product
Rack Mounted SolsTiS System for Cold Atom Experiments
SolsTiS-Rack Mounted
The rack mounted SolsTiS system is designed for the operation of portable cold atom experiments, although it is equally at home in a laboratory where space is limited. The pre-mounted system enables rapid set-up of desired experiments and investigations, minimising downtime due to laser assembly and integration. The system can be customised to your requirements with additional optics packages.
-
product
Milliampere-Level Test System
Shenzhen Sinexcel RE Equipment CO., Ltd
mA class battery test system, mainly used for battery material research, high-precision test, pulse charge and discharge test, DCIR test, cycle Life test. It provides powerful testing equipment for research institutions, universities and experimental centers of battery production enterprises
-
product
Very High Frequencies Analyzer
VHF104
VHF104 is an innovative Dynamic Mechanical Analyzer that applies a direct experimental method to measure the material viscoelastic properties over a very high frequency range from 100Hz up to 10kHz.
-
product
Dytronic Primary Transfer Ultra Stable Standard
RD-22 Ultra
The RD-22 Dytronic Primary Transfer Ultra Stable Standard represents the state-of-the-art technology in a commercially available AC transfer reference. The Ultra Stable RD-22 is a variant of the RD-22 Primary Transfer Standard that has been optimized for 120/240 V @ 5A operation to provide optimum stability. In a stable test environment, repeatability for a 10-second test of ±0.6 µWh/VAh is attained at 120 V and 240 V at 5A inputs with a 95% confidence interval. A typical experimental 2 repeatability of less than ±0.25 µWh/VAh is achieved. In a stable test environment, a reproducibility of ±2 µWh/VAh over a five-day interval is attained at 120 V and 240 V at 5A inputs with 95% confidence interval.
-
product
System for UHV Temperature Programmed Desorption (TPD) Studies
TPD Workstation
The Hiden TPD Workstation is a complete experimental system for UHV temperature programmed desorption (TPD) studies. The triple filter mass analyser is configured with a cooled shroud giving the analyser optimum sensitivity with minimum background contributions to desorption products from the sample. A fast sample load lock with sample transfer mechanism is included to provide for rapid sample change. The TPD Workstation features a multiport UHV chamber with heated sample stage coupled to a high precision triple filter analyser with digital pulse ion counting detector for ultimate sensitivity and time resolution.
-
product
Modal Shakers
The Modal Shop’s modal shakers are a proven solution in test laboratories around the world. With force ratings from 4.5 to 100 lbf (20 to 440 N), these shakers are suitable for a wide range of modal analysis applications. When performing experimental modal analysis and structural testing, the choice of excitation function and system will make the difference between a good measurement and a poor one. For many applications, an electrodynamic shaker system is the ideal choice. The Modal Shop’s line of modal shakers is designed to be highly portable, rugged and easy to set up in order to facilitate the best testing results. The exciter size allows a diversity of placement locations relative to the test structure, while minimizing any unwanted interaction between the exciter and test structure.
-
product
Software
SpecsLab Prodigy
SPECS Surface Nano Analysis GmbH
Ease of OperationMultidimensional Data AnalysisUser Authorization and SettingsModular Software ConceptOptional Automation ModulesSpecsLab Prodigy sets a new standard in electron spectroscopy. The modular software concept allows 1-, 2- and 3-dimensional data handling, fully integrated with optional Remote Device Control and Experiment Automation.
-
product
Finite Element Analysis
Response Dynamics Vibration Engineering, Inc.
An understanding of structural dynamics is very important to sound Finite Element Analysis (FEA). We have been performing FEA analysis for over 30 years and in most cases we have used experimental data to guide our modeling. While our engineers have had undergraduate and graduate courses in FEA, it is the years of modeling and analysis of existing structures that has taught us the most by forcing a thoughtful analysis of the key structural dynamics and then going though the process of making adjustments to boundary conditions, expanding the dynamics of the model in places, and making simplifications and approximations where possible.
-
product
TAM Assistant Software
TA Instruments’ robust application for instrument control, data acquisition, data analysis, and reporting for the Microcalorimetry TAM suite of instruments. The single, intuitive user interface combines real-time instrument monitoring, experimental design wizards, and application specific analysis capabilities, providing the user a comprehensive yet simple workflow solution.
-
product
Advanced Digital Lab Trainer
Designed to do experimentation with Digital & Analog circuits in the laboratory. It is a self contained trainer including Fixed & Variable DC Power Supplies, Pulse Generator with TTL/CMOS, Pulsar switches, etc In a single unit. It is very useful in project work and testing. A number of ready to use experiment circuits boards are available(Optional).
-
product
Electrostatic Discharge Generator
SKS-0230I
Shanghai Sanki Electronic Industries Co., Ltd.
