RF Chambers
isolate and supress RF waves.
See Also: Chambers, TEM Cells, Acoustic Chambers, Altitude Chambers, Anechoic Chambers, Climate Chambers, Dust Chambers, Environmental Chambers, ESS Chambers, Humidity Chambers, Refrigerated Chambers, Reverberation Chambers, Salt Spray Chambers, Sound Chambers, Temperature Chambers, Temperature Humidity Chambers, Thermal Shock Chambers, Vacuum Chambers, RF Enclosures
-
Product
PXI/PXIe RF Multiplexer, Dual 8-Channel, 3GHz, 75Ω, SMB
40-834A-002
-
The 40-834A-002 (PXI) and 42-834A-002 (PXIe) are 75 Ohm 8 to 1 RF multiplexers with 2 banks in a single slot. They have been designed to exhibit low insertion loss and VSWR through the use of modern RF relay technology at an affordable cost. Each MUX has been carefully designed to ensure excellent and repeatable RF characteristics to frequencies of 3GHz with each path having a nominally equal insertion loss.
-
Product
Accelerated Stress Test Chamber
-
CSZ's accelerated stress test chambers combine mechanical refrigeration; LN2 cooling and high velocity air flow for fast product temperature change rates. Chambers are typically designed with a change rate up to 30C (54F) per minute based upon the part temperature. Common uses are production stress testing circuit boards, electronic drives, assemblies, etc. Design allows the user to quickly control and change the temperature of the product.
-
Product
PXI 8x2 RF Matrix 1.5GHz 50 SMB
40-750-511
-
The 40-750-511 is an 8x2 RF Matrix Module suitable for switching frequencies up to 1000MHz. It has a 50Ω characteristic impedance with front panel mounted SMB coaxial connectors. The matrix intended for the easy construction of high performance bidirectional switching systems.
-
Product
PXI/PXIe RF Matrix, 16x2, 300 MHz, 50 Ω MS-M Multiway
42-728A-002
-
The 40-728A-001 (PXI) and 42-728A-001 (PXIe) are 16x2 50 Ω RF matrices with SMB connectors. The 4x-727A/728A/729A range are high density RF matrix modules suitable for switching up to 300 MHz in 50 Ω or 100 MHz in 75 Ω. They are available in 50 Ω or 75 Ω versions with SMB connectors or in 50 Ω versions with a multiway connector.
-
Product
RF Devices that deliver Comprehensive Solutions for Wireless Systems
-
Sumitomo Electric Industries, Ltd.
GaN HEMTs, GaAs FETs , MMICs, and low-noise HEMT solutions offer high performance and uncompromised reliability for radar, base stations, SATCOM, point to point, and space applications.
-
Product
RF Switchbox
-
The RF Switchbox offers the application of a single system consisting of an RF Power Supply (AG 0x13 Generator) and Matching Network Tuner, and distributes power into multiple plasma applications. It allows operation of one source-to-load at a time.
-
Product
PXI Single 16 to 1 RF Multiplexer, 8GHz 50Ω SMA, Terminated
40-883A-002
-
The 40-883A-002 is a single 16 to 1 50Ω RF multiplexer with 8GHz bandwidth and automatic termination of unused signal channels. It is available in 8 to 1 and 16 to 1 configurations in two and three PXI slots respectively.
-
Product
Reference Magnets And Zero Chambers
-
Reference Magnets with different magnetic field strenghts and dimensions. Available field strenghts ranging from 10mT to 1,4T. We deliver the Reference Magnets with a Factory Certificate. Zero Chambers are required to set zero of gaussmeters. We deliver two different types of Zero Chambers.
-
Product
Large Size RF Test Enclosure, ≥100 DB Isolation, 300 MHz - 18 GHz
dbSAFE MAX
-
Some applications require larger test environments. The dbSAFE MAX blends all the superior isolation characteristics of the standard dbSAFE DUO shielded box into a larger volume to guarantee you get better results.
-
Product
GSM/EDGE Analysis Using NI PXI RF Test Instruments
NI-RFmx GSM/EDGE
-
The NI-RFmx GSM/EDGE personality is a highly optimized API for performing physical layer measurements on GSM/EDGE cellular standard signals. NI-RFmx GSM/EDGE is completely interoperable with all NI-RFmx APIs. It provides simple access to the most advanced optimization techniques such as multi-measurement parallelism and multi-DUT measurements. The result is extremely fast and high-quality measurements with minimal software development effort.
