Resistance Calibrators
-
Product
Seismic Transducers Calibration System
-
Calibration of the seismic sensors should be conducted in the low-frequency domain, which means, that the relative method used for calibration of the vibration transducers is not applicable since it does not guarantee the required accuracy level. The problem is that the reference accelerometers have uneven AFR characteristic in the low-frequency domain. Thus, calibration of seismic transducers requires implementation of a different approach.
-
Product
Velocity Calibration
-
Trescal provides full Velocity Calibration services that are accredited and/or certified in accordance with ISO/IEC 17025. Velocity Calibration services can be delivered at your site or at our lab. Accreditations for our velocity calibration service guarantees calibration results are traceable to the International Systems of units (SI) through NIST or NRC.
-
Product
Contact Resistance Meter
CRM 100C
-
CRM 100C directly measures resistance values with DC current injection under live switchyard conditions.The CRM 100C is specially designed to reliably measure contact resistance of Circuit Breakers, Isolators, Bus Bar joints, welded joints etc., under the hostile electrostatic noise found in live EHV switchyards. It can also be used for testing cables, graphite bars etc.
-
Product
Temperature Calibration Equipment
-
We offer wide line of temperature calibration equipment for calibration of contact type sensors (Baths/furnaces) and non contact type sensors (Black Bodies), available in temperature range -80°C to 1700°C.
-
Product
Resistance Temperature Detectors (RTD) Simulators
-
Simulation of resistance based temperature sensors such as positive or negative temperature coefficient thermistors. Resistance Temperature Detectors (RTDs) can be wire-wound or thin film. Our RTD simulator modules provide a cost-effective method of simulating both PT100 and PT1000 RTD sensor types that require fine setting resolution.
-
Product
Calibration Management Software
MET/CAL®
-
MET/CAL software is structured around the flow of instruments through the calibration process and addresses a wide range of test and measurement instrument calibration needs, from the simple to the complex. It is based on the traditional calibration model as its framework—comparing an instrument to a standard of known uncertainty.
-
Product
Temperature Calibration
-
Process Instruments maintains primary temperature standards for the calibration of Standard Platinum Resistance Thermometers. SPRT''s are measured against a Thomas-type Ten Ohm Standard Resistor (a Leeds & Northrup 4211-B), using a Measurements International automated bridge. Primary thermometry points are maintained at the Water, Tin, Zinc and Gallium points.
-
Product
Resistance Wire Bonding
-
Electronic Systems of Wisconsin, Inc.
ESW's Resistance Wire Bonding System comes equipped with the latest features the market has to offer. Our system is capable of bonding armatures, stators or coils. The on-screen display in our bonder makes it easy to read, track, and record your bonding data. If desired, ESW offers complete electrical testing of the part prior to the bonding sequence as well. This ensures only good parts that have been electrically tested are processed through bonding. It is our duty to make sure you never have to worry about losing important information again. Our Sales and Engineering staff will work closely with you to make sure that a bonding systems will meet your needs. See the slideshow below to see some of our Resistance Wire Bonding Testers.
-
Product
Onsite Calibration Services
-
Tempsens offers NABL Accrediated on-site calibration i.e. calibration of temperature sensors at customers plant or site.Our experienced and trained Engineers visit site or plant as scheduled by our customer to calibrate the instruments, usually without the time and expense of removing and reinstalling them. Work is performed with minimal disruption, and detailed documentation is provided upon completion.
-
Product
ATE / Bench Calibrators & Multimeters
-
Time Electronics offer a range of precision calibrators and digital multimeters that can be used in the lab or in automated testing applications. These programmable instruments are designed for precision, performance, and functionality, making them ideal for automatic testing and fault diagnosis. Each designated ATE calibrator is rack mountable for straightforward integration into user systems.
-
Product
Transformer Resistance Testing
-
Transformer insulation resistance deterioration is one of the most common causes of transformer failure: a failing transformer is a costly replacement in an electrical system with the potential for a long downtime. If you fail to maintain your transformer with regular insulation resistance testing (as can be carried out by the Megger Transformer Ohmmeter (MTO) series of transformer test equipment) then it’s likely to fail before reaching its maximum operating life.
-
Product
AC Load Bank (Resistive)
K-1000 Resisitive
-
Kongter Test & Measurement Co., Limited
The kW of a resistive load bank is “real” power in electrical terms. When a resistive AC load bank is used to test an engine generator set the engine will produce its full horsepower rating, dissipate engine exhaust gases, and produce thermal energy into the engine cooling system. The resistive load bank in fact, will completely test the engine and its various systems.
-
Product
Broadband Calibrated Noise Sources
-
Fairview Microwave’s calibrated noise sources cover frequency bands from 10 KHz to 18 GHz. Their performance specifications include output ENR levels ranging from 15 dB to 30 dB and typical VSWR levels as low as 1.25:1. Depending on the model, calibrated frequency points are at 10 MHz, 100 MHz, 1000 MHz, 2000 MHz and 1 GHz steps. The temperature coefficient of these noise sources is < 0.01 dB/°C and noise output variation is < 0.1 dB/%V.
-
Product
Calibration Services
-
API Measurement Services offer on-site machine tool and industrial robot calibration and volumetric error correction services. Laser trackers can be calibrated at our calibration laboratories or accuracy certified in the field. A2LA ISO 17025 certified.
