Calibrators
ascertain instrument graduation deviation and rectify to precision known values.
See Also: Calibration, Power Calibration, Display Calibration, Calibration Standards, Calibration Software, Calibration Services, Calibration References
-
product
pH 700 Benchtop pH Meter
The easy-to-use, microprocessor-based pH 700 benchtop meter measures pH, mV, relative mV, and temperature. The large, dual-display LCD provides excellent visibility—even from a distance. Automatic temperature compensation (ATC) maintains reading accuracy even with fluctuating temperatures. Five-point pH calibration, with automatic buffer recognition for both USA (pH 1.68, 4.01, 7.00, 10.01, 12.45) and NIST (pH 1.68, 4.01, 6.86, 9.18, 12.45) pH buffers, makes for easy calibration no matter which requirement you need to meet. Meter features HOLD, ATC, selectable °F or °C measurement, recall of electrode slopand offset, and electrode diagnostics. The convenient pull-out quick reference card keeps procedures handy at all times. Meter accepts any pH or ORP electrodes with a BNC connector.
-
product
Remote Sensing Wind Measurement Device
WINDCUBE
WINDCUBE is a remote sensing wind measurement device that uses pulsed Doppler Lidar technology to provide high quality data on par with an IEC calibrated met mast. Introduced to the market by LEOSPHERE, WINDCUBE has quickly become recognized as the market standard for superior performance for both wind resource assessment and wind farm performance monitoring. Lenders have readily adopted data provided by WINDCUBE and consider this device to be “best-in-class.” WINDCUBE is categorized as being in Stage 3 of DNV GL’s rigorous standards related to remote sensor acceptance for formal energy assessment purposes.
-
product
Miniature Concentric Ring Set
PRF-912B
- Measures Surface Resistance from 0.9Ω to 1.0x1012Ω- Approximates Measurements Typically Obtained when using ANSI/ESD STM11.11- Spacing Allows for Measurement Area of 0.32 inches (8.13mm)- Spring Loaded Center Electrode Surrounded by 10 Contact Electrodes- Includes Conductive Rubber Covers- Certificate of Calibration Traceable to NIST included
-
product
DH Series QuickLink Adapter, 8 GHz BW
DH-QL
Teledyne LeCroy’s DH series 8 to 30 GHz differential probes offer the combination of bandwidth, input range and offset capability to address any high-speed probing requirement from debugging serial data interfaces to validating DDR memory systems. DH series probes provide superior loading characteristics and are calibrated with a custom “fine-tuned” frequency response. The ultra-low loading and flat frequency response ensure accurate measurements.
-
product
Calibration Standards
The accuracy of any spectroradiometric measurement can only be as good as that of the standard source used to calibrate the system.
-
product
Salinity Concentration Pocket Water Meter
LAQUAtwin Salt-11
The only pocket meter that directly measures conductivity in 0.12ml sample and converts it into salinity or salt concentration. No need for a beaker to calibrate the meter or measure a sample. Just place few drops of the standard or sample onto the sensor. This procedure saves you time and prevents wasting your precious sample.
-
product
Bench-top Optical Light Source
STC-BTOLS2201 series
Shanghai Stone Communication tech Co., Ltd
STC-BTOLS2201 series high stable Bench-top light source are microprocessor controlled laser diode sources which can support the variety of emitters such as: DFB,FP,PUMP,SLED etc. It is specially used in passive components testing, power meter calibration and general laboratory uses.
-
product
Vector And Scalar Mixer/Converter Measurements
S93083B
The S93083B provides both fully calibrated vector and scalar measurements of mixers and frequency converters, with intuitive, easy-to-use user interface
-
product
Pressure Comparators
AMETEK Sensors, Test & Calibration
Our high-pressure, hydraulic pressure comparators are portable, self-contained, hydraulic pressure generators for calibrating pressure gauges, transmitters, sensors, and safety valves. They are much faster than deadweight testers and most automated pressure controllers; and it’s so quick and easy to use, it’s ideal for calibrating those low cost gauges that are often overlooked for ISO9000 compliance. Each pump is available on its own, or in one of our complete ready-to-use pump systems.
-
product
Conformance Calibration Standard Test Card for UPC/EAN Symbol Verifiers
AI-CCS-UPC/EAN-E Rev S
For those who prefer a traditional vertical format calibration test card, APPLIED IMAGE offers our new Conformance Calibration Standard Enhanced for UPC/EAN Bar Code Symbol Verifiers. The new standard complies with both the ANSI X3.182 and ISO 15416 standards and is ideal for testing of verifiers, scanners, and other UPC bar reading equipment as well as a tool for training new operators to assure proper “methodology' in the use of verifiers.