The electrostatic discharge generator SKS-0230I has high reliability, the host itself can withstand 30kV electrostatic discharge test; 7-inch touch LCD screen, simple interface, convenient operation; unique combination test mechanism, multiple modes, arbitrary combinations of parameters, continuous testing; Equipped with a file management system, which can save commonly used test parameters, and can also import and export test parameters through U disk; has temperature and humidity monitoring function, real-time display of temperature and humidity indicators of the experimental environment; high- pressure precision resistance and capacitance combination, long service life, and Easy to replace to meet different experimental requirements (150pF, 330pF, 330Ω, 2000Ω);
-
product
Software
Simply GCxGC™
Simply GCxGC from LECO is a free tool designed to walk you through the steps of creating an optimized GCxGC method for your complex samples. Create a GCxGC method from scratch, or convert an existing 1D method to GCxGC. The tool will provide logical, step-by-step instructions to determine the secondary oven offset, second dimension column length, and experimentally evaluate stationary phases and peak capacity. Simply GCxGC takes a simple approach to GCxGC, helping you avoid unnecessary testing and streamline your method development cycle.
-
product
Cryogenic Temperature Sensors
Cernox®
Cernox® thin film resistance cryogenic temperature sensors offer significant advantages over comparable bulk or thick film resistance sensors. The smaller package size of these thin film sensors makes them useful in a broader range of experimental mounting schemes, and they are also available in chip form. They are easily mounted in packages designed for excellent heat transfer, yielding a characteristic thermal response time much faster than possible, with bulk devices requiring strain-free mounting. Additionally, Cernox sensors have been proven very stable over repeated thermal cycling and under extended exposure to ionizing radiation.
-
product
Ultra High Performance 3D CT System
UltraTom
3D micro-tomography (CT Scan) and nano-tomography. Modular system with multiple imagers and x-ray generators. Experimentations possible in-situ. Large volume Inspection and manipulation volume.
-
product
Experiment Maker
Experiment Maker turns SIGNAL into a programmable, automated, real-time experiment control system by adding capabilities for simultaneous acquisition and playback, microsecond timing and triggering, digital I/O and keyboard control. With SIGNAL and Experiment Maker, the researcher can construct presentation, measurement and control systems that would otherwise require months of programming.
-
product
Phase Detector Modulevalon
4002
sThe Valon 4002 Phase Detector module Independently measures both Gain/Loss and Phase between two signals. It is a perfect complement to all our Frequency Synthesizer modules and ideal for many experimental RF applications. The 4002 enhances the performance of the AD8302 base core.
-
product
Intelligent Laser Systems
ILS Laser Series
These laser systems offer fast tunability and accurate control of the absolute laser frequency. Tailored solutions with several fiber outputs can be proposed to develop a design adapted to any experimental setup. Such laser systems constitute a turnkey, reliable, and easy to use solution to implement immediate and ultra-stable atom cooling, atom interferometry, or Bose-Einstein Condensation.
-
product
Decade Box, Calibrated, Capacitance, 5, 100pF to 11111µF, 5 %
72-7265 CAL
The 72-7265 CAL from Tenma is a capacitance decade box. It is ideal for service, prototype and experimental use. This useful tool may be set at any non polarized capacitor value from 100pF to 11,111µF in 100pF increments. The decade accuracy is ±5% capacitors used throughout at <1μF, 1KHz test frequency, ≥1μF, 100Hz test frequency. It has weight of 304g/0.69lb and dimension is 14.7cm × 11.7cm × 5.5cm (5.79" × 4.61" × 2.16"). It is typically used in general applications, troubleshooting, maintenance, education and vocational training, production line testing, radio and TV services, working standards, research design & develop, physics laboratory work.
-
product
Digital Timing and Waveform Controller
Ice Bloc DCS
Ice Bloc DCS is a highly versatile sequencing system with multiple high-speed digital I/O, analogue outputs and a four-channel digital synthesiser. The DCS sports both single-shot, burst and infinite loop sequence capability. Designed to handle the demands of experimental control required for cold atom experiments, its compact form factor with customisable software interface allows easy integration with your experiments .
-
product
Correlation Analysis
EDM Modal Correlation Analysis allows the user to correlate two modal models; EMA and/or FEA models. Comparing the experimental data with that acquired through finite element analysis helps in validating the test results. Users can import the geometry model and mode shape data from FEA or EMA software.
-
product
Decade Box, Calibrated, Resistance, 7, 1ohm to 11.11111Mohm, 1 %
72-7270 CAL
The 72-7270 CAL from Tenma is a resistance decade box. It is ideal for service, prototype and experimental use. This useful tool may be set resistance value from 1 to 11,111,110 ohm in one ohm increments. The decade accuracy is ±1% resistors used throughout. It has weight of 320g/0.70lb and dimension 14.7cm × 11.7cm × 5.5cm (5.79" × 4.61" × 2.16"). It is typically used in general applications, troubleshooting, maintenance, education and vocational training, production line testing, radio and TV services, working standards, research design & develop, physics laboratory work.