-
Product
Single 32 to 1, 50 600MHz PXI RF Multiplexer
40-766-001
-
This 4 to 1 multiplexer is part of a range of RF multiplexers available in the following configurations: dual, quad and octal 4 to 1, single, dual and quad 8 to 1, single and dual 16 to 1 and single 32 to 1. All multiplexers have the option of automatic terminations which offer advantages at system level by reducing the presence of standing waves in the system which can cause degradation in isolation and crosstalk.
-
Product
IEC60529 IPX9K Waterproof Test Chamber
CX-IPX9
-
Shenzhen Chuangxin Instruments Co., Ltd.
The main purpose of the equipment is to test product performance of storage, transportation and use in the rain condition.The equipment, mainly used in electronic and electrical products, lamps ,lanterns, electrical cabinets, electrical components, automobiles, motorcycles and their parts etc, tests physical and other related properties of products by simulating the rain condition.After test, judge if the performance of the product meets the demand by verification for product design, improvement, check and factory inspection use.
-
Product
FieldFox Handheld RF Analyzer, Up To 10 GHz
N9912C
-
Select from cable and antenna analyzer (CAT), Vector Network Analyzer (VNA), and/or Spectrum Analyzer with desired maximum frequency. Capture elusive signals with up to 40 MHz gap-free, real-time bandwidth. Measure all four S-parameters simultaneously with 115 dB dynamic range. Make accurate spectrum analyzer measurements (± 0.3 dB) without warmup. Perform over-the-air measurements for 5G NR and LTE. Use GPS/GNSS for geolocation and timestamping.
-
Product
RF Electronic Calibration Module (ECal), DC/300 KHz To 9 GHz, Type-N, 2 Port
85092D
-
The Keysight 85092D RF electronic calibration (ECal) module makes calibration of vector network analyzers fast, easy, and accurate. ECal is a precision, single-connection calibration technique for your vector network analyzer. Performing a full two-port calibration takes less than half the time and number of connections using ECal versus mechanical calibration kits. Furthermore, the accuracy of the calibration is comparable between electronic and mechanical methods. Traditional mechanical calibrations require intensive operator interaction, which is prone to errors. With ECal, the operator simply connects the ECal module to the network analyzer and the software controls the rest.
-
Product
MS-M Style 26-Pin RF Cable Assembly, Female To Unterminated, 2m, RG316 Cable
40-979-526-3-2m-FU
-
This 2m long MS-M style RF 26-Pin cable assembly is constructed from RG316 Silver Plated Copper Clad Steel Wire with PVC insulation and an attenuation of 68dB/100m at 500MHz. Screwlocks are provided to secure the MS-M style connector to the mating connector.
-
Product
RF Adapter
-
Passive coaxial components that are used to transfer signals from one connector interface to another.
-
Product
SAFEONE® Pro Personal RF Safety Monitor
Pro SI-1100XT
-
SafeOne® Pro SI-1100XT is an effective and economical means to monitor the strength of electromagnetic (RF) fields from mobile phone towers, microwave ovens, radio and television installations, high frequency welders, and other common workplace RF sources between 10 and 18,000 MHz. The Personal RF Monitor is an important tool in complying with FCC, OSHA, and other safe workplace requirements.
-
Product
KEINOS™ 2 MHz 5 KW, 11 KW & 13 KW RF Plasma Generators
-
The KEINOS™ 2MHz plasma generator builds on the solid, reliable attributes of the existing 2MHz design. KEINOS™ incorporates the latest technology from MKS to enable demanding applications of pulsing, fast impedance changes and shorter process steps. KEINOS™ can deliver up to 13kW of power, pulsing up to 50KHz, multiple set point pulsing, pulse shaping and MKS patented frequency tuning. KEINOS™ uses an integrated VI sensor for power accuracy and digital based control for fast response times.
-
Product
PXI/PXIe RF Matrix, 8x4, 300 MHz, 50 Ω SMB With Loop-thru
40-729A-001-L
-
The 40-729A-001-L (PXI) and 42-729A-001-L (PXIe) are 8x4 50 Ω RF matrices with SMB connectors and Y-axis loop-thru. The 4x-727A/728A/729A range are high density RF matrix modules suitable for switching up to 300 MHz in 50 Ω or 100 MHz in 75 Ω. They are available in 50 Ω or 75 Ω versions with SMB connectors or in 50 Ω versions with a multiway connector.