-
product
Pressure Meters
An individually-numbered Traceable® Certificate provided with each unit, assures accuracy from our ISO/IEC 17025:2005 (1750.01) calibration laboratory accredited by A2LA. It indicates traceability of measurements to the SI units through NIST or other recognized national measurement institutes (NMI) that are signatories to the CIPM Mutual Recognition Agreement.
-
product
Portable Temperature Calibrators
Portable temperature calibrators (dry-well calibrators) are electronic controllers which automatically, quickly and dryly supply a temperature. Due to the high reliability, accuracy and simple operation, portable temperature calibrators are particularly suitable as a factory/working standard for the automatic testing and/or calibration of temperature measuring instruments of all types. A major advantage is offered by the large sleeve diameters and the fast, stable temperature control, since, as a result of these characteristics, the time for calibration can be used very effectively.
-
product
Averaging Clip-on Extensometer
2650 Series
The Instron 2650 Series Biaxial Extensometers are ideally suited for testing a wide range of materials, including polymer matrix composites, metals, and plastics over a range of temperatures. Two sensors measure axial strain on opposite sides of the specimen. Versions are available which provide either a single averaged axial output or 2 independent axial outputs. The extensometers meet the calibration requirements of ASTM E83 class B1, ISO 9513 class 0.5, and ISO 527.
-
product
Calibration
EMC Test Antennas
There are some changes in the calibration standard ANSI C63.4 concerning the calibration procedures of hybrid antennas, also the newly issued standard - CISPR 16-1-6 dealing with EMC antenna calibration is covered by our services. You are very welcome to consult Seibersdorf Laboratories calibration experts for the recommended calibration procedures of the most common radiated emission test standards.
-
product
Data Logger for Temperature and Humidity
DSR-TH(professional)
Built-in compact high precision temperature and humidity sensors Selectable USB, RS232/485, LAN, wireless communication interfaces High definition LCD with wider viewing angles and redundant operation temperature Support on-line linear and nonlinear calibration Suitable for pharmaceutical, electronic production, biochemistry laboratory, museum management and other applications
-
product
UV/VIS/NIR Spectrophotometer Calibration Standards
As the world's foremost spectrophotometer reference standard manufacturer, we have a dedicated staff and years of experience to back up our products. Our solid state UV/VIS/NIR reference standards are the most stable on the market and remain in spec long after many other manufacturer's standards go bad. Relying on our proprietary nano-deposition technology, you can rest assured that our solid-state standards will produce steady readings for years to come on your machines.
-
product
NI-9216, 8-Channel, 400 S/s Aggregate, 0 Ω to 400 Ω, PT100 RTD C Series Temperature Input Module
783863-01
8-Channel, 400 S/s Aggregate, 0 Ω to 400 Ω, PT100 RTD C Series Temperature Input Module - The NI‑9216 is a resistance temperature detector (RTD) input module. You can configure the NI‑9216 for two sample rate modes: high sample rate or high resolution. The NI‑9216 is compatible with 3‑ and 4‑wire RTD measurements, and it automatically detects the type of RTD (3-‑or 4‑wire) connected to the channel and configures each channel for the appropriate mode. The module provides per channel current excitation. The NI‑9216 features calibration and includes a channel‑to‑earth ground double isolation barrier for safety, noise immunity, and a high common-mode voltage range.
-
product
Palm Size Digital Multimeter, Calibrated, 1999 Count, Mean Value, Manual Range, 3.5 Digit
72-7770 CAL
The 72-7770 CAL from Tenma is a palm sized digital multimeter with 3 3/4 digit LCD. It is 3 1/2digits with steady operations, fashionable design and highly reliable hand held measuring instrument. The meter measures AC/DC voltage, AC/DC current, resistance, temperature, diode and continuity. It is an ideal tool for maintenance. The multimeter features square wave output, data hold, low battery indicator and display backlight, This meter complies with the standards CE, IEC61010, in pollution degree 2, overvoltage category (CAT I 600V, CAT II 300V) and double insulation.
-
product
Calibration Kit
F7511
F7511 Calibration Kit, Frequency Range: up to 3 GHz, Impedance: 75 Ohm, Connector type: F-type
-
product
Monochrome USB3 Vision, 1.6 MP, 220 FPS Area Scan Camera
787069-01
The acA1440-220uc is a Color Basler Ace USB3 Vision Camera with a 1.6 MP resolution and a maximum image acquisition speed of 220 frames per second. The acA1440-220uc uses a IMX273 sensor and is quality tested and calibrated for high performance and reliability. This camera can be used with NI hardware and software to build machine vision systems.
