Contamination
-
Product
Universal Differential pH Water Quality Sensors
SD7500CD
-
Continuous online pH monitoring in wastewater and coating industrial applications leads to contamination and eventually requires sensors to be replaced. A differential pH sensor utilizes a measurement technique designed to extend the working lifetime of sensors in challenging applications. Replacing the sensor reference (salt bridge) and buffered electrolyte solution can prevent sensor replacements, saving time and money. Our SD7500 Series features a combination sensor output; these differential pH sensors can be used with any conventional pH/ORP transmitter.
-
Product
High Performance Liquid Chromatograph Triple Quadrupole Mass Spectrometer
LCMS-8045
-
Equipped with a heated ESI probe, the LCMS-8045 has the highest sensitivity in its class. The heated ESI probe, high-temperature heating block, desolvation line (DL) and drying gas, all act to promote desolvation and prevent contamination due to the penetration of liquid droplets into the MS unit. This improves the robustness, so reliable and high-accuracy data can be obtained over the long term. The LCMS-8045 also achieves the world's fastest scan speed (30,000 u/sec) and polarity switching speed (5 msec). These enable ultra-high-speed, high-sensitivity analysis. The excellent cost performance of this system is demonstrated in food safety, environmental analysis, and other quantitative analyses, it can be upgraded to the LCMS-8060.
-
Product
Systems for Oil Quality Monitoring
-
*Reliable monitoring of oil contamination*Reliable machine and plant protection by permanent oil moisture monitoring
-
Product
Flexible Separators
-
The Parker flexible separators are a cost effective solution for the prevention of contamination into a hydraulic system
-
Product
Cleanroom Testing
-
MicroStat Laboratories -R.E.T.S.
We utilize the relevant test methods and standards set forth by the ESD Association, ANSI, ASTM, NFPA, IEST, IEC, ISO, or our clients’ in-house specifications. ESD testing is performed in-house; other testing can be arranged through sub-contractors with interpretation of results performed by experienced contamination control experts..
-
Product
Surface Contamination Monitors
-
Small-sized devices for measuring the ambient dose equivalent rate and the ambient dose equivalent of X-ray and gamma radiation, as well as measuring the flux density of beta particles (AT6130).
-
Product
Cleaning
Air Knives
-
Fraser Anti-Static Techniques Ltd
Produce fast-moving ionised air which can neutralise static electricity and remove contaminants.
-
Product
Permeability Cells
Flexible Wall Permeameter
-
The Permeability Cells - Flexible Wall Permeameter for Soil Samples performs permeability tests on normal and contaminated soil samples. The permeability cells are available either in brass for normal use or in stainless steel for contaminated materials. Top caps and pedestals are available for normal or contaminated materials.
-
Product
Ozone Gas Delivery Systems
-
MKS ozone gas delivery systems provide field-proven, high concentration, ultra-clean ozone generation for advanced thin film applications such as Atomic Layer Deposition (ALD), Chemical Vapor Deposition (CVD), Tetraethyl Orthosilicate (TEOS)/Ozone CVD (HDSACVD), contaminant removal and oxide growth. Gas delivery models have integrated ozone concentration monitoring, flow control, and power distribution. Additional system options include safety monitoring, status indicators and ozone destruction capability.
-
Product
Surface Contamination Kit
138/2
-
The Elcometer 138/2 Surface Contamination Kit provides the user with a means for testing invisible surface contaminants including:pHchloride ionsironsalts
-
Product
Flow Switches
-
Not susceptible to contamination and can be oriented in any pipe configuration make these flow switches for liquid or air maintenance free and reliable. Mechanical and electronic designs available
-
Product
4-Wire Resistance Measurement | Continuity & HiPot Cable & Wire Harness Testers
-
An add-on option for the CableEye HVX high voltage cable tester series that permits expanded testing for contact and wire resistance as low as 1 mΩ. After checking for opens, shorts, miswires, and resistance limits, the 4-wire Kelvin measurement applies a user-selectable test current from 10 mA to 1 A to determine connection resistance within 1 mΩ. The resistance profile of a model cable may be stored and used as a basis of comparison during later testing to reveal cold solder joints, faulty crimps, recessed pins, pin contact contamination, improper wire gauge, and stress-extruded wire.This option may be purchased with any new HVX tester, or added as an upgrade to any of your existing HVX testers.
