Coaxial Switches
Route RF offering excellent signal repeatability and isolation.
See Also: Switches, Membrane Switch, Crossbar, High Voltage Switching, Fiber Optic Switching, Microwave Switching, Optical Switch
-
product
PXI Single Transfer Switch 18GHz 50Ω SMA
40-782-521
The 40-780 Microwave switching module consists of one, two, three or four changeover switches capable of switching frequencies to 18GHz (optionally to 67GHz) in 50Ω or 2.5GHz in 75Ω. The 40-782 module consists of one or two microwave transfer switches. It has a characteristic impedance of 50Ω and is available in versions with maximum operating frequencies of 18GHz, 26.5GHz or 40GHz.
-
product
LXI Microwave Switch, 50Ω 5xSP6T Terminated & 7xSPDT 18GHz SMA
60-890-001
Model 60-890-001 is a mixed configuration Microwave Switch and is suitable for switching 50Ω signals up to 18GHz. With 5 banks of terminated SP6T and 7 banks of SPDT unterminated relays it is ideal for constructing complex microwave switching systems for many applications. Connection is by high performance front panel mounted SMA connectors.
-
product
PXI Microwave Transfer Switch, Single, 26.5GHz, 50Ω, SMA
40-782B-531
The 40-782B-531 (PXI) and 42-782B-531 (PXIe) single transfer switches are part of our range of PXI microwave switching modules. They have a characteristic impedance of 50Ω and a maximum operating frequency of 26.5GHz. Connections are made via front panel mounted high quality SMA coaxial connectors.
-
product
Switch Modules - 16 Single Pole Relays Arranged as an 8x2 Matrix
JX16/AB-1
This module has 16 single pole relays arranged as an 8x2 matrix as shown in the figure to the left. The matrix may be operated and wired individually for up to 16 8x2's per chassis, or jumpered to the backplane to form up to a 128x2 matrix. It is available with Type S or M reed relays for high speed, long life application. These modules are usually used for 2 wire testing where high and low meter leads must be switched between any two points. Often used for 2 wire LCR meter measurements, cable testing, or open / short testing in a variety of applications.
-
product
Switch Modules - 16 Single or Two Pole Relays Arranged as Four Separate 4x1 Multiplexers
JX16/4(4x1)-1 and -2
This module has 16 single or two pole relays arranged as four separate4x1 multiplexers as shown in the figure. The muxes may be operated and wired individually for up to 64 4x1"s per chassis, or jumpered together to form 8x1"s or 16x1"s or jumpered to the backplane to form up to a 256x1 mux or two 128x1 muxes. It is available with Type S, M or LT reed relays.
-
product
High 1.80 (51.00) - 12.60 (357.00) Switch Probe
TSP138-FK400-3
Current Rating (Amps): 10Average DC Resistance lower than (mOhm): 20Test Center (mil): 138Test Center (mm): 3.50Full Travel (mil): 197Full Travel (mm): 5.00Recommended Travel (mil): 157Recommended Travel (mm): 4.00Overall Length (mil): 1,760Overall Length (mm): 44.70Switch Point (mil): 67Switch Point (mm): 1.70
-
product
PXI/PXIe MEMS Optical Switch, Dual Insert/Bypass, Single-Mode, 9/125 Fiber, FC/PC Connectors, With Interlock
42-860A-122-HI
The 40/42-860A-122-HI is a PXI/PXIe dual insert/bypass switch with FC/PC connectors, includes hardware interlock and is part of Pickering's range of PXI Fiber Optic MEMS Switching modules.
-
product
PXI 10A Fault Insertion Switch 6-chan 2-bus
40-192-012
This PXI fault insertion switch uses solid state switching elements and is capable of switching current up to 10A. It is designed to be able to insert three different fault conditions between the test fixture and the equipment under test: Open-Circuit. Short-Circuit between UUT connections. Short-Circuit to external signals. Through relays on each channel enable signals to the UUT to be set open-circuit. Fault Insertion Buses allow any channel to be shorted to any other channel and also enable any channel to be connected to an external signal such as Power, Ignition or Ground to simulate fault conditions. The module is supplied with 2 fault buses.
-
product
High-Density PXI Multiplexer Switch Modules
This range of High-Density Multiplexer Switch Modules provides a compact array of MUX solutions with differing combinations of channel counts and poles. Most of our high-density solutions include isolation relays that allow the MUX to be disconnected from the single input/output port, enabling the convenient interconnection of other channels.