-
product
Quizix Precision Pumps
The variety of models within the Quizix line offers several key advantages. The wide range of flow rates, pressure configurations and available options allow Quizix pumps to meet virtually any experimental requirement from bench top to pilot scale.
-
product
Hammer Impact Testing
EDM Modal Hammer Impact Testing provides the necessary features for a single-operator experimental modal test. The Hammer Impact GUI features an intuitive step-by-step process, allowing a user to easily go through the setup and then the testing.
-
product
Decade Box, Capacitance, 5, 100pF to 11.111µF, 5 %
72-7265
Ideal for service, prototype and experimental use, this useful tool may be set at any non-polarized capacitor value from 100pF~11,111F, in 100pF increments.
-
product
Switchgear & Universal Relay Test Set
Kvtester Electronics Technology Co.,Ltd
This device is very suitable for the power supply department for MP30 High-precision SF6 Gas Leak Detector, the installation and testing division and experimental institute of power supply. It can also serve as a supporting device for SF6 electrical devices and export products by SF6 high pressure switch manufacturers while improve the whole level
-
product
Strain Measurement Data Acquisition Modules
Automated strain measurement systems allow you to test measuring and experimental equipment as well as to combine data for the purpose of engines tests, tests of various components, manufacturing technological processes control and many other industrial applications.
-
product
Decade Box, Calibrated W/D & U, Resistance, 7, 1ohm to 11.11111Mohm, 1 %
72-7270 CAL DU
The 72-7270 CAL DU from Tenma is a resistance decade box. It is ideal for service, prototype and experimental use. This useful tool may be set resistance value from 1 to 11,111,110 ohm in one ohm increments. The decade accuracy is ±1% resistors used throughout. It has weight of 320g/0.70lb and dimension 14.7cm × 11.7cm × 5.5cm (5.79" × 4.61" × 2.16"). It is typically used in general applications, troubleshooting, maintenance, education and vocational training, production line testing, radio and TV services, working standards, research design & develop, physics laboratory work.
-
product
Climatic Chamber
Wewon Environmental Chambers Co, Ltd.
Climatic chamber is designed to do high temperature & high humidity, high and low temperature, or temperature cycling test, Climatic chamber mainly used for quality checking and assessing their quality reliability and life test. ● The climatic chamber simulate a full range of temperature testing and humidity testing conditions.These chambers are designed for ease-of-use, reliability and performance and include many user-friendly features standard with your purchase for the best value in the industry. ● Climatic test chambers are able to provide rapid product temperature change rates and use varying levels of relative humidity to locate design problems prior to shipping your products, improving product quality and reliability. climatic chamber For conditioning of samples prior to testing. Climatic chamber also can be used for a variety of materials of high – low temperature alternating test. The test temperature, humidity, time can be programmed. Provides conditions of temperature form -70 degree to +150 degree and of humidity from 20% to 98%. ● This type climatic chamber use 16bit Industry-grade PLC, programmable controller to control the test temperature test, and recycle time, more excellent anti jamming, high reliability of the data. ● TEMI880 large color LCD touched screen temperature & humidity controller. Real-time display program running time, the number of segment, the remaining time, repeat frequency,can display experimental data, including the pre-set segment time, heating status, calendar time, etc; climatic chamber directly digital display. ● Climatic chambers apply controllable silicon step-less adjusting technology to adjust temperature and humidity test continuously and precisely, and without over heated as the PID adjusting function. ● The thermal insulation material between outside and inside for climatic chamber is high-quality ultra-fine glass fiber insulation cotton, good thermal insulation effectivity. Thermal insulation layer composed of flame fire PU + glass wool insulation (insulation thickness 10.0 cm)
-
product
Components for System Integration
Bh offers a wide range of accessories to improve your photon counting experiment such as experimental control modules, optomechanics or implantable fiber probes for in-vivo applications. For PMTs and MCPs we offer different preamplifiers and a variety of routing devices for multi-detector operation. For a perfect SYNC signal, trigger modules and a SYG are available.
-
product
RF Milliwatt Meters
Type NDB-2 and NDB-3
National RF’s Type NDB-2 and NDB-3 RF Milliwatt Meters are affordable pieces of test equipment for both the RF laboratory and the home experimenter. Both provide a digital reading of RF power in dB reference 1 milliwatt of power into a 50 ohm load (i.e. 0 dBm). The circuitry consists of a low noise logarithmic amplifier that drives a digital A/D converting meter circuit. The lowest power levels that can be read are about –73 dBm (approximately 40 microvolts or .00000003 milliwatts). The maximum power input should not exceed 10 milliwatts (+10 dBm or .010 watts) when inputed without attenuation. An internal attenuator is provided and described in the next section.