I²C
A slow Inter-Integrated Circuit bus protocol.
-
Product
NI-9212, 8-Channel, 95 S/s/ch Simultaneous, ±78 mV C Series Temperature Input Module
785259-01
-
8-Channel, 95 S/s/ch Simultaneous, ±78 mV C Series Temperature Input Module - The NI‑9212 offers channel‑to‑channel, isolated thermocouple input channels. The NI‑9212 channel‑to‑channel isolation protects channels from continuous voltages up to 250 Vrms and transient (withstand) voltages up to 1500 Vrms. You can use the NI‑9212 in a variety of applications that are not conducive for bank-isolated channels such as white goods testing, in-vehicle data logging, battery stack testing, as well as in various other noisy industrial environments.
-
Product
Development Board
SOM-DH3000
-
Development Board for COM-HPC® Client pin-out & Size A/B/C Modules. PICMG COM-HPC Client pinout, COM-HPC Size A, B and C compatible. Rich extension: 1 x PCIe x16 (Gen5), 7 x PCIe x4 (Gen5).
-
Product
C+L Band Broadband Light Source
S-103
-
ASE broadband source slot module of FOTS system can offer special function that is able to change optical output spectral feature variously, which is change optical output spectral feature variously, which is followed by user’s driving embedded pump LD freely. The output power of each pump LD is controlled separately by the program that is set up by user. In the case optimum ASE source output features such as wide broadband (> 80 nm @ -10 dBm/nm) and stable output power (< 0.02 dB) is needed, it is made up so that the provided Default mode along with User mode can be chosen and set up. More stable application of ASE source is possible through the combination of monitoring of ASE output power, alarm status and pump LD status with real-time optimal feedback. The embedded FPGA processor makes high speed control possible and enables monitoring and feedback routine operated stably.
-
Product
Anfatec's Humidity Sensor
Humi
-
Temperature sensor: operating range: -40 .. 123.8 °C resolution: 0.01 °CHumidity sensor: operating range: 0 .. 100 %RH (Relative Humidity) resolution: 0.05 %RHPressure sensor: operating range: 300 .. 1100 hpa resolution: 3 hpa user-friendly software
-
Product
NI-9381, 8 AI, 8 AO, 4 DIO, 0 V to 5 V, C Series Multifunction I/O Module
782580-01
-
8 AI, 8 AO, 4 DIO, 0 V to 5 V, C Series Multifunction I/O Module - The NI‑9381 is a single, cost-effective module for general-purpose system I/O. The NI‑9381 combines common I/O circuitry into a single module to help system designers fit more functionality into a single system. The analog circuitry on the NI‑9381 is a multiplexed architecture that shares a single timing engine. The maximum sample rate per channel is divided by the number of both analog input and analog output channels in use. The NI‑9381 is supported in only CompactRIO Chassis.
-
Product
Infrared Thermometer
-
Display: 3 1/2 digit liquid crystal display (LCD) with amaximum reading of 1999.Polarity: Automatic, positive implied, negative polarityindication.Low battery indication: the " " is displayed when thebattery voltage drops below the operating level.Operating environment: 0°C to 50°C at<75% relativehumidity.Storage temperature: -20°C to 60°C, 0 to 80% R.H.withbattery removed from meter.Accuracy: Stated accuracy at 23°C±5°C, <75% relativehumidity.Auto power off : 10 secondsDimensions: 148mm(H) x 105mm(W) x 42mm(D).
-
Product
3 Axis Magnetic Field Meters
-
Display: 4 digits LCD, maximum reading 9999 Range: 20/2000 mG,2/20/200TResolution: 0.1/1 mG or 0 .001/0 .01/0 .1 TAccuracy: (2.5%+5dgt) at 50Hz/60Hz (5.0%+5 dgt) at 30Hz-2000HzSensor: Triple AxisFrequency response: 30Hz to 2000HzOperating temperature & humidity: 5'Cto 40'C, below 80% RHWeight: About 230g
-
Product
Needle Microprobe
MT-4
-
Fast-response 29 gauge needle probe with blunt tip, (needle length is 1cm) for instant readings. Good for instant skin temperature and surface temperatures, liquids. Also for very small specimens, powders and materials. Needle tip is sealed to ensure only stainless steel contacts specimen. Max. temp. 200°C. 5 ft. lead. Smallest microprobes give fastest reading. Short probes are easier to insert and last longer. Type #'s indicate needle gauge and needle length in cm.
-
Product
Dew Point Monitor
DPM-99
-
The NFPA99 has mandated that for Med Gas systems the "dew point for locally compressed air shall be monitored and alarmed per 4-3.1.9.8 and 4-3.1.1.2(f) to protect from line pressure dew point rise to 39 degrees F (3.9 degrees C) from a nominal design of 35 degrees F (1.7 degrees C)." This safeguard was the foundation for the new Edgetech Instruments DPM-99 Med Gas Dew Point Monitor. This specifically designed monitor exceeds the requirements set forth by the NFPA and was a collaboration with AIRVAC Technical Services who are certified by P.IP.E as medical gas inspectors in all 50 US States.
