-
Product
P2262A General Purpose Probes
General Purpose Probe
Current Rating (Amps): 3Average DC Resistance lower than (mOhm): 30Test Center (mil): 50Test Center (mm): 1.27Full Travel (mil): 90Full Travel (mm): 2.29Recommended Travel (mil): 67Recommended Travel (mm): 1.70Overall Length (mil): 710Overall Length (mm): 18.03
-
Product
Double IC Optic Node
OX 732
-
Converts even weak Optic Signals to a high quality RF Signal. LED BAR Optic Level Display has been provided for ease of system maintenance. They are best suitable for Analog as well as Digital transmission to maintain BER, MER Characteristics. Green Technology incorporated - Aluminium Housing for maximum heat dissipation.- Frequency 40 ~ 1000 MHz- Optical Wavelength : 1290 ~ 1600 nm- Flatness ±0.75 dB- LED Bar Display for Optic Signal Level- High C/N, CSO & CTB Characteristics- Inward Extruded Aluminium Channels for Maximum Heat Dissipation- High Voltage Surge Protection- -11 dBm Sensitivity- RF O/P at 0 dBm : 110 dBµV
-
Product
7kV, 100 MHz, 2.5 pF, 40 M, Rise Time < 3.5 ns, High Voltage Differential Probe
T3HVD7000-100
Differential Probe
7kV, 100 MHz, 2.5 pF, 40 M, Rise Time < 3.5 ns, High Voltage Differential Probe.
-
Product
ICE 3000 Series
ICE3001
-
This subsystem is an agile filter for the SATCOM frequency band, capable of acting as either a receive or a transmit filter. It enables simultaneous operation of multiple transceivers in extreme cosite environments. The ICE3001 provides multiple poles of RF selectivity to reduce broadband noise, harmonics, and spurious signals for either receive or transmit applications. This filter is a highly integrated design incorporating complete Built-in-Test capability. The design has been qualified for military applications. A dual-mount tray is also available as an option for easy incorporation on your platform. Cost-effective modifications are available on the ICE3001.
-
Product
Elevated 2.65 (75.00) - 6.50 (184.00) High Performance Lead Free Probe
LFRE-25V-6.5
ICT/FCT Probe
Current Rating (Amps): 8Average Probe Resistance (mOhm): 8Test Center (mil): 100Test Center (mm): 2.54Full Travel (mil): 250Full Travel (mm): 6.35Recommended Travel (mil): 167Recommended Travel (mm): 4.24Mechanical Life (no of cycles): 1,000,000Overall Length (mil): 1,300Overall Length (mm): 33.02
-
Product
HPC High Current Probes, 100 – 187 mil (2.54 – 4.75 mm)
HPC
High Current Probe
100 – 187 mil (2.54 – 4.75 mm)
-
Product
High 1.73 (49.00) - 8.00 (227.00) High Performance Bias Ball Probe
POGO-1H-8-S
ICT/FCT Probe
Current Rating (Amps): 6Average Probe Resistance (mOhm): 10Test Center (mil): 75Test Center (mm): 1.91Full Travel (mil): 250Full Travel (mm): 6.35Recommended Travel (mil): 167Recommended Travel (mm): 4.24Mechanical Life (no of cycles): 1,000,000Overall Length (mil): 1,300Overall Length (mm): 33.02
-
Product
Alternate 3.00 (85.00) - 5.70 (162.00) General Purpose Probe
P2664G-4V2S
General Purpose Probe
Current Rating (Amps): 5Average DC Resistance lower than (mOhm): 10Test Center (mil): 100Test Center (mm): 2.54Full Travel (mil): 114Full Travel (mm): 2.90Recommended Travel (mil): 84Recommended Travel (mm): 2.13Overall Length (mil): 895Overall Length (mm): 22.73Overall Length Remark: Tip 1C: 845 mil (21.46 mm) Tip 2R: 935 mil (23.75 mm)
-
Product
30 GHz Differential Probe with 2.92mm Interface
DH30-2.92MM
Differential Probe
Teledyne LeCroy’s DH series 8 to 30 GHz differential probes offer the combination of bandwidth, input range and offset capability to address any high-speed probing requirement from debugging serial data interfaces to validating DDR memory systems. DH series probes provide superior loading characteristics and are calibrated with a custom “fine-tuned” frequency response. The ultra-low loading and flat frequency response ensure accurate measurements.