-
Product
RF Solutions for Defense & Space
-
Teledyne e2v HiRel's standard screened line of RF and microwave components provides a cost and time effective approach to meet the requirements commonly found in military and space applications.When system performance or program screening requirements call for more than Teledyne e2v HiRel's standard catalog screened parts, we can tailor a solution by taking a standard catalog device, assembling with proven assembly processes and tailoring a custom screening program that can be created by either adding or removing screening options or by generating a program specific sequence.
-
Product
TSD-101-W Chambers Chambers
-
ESPEC developed the TSD-101-W with an large interior of 28"x16", while strictly limiting the overall size of the system. The footprint is reduced by 40%, as well as lowering power demand by 60% compared to conventional units.
-
Product
Octal 4 to 1 Terminated 50 600MHz PXI RF Multiplexer
40-761-008
-
This terminated octal 4 to 1 multiplexer is part of a range of RF multiplexers available in the following configurations: dual, quad and octal 4 to 1, single, dual and quad 8 to 1, single and dual 16 to 1 and single 32 to 1. All multiplexers have the option of automatic terminations which offer advantages at system level by reducing the presence of standing waves in the system which can cause degradation in isolation and crosstalk.
-
Product
Constant Temperature & Humidity Chamber
DRK-150F
-
Shandong Drick Instruments Co., Ltd.
The constant temperature and humidity chamber has an accurate temperature and humidity control system, which provides various environmental simulation conditions required for industrial research and biotechnology testing, so it can be widely used in sterility tests, stability inspections such as pharmaceuticals, textiles, and food processing.
-
Product
RF Signal/Wireless Camera/Mobile/Bug Detector
SH-055U8 / 01018
-
The RF Signal Detector / Wireless Camera Detector / Mobile Phone Detector / Bug Detector applies digit (numeric) display to show the sensitivity level. With up and down buttons, user knows the sensitivity setting directly
-
Product
2 GHz Dual 1:4 RF Mux, 75 Ohm Module for 34970A/34972A
34906A
-
The Keysight 34906A RF multiplexer module for the 34970A/34972A Data Acquisition/Switch Unit offers broadband switching capabilities for high-frequency and pulsed signals. Use it to route test signals between your device under test and your signal generator, oscilloscope, spectrum analyzer, or other instrumentation. The RF multiplexers are arranged as two independent 1 x 4 multiplexers, each with a common shield and a switched center conductor. Connections can be made directly to SMB inputs with 2 GHz usable bandwidth, or to the BNC-to-SMB adapters provided with 1 bandwidth. Multiple banks may be cascaded together for applications requiring even larger topologies--create a stubless 16:1 multiplexer in a single frame.
-
Product
SP5T RF Pin Diode Switches To 12 GHz
-
Pulsar Microwave's 5-way RF switches cover bands from 300 MHz to 12 GHz in both absorptive and reflective configuration. These SP5T switches have a rating of 200 mW maximum input power and a switching time of 100 ns. They are specified with a minimum isolation of 60 dB and most models maintain a VSWR of 1.6:1 or better on all ports. The SP5T switches are driven by TTL logic control circuitry and require both positive and negative 5-volt supplies for operation. A 9-pin D-SUB connector provides the interface for the power and logic voltages.
-
Product
RF Electronic Calibration Module (ECal), DC/300 KHz To 26.5 GHz, 4-ports
N4433D
-
The Keysight N4433D RF electronic calibration (ECal) module makes calibration of Keysight vector network analyzers fast, easy and accurate. The N4433D is a precision 4-ports ECal module that supports selection of 3.5 mm connector and can be mixed up to 26.5 GHz. Select either female-female, male-male, or female-male connectors.
-
Product
PXI/PXIe RF Matrix, 16x4, 150 MHz, 50 Ω, SMB, With Y Loop-thru
42-724-012-L
-
The 40-724-012-L (PXI) and 42-724-012-L (PXIe) are 16x4 RF matrix modules with y-axis loop-thru and are suitable for switching frequencies up to 150 MHz. Having a 50 Ω characteristic impedance and front panel SMB connectors, these modules provide a simple and scalable bidirectional matrix for RF and are intended for the easy construction of high performance switching systems.
-
Product
Endpoint / Chamber Health Monitor based on Optical Emission Spectroscopy and MWL Interferometry
EV 2.0 Series
-
To address new requirements in Semiconductor, lighting devices, automotive components, flat panels, MEMS sensors, memory chips, and logic electronics processed in the industry using dry etch, cleaning and (PE)CVD, HORIBA has introduced a unique generation of sensor dedicated to Advanced Endpoint Control, Fault Detection and Chamber Health Monitoring.





























