40-830-003 is a 75Ω RF Switch with 3 separate SPDT relays in a single PXI slot. It has been designed to exhibit low insertion loss and VSWR through the use of modern RF relay technology at an affordable cost. The switch banks have been carefully designed to ensure excellent and repeatable RF characteristics to frequencies of 3GHz with each path having a nominally equal insertion loss.
-
product
LXI Microwave Multiplexer, SP6T, 14-Bank, 67GHz, 50Ω, SMA-1.85
60-800-814
Our 60-800-814 is a 14 bank SP6T multiplexer and is part of a range of LXI based microwave multiplexers suitable for switching 50 ohm signals up to 67GHz. The 60-800 range is capable of supporting up to 16 banks of 6 channel multiplexers and is ideal for constructing complex microwave switching systems for many applications. Connection is by high performance front panel mounted SMA, SMA-2.9, SMA-2.4 or SMA-1.85 connectors.
-
product
PXIe Flexible Microwave Module, Dual SP6T Terminated 26.5 GHz, Single SPDT 26.5 GHz, 50 Ω, SMA
42-890-004
The 40-890 (PXI) and 42-890 (PXIe) range of PXI microwave modules allows users to specify the mix of relay types, frequencies and quantities based on the application requirements within the capabilities of the module driver card. Choose from the extensive relay selection already available in the Pickering microwave range to create a flexible solution.
-
product
PXI Single 2 x 2 Fibre Optic (M Mode)SCM62.5
40-860-212-M62.5
Pickering PXI Fiber Optic MEMS Switching cards are available in many high density formats with a choice of 5 different connector styles to suit most applications: FC/APC (for optimal performance), FC/PC and SC/PC for general applications and LC and MU for high density applications. Fiber optic multiplexers create a signal path by redirecting the optical signal into a selected output fiber.
-
product
TSP100 Switch Probes
Current Rating (Amps): 5Average DC Resistance lower than (mOhm): 20Test Center (mil): 100Test Center (mm): 2.54Full Travel (mil): 197Full Travel (mm): 5.00Recommended Travel (mil): 157Recommended Travel (mm): 4.00Overall Length (mil): 1,990Overall Length (mm): 50.60Switch Point (mil): 59Switch Point (mm): 1.50
-
product
PXI Solid State Switch Module, 6xSPST, 10 A
40-182A-011
The 40-182A-011 has 6 off high current SPST switches in two PXI slots and is part of our range of high power solid state switching solutions. Each SPST switch uses a fully isolated solid state relay which has been designed to offer fast operation under hot switching conditions and high inrush current with no operational life degradation. Each SPST switch can support 10A of continuous current and switch up to 200V signals. The switch can sustain inrush currents in excess of 50A. AC or DC signals can be switched since the switch is polarity insensitive.
-
product
Basic RF Spectrum Analyzers
Our low-cost RF spectrum analyzers deliver general-purpose functionality and great value with measurement frequencies from 9 kHz to 7 GHz or 1 MHz to 20 GHz. Get the RF spectrum analyzer accuracy you expect with a variety of options provided to you by Keysight.
-
product
PXIe Microwave Multiplexer, Dual SP4T, 26.5 GHz, 50 Ω, SMA, Terminated, Failsafe
42-785C-432-T
The 40-785C-432-T (PXI) and 42-785C-432-T (PXIe) are dual failsafe SP4T 26.5 GHz microwave multiplexers with automatic termination of unused signals. The 40/42-785C range of multiplexers are available in single or dual, SP6T or SP4T configurations with relays mounted on the front panel. Remote versions are also available which can support up to three multiplexers in a single slot.