-
Product
Light 0.75 (21.00) - 2.00 (57.00) High Performance Lead Free Probe
LFRE-25T-2
ICT/FCT Probe
Current Rating (Amps): 8Average Probe Resistance (mOhm): 8Test Center (mil): 100Test Center (mm): 2.54Full Travel (mil): 250Full Travel (mm): 6.35Recommended Travel (mil): 167Recommended Travel (mm): 4.24Mechanical Life (no of cycles): 1,000,000Overall Length (mil): 1,300Overall Length (mm): 33.02
-
Product
Super 3.90 (111.00) - 16.00 (454.00) High Performance Lead Free Probe
LFRE-25T36-16
ICT/FCT Probe
Current Rating (Amps): 8Average Probe Resistance (mOhm): 8Test Center (mil): 100Test Center (mm): 2.54Full Travel (mil): 250Full Travel (mm): 6.35Recommended Travel (mil): 167Recommended Travel (mm): 4.24Mechanical Life (no of cycles): 1,000,000Overall Length (mil): 1,300Overall Length (mm): 33.02
-
Product
8 GHz Differential Probe with ProLink Interface
DH08-PL
Differential Probe
Teledyne LeCroy’s DH series 8 to 30 GHz differential probes offer the combination of bandwidth, input range and offset capability to address any high-speed probing requirement from debugging serial data interfaces to validating DDR memory systems. DH series probes provide superior loading characteristics and are calibrated with a custom “fine-tuned” frequency response. The ultra-low loading and flat frequency response ensure accurate measurements.
-
Product
Pyramid, 3-Sided Chisel 30°, Standard 0.61 (17.00) - 2.80 (79.00) General Purpose Probe
HPA-0T
General Purpose Probe
Current Rating (Amps): 3Average Probe Resistance (mOhm): 35Test Center (mil): 50Test Center (mm): 1.27Full Travel (mil): 100Full Travel (mm): 2.54Recommended Travel (mil): 67Recommended Travel (mm): 1.70Mechanical Life (no of cyles): 1,000,000Overall Length (mil): 635Overall Length (mm): 16.13
-
Product
Cup, Concave 90/120°, Standard 0.61 (17.00) - 2.80 (79.00) General Purpose Probe
HPA-0A
General Purpose Probe
Current Rating (Amps): 3Average Probe Resistance (mOhm): 35Test Center (mil): 50Test Center (mm): 1.27Full Travel (mil): 100Full Travel (mm): 2.54Recommended Travel (mil): 67Recommended Travel (mm): 1.70Mechanical Life (no of cyles): 1,000,000Overall Length (mil): 635Overall Length (mm): 16.13
-
Product
Elevated 1.68 (48.00) - 7.00 (198.00) High Performance Lead Free Probe
LFRE-1I8-7
ICT/FCT Probe
Current Rating (Amps): 6Average Probe Resistance (mOhm): 10Test Center (mil): 75Test Center (mm): 1.91Full Travel (mil): 250Full Travel (mm): 6.35Recommended Travel (mil): 167Recommended Travel (mm): 4.24Mechanical Life (no of cycles): 500,000Mechanical Life Remark: *Ultra High force products may observe slight decrease in cycle life.Overall Length (mil): 1,300Overall Length (mm): 33.02
-
Product
Light 0.83 (24.00) - 2.00 (57.00) High Performance Bias Ball Probe
POGO-1I-2-S
ICT/FCT Probe
Current Rating (Amps): 6Average Probe Resistance (mOhm): 10Test Center (mil): 75Test Center (mm): 1.91Full Travel (mil): 250Full Travel (mm): 6.35Recommended Travel (mil): 167Recommended Travel (mm): 4.24Mechanical Life (no of cycles): 1,000,000Overall Length (mil): 1,300Overall Length (mm): 33.02
-
Product
Light 0.75 (21.00) - 2.00 (57.00) High Performance Lead Free Probe
LFRE-25L36-2
ICT/FCT Probe
Current Rating (Amps): 8Average Probe Resistance (mOhm): 8Test Center (mil): 100Test Center (mm): 2.54Full Travel (mil): 250Full Travel (mm): 6.35Recommended Travel (mil): 167Recommended Travel (mm): 4.24Mechanical Life (no of cycles): 1,000,000Overall Length (mil): 1,300Overall Length (mm): 33.02
-
Product
High 3.12 (88.00) - 8.00 (227.00) High Performance Lead Free Probe
LFRE-72U-8
ICT/FCT Probe
Current Rating (Amps): 3Average Probe Resistance (mOhm): 15Test Center (mil): 50Test Center (mm): 1.27Full Travel (mil): 250Full Travel (mm): 6.35Recommended Travel (mil): 167Recommended Travel (mm): 4.24Mechanical Life (no of cycles): 500,000Overall Length (mil): 1,700Overall Length (mm): 43.18
-
Product
Brute High Current Probe
P4301-1W
High Current Probe
Current Rating (Amps): 50Current Rating Remark: 40 Amps for BeCu plungersAverage Probe Resistance (mOhm): 5Test Center (mil): 300Test Center (mm): 7.62Full Travel (mil): 250Full Travel (mm): 6.35Recommended Travel (mil): 167Recommended Travel (mm): 4.24Mechanical Life (no of cyles): 1,000,000Overall Length (mil): 1,750Overall Length (mm): 44.45
-
Product
Alternate 0.66 (19.00) - 6.00 (170.00) High Performance Bias Ball Probe
POGO-62I8-6-S
ICT/FCT Probe
Current Rating (Amps): 3Average Probe Resistance (mOhm): 15Test Center (mil): 50Test Center (mm): 1.27Full Travel (mil): 250Full Travel (mm): 6.35Recommended Travel (mil): 167Recommended Travel (mm): 4.24Mechanical Life (no of cycles): 500,000Overall Length (mil): 1,300Overall Length (mm): 33.02
-
Product
Elevated 2.65 (75.00) - 6.50 (184.00) High Performance Lead Free Probe
LFRE-25I40-6.5
ICT/FCT Probe
Current Rating (Amps): 8Average Probe Resistance (mOhm): 8Test Center (mil): 100Test Center (mm): 2.54Full Travel (mil): 250Full Travel (mm): 6.35Recommended Travel (mil): 167Recommended Travel (mm): 4.24Mechanical Life (no of cycles): 1,000,000Overall Length (mil): 1,300Overall Length (mm): 33.02
-
Product
Handheld Compact Professional IC Tester
LinearMaster
-
The ABI LinearMaster Compact Professional is a low-cost, hand-held out-of-circuit IC tester. The LinearMaster is designed for testing analogue ICs with up to 16 pins through a ZIF socket (see ChipMaster for digital devices). A range of adapters is also available for SOIC and PLCC devices.
