Calibration Services
Adjust test elements to desired specifications.
See Also: Calibration, Services, Calibrators, Power Calibration, Display Calibration, Calibration Standards, Calibration Software, Calibration References
-
Product
Standard Mechanical Calibration Kit, DC To 3 GHz, Type-N, 75 Ohm
85036B
Mechanical Calibration Kit
The Keysight 85036B calibration kit contains precision 75 ohm type-N standards used to calibrate Keysight network analyzers for measurement of devices with 75 ohm type-N connectors. Standards include fixed terminations, open circuits, and short circuits in both genders. This kit is specified from dc to 3 GHz.
-
Product
Calibration Lead Precision Resistor, Triple
40-975-009-SL3
Calibration Lead Cable Assembly
The cable assembly is specifically designed to connect to the 9-Pin D-Type calibration port located on the front panel of Pickering Interfaces Module Part Numbers 40-260, 40-261, 40-262, 40-263 and 40-265.
-
Product
4-in-1 OSLT Mechanical Calibration Kit, DC To 9 GHz
85515A
Mechanical Calibration Kit
The 85515A 4-in-1 mechanical calibration module combines an open, short, load, and through in a compact unit. The product is small, easy to handle, and light weight. The through allows users to easily calibrate non-insertable devices, such as a cable or filter with female-female connectors. During the “thru” part of the calibration, the 85515A through can be used.
-
Product
Mobile Calibration Services
-
Your One-Stop Calibration provider for calibration and instrument services is now even better with our fleet of mobile labs. Trescal is bringing our high-quality precision calibration on the road to make calibrating your equipment as easy and convenient as possible. Our qualified technicians are available across the U.S. to provide the on-site mobile calibration services you need.
-
Product
1 Mm Calibration Kit
85059B
Mechanical Calibration Kit
The Keysight 85059B is a 1.0 mm calibration kit designed for vector network analyzer systems operating over the frequency range of DC to 120 GHz. The opens, shorts and loads in this kit are optimized to provide accurate and traceable calibrations over the specified frequency range. The 85059B with 85059V 1 mm Verification kit are replacements for the 85059A 1 mm calibration/verification kit.
-
Product
Precision Mechanical Calibration Kit, DC To 26.5 GHz, 3.5 Mm
85052C
Mechanical Calibration Kit
The Keysight 85052C precision mechanical calibration kit contains precision standard devices to characterize the systematic errors of Keysight network analyzers in the 3.5 mm interface. This kit also contains adapters to change the gender of the test port and a torque wrench for proper connection.
-
Product
3-in-1 OSL Mechanical Calibration Kit, DC To 50 GHz, 2.4 Mm (m)
85564A
Mechanical Calibration Kit
The 85564A 3-in-1 mechanical calibration standard combines an open, short and load standard in a compact unit. The product is small, easy to handle, and lightweight. All standards in the 85564A are male 2.4 mm.
-
Product
Standard Mechanical Calibration Kit, DC To 7.5 GHz, 7-16
85038A
Mechanical Calibration Kit
The Keysight 85038A calibration kit contains open circuits, short circuits and terminations with both male and female 7-16 connectors and has frequency coverage from dc to 7.5 GHz (usable to 8 GHz).
-
Product
Flexible Cable Set, 3.5 Mm (Test Port) To 7 Mm
85132F
Calibration Cable
The Keysight 85132F is a 62.9 cm (24.75 in) long¹ flexible cable set composed of two 3.5 mm female² to 7 mm connectors. Cable frequency range is dc to 18 GHz with a return loss greater than or equal to 17 dB. Insertion loss is 0.25 * sqrt(f) + 0.2, where f is frequency in GHz, for the test port connector and device connector. Phase stability of semi-rigid/flexible cables is specified with a 90 degree bend using a 4 to 3 inch radius. Stability¹ of the Keysight 85132F is less than 0.12 dB and phase is 0.13 * f + 0.5, where f is frequency in GHz.
-
Product
Economy Mechanical Calibration Kit, DC To 3 GHz, Type-F, 75 Ohm
85039B
Mechanical Calibration Kit
The Keysight 85039B calibration kit, with option M0F, contains male and female type-F open, short, and load standards. This calibration kit works with all 75 ohm network analyzers and test sets for measurement of devices with 75 ohm type-F connectors. The kit also includes type-N to type-F adapters. More economical versions of this kit are available by ordering option 00F for the female standards only, or option 00M for the male standards only. This kit is specified from dc to 3 GHz.
-
Product
4-in-1 OSLT Mechanical Calibration Kit, DC To 18 GHz, Type-N (m) 50 Ohm
85518A
Mechanical Calibration Kit
Easily calibrate non-insertable devices with this module combining an open, short, load, and through in a compact unit
-
Product
Standard Mechanical Calibration Kit, DC To 9 GHz, 3.5 Mm
85033E
Mechanical Calibration Kit
85033E Standard Mechanical Calibration Kit, DC to 9 GHz
-
Product
Mechanical Calibration Kit, 18 To 26.5 GHz, Waveguide, WR-42
K11644A
Mechanical Calibration Kit
The Keysight K11644A calibration kit contains the precision mechanical standards required to calibrate the systematic errors of Keysight network analyzers. This calibration kit has a precision airline for performing the Thru-Reflect-Line (TRL) calibration, the most accurate error-correction technique for coaxial measurements. This kit also contains a commercial calibration certificate, flush short circuit, a precision shim, and fixed termination(s).
