Current Transformers
transfers accurately proportional levels of current to multiple circuits.
-
Product
For Detecting Low Range And Leakage AC/DC/Pulsed Current.
FDAZCT-20LSP-0.6S
-
MULTI MEASURING INSTRUMENTS Co., Ltd.
*Lowest Influence from Magnetization,Temperature *Change,Residual Current and Terrestrial Magnetism.*Low Cost and High Performance (Output Linearity ±1% F.S)
-
Product
High Side Current Sense Amp
QA150
-
The QA150 makes ultra-low current measurements of your toughest real-time projects a snap. The QA150 is a high side current to voltage converter. Simply tap into the supply for your various project rails (5V, 3.3V, etc) and the QA150 will convert the currents to voltages that you can then capture on your scope, along with whatever other signals you might need. If you are trying to squeeze every last bit of energy from your batteries, the QA150 is your answer.
-
Product
Transformer Testing And Monitoring
-
Can detect the symptoms of transformer failure by monitoring the cooling system, load tap changer, dissolved gas, bushing power factor and capacitance, partial discharge, oil levels, pressure, temperatures and more.
-
Product
30 A Current Shunt
34330A
-
Measure current safely with this precision 0.001 ohm resistor housed in a plastic case surrounded by epoxy.
-
Product
622 HP Eddy Current Chassis Dynamometer
CM-51-EC
-
Weight Capacity: 25,000 lb (11,340 kg) per axleRoll Brakes: pneumatically-actuated discShipping Weight: 8,340 lb (3,783 kg)Capacity: 622 hp at 45 mph (464 kW at 72 kph)Rolls: 20 by 36 in. (508 by 915 mm) long4 front fixed rolls, 2 rear rolls fixed toaccommodate axle spreads from48 to 60 in. (1,219 to 1,524 mm)tandem centersPit Required Depth: 25 in. (635 mm)
-
Product
Transformer Bench Tester
KVBT
-
KV Hipot Power Test Equipment Co.,Ltd
Transformer Test System is applied for ex-work and maintenance detecting on various transformers.
-
Product
Transformer Oil Dielectric Strength Testing
LS -JJ-II
-
Chongqing Lushun Scientific & Technological Development Co., Ltd.
1.The instrument has the function of automatic detection. 2.Tiny TPU-A panel printer is adopted for automatic printing out type insulating oil dielectric strength ATE is a full self-reacting device, which is developed according to the requirements in International IEC-156 and International GB507-86 "Insulating Oil Dielectric Strength Mensuration", combining the feedback opinions of all users .The instrument adopts singlechip as the leading part, and uses the method of "first setting and then testing". The whole process is controlled by automatic microcomputer. It is operated simply and used conveniently.
-
Product
Transforming Analog Circuit Breaker Testers
MAC-21
-
The MAC-21 uses proven microprocessor and A/D converter technology to provide real-time waveform analysis. This ensures accurate true-RMS readings of current pulses, even with DC offset and distortion, which are typical in primary injection testing. Intelligent threshold algorithms provide accurate trip time measurement. Integration of measurement and control functions allow advanced features such as preset on times, auto ranging, and optional printer or computer interface.
-
Product
400 MHz High Voltage Differential Probe
DP0001A
High Current Probe
The DP0001A is a 400 MHz high voltage differential probe with 2 kV mains isolated or 1 kV CAT III rating designed for making accurate high-voltage power measurements required for testing today’s WBG power devices, power converters or motor drives.
-
Product
Current Probe
DCP-BTA
-
Vernier Software & Technology, LLC
The Current Probe measures DC and low-frequency AC currents up to 600 mA. Use Current Probes in combination with Differential Voltage Probes to investigate Ohm's Law and explore series and parallel circuits. The 0.1 shunt resistor minimizes changes to your circuit. If currents will exceed 1 A, use the High Current Sensor.
-
Product
Current Preamplifier
1641
-
The Model 1641 Current Preamplifier is a simple low cost wideband gain block for use with photomultipliers
-
Product
Automatic Transformer Tester
SS3250 / SS3252 / SS3302
-
Automatic transformer test instrument is a precision test system, designed for transformer production line or incoming/outgoing inspection in quality control process, with high stability and high reliability. With the enhanced capability in turn ratio measurement, they can solve the measuring problems of low coupling coefficient, transformer's turn ratio and turn number with more precise measurement.
-
Product
DGA Monitor for Transformers
OPT100 Optimus™
-
The Vaisala Optimus OPT100 DGA (Dissolved Gas Analysis) Monitor for Transformers gives you out of the box performance, completely eliminates false alarms, and offers the best long-term stable measurements of any device on the market – all with no maintenance. Spectral scanning provides selective gas measurement.
-
Product
High Voltage Surge Current Monitors
HVSCM
-
Designed to be used with the Model HVST High Voltage Surge tester. The Surge Current Monitor allows simultaneously surge testing 20 units. The Surge Current Monitor monitors the current going through each unit under test at the time of the surge. If a unit under test breaks down or leaks, the Surge Current Monitor will identify the bad unit by lighting the corresponding LED. The most important features of the surge tester are its ability to test the entire winding insulation system. A high voltage surge generates turn to turn, coil to coil, and phase to phase voltage stress, as well as ground insulation stress. When used as a dielectric test, accurate voltage readings are essential. The HV Surge Tester monitors the voltage directly across the winding under test. In production testing we expect that most of the time the devices will pass. In the event that one should fail, the failed device would be removed and then all the parts would have ot undergo another surge test. Since most devices pass most of the time, simultaneous surge testing can be a real time saver.
-
Product
Partial Discharge Testing Of Transformer & Localization System
AE-150™
-
The is designed to detect and localize Partial Discharge activity by correlating acoustic and electric sensors' data. The AE-150™ has many acquisition modes, each used for detecting and locating Partial Discharge activity in a transformer. The AE-150™ unit is mounted on the transformer tank using its powerful magnets that also hold four acoustic sensors.
