Vibration Sensors
Sensors used for measuring, displaying and analyzing linear velocity, displacement and proximity, or else acceleration. They can be used on a stand-alone basis, or in conjunction with a data acquisition system. (sensors-transducers.globalspec.com)
See Also: Vibration Test
-
product
E-Series Average Power Sensor
E9301A
Measure the average power of all modulation formats Wide dynamic range (-60 dBm to +20 dBm) and frequency range 10 MHz to 6 GHzHigh maximum power specification Low SWR for reducing mismatch uncertainty Calibration factors linearity and temperative compensation data stored in EEPROM Fast measurement speeds (up to 400 readings per second with the Keysight E4416A)Compatible with EPM (new N1913A/ 14A, E4418B/ 19B), EPM-P (E4416A/ 17A) and P-series (N1911A/ 12A) power meters
-
product
Waveguide Power Sensor
E8486A
Keysight waveguide power sensors are fully compatible with Keysight EPM (E4418B/19B, N1913A/14A), EPM-P (E4416A/17A) and P-Series (N1911A/12A) power meters. The V8486A and W8486A are also compatible with the discontinued or obsolete power meters such as 435B, 436A, 437B, 438A, 70100A, E1416A, E4418A, and E4419A power meters.
-
product
Waveguide Power Sensor
Q8486D
Excellent SWR for reducing mismatch uncertainty50 MHz calibration port Accurate calibration and traceability to US National Institute of Standards and Technology (NIST) millimeter-wave sensor calibration Compatible with EPM (new N1913A/ 14A, E4418B/ 19B), EPM-P (E4416A/ 17A) and P-series (N1911A/ 12A) power meters, plus the E1416A VXI and discontinued 70100A and 43X power meter Accurate average power measurements over -70 to -20 dBm Frequency range 33 GHz to 50 GHz Diode power sensing element
-
product
Power Sensor
8483A
The 8483A diode power sensor measures average power over the frequency range 100 kHz to 2 GHz and power range -30 to +20 dBm (50 dB dynamic range).
-
product
Thermocouple Power Sensors
N8485A
N8480 Series Power Sensors are the replacement solutions for 8480 Series Power Sensors.
-
product
10 MHz – 18 GHz USB Power Sensor
U2000B
U2000B USB Power Sensor measures average power over the frequency range 10 MHz to 18 GHz and power range -30 dBm to +44 dBm.
-
product
USB Sound And Vibration Measurement Bundle
The USB Sound and Vibration Measurement Bundle provides a portable, USB-based sensor measurement system that helps you measure signals from integrated electronic piezoelectric (IEPE) and non‑IEPE sensors such as accelerometers, tachometers, and proximity probes.
-
product
Universal LightProbe S2 Sensors
Optomistic Products’ Universal LightProbe S2 Sensors are designed for the In-circuit, Functional or Finished Product test of an LED’s color and/or intensity. Implemented in a unique and customizable 2-Part solution, the S2 Sensor is assembled with your choice of Fiber-Optic Probe, including for the test of densely-spaced LEDs, bright LEDs, dim or misaligned LEDs, right-angle LEDs, and more, including the popular “Trident” Fiber-Optic Probes to sequentially test 3 LEDs with a single Sensor.
-
product
E-Series Peak and Average Power Sensor, 50 MHz to 18 GHz
E9326A
The E9326A power sensor has a 1.5 MHz video bandwidth and is ideal for time-gated peak, average and peak-to-average ratio power measurements on TDMA and CDMA wireless formats such as Bluetooth.
-
product
10 MHz To 54 GHz USB Wide Dynamic Range Peak And Average Power Sensor
U2066XA
Accurately measure any modulated signal with the Keysight Technologies, Inc. U/L2050/60 X-Series wide dynamic range power sensors. The USB/LAN connectivity models come with a wide dynamic range, covering -70 to +26 dBm. This sensor offers very accurate and repeatable power measurements for any modulated signal and comes with a super-fast measurement speed of 50,000 readings/sec, which enables higher manufacturing throughput. Users can also save time and reduce measurement uncertainty with the internal zero and calibration function. The U/L2050/60 X-Series is supported by the Keysight BenchVue software. BenchVue makes it easy to control your power meter to log data and visualize measurements in a wide array of display options without any programming. Simply connect the sensor to your PC installed BenchVue BV0007B Power Meter/Sensor Control and Analysis app to perform average power measurement and analysis.
-
product
10 MHz – 6 GHz USB Power Sensor
U2001B
U2001B USB power sensor measures average power over the frequency range 10 MHz to 6 GHz and power range -30 dBm to +44 dBm.