-
Product
Electromagnetic Conductivity Meter
CMD-DUO
-
CMD-DUO electromagnetic conductivity meter completes our family of advanced digital conductivity meters with the instrument for deep surveys. Easy operated set with variable dipole distance allows multidepth field survey with results suitable both for apparent conductivity and model sections (inversion by IX1D). geological survey, water management (searching for potable water sources, groundwater protection, ground contamination monitoring), raw material prospecting, investigation of underground objects.
-
Product
Fourier Transform Infrared Spectrophotometer
IRTracer-100
-
This system achieves excellent sensitivity with an SN ratio of 60,000:1, high resolution at 0.25 cm-1, and high-speed scanning capable of 20 spectra/second. The performance of medium and higher end models is supported by high reliability including advanced dynamic alignment and an interferometer with a dehumidifier. This is compatible with applications active in a variety of circumstances, with a library of approximately 12,000 spectra and data analysis programs for contaminant analysis, and time course and rapid scan programs for reaction tracking.
-
Product
Spectrometers
-
Search and detection of gamma radiation sources with automatic identification of the radionuclide composition; Measurement of the dose rate of gamma radiation; Detection of neutron radiation and measurement of the neutron count rate (AT6102); Measurement of the dose rate of neutron radiation (external detection unit BDKN-03); Measurement of the flux density of alpha and beta particles from contaminated surfaces (external detection units BDPA-01 / BDPB-01)
-
Product
Dial Indicators
-
1. Always select the dial test indicator that best fits the application.2. Care should be taken while using a dial test indicator, try not to jolt the indicator, should you be unfortunate and drop a dial test indicator, get it re-calibrated/repaired before reusing it.3. Replace worn contact points only with those of a similar length from the centre of the ball stylus to the abutment shoulder.4. Always clean dial test indicators after use with a lint free paper or cloth and store the indicator in its box or in a dust free area.5. When using a dial test indicator, always position the dial test indicator in a horizontal plane to the surface media.6. Always use a rigid stand for mounting the dial test indicator.7. When measuring a rotating object, either between centres or in a vee block, ensure that the object is rotating in the correct direction. Never rotate the workpiece towards the contact point.8. When measuring a sliding object, only take readings when the object is moving directly towards the contact point, never away from the contact point or in a sideways manner.9. Avoid parallax errors by reading the dial directly from the front and square on to the dial.10. Never oil a dial test indicator as this attracts contamination, should the movement become erratic then the dial test indicator should be submitted to a reputable repair agent.11. Try not to expose dial test indicators to direct sunlight or in a high humidity environment.12. Never use a dial test indicator that has not been calibrated, if in doubt consult an appropriate authority.
-
Product
Ionizers
-
Panasonic Automotive & Industrial Systems Europe GmbH
There are many production processes where electrostatic charges disturb smooth operation. To eliminate static, ionizers are used. One typical field of application is the semiconductor industry where the components are extremely sensitive and can even be damaged by high electric static charges. Another example is the printing industry: Here friction between the rollers and the paper generates static. The static makes the paper cling and not move correctly through the printing machine. Especially when printing on vinyl or plastics, electrostatic charges need to be removed. In the packaging industry, plastic sleeves or foils tend to stick to each other, which can be prevented with an ionizer eliminate static. A general problem in assembling processes is the adhesion of dust and dirt particles. Contamination of workpieces can be prevented by having static eliminators neutralize and blow away undesired particles.
-
Product
Silver Ball Matrix Sockets
-
SM Contact is a unique contact that has precise silver balls held together by a proprietary conductive formulation. These conductive columns (diameter optimized for 50 ohm impedance) are suspended in a non-conductive flexible elastomer substrate with a patented solid core for enhanced durability and reliable performance over time, temperature and cycles. This flexible substrate is very compliant and resilient and enables the conductive columns to revert back to original shape when the force is removed. Solutions are available for 0.25mm to 1.27mm LGA, BGA, QFN, CSP, POP, WLP and other packages. The silver ball matrix contact technology is also available with a protective plunger matrix (a gold plated copper cylinder) that sits on top of the conductive columns. This plunger matrix protects the conductive column from contamination from various solder ball interfaces. A quickly replaceable plunger matrix enables minimal downtime during final production test. The product family code for this line of sockets is SMP.
-
Product
Biosafety Testing
-
Biological products derived from mammalian cell lines pose an inherent risk for the introduction of microbial or viral contaminants. In addition, the manufacturing process or product itself may introduce impurities that must be characterized.