-
Product
Linear Measurement Kit
55280A
Mechanical Calibration Kit
The Keysight 55280A Linear Measurement Kit, used with the Keysight 5530 Laser Calibration System, includes the optical equipment needed to measure linear distance (displacement) and velocity. The kit contains a Keysight 10766A Linear Interferometer, two Keysight 10767A Linear Retroreflectors, mounting hardware, andtransit case.
-
Product
Mechanical Calibration Kit, 12.4 To 18.0 GHz, Waveguide, WR-62
P11644A
Mechanical Calibration Kit
The Keysight P11644A calibration kit contains the precision mechanical standards required to calibrate the systematic errors of Keysight network analyzers. This calibration kit has a precision airline for performing the thru-reflect-line (TRL) calibration, the most accurate error-correction technique for coaxial measurements. This kit also contains a commercial calibration certificate, flush short circuit, a precision shim, and fixed termination(s).
-
Product
Calibration Cable, 78-pin D-type, Thermocouple Simulator Modules
40-975-078-1m
Calibration Cable
This cable assembly is specifically designed to connect to the 78-Pin D-Type port on the front panel of Pickering Interfaces Thermocouple Simulator Modules 41-760 and 41-761 enabling calibration via an external DMM.
-
Product
4-In-1 OSLT Mechanical Calibration Kit, DC To 18 GHz, Type-N (f) 50 Ohm
85519A
Mechanical Calibration Kit
Easily calibrate non-insertable devices with this module combining an open, short, load, and through in a compact unit
-
Product
4-in-1 OSLT Mechanical Calibration Kit, DC To 40 GHz, 2.92 Mm (f)
85561A
Mechanical Calibration Kit
Combines an open, short, load, and through standard in a compact unit that is easy to handle and lightweight.
-
Product
Calibration and Measurement Services
-
A uniform light source which provides spatially uniform luminance and illuminance for flat-field correction and calibration imaging systems, calibration photometers and spectroradiometers.
-
Product
Calibration and Repair Services
-
Additel calibrations provide you with high confidence and low uncertainty for your standards. Our accredited calibration laboratory utilizes primary-level piston gauge systems and high-performance controllers to provide services for the entire Additel product line. In addition, our repair technicians which are ready to help, should you have trouble with the Additel units you own.
-
Product
Economy Mechanical Calibration Kit, DC To 3 GHz, Type-N, 75 Ohm
85036E
Mechanical Calibration Kit
The Keysight 85036E economy calibration kit contains precision 75 ohm type-N male fixed termination and a one-piece 75 ohm type-N open/short circuit. These standards are used to calibrate Keysight network analyzers for measurement of devices with 75 ohm type-N connectors. The kit is specified from dc to 3 GHz.
-
Product
Flow Calibration
-
Trescal provides full Flow Calibration services that are accredited and/or certified in accordance with ISO/IEC 17025. Flow Calibration services can be delivered at your site or at our lab. Accreditations for our flow calibration service guarantees calibration results are traceable to the International Systems of units (SI) through NIST or NRC.
-
Product
RFID Sensor Datenlogger (HF)
TELID®300
-
TELID® sensor data loggers are ideal for complex monitoring of quality assurance and maintenance, or while transporting foods, plants, pharmaceuticals or medical products. Temperature, humidity, pressure or shock-sensitive products can be monitored and traced, for example, during worldwide transportation. microsensys offers calibration services for the TELID®311, 311.ac and 314.ac. We carry out a factory (one- to three-point) calibration according to your temperature specifications, which are based on controlled operations and continuous monitoring, or ISO (one- to more point) calibration for temperature according to DAkkS specifications.
-
Product
Standard Mechanical Calibration Kit, DC To 7.5 GHz, 7–16 (male)
85038M
Mechanical Calibration Kit
Modern wireless communication systems require high-performance components offering low VSWR and low intermodulation distortion at high transmit power levels. To meet these needs, 7-16 connectors are becoming increasingly common in base station transmitters, amplifiers, duplexers, and other products. These connectors conform to IEC 169-4, DIN 47223, European standard EN 122190, and British standard BSEN 122190.
-
Product
Services
-
We provide the following systemintegration services: Project design and management, Submittal preparation, AutoCad drawings, Panel design, Panel fabrication, HMI Design, System start-up or commissioning, Maintenance, Troubleshooting
-
Product
Calibrators
-
Portable and user friendly calibrator, ideal for checking sound level meters and dosimeters on the measurement site, or in the laboratory.
-
Product
4-in-1 OSLT Mechanical Calibration Kit, DC To 9 GHz, Type-N(m), 50 Ohm
85514A
Mechanical Calibration Kit
Easily calibrate non-insertable devices with a type-N (m) 50 Ω open, short, load, and through in a compact unit
-
Product
Calibrators
-
Ensure the accuracy and reliability of your leak and flow testing instruments with our cutting-edge calibrator. Specifically designed for precision calibration, our product stands out in the market for its innovative technology and user-friendly features. Ideal for a wide range of industries, this calibrator is essential for maintaining the integrity of your leak and flow testing equipment. With its robust design and exceptional accuracy, our calibrator is a must-have for professionals seeking to uphold the highest standards in leak and flow measurement. Whether you’re in manufacturing, engineering, or quality control, our calibrator is the perfect tool to ensure your instruments are performing at their best. Discover the difference in precision and reliability with our top-tier calibrator for leak and flow testing instruments.
-
Product
Calibrators
-
Electronic Development Labs, Inc.
Your equipment and sensors must function at optimal levels to achieve the results you want—no matter your industry. Engineered by skilled craftsmen to maximum reliability accuracy, EDL calibrators are trusted around the globe—and have been for decades. Your business relies on predictable results that consistently meet quality standards. And EDL has set the standard for calibration.