-
product
PXI Dual SPDT RF Switch 6GHz 50 SMA Terminated
40-880-001
A range of 50Ω SPDT RF switching with automatic termination of unused signals. Available as a dual switch in a 1 slot PXI module, a quad switch in a two slot PXI module or hex and octal switches in three slot PXI modules.
-
product
PXI Hex SPDT RF Switch 3GHz 50 MCX
40-870-106
The 40-870 is a 50 RF Switch available with 3 or 6 separate SPDT relays in a single PXI slot. Both versions exhibit low insertion loss and VSWR through the use of modern RF relay technology at an affordable cost. The switch banks been carefully designed to ensure excellent and repeatable RF characteristics to frequencies of 3GHz. The injection of noise and unwanted signals into the signal paths of the 40-870 has been minimized by careful attention to the mechanical and electrical design.
-
product
PXI Dual 2 x 2 Fibre Optic (M Mode) SC M62.5
40-860-222-M62.5
Pickering PXI Fiber Optic MEMS Switching cards are available in many high density formats with a choice of 5 different connector styles to suit most applications: FC/APC (for optimal performance), FC/PC and SC/PC for general applications and LC and MU for high density applications. Fiber optic multiplexers create a signal path by redirecting the optical signal into a selected output fiber. This is achieved using Micro-Mechanical Mirrors driven by a highly precise mechanism and activated via an electrical control signal.
-
product
Alternate 1.10 (31.18) - 7.20 (204.00) Switch Probe
TSP100-F180-2
Current Rating (Amps): 5Average DC Resistance lower than (mOhm): 20Test Center (mil): 100Test Center (mm): 2.54Full Travel (mil): 197Full Travel (mm): 5.00Recommended Travel (mil): 157Recommended Travel (mm): 4.00Overall Length (mil): 1,990Overall Length (mm): 50.60Switch Point (mil): 59Switch Point (mm): 1.50
-
product
PXI/PXIe MEMS Optical Switch, Triple Insert/Bypass
40-860A-332
The 40/42-860A-332 is a PXI/PXIe triple insert/bypass switch with MU connectors and is part of Pickering's range of PXI Fiber Optic MEMS Switching modules. They are available in many high density formats with a choice of different connector styles to suit most applications: FC/APC (for optimal performance), FC/PC and SC/PC for general applications and LC and MU for high density applications. They are also available with an optional hardware interlock which, when activated, will return all optical switches to their default unpowered state.
-
product
PXIe Flexible Microwave Module, Dual SP4T Terminated 40 GHz, Single SPDT 40 GHz, 50 Ω, SMA
42-890-002
The 40-890 (PXI) and 42-890 (PXIe) range of PXI microwave modules allows users to specify the mix of relay types, frequencies and quantities based on the application requirements within the capabilities of the module driver card. Choose from the extensive relay selection already available in the Pickering microwave range to create a flexible solution.
-
product
PXI Triple SPDT RF Switch SMB 75 Ohm
40-830-003
The 40-830-003 is a 75Ω RF Switch with 3 separate SPDT relays in a single PXI slot. It has been designed to exhibit low insertion loss and VSWR through the use of modern RF relay technology at an affordable cost. The switch banks have been carefully designed to ensure excellent and repeatable RF characteristics to frequencies of 3GHz with each path having a nominally equal insertion loss.
-
product
PXIe Flexible Microwave Module, Dual SP4T 40 GHz, Single SPDT 40 GHz, 50 Ω, SMA
42-890-001
The 40-890 (PXI) and 42-890 (PXIe) range of PXI microwave modules allows users to specify the mix of relay types, frequencies and quantities based on the application requirements within the capabilities of the module driver card. Choose from the extensive relay selection already available in the Pickering microwave range to create a flexible solution.
-
product
PXIe Flexible Microwave Module, Dual SP6T Terminated 26.5 GHz, Single SPDT 26.5 GHz, 50 Ω, SMA
42-890-004
The 40-890 (PXI) and 42-890 (PXIe) range of PXI microwave modules allows users to specify the mix of relay types, frequencies and quantities based on the application requirements within the capabilities of the module driver card. Choose from the extensive relay selection already available in the Pickering microwave range to create a flexible solution.
-
product
PXI Single 2 x 2 Fibre Optic (M Mode)SCM62.5
40-860-212-M62.5
Pickering PXI Fiber Optic MEMS Switching cards are available in many high density formats with a choice of 5 different connector styles to suit most applications: FC/APC (for optimal performance), FC/PC and SC/PC for general applications and LC and MU for high density applications. Fiber optic multiplexers create a signal path by redirecting the optical signal into a selected output fiber.