-
Product
High Resistance Neutral Grounding Devices
-
HRG systems limit the fault current by placing high resistance between neutral point of transformer (or generator) and ground. As it is not possible to locate the fault point in delta connected systems, an artificial neutral point is created and delta connected system can be grounded. This allows a fault current of a few amperes thus locating the fault point gets easy. When the neutral point is grounded thru high resistance, both continuity of operation is provided during fault condition and sufficient current (typically between 2 A and 10 A) flow is provided for ease of locating the fault point.
-
Product
Super Silicon Resistivity and Type Tester
HS-3FC II
-
Super Silicon Resistivity and Type Tester is specially designed for silicon sorting,it can quickly test the silicon type, heavy-doped, resistivity and current, and can be widely used in all kinds of silicon sorting, like granular polysilicon material, break semiconduct silicon wafer, chunk material, top and tail material and so on. Furthermore, it integrates two probes, three probes and four probes. With the three probes, it could show type and heavy type simultaneously, strongly improved the sorting efficiency.
-
Product
Partial Discharge Pulse Calibrator
TPK
-
Partial discharge puls calibrator TPK is a battery-powered handheld device for determining the correction factor in a Partial Discharge test circuit and to verify the Partial Discharge measurement.
-
Product
Portable Multifunction Calibrator
M143
-
Clarke-Hess Communications Research
The M143 Multifunction calibrator is a cost saving solution for calibration of electric meters with up to 1000 V and 20 A. It offersa basic accuracy of 0.01% in DC voltage for calibration of 3 and 4 digit multimeters. The resistance function is covered byeight fix resistors in range from 10 to 100 M. The calibrator offers TC temperature sensor simulation. It can be deliveredoptionally as well with RTD temperature sensor simulator. Thanks to its small dimensions and low weight the unit can be usedeasily for field calibration work.
-
Product
Digital Surface Resistance Test Kit
PAS-853BRM
-
- Surface Resistance Kit from 0.01 ohm to 9.99x1012 ohms- Nominal Full Range Tolerance Averages <±5%- Fully Automatic Resistance Range, Test Voltage and Electrification Period control- Determines if a surface is Dissipative, Conductive, or Insulative- Measures resistance point-to-point(Rtt) and point-to-ground (Rtg)- Measures resistance of Static Control Floors, ESD Work Surfaces and Packaging Material- Conforms to all ESD Association Standards for Resistive Characterization- Includes 2 each Conductive Rubber Electrodes- Packaged in a hard shell Carrying Case- Certificate of Calibration Traceable to NIST included
-
Product
Electronic Store Of Resistances
PS8
-
The module is intended for use as part of information measuring systems based on the VXI bus for software setting of resistance values with a given step along three independent channels.
-
Product
Accessories for Earth Resistivity (VES)
Electrodes
-
Earth resistivity / Accessories for earth resistivity (VES)
-
Product
Calibration Hangers And Weights
-
Calibrated Dead Weight are the official means by which torque analyzers and torque sensors are calibrated and are traced to National or International Standards, such as N.I.S.T, ISO and others. Many industries like as medical, aerospace, nuclear and others continuously calibrate their measuring equipment to comply with government regulations. For companies that prefer to have calibration capabilities in-house when their calibration requirements become extensive, they need calibration equipment.
-
Product
Thermocouple Calibrator
CA10
-
Dual function CA10 Thermocouple Calibrator can be used to source Type K thermocouple output values or measure Type K thermocouples. Quickly select output value using the rotary switch with coarse and fine adjustments.
-
Product
Medical Grounding Resistance Tester
2678YM
-
Shenzhen Chuangxin Instruments Co., Ltd.
Medical Grounding Resistance Tester,Product Introduction2678YM Medical Grounding Resistance Tester Is Used To Measure The Internal Electrical Equipment Of Grounding Resistance,Which Reflects The (Contact) Resistance Of Total Grounding Terminal Of Electrical Equipment.It Suitable For Measuring All Kinds Of Motors,Electrical Appliances,Instruments,Household Appliances And Other Equipment Resistan
-
Product
Wet-Well Calibrators
-
Electronic Development Labs, Inc.
A device used for high-accuracy temperature calibration of various sensors.
-
Product
Calibration Measurement
-
The process of comparing a measuring instrument's readings to a known, more accurate standard to detect and correct errors.
-
Product
Hart Multifunction Calibrator
Model 26 / 26 H
-
Kusam Electrical Industries Limited
The multi-functional field process calibrator with high accuracy and stability, which can provide powerful measurement or output functions & other special functions to meet all the calibration work for field process control.
-
Product
Resistance Meters
-
ACL provides surface resistance/resistivity meters and digital megohmmeters to quickly and accurately measure resistivity.
-
Product
Industrial Pressure Calibrator
2271A
-
The Fluke Calibration 2271A Industrial Pressure Calibrator provides a complete, automated solution for calibrating a wide variety of pressure gauges and sensors. Thanks to its modular design, it can be configured to meet different needs and budgets, and expanded to cover a broad workload. The 2271A is ideal for calibration laboratories starting out in pressure calibration because it offers wide pressure measurement capabilities in a single instrument. Everything you need for calibrating pressure is included; just connect supply pressure. And your investment will stand the test of time: as your workload grows and changes, the 2271A can grow and change too. Just add measurement modules.