-
Product
Laser Process Analyzers
LGR-ICOS Series
-
LGR-ICOS laser process analyzers accurately measure gas concentrations with extraordinarily high sensitivity, fast response and over a wide dynamic range in both simple and complex mixtures. They are ideal for contaminant monitoring in HyCO (syngas), fuel gas, petrochemicals, and semiconductor fabrication facilities.
-
Product
Thermal Desorption
-
Scientific Instrument Services, Inc.
The SIS Short Path Thermal Desorption units sit directly on top of a GC injection port to provide for the direct desorption of both volatile and semi-volatile samples into the GC injection port and column. Due to the "short path" of sample flow, these new systems overcome the shortcomings of previous desorption systems by eliminating transfer lines, which are easily contaminated by samples, and by providing for the optimum delivery of samples to the GC injector via the shortest path possible--the direct, syringe-like injection into the GC.
-
Product
Cleaning
Air Guns
-
Fraser Anti-Static Techniques Ltd
For neutralising static electricity and removing dust and other contaminants.
-
Product
Pulse AC Method Area Ionizers
ER-X Series
-
Panasonic Industrial Devices Sales Company of America
The ER-X Series Area Ionizers utilize the pulse AC ionization design to achieve high-speed charge removal of wide surface areas for high-volume production lines. In addition to supporting compressed air ionization, the ER-X also features both airless and low-pressure ionization modes for applications where tiny workpieces can be easily blown away. Additional features include automatic ion balance and discharge frequency control (manual control is also possible), flat discharge surface for easy cleaning, discharge needle air barrier design to reduce contamination of the needles, replaceable discharge needle unit for easy maintenance, and a dual head configuration for enhanced charge area and layout (2 different ionizer heads can be connected to a single controller).
-
Product
Gross Alpha/Beta Measurement Systems
-
Gross alpha/beta measurement is one of the simplest radioanalytical procedures which are applied widely as a screening technique in the field of radioecology, environmental monitoring and industrial applications. This procedure has been developed to determine whether radionuclide specific analysis is required to further characterize the water. Regular measurements of gross alpha and gross beta activity in water may be invaluable for early detection of radioactive contamination and indicate the need for supplemental data on concentrations of more hazardous radionuclides.
-
Product
Contaminometer
Conttest
-
Microtronic Microelectronic Vertriebs GmbH
Ionic contaminants can have a major negative impact on the reliability of assemblies. It therefore makes sense to check the assemblies for ionic contamination in the development stage and in the manufacturing process.The devices of the ConTTest series measure ionic pollution in accordance with international standards. The high-precision measuring system was designed to serve as a process control in production and to be used as a laboratory instrument in development and research.
-
Product
Stealth In-Foil Metal Detector
-
Stealth In-Foil metal detectors are custom manufactured to suit any foil packaging application or aluminum casting inspection. The Stealth uses digital signal processing technology and has high sensitivity levels to ensure the detection of the smallest ferrous contaminants, despite the presence of foil packaging. The built-in data collection software with USB data transfer establishes the Stealth as an effective critical control point complying with stringent HACCP regulations.
-
Product
Airborne Particle Counters
-
Complete contamination control solution including cleanroom certification and clean area monitoring, while meeting global requirements for data integrity.
-
Product
Inline Particle Monitor
iCountPD
-
The Parker iCountPD is a highly compact, permanently mounted laser detection particle size monitor that enables continuous monitoring of contamination levels in hydraulic and fluid circuits.Capable of communicating results in ISO4406 / AS4059 or NAS1638
-
Product
Chromatography Columns - Alumina
RediSep Alumina
-
Single use alumina columns run under normal phase conditions and offer different selectivity to silica. Neutral alumina columns are useful when samples are acid sensitive and prone to degradation on normal phase silica gel.Choose basic alumina to purify basic compounds without basic modifiers such as TEA or ammonium hydroxide. This avoids solvent swapping, washing the chromatography system, or contaminating subsequent runs.
-
Product
Oil Tan Delta Test Set
-
The Oil Tan Delta (OTD) is a laboratory instrument, which measures the Tan Delta, Resistivity and Relative Permittivity of insulating liquids. These tests give a wider picture of the overall quality of the insulating oil, and will indicate if there is any contamination. Megger has developed features of the OTD to ensure that productivity levels within laboratories are maximised. OTD test sets are supplied with sixteen standard test sequences pre-installed, to support a set of international standards.