-
product
Current Sensing
voltage-output, current-sensing amplifier family that integrates an internal shunt resistor to enable high-accuracy current measurements at common-mode voltages that can vary from 0 V to 36 V, independent of the supply voltage. The device is a bidirectional, low- or high-side current-shunt monitor that allows an external reference to be used to measure current flowing in both directions through the internal current-sensing resistor sensor. The integration of the precision current-sensing resistor provides calibration equivalent measurement accuracy with ultra-low temperature drift performance and ensures an optimized Kelvin layout for the sensing resistor is always obtained.
-
product
High Precision Angular Position, Calibration and Geometry Inspection
GeoOrdinate
Rotary Precision Instruments UK Ltd
Ultra precise rotary tables intended for fine inspection, metrology and test applications.The GeoOrdinate has been designed specifically for the inspection of large and heavy components and is fully compatible with any shop floor environment whilst maintaining world class accuracies more commonly seen in the standards laboratory.
-
product
Fiber Optic Power Meters
FOD1204H
The FOD 1204 & FOD 1204H Fiber Optic Power Meters are intended for accurate measurements of up-to-date optical communication. Very small temperature and temporal variations of Loss in Fibers and Connectors. Calibration of Optical Attenuators, Light Sources etc.
-
product
Portable Calibration Shaker Table
AT-2030
The AT-2030 portable calibration shaker table is designed for simple accelerometer and vibration transducer calibration without the need for advanced features. AT-2030 shaker table and vibration calibrator is a variable frequency, variable amplitude, battery operated portable shaker capable of calibrating accelerometers, transducers, and proximity probes. Applications are producing a known vibration signal in g’s, mils, or ips for sensor, wiring, instrumentation, and system checkout in vibration condition monitoring applications.
-
product
IEC Standard Burden Sets (Current)
IEC Burden Sets
Testing and calibrating current transformers often requires standard burdens of reliable accuracy and stability, and burdens that are immune to stray fields and harmonics. These burden sets have been carefully designed to meet these requirements. They also provide the standard burdens required for the testing of current transformers for metering service, and for the testing (within the current rating provided by the sets) of current transformers for relaying applications, all as called for by IEC (International Electrotechnical Commission) Publication 185: 1987.
-
product
Nitrate Ion and Nitrate-Nitrogen Concentrations Pocket Water Meter
LAQUAtwin NO3-11C/NO3-11S/NO3-11
The only pocket meter that directly measures nitrate ion and nirate-nitrogen concentrations in 0.3ml sample (or 0.05ml sample with sampling sheet B). Unique sensor allows measurement of viscous liquids, solids, and even powder samples. No need for a beaker to calibrate your meter or measure a sample. Just place few drops of the standard or sample onto the flat sensor. This procedure saves you time and prevents wasting your precious sample.
-
product
Temperature Calibration
Trescal provides full Temperature Calibration services that are accredited and/or certified in accordance with ISO/IEC 17025. Temperature Calibration services can be delivered at your site or at our lab. Accreditations for our temperature calibration service guarantees calibration results are traceable to the International Systems of units (SI) through NIST or NRC.
-
product
Automatic Calibration Function oH Meter
AH-151
The pH meter AH-151 with automatic calibration function performs pH measurement by automatically cleaning the electrode with cleaning solution and performing calibration with standard solution, making it possible to drastically reduce maintenance work. In addition, by spraying the calibration solution, the consumption of calibration solution has been reduced. The spray amount of the cleaning solution can also be adjusted according to the condition of contamination, which contributes to cost reductions. With periodic cleaning and calibration, stable and highly reliable pH measurements are possible.
-
product
Insulation Tester Calibrator
DecR
SCOPE offers High Resistance, High Voltage Decade Resistance Box - DecR. It contains number of smartly configured precision resistors. They are arranged in such a way that user can obtain desired resistance value by selecting appropriate decade switches. DecR is designed using the high quality specially selected resistors. These range of high ohm resistance decades are ideal for variety of applications, having a voltage rating up to 5 kV. It covers the resistance range from 1 kilo ohm to 1 tera ohm. DecR can also be customized as per requirement. DecR is housed in a rugged case and available in 3 / 4 / 6 / 9 decades or in binding post configuration
-
product
Shuttle Bus cPCI Intelligent Interface Card
IIB-SB-CPCI
The Shuttle Bus cPCI is an intelligent interface card providing all Launch Data Bus, Ground Data Bus, and Multiplex De-Multiplex Multiple Remote Terminal capability to the Shuttle Bus, as required by NASA specification 84K01203 (Hardware Specification, Launch Data Bus (LDB) and Ground Data Bus (GDB) Interface Board).In summary, this card provides all features and functions required to meet the above specification, in a cPCI platform, with Simplex & Half-Duplex modes provided. Specific operational modes provided include for LDB_BCT, LDB_MRT, GDB_BCT, GDB_MRT, BUS_MON, MDM_MRT, Primitive and Calibration modes.