-
Product
cDAQ-9178, 8‑Slot, USB CompactDAQ Chassis
781156-01
-
8‑Slot, USB CompactDAQ Chassis - The cDAQ‑9178 is a CompactDAQ USB chassis designed for small, portable sensor measurement systems. The chassis provides the plug‑and‑play simplicity of USB to sensor and electrical measurements. It also controls the timing, synchronization, and data … transfer between C Series I/O modules and an external host. You can use this chassis with a combination of C Series I/O modules to create a mix of analog I/O, digital I/O, and counter/timer measurements. The cDAQ‑9178 also has four 32‑bit general-purpose counters/timers. You can access these counters, as well as share clocks and triggers, through two built-in BNC connectors.
-
Product
DC/AC Inverter 4000 W
ODS-3000-7177-T
-
DC/AC inverter with 4000 W from Premium | input ranges 77 - 138 VDC | output 230 VAC | operates in temperatures from -25 to +70 °C | approved for EN45545-2 fire and smoke | railway version
-
Product
Airborne Receivers & Bit Synchronizers
-
The Lumistar LS-28-DRSM Series Multi-Mode Multi-Band Receiver/Combiner/TM Processing Unit is designed using ruggedized packaging to survive severe airborne conditions. The LS-28-DRSM is available in several configurations: 1) Airborne receiver only (RF to bits), 2) Airborne bit synchronizer only, 3) RF to TM Processing and Display (RF to bits to UDP decom to LAN Client Displays). Models with receivers are available in any band form 200 MHz to 7 GHz with S, lower L and C bands as standards. Other RF bands are available, please consult the factory for details. This unit can be mated with other Lumistar products to provide a complete air-to-ground re-transmission system.
-
Product
Switch Modules - 8 Single Pole, Form C, Discrete Power Relays which are Wired & Controlled Individually
JX8/KCP
-
This module has 8 single pole, Form C, discrete power relays which are wired and controlled individually. The relays can be externally wired to make any configuration needed. Use as individual A-B relays or use them to drive external relays, solinoids, or any external device. Screw Terminal Connectors and Armature power relay for switching up to 8 Amps of DC or AC current.
-
Product
Broadband Calibrated Noise Sources
-
Fairview Microwave’s calibrated noise sources cover frequency bands from 10 KHz to 18 GHz. Their performance specifications include output ENR levels ranging from 15 dB to 30 dB and typical VSWR levels as low as 1.25:1. Depending on the model, calibrated frequency points are at 10 MHz, 100 MHz, 1000 MHz, 2000 MHz and 1 GHz steps. The temperature coefficient of these noise sources is < 0.01 dB/°C and noise output variation is < 0.1 dB/%V.
-
Product
K Thermocouple Surface Probe
TP772
-
Surface thermocouple Type "K" probe. °C max: 400. Response time: 3 s.
-
Product
Diving Technology Test Systems
-
Ingenieurbüro Dr. Hillger Ultrasonic-Techniques
The imaging ultrasonic testing systems of the USPC 30XX series are optimized for testing a wide variety of materials and provide high-resolution findings in the form of A, B, C, D and F images. The hardware consists of an industrial PC, in which a motor controller and an ADC card are installed, as well as a HILL-SCAN pulser/receiver unit. An overview of the available systems is given in Table 1.
-
Product
Glycerine & Propylene Glycol Refractometer, Freeze Point °C
PA203X-006-009-016-019
-
Celsius model – The Palm Abbe Glycerine & Propylene Glycol Refractometer is designed to provide the freezing point and percent concentration of both glyercine and propylene glycol antifreeze solutons. This instrument will test glycerine and propylene glycol percent concentration by volume and freezing point in degrees Celsius.
-
Product
Centesimal Thermometer Pt100
HD2107.1
-
Centesimal thermometer in the range ±199.99 °C, decimal outside this range, one input for Pt100 probes with SICRAM module measuring range -200 °C +650 °C.
-
Product
Bus Analyzer / Exerciser
PCF650
-
The PCF650 analyzer provides a multitude of functions to help you analyze your system.- Capturing bus activity using sequential triggers and filters- Exerciser to perform memory, I\O and configuration cycles- Stimulus generation for hardware simulation and fault generation- Anomaly detection of protocol and timing violations- Performance analysis of utilization, transfer rates, latency, statistics
-
Product
Passive XMC-to-PCI Express Adapter
5944
-
The Technobox, Inc. P/N 5944 is designed to adapt a single-wide XMC card to a 16X PCI Express slot. The 5944 supports both P15 and P16 and allows access to PN4 signal via the adapter's DIN connector. The A and C rows of a 96-pin DIN connector connect with the 64-pin user I/O connector (J4/P4) on the mezzanine card, permitting internal connection of rear I/O.
-
Product
VME J2 4 slot
101VMEJ204-0900
-
VME J2 backplane 4 slot, compliant with ANSI/VITA 1-1994. The A+C rows are bussed in all slots. Also, row B has onboard, inboard termination.