-
product
S2 Penta Sensors
ULP-S2 PCI/V
Optomistic Products’ best-selling Sensor, the ULP S2 Penta Sensor, is relied upon for its versatility in accommodating most LED color and intensity test applications. Implemented in a unique and customizable 2-Part solution, the S2 Penta Sensor is assembled with your choice of Fiber-Optic Probe, including for the test of densely-spaced LEDs, bright LEDs, dim or misaligned LEDs, right-angle LEDs, and more, including the popular “Trident” Fiber-Optic Probes to sequentially test 3 LEDs with a single Sensor.Operating temperature range: 0oC to 70oCPower consumption:Operates between +5 and 28 volts D.C., at 6mA max. Less than 4.75 volts is not recommendedVoltage protection: Withstands up to +40 volts, & reverse polarity to -18 voltsOutput Loads: ‘Int.’& ‘Color’- 2Kohms min., 100pF max.Output Pins: 4 gold-plated standard wire-wrap pins (0.025 in. sq.)Sensor Size: 0.560 in. dia x 1.38 in. longTypical response times: Typical response time: <10mS capture time; <100mS overall responsetime for color and intensity simultaneouslyFiber-Optic Probes: Can be paired with any Universal LightProbe Fiber-Optic Probe
-
product
Thermocouple Power Sensors
N8488A
N8488A power sensor has the widest frequency range among N8480 power sensors offering from Keysight.
-
product
Frequency Selective Power Sensor
NRQ6
The R&S®NRQ6 is based on receiver technology and can perform band-limited power measurements down to -130 dBm. The R&S®NRQ6 combines high-precision with high-speed measurements beyond the limits of currently available power meters. In addition to conventional continuous average measurements, the R&S®NRQ6 has a trace display function and also performs ACLR measurements.
-
product
10 MHz to 6 GHz USB Wide Dynamic Range Average Power Sensor
U2051XA
The Keysight U2051XA is a fast, accurate and wide dynamic range 10 MHz – 6 GHz USB average power sensor.
-
product
Power Sensor and SNS Noise Source Cable (6.1m/20 feet)
11730C
The Keysight 11730 series power sensor cables are used with the 8480 and E-series power sensors (except the E9320 family of peak and average sensors). These cables are designed to reduce RFI effects on low power readings with an improved shielding design in the cable itself. Cables may be ordered individually or in pairs in any combination desired for single and dual-channel measurements.
-
product
PCI-4461, 204.8 kS/s, 118 dB, 3.4 Hz AC/DC Coupled, 2-Input/2-Output Sound and Vibration Device
779307-01
The PCI‑4461 is a high-accuracy data acquisition module specifically designed for sound and vibration applications. It provides simultaneous two-channel dynamic signal generation and simultaneous two-channel dynamic signal acquisition with six gain settings to configure the input range. The PCI‑4461 also includes software-configurable AC/DC coupling and integrated electronic piezoelectric (IEPE) conditioning to ensure precision measurements with microphones, accelerometers, and other transducers that have very large dynamic ranges. Common applications include audio test; automotive test; noise, vibration, and harshness (NVH) analysis; and machine condition monitoring.
-
product
NI-9230, 3-Channel, 12.8 kS/s/channel, ±30 V, C Series Sound and Vibration Input Module
784396-01
3-Channel, 12.8 kS/s/channel, ±30 V, C Series Sound and Vibration Input Module - The NI‑9230 can measure signals from integrated electronic piezoelectric (IEPE) and non‑IEPE sensors such as accelerometers, tachometers, and proximity probes. The NI‑9230 is also compatible with smart TEDS sensors. The NI‑9230 incorporates software-selectable AC/DC coupling, IEPE open/short detection, and IEPE signal conditioning. The input channels simultaneously measure signals. Each channel also has built-in anti-aliasing filters that automatically adjust to your sample rate. When used with NI software, this module provides processing functionality for condition monitoring such as frequency analysis and order tracking.
-
product
NI-9234 and cDAQ-9171 USB Sound and Vibration Measurement Bundle
865664-01
NI-9234 and cDAQ-9171 USB Sound and Vibration Measurement Bundle - The USB Sound and Vibration Measurement Bundle with NI-9234 and cDAQ-9171 includes the NI-9234 C Series Sound and Vibration Input Module and the cDAQ-9171 CompactDAQ Chassis for sound and vibration measurements. This bundle provides a portable, USB-based sensor measurement system that helps you measure signals from integrated electronic piezoelectric (IEPE) and non IEPE sensors such as accelerometers, tachometers, and proximity probes. The included NI-9234 features 4 channels with built-in anti-aliasing filters that automatically adjust to your sample rate. Additionally, when used with NI software, the bundle provides processing functionality for condition monitoring such as frequency analysis and order tracking.
-
product
USB-4431, 102.4 kS/s, 100 dB, 0.8 Hz AC/DC Coupled, 4-Input/1-Output Sound and Vibration Device
780164-01
The USB-4431 is designed for sound and vibration measurements. Input channels incorporate integrated electronic piezoelectric (IEPE) signal conditioning for accelerometers and microphones. The four USB-4431 input channels simultaneously digitize input signals. The analog output (AO) channel is ideal for stimulus-response tests and can be synchronized to the AI channels.