-
Product
Millimeter-wave and Microwave GaAs Specialty ICs
-
Keysight Technologies provides MMIC Specialty ICs ideal for microwave radio, aerospace and defense, and instrumentation applications.
-
Product
Light 0.83 (24.00) - 2.00 (57.00) High Performance Bias Ball Probe
POGO-1V-2-S
ICT/FCT Probe
Current Rating (Amps): 6Average Probe Resistance (mOhm): 10Test Center (mil): 75Test Center (mm): 1.91Full Travel (mil): 250Full Travel (mm): 6.35Recommended Travel (mil): 167Recommended Travel (mm): 4.24Mechanical Life (no of cycles): 1,000,000Overall Length (mil): 1,300Overall Length (mm): 33.02
-
Product
Elevated 2.65 (75.00) - 6.50 (184.00) High Performance Lead Free Probe
LFRE-25L18-6.5
ICT/FCT Probe
Current Rating (Amps): 8Average Probe Resistance (mOhm): 8Test Center (mil): 100Test Center (mm): 2.54Full Travel (mil): 250Full Travel (mm): 6.35Recommended Travel (mil): 167Recommended Travel (mm): 4.24Mechanical Life (no of cycles): 1,000,000Overall Length (mil): 1,300Overall Length (mm): 33.02
-
Product
Standard 0.79 (23.40) - 1.75 (49.60) General Purpose Probe
HPA-40C
General Purpose Probe
Current Rating (Amps): 2Average Probe Resistance (mOhm): 35Test Center (mil): 39Test Center (mm): 1.00Full Travel (mil): 75Full Travel (mm): 1.91Recommended Travel (mil): 50Recommended Travel (mm): 1.27Mechanical Life (no of cyles): 1,000,000Overall Length (mil): 660Overall Length (mm): 16.76
-
Product
High 2.90 (82.20) - 12.60 (357.00) Switch Probe
TSP100-J100-3
Switch Probe
Current Rating (Amps): 5Average DC Resistance lower than (mOhm): 20Test Center (mil): 100Test Center (mm): 2.54Full Travel (mil): 197Full Travel (mm): 5.00Recommended Travel (mil): 157Recommended Travel (mm): 4.00Overall Length (mil): 1,990Overall Length (mm): 50.60Switch Point (mil): 59Switch Point (mm): 1.50
-
Product
DC Coupled Current Probe
34134A
High Current Probe
Measure a wide range of applications with this battery-powered, clamp-on probe; use with DMMs or voltmeters
-
Product
High 1.73 (49.00) - 8.00 (227.00) Bead Probe
BTP-1HL-8
Bead Target Probe
Current Rating (Amps): 6Average Probe Resistance (mOhm): 10Test Center (mil): 75Test Center (mm): 1.91Full Travel (mil): 250Full Travel (mm): 6.35Recommended Travel (mil): 167Recommended Travel (mm): 4.24Mechanical Life (no of cycles): 500,000Overall Length (mil): 1,300Overall Length (mm): 33.02
-
Product
Passive Probe
PP011-1
-
Passive probes are the standard probe provided with most oscilloscopes. Typical passive probes provide a 10:1 attenuation and feature a high input resistance of 10 MΩ. This high input resistance means that passive probes are the ideal tool for low frequency signals since circuit loading at these frequencies is minimized. Passive probes are designed to handle voltages of at least 400V, some as high as 600V. Teledyne LeCroy passive probes feature an attenuation sense pin which tells the oscilloscope to scale the waveforms automatically requiring no user input.Each passive probe is recommended for a certain oscilloscope, using the right passive probe with the right oscilloscope means that the probe will be properly compensated across the entire bandwidth. Using probes with a different oscilloscope will only let you compensate for low frequencies.





