-
Product
1U Type Power Supply; ATX 270 W
PS270-1U
-
*Input Range: 90 ~ 264VAC Full Range*Output Voltage:**+5V, 18A (0.5A min)**+3.3V, 16A (0.5A min)**+12V1, 16A (1A min)**+12V2, 10A (1A min)**-12V, 0.8A**+5Vsb, 2.5A*MTBF(hours): At 25°C, 100,000h*Safety: TUV, CSA 22.2 NO.60950-1, IEC, UL, NEMKO, CE*Dimensions: 150 x 81.5 x 40.5 mm*Compatible with Axiomtek products: AX61120 / AX60530
-
Product
DCDC
Hua/Hud Series
-
The HUA/ HUD is a cost-effective series of DC/DC converters, offering both single and dualoutputs. These unregulated converters offer the latest in MOSFET technology. Featuring efficiencies to 80%, cool operating case temperatures and a high level of reliability with a MTBF in excess of 1,000,000 hours. Additional standard features include an internal Pifilter, 500 Vdc I/O isolation, up to 12 watts of output power and operating temperature of –25°C to +71°C with no derating. All this in a package measuring 2.0” x 2.0” x 0.40” high.
-
Product
onTAP DLL
-
Whether plugging into a test executive, or running as a plug-in to your own interface, onTAP’s DLL can be linked to and run from third party test executives such as, National Instruments’ LabVIEW™. Flynn Systems provides GUI demo programs written in C++ and C# showing you how to link the onTAP DLL to your test executive
-
Product
MIL-STD-1553 MCH
M4K1553MCH
-
The M4K1553MCH interface module for the multimode, multiprotocol, Excalibur 4000 family of carrier boards provide a complete solution for developing and testing 1553 interfaces and performing system simulation of the MIL-STD-1553 bus. The module handles all standard variations of the MIL-STD-1553 protocol.The M4K1553MCH contains 32k x 16 of dual-port RAM for Data blocks, Control registers, and Look-up tables. All Data blocks and Control registers are memorymapped and may be accessed in real time. The dual-redundant 1553 module may be programmed to operate in one of four modes of operation: Bus Controller, Remote Terminal, RT/Concurrent-Bus Monitor, and Bus Monitor. The M4K1553MCH comes complete with Windows software, and a C driver software library including source code.
-
Product
PXIe-5673E, 6.6 GHz PXI Vector Signal Generator
781340-04
-
6.6 GHz PXI Vector Signal Generator—The PXIe‑5673E is a wide-bandwidth module that, when combined with the appropriate software, can generate a variety of signals. With the Modulation Toolkit for LabVIEW, it can generate different waveforms including AM, FM, CPM, ASK, FSK, MSK, PSK, QAM (4‑, 16‑, 64‑, and 256‑QAM), multitone signals, arbitrary waveforms, and many others. In addition, you can combine these vector signal generators with standard-specific software to generate signals for GPS, GSM/ EDGE/WCDMA, WLAN, WiMAX, DVB‑C/H/C, ISDB‑T, ZigBee, and others. With PXIe‑5673E stream‑from‑disk capabilities, you can generate continuous waveforms that are up to several terabytes in length.
-
Product
Crossed-Roller Bearing Linear Stage ,13mm Travel XY,Sensitivity 1um
NFP-2461
-
Model: NFP-2461 Crossed-Roller Bearing Linear Stage ,13mm Travel XY,Sensitivity 1umDetails&Spec: Please refer to NFP-1461 Specification,It is combinated by2pcs NFP-1461(C,SR,SL
-
Product
MIL-STD-1553 A / B Test And Simulation 3U PXI Module
PXI-C1553
-
*Dual redundant*1, 2 or 4 channels*Simultaneous bus controller, 31 remote terminals, bus monitor*Error entry and detection*FPGA based hardware architecture*PXI trigger on 1553 bus events*10 programmable, discrete I / O (up to 30V)*IRIG-B timecode encoder / decoder with free-running mode*Real-time recording and physical bus playback*Supports: C, C ++, C # and .net*Driver support: Windows, Linux, LabView Real-Time and other systems
-
Product
cRIO Modules
-
The cRIO technology (RIO = reconfigurable I / O) from National Instruments enables the creation of customized measurement and control hardware circuits based on FPGA chips using the NI LabVIEW graphic development tool. The cRIO core comprises an FPGA chip and surrounding circuits that allow LabVIEW to perform a hardware synthesis.
-
Product
SparkFun Qwiic Thermocouple Amplifier
MCP9600 (Screw Terminals)
-
The MCP9600 Breakout is a high accuracy Thermocouple Amplifier equipped with an I2C interface, accessed over our Qwiic system. Inside the chip are two temperature sensors, one for the thermocouple itself (the hot junction) and one for the chip itself (the cold junction). As a result, the MCP9600 can read both the ambient temperature and the temperature of whatever you're trying to measure! The MCP9600 can do both with a resolution of 0.0625°C, and an accuracy of ±1.5°C (worst-case). The MCP9600 Thermocouple Amplifier is one of our many Qwiic compatible boards! Simply plug and go. No soldering, no figuring out which is SDA or SCL, and no voltage regulation or translation required!