-
product
DC/10 MHz – 18 GHz USB Thermocouple Power Sensor
U8481A
The U8480 series is the fastest USB thermocouple sensor in the world without compromising the best in class linearity of the legacy 8480/N8480 series thermocouple sensors, all in a compact USB based form factor
-
product
DC/10 MHz – 33 GHz USB Thermocouple Power Sensor
U8485A
The U8480 series is the fastest USB thermocouple sensor in the world without compromising the best in class linearity of the legacy 8480/N8480 series thermocouple sensors, all in a compact USB based form factor.
-
product
NI-9232, 3-Channel, 102.4 kS/s/channel, ±30 V, C Series Sound and Vibration Input Module
784397-01
3-Channel, 102.4 kS/s/channel, ±30 V, C Series Sound and Vibration Input Module - The NI‑9232 can measure signals from integrated electronic piezoelectric (IEPE) and non‑IEPE sensors such as accelerometers, tachometers, and proximity probes. The NI‑9232 is also compatible with smart TEDS sensors. The NI‑9232 incorporates software-selectable AC/DC coupling, IEPE open/short detection, and IEPE signal conditioning. The input channels simultaneously measure signals. Each channel also has built-in anti-aliasing filters that automatically adjust to your sample rate. When used with NI software, this module provides processing functionality for condition monitoring such as frequency analysis and order tracking.
-
product
10 MHz to 40 GHz LAN Wide Dynamic Range Peak and Average Power Sensor
L2064XA
The Keysight L2064XA is a fast, accurate and wide dynamic range 10 MHz – 40 GHz LAN peak and average power sensor.
-
product
E-Series Average Power Sensor
E9300H
Measure the average power of all modulation formats Wide dynamic range power measurements from -50 dBm to +30 dBm Frequency range 10 MHz to 18 GHzLow SWR for reducing mismatch uncertainty Calibration factors, linearity and temperature compensation data stored in EEPROM Compatible with EPM (new N1913A/ 14A, E4418B/ 19B), EPM-P (E4416A/ 17A) and P-series (N1911A/ 12A) power meters
-
product
10 MHz – 6 GHz USB Power Sensor
U2001A
U2001A USB power sensor enable fast, simple setup by providing plug-and-play USB connectivity and by eliminating the need for a separate power meter.
-
product
Thermal Power Sensors
NRPxxT/TN/TWG
The R&S®NRP power meter sensors have long been recognized for delivering supreme precision and speed. The R&S®NRPxxT, R&S®NRPxxTN and R&S®NRPxxTWG thermal power sensors are especially used for complex measurement tasks where highest accuracy counts
-
product
E-Series Peak and Average Power Sensor, 50 MHz to 6 GHz
E9321A
The E9321A power sensor has a 300 kHz video bandwidth and is ideal for time-gated peak, average and peak-to-average ratio power measurements on TDMA wireless formats such as NADC, GSM and EDGE.
-
product
NI-9230, 3-Channel, 12.8 kS/s/channel, ±30 V, C Series Sound and Vibration Input Module
783824-02
3-Channel, 12.8 kS/s/channel, ±30 V, C Series Sound and Vibration Input Module - The NI‑9230 can measure signals from integrated electronic piezoelectric (IEPE) and non‑IEPE sensors such as accelerometers, tachometers, and proximity probes. The NI‑9230 is also compatible with smart TEDS sensors. The NI‑9230 incorporates software-selectable AC/DC coupling, IEPE open/short detection, and IEPE signal conditioning. The input channels simultaneously measure signals. Each channel also has built-in anti-aliasing filters that automatically adjust to your sample rate. When used with NI software, this module provides processing functionality for condition monitoring such as frequency analysis and order tracking.
-
product
S2 Penta High-Sensitivity Sensors
ULP S2 PCI/V HS
The Universal LightProbe S2 Penta High Sensitivity Sensor features the same popular built-in color binning as the regular S2 Penta Sensor, and is designed test extremely dim LEDs, providing an analog output for intensity, ranging from 0 to 4 volts, corresponding to the LED’s luminous intensity in millicandelas. Implemented in a unique and customizable 2-Part solution, the S2 Penta High Sensitivity Sensor is assembled with your choice of Fiber-Optic Probe, including for the test of densely-spaced LEDs, bright LEDs, dim or misaligned LEDs, right-angle LEDs, and more, including the popular “Trident” Fiber-Optic Probes to sequentially test 3 LEDs with a single Sensor.Operating temperature range: 0oC to 70oCPower consumption: Operates between +5 and 28 volts D.C., at 6mA max. Less than 4.75 volts is not recommendedVoltage protection: Withstands up to +40 volts, & reverse polarity to -18 voltsOutput Pins: 4 gold-plated standard wire-wrap pins (0.025 in. sq.)Sensor Size: 0.560 in. dia x 1.38 in. longTypical response times: <1.2s color & intensity outputs simultaneously (the brighter the LED, the shorter theresponse time)Fiber-Optic Probes: Wide Aperture Fiber-Optic Probe recommended