-
Product
30A Auto Current & Voltage Tester
7610A
-
Peaceful Thriving Enterprise Co Ltd
*Fast, accurate and safety current measurement from the fuse box.*Feature with large LCD display and mini/ATO fuse probe.*Ideal for diagnostic of vehicle's electrical circuits.*With CE Approval.
-
Product
Transformer Test Equipment
-
KV Hipot Power Test Equipment Co.,Ltd
Transformer Test Equipment. Ensure that a transformer meets performance and reliability requirements, from the production line to after a repair or upgrade, when a major disruptive event occurs such as a lightning strike, or for preventive/predictive maintenance.
-
Product
Split type AC Current Sensor
CTF-400A
-
MULTI MEASURING INSTRUMENTS Co., Ltd.
* Suitable for current measurements of main cable. * Wire stopper is equipped for the slipping protection. * The special connector is not necessary as the output terminals are provided. * Open circuit protection and nonflammable plastic material.
-
Product
High-Voltage Differential Probe, 25 MHz
N2791A
High Current Probe
Use the N2791A 25-MHz low-cost high-voltage differential probe to make safe and accurate floating measurements with an oscilloscope. The N2791A differential probe allows conventional earth-grounded Keysight oscilloscopes to be used for floating signal measurements of up to 700 V of differential voltage and common mode voltage.
-
Product
Integrated Current Sensors
-
Current sensors have to be smaller, smarter, cheaper. LEM’s R&D is actively developing a range of ICS to reduce the footprint of the current sensing function and simplify the integration of current measurement in a wide range of applications in automotive, industrial, or residential.
-
Product
Through Hole type DC Current Sensor/for Load Current Measurements
MOHT-800B Open loop method
-
MULTI MEASURING INSTRUMENTS Co., Ltd.
*Hall effect measurement for DC/AC/Pulsed current.*For the use of UPS, batteries, switching power supply, DC motor drivers, etc.
-
Product
200 Amp AC Current Adaptor
DL6701
-
The DL6701 is a compact 200A AC current clamp adaptor with voltage output via standard 4 mm connectors. To be connected to a digital multimeter or other voltage measurement device.
-
Product
Current Injection
-
K&S Engineering and Scientific Ltd
The outputs are continuously variable from zero and are all isolated. The current outputs can be used at twice their continuous rated current on a 25% duty cycle with a maximum ON time of 5 minutes.
-
Product
Closed Loop Hall AC/DC Current Sensor
CYHCS-D8
-
ChenYang Technologies GmbH & Co. KG
This Hall Effect current sensor is based on closed loop compensating principle and can be used for measurement of DC and AC current, pulse currents etc. The output of the transducer reflects the real wave of the current in the carrying conductor.
-
Product
Transformer Turns Ratio Meter
TTRM 102
-
SCOPE introduces state of the art precision single phase Transformer Turns Ratio Meter (TTRM ) designed for field testing as well as factory testing of power transformers, instrument transformers and distribution transformers of all types. TTRM 102 along with turns ratio, measures ratio deviation, phase angle deviation, magnetizing current and detects tap-position of single phase transformer in charged switchyard condition. The range of AC voltage selection offers high accuracy in measurement.Both the instrument have in-built TFT display with touch screen and thermal printer. The user friendly, simple instrument makes the testing more easy. With the touch keypad it is possible to enter required DUT information.The ratio results are displayed with % error. Internal non-volatile memory gives the provision of storing test results.Further data can be downloaded to PC or copied to memory stick through USB port provided.
-
Product
Current Measurement Board
MS 1814
-
*Maximum DC Voltage Rating: 15V to 75V*Maximum DC Current: 5A*Output Voltage per 1A: 1V*Maximum AC Current: 5A*Operating Temperature: 0°C to 55°C*Storage Temperature: -20°C to +65°C*90% Relative Humidity (Non-condensing)*No. of DC Current Channels: 9*No. of AC Current Channels: 4nos*Maximum AC Voltage Rating: 230VAC*Channel Selection: Through 16 CH Analog MUX*Measurement Error Over Full Temperature Range: 5%*Type of Output: Proportional voltages*Maximum Voltage Drop across Series Resistor Full Scale Measurement: 0.05VDC
-
Product
AC/ DC mA Current Clamp-on Transducer
CA-60
-
This miniature clamp meter features two Hall effect sensors. For use with any multimeter with 200mV or/and 2V ranges for direct readout input impedance of least 1M ohm. High conversion factor for low DC and AC mA measurement. With the small jaw size it can fit into tight space in circuit panel or wire bundle to take the reading.
-
Product
OEM Current Input0 to 20mA
TGPR-0800
-
A current input data logger that is supplied uncased so that it can be built into custom applications.The TGPR-0800 can be used to record the output from a number of industry standard 4-20mA sensors. Common applications include pressure and flow rate monitoring.
-
Product
AC/DC Current Probe (1-Channel), 3 MHz, 50 UA
N2821A
Battery Probe
As modern battery-powered devices and integrated circuits become more green and energy efficient, there is a growing need to make high-sensitivity, low-level current measurements to ensure the current consumption of these devices is in acceptable limits. The N2821A high-sensitivity probe is engineered to make high-dynamic-range, high-sensitivity measurements to meet today’s challenging current measurement needs.
-
Product
Grounding Transformers [ZN (Zigzag), ZNyn, YNd(open), Ii0]
-
Grounding Transformers are designed for providing an artificial neutral point for ungrounded three phase power systems. During the line-to-ground faults, grounding transformers provide an easy path to ground faults to limit the fault currents and transient overvoltages.