Process Calibrators
Assure process control signal validity.
-
Product
Process Analyzers
2060
-
The 2060 Process analyzer enables customized online monitoring of industrial processes with multiple parameters and streams. The 2060 Process Analyzer is the most versatile analyzer in the Metrohm Process Analytics product portfolio. With a variety of techniques, the analyzer enables 24/7 online monitoring of critical chemical parameters in industrial processes and wastewater streams.
-
Product
Temperature Calibration
-
In our temperature lab we have the capability calibrate a wide range of temperature products such as catering food probes from deli to restaurant, industrial systems for manufacturing and quality checks using thermocouples surface probes or insertion probes we also calibrate IR (Infrared) thermometers.
-
Product
Horizontal Calibration Instruments (Lab)
THV
-
The horizontal THV instrument has been designed for calibration and certification of gauging equipment of small dimension. It allows easy and precise checking of plug gauges, ring gauges, thread plug gauges, test and dial indicators as well as measuring of high precision production parts.
-
Product
Multi-Point Calibrator
AQMS-200
-
FPI AQMS-200 dynamic dilution calibrator utilizes two mass flow controllers to perform standard zero and span calibration with up to 4 gas sources.
-
Product
Calibration Segment Arm
-
A torque analyzer or a torque sensor are a finely tuned instrument designed for testing and monitoring torque applications. In order to maintain accuracy, it is crucial that torque measuring equipment be properly calibrated regularly. Segment arm is engineered for calibrating torque analyzers and sensors and ensuring instruments are traceable to National or International Standards, such as N.I.S.T and ISO.
-
Product
Calibration Kit
WR-12
-
This precision calibration kit contains a flush short, offset piece and broadband load which allows for a full 12-term port calibration.
-
Product
Calibrators
-
Thermocouple temperature calibrator is capable of measuring and simulating up to 8 types of thermocouples (J, K, T, E, R, S, B, N), as well as a voltage in mV.
-
Product
Calibration Light Source
CAL2
-
Image Engineering GmbH & Co. KG
The CAL2, based on our 22 channel spectrally tunable iQ-LED source, can be adapted for use in many different areas.
-
Product
Electrical Calibration
-
Multifunction and special calibrators for electrical laboratories. All Meatest calibrators support computer assisted automated calibration to save your time.
-
Product
Sound Level Meters & Calibrators
-
A sound level meter, also known as sound pressure level (SPL), decibel (DB) meter, noise meter or noise dosimeter is mainly used for measuring sounds travelling through air. It is used to test noise or sound levels by evaluating sound pressure. It uses a microphone to capture sound and the sound is then evaluated in the device. It is commonly used to prevent loud noises to create a better work environment.
-
Product
Color Calibration & Profiling
-
For both amateurs and professionals photographers, filmmakers, designers, premedia and printing operators achieving predictable results from capture to output can be a challenge. Color Perfectionists turn to X-Rite for affordable, professional, quality calibrating and profiling solutions that make sure all of your devices monitors, projectors, cameras, scanners, printers and mobile devices are speaking the same language.
-
Product
Calibration With Traceability
-
SKF Condition Monitoring Center
SKF Quality Technology has an established global calibration network for waviness, form and vibration measurements. The QT vibration calibration system complies with the international DANAK and DPLA standards.
-
Product
Calibration And Verification Instruments
-
The system of automatic calibration and verification consists of a computer of the operator's workplace and a control controller with a calibrator connected to it and a verified device. The device under test can have 4 to 16 working channels with a complicated circuit for connecting different types of signals: voltage, current, thermocouples, thermoresistance. The system allows a change in the set of operating ranges during calibration and calibration. The software development system used the LabVIEW development environment with the Real-Time module.
-
Product
Pressure Calibrators
-
Wherever you need to work and whatever pressure range you need to work with, our broad selection of tools will meet your needs. From pneumatic or hydraulic deadweight testers and test pumps to electronic deadweight testers, bench controllers, and precise analog pressure gauges, we have you covered at the bench. Going into the field? Fluke’s portable pressure calibrators – with or without pumps and intrinsically safe or not – work with gases or liquids, source and measure, power transmitters, and cover a wide range. With individually available pressure modules, our portable and bench solutions cover pressures from vacuum to 10,000 psi.
-
Product
Process Control Actuators
SM-1700/SM-5000
-
The SM-1700/5000 Series of rotary actuators are internally geared to produce up to 12,500 ft.lbs. (16,950 Nm) of torque, and offer continuous modulation. They are ideally suited for dampers, vanes, valves and other process control applications requiring exact positioning control.