-
product
TSP100 Switch Probes
Current Rating (Amps): 5Average DC Resistance lower than (mOhm): 20Test Center (mil): 100Test Center (mm): 2.54Full Travel (mil): 197Full Travel (mm): 5.00Recommended Travel (mil): 157Recommended Travel (mm): 4.00Overall Length (mil): 1,990Overall Length (mm): 50.60Switch Point (mil): 59Switch Point (mm): 1.50
-
product
PXI Solid State Switch Module, 6xSPST, 10 A
40-182A-011
The 40-182A-011 has 6 off high current SPST switches in two PXI slots and is part of our range of high power solid state switching solutions. Each SPST switch uses a fully isolated solid state relay which has been designed to offer fast operation under hot switching conditions and high inrush current with no operational life degradation. Each SPST switch can support 10A of continuous current and switch up to 200V signals. The switch can sustain inrush currents in excess of 50A. AC or DC signals can be switched since the switch is polarity insensitive.
-
product
Push-Back & Push-Back Switch Probes
Connector assembly check - extreme spring force - used in test modules.
-
product
PXI/PXIe RF Switch, Triple SPDT, 3GHz, 50Ω, SMB
42-870A-003
The 40-870A-003 (PXI) and 42-870A-003 (PXIe) are 50Ω RF switches with 3 separate SPDT relays in a single slot. They have low insertion loss and VSWR through the use of modern RF relay technology at an affordable cost.
-
product
PXI Single Microwave Transfer Switch 26.5GHz 50 SMA
40-782A-531
The 40-782A-531 is a single transfer switch and is part of our range of PXI microwave switching modules. It has a characteristic impedance of 50Ω and a maximum operating frequency of 26.5GHz. Connections are made via front panel mounted high quality SMA coaxial connectors.
-
product
Standard 2.90 (82.20) - 5.40 (153.00) Switch Probe
TSP157-H200-1
Current Rating (Amps): 10Average DC Resistance lower than (mOhm): 20Test Center (mil): 157Test Center (mm): 3.99Full Travel (mil): 197Full Travel (mm): 5.00Recommended Travel (mil): 157Recommended Travel (mm): 4.00Overall Length (mil): 984Overall Length (mm): 25.00Switch Point (mil): 67Switch Point (mm): 1.70
-
product
PXI Microwave Transfer Switch, Dual, 26.5GHz, 50Ω, SMA
40-782B-532
The 40-782B-532 (PXI) and 42-782B-532 (PXIe) dual transfer switches are part of our range of PXI microwave switching modules. They have a characteristic impedance of 50Ω and a maximum operating frequency of 26.5GHz. Connections are made via front panel mounted high quality SMA coaxial connectors.
-
product
PXI/PXIe RF Switch, Triple SPDT, 3GHz, 75Ω, MCX
42-830A-103
The 40-830A-103 (PXI) and 42-830A-103 (PXIe) are 75Ω RF switches with 3 separate SPDT relays in a single slot. They have been designed to exhibit low insertion loss and VSWR through the use of modern RF relay technology at an affordable cost. The switch banks have been carefully designed to ensure excellent and repeatable RF characteristics to frequencies of 3GHz with each path having a nominally equal insertion loss.
-
product
PXI/PXIe Microwave Transfer Switch, Single, 40 GHz, 50 Ω, SMA-2.9, Failsafe
42-782B-541
The 40-782B-541 (PXI) and 42-782B-541 (PXIe) single failsafe transfer switches are part of our range of PXI microwave switching modules. They have a characteristic impedance of 50 Ω and a maximum operating frequency of 40 GHz. Connections are made via front panel mounted high quality SMA-2.9 coaxial connectors.
-
product
PXIe Microwave Transfer Switch, Single, 26.5 GHz, 50 Ω, SMA, Failsafe, Remote Mount
42-782B-531-E
The 40-782B-531-E (PXI) and 42-782B-531-E (PXIe) single failsafe transfer switches with remotely mounted relays are part of our range of PXI microwave switching modules. They have a characteristic impedance of 50 Ω and a maximum operating frequency of 26.5 GHz. Connections are made via front panel mounted high quality SMA coaxial connectors.
-
product
High 1.80 (51.00) - 12.60 (357.00) Switch Probe
TSP138-FK230-3
Current Rating (Amps): 10Average DC Resistance lower than (mOhm): 20Test Center (mil): 138Test Center (mm): 3.50Full Travel (mil): 197Full Travel (mm): 5.00Recommended Travel (mil): 157Recommended Travel (mm): 4.00Overall Length (mil): 1,760Overall Length (mm): 44.70Switch Point (mil): 67Switch Point (mm): 1.70