-
Product
Process Purity Oxygen Analyzer
GNL-IN84
-
Shanghai ChangAi Electronic Science & Technology Co.,Ltd
GNL-IN84 high purity oxygen analyzer breaks through magneto mechanical measurement and achieves to measure oxygen concentration without benchmark gas by adopting vast-contract with the world advanced technology as measurement principle. It has observable characteristics of long calibrating period, high precision, small appearance, low power consumption, etc. - See more at: http://en.ci-ele.com/2d52147a-f981-5670-12e2-94734366ad09/5cb96e1c-9d46-71b5-defc-db00e268d683.shtml#sthash.hTZMaZ9i.dpuf
-
Product
IO-Link Process Sensors
-
*Pressure sensors for the detection of the system pressure in machinery and plant*Reliable monitoring of liquids and gases in pipes*Level and limit level monitoring on tanks and containers*Temperature sensors with high precision over the whole temperature measurement range*Devices with clearly visible LED display with alternating red-green indication
-
Product
Large Bargraph Process Display
PRO-BAR Series
-
50-segment bar graph meter with 250 mm (10") scale length for 4-20 mA, 0-1 mA, 0-10V, or 1-5 V signals. Available for vertical or horizontal mounting. Large bargraph is viewable over long distance in industrial environments.
-
Product
Pressure/Vacuum Calibrators
-
Compact, completely self-contained unit designed for calibrating and testing pressure gauges, transducers, pressure switches, and other pressure-sensitive instruments up to 2,000 psi with an accuracy of ±0.25% of full scale.
-
Product
Partial Discharge Calibrator
TPK-H
-
The high voltage-resistant Partial Discharge calibrator is used to determine the correction factor in the PD test circui.
-
Product
Process Systems And Integration
-
For 50 years, Anton Paar has been pushing the limits in process sensor technologies, providing superior products in the fields of density, viscosity, O2, CO2, and refractive index measurement for a wide range of industries, including the beverage, chemical and petroleum industries. Now Anton Paar extends its product portfolio by offering complete process engineering solutions.
-
Product
RF Electronic Calibration Module (ECal), DC/300 KHz To 9 GHz, 7mm, 2 Port
85091D
-
The Keysight 85091D RF electronic calibration (ECal) module makes the calibration of vector network analyzers fast, easy, and accurate. ECal is a precision, single-connection calibration technique for your vector network analyzer. Performing a full two-port calibration takes less than half the time and a number of connections using ECal versus mechanical calibration kits. Furthermore, the accuracy of the calibration is comparable between electronic and mechanical methods. Traditional mechanical calibrations require intensive operator interaction, which is prone to errors. With ECal, the operator simply connects the ECal module to the network analyzer and the software controls the rest.
-
Product
Electrical Calibration
GF6018A
-
Beijing GFUVE Electronics Co.,Ltd.
The equipment is compliance with national verification regulation: JJG1242005 "Ammeter, voltmeter, power meter and resistance meter verification rules" and related national standards. 0.05 single-phase AC/DC standard source, can verify magnitude 0.2 and the following AC/DC voltmeter, ammeter, frequency meter, resistance meter. The source signals by using DSP and 16-bit high-speed analog-to-digital converters of controllable sine wave, the distorted wave signal source.The equipment comes with RS-232 interface, can be connected with PC to a semi-automatic verification system. It has precise interface and multi-functions including verification, storage and query.The equipment adopts color LCD screen, chart character display is clear, with high precision, stable and reliable, convenient operation and flexible characteristics.
-
Product
Calibrating Equipment
-
Stability DC : < 0.01 %FS / 3 min, AC : < 0.02 %FS / 3 minRipple : < 0.2 %Power Supply : 230 VAC, 50 (60) HzPower Consumption : < 250 VAOperating Temperature : 5ºC to 35ºCRelative Humidity : ≤ 80 %Distortion : < 0.5 %Display : 51/2 Digit LED Digital DisplayStep adjustment of Output Signal : 100 %FS / N, 10 %FS / N,%FS / N, 0.1 %FS / N (N = 4, 5, 6, 10 and 15)Dimensions : 190mm (H) x 480mm (W) x 545mm (D)Total Weight : 22.5 kgs (approx.)
-
Product
Pressure Calibration
-
We make pressure calibration easy! All you have to do is hand us over your gauge or meter! We’ll look after the rest, half inch, quarter inch, brass or steel fitting, we have the adapters to make it work.
-
Product
Infrared Video Processing
-
*Edge Enhancement improves the apparent sharpness of an image by boosting the contrast of edges in the imagery *Electronic Image Stabilization compensates for jitter in a video sequence, providing stabilized video output and remaining responsive to intentional user panning*Auto-Focus automatically adjusts the lens focus to its optimal in-focus position *Electronic Zoom uses interpolation to produce an enlarged image on the video display *Non-Uniformity Correction compensates for detector-to-detector non-uniformity to provide a well-calibrated image output
-
Product
Robot Calibration
-
Achieve improved absolute robot positioning accuracy via dynamic robot calibration using API’s Laser Tracker and Active Target a self-orienting motorized 360° rotation SMR.
-
Product
Broadband Calibrated Noise Sources
-
Fairview Microwave’s calibrated noise sources cover frequency bands from 10 KHz to 18 GHz. Their performance specifications include output ENR levels ranging from 15 dB to 30 dB and typical VSWR levels as low as 1.25:1. Depending on the model, calibrated frequency points are at 10 MHz, 100 MHz, 1000 MHz, 2000 MHz and 1 GHz steps. The temperature coefficient of these noise sources is < 0.01 dB/°C and noise output variation is < 0.1 dB/%V.