ATE
ATE systems are used to test semiconductor devices, printed circuit boards, and electronic systems during manufacturing. AI prompted RL created', prevails upon the UUT to demonstrate It's fulfillment of test requirements.
See Also: Automatic Test Equipment, ATS, Functional ATE, Combinational ATE, Semiconductor Test, PXI Switching, PXI Chassis, PXI Matrix, Automated Test Equipment, Automated Test Systems
-
Product
Redundant Strap down INS ATE Test Station
-
Redundant Strap down Inertial Navigation System (RESINS) checkout test station comprises of cPCI chassis with various functional I/O modules like ADC, DAC, DIO, VFC, Relay matrix, MIL 1553, GPIB, Serial communication interfaces and Custom Built System interface adaptor.
-
Product
Imperial Test Executive
ITE
test
The Imperial Test Executive (iTE) is a UI shell that sits on top of National Instruments TestStand. It provides a simple but elegant interface to execute your NI TestStand sequences. The iTE software was designed to allow general operators to execute ATE testing software without requiring any knowledge of NI TestStand. Training an operator to use this system typically takes less then 5-minutes.
-
Product
PCI Very High Density Multiplexer, 99-Channel, 2-Pole
50-670C-022-99/2
Multiplexer Module
The 50-670C-022-99/2 is a 99-channel, 2-pole MUX and is part of a series of very high density multiplexer cards feature a wide range of switching configurations. Typical applications include signal routing in ATE and data acquisition systems.
-
Product
PXI 8 Slot BRIC 322x8 1-Pole Dual Analog Bus (7 sub-cards)
40-560A-121-322X8-M
Matrix Switch Module
This version of our BRIC is part of a range of high-density PXI matrix modules. These modules are available in 2, 4 or 8 slot PXI sizes to suit all high-performance matrix requirements and are constructed using instrumentation quality reed relays. With this high level of switching density, these PXI matrix modules allow a complete Functional ATE system to be housed in a single 3U PXI chassis. These BRIC matrix modules allow the use of lower cost 8 or 14-slot PXI chassis.
-
Product
Pattern Conversion
Wave Wizard
-
Wave Wizard generates a test program according to device spec. It avoids the inherent problems that exist when trying to force an event-driven simulation into a constrained ATE test program, by considering device perspective.
-
Product
224 TTL Channels, Digital I/O With 4 Counters PXI Card
GX5732
Digital I/O
The GX5732 is a 6U PXI static digital I/O card with 224 TTL I/O channels. Designed for ATE, data acquisition, or process control systems where a large number of discrete I/O channels are required, the GX5732 offers the highest digital channel density in the industry for a single PXI plug-in board.
-
Product
PXI 4 Slot BRIC 25x32 1-Pole (5 sub-cards)
40-562A-021-25X32
Matrix Switch Module
This version of our BRIC is part of a range of high-density PXI matrix modules. These modules are available in 2, 4 or 8-slot PXI sizes to suit all high performance matrix requirements and are constructed using instrumentation quality reed relays. With this high level of switching density, these PXI matrix modules allow a complete Functional ATE system to be housed in a single 3U PXI chassis. These BRIC matrix modules allow the use of lower cost 8 or 14-slot PXI chassis.
-
Product
PXI 8 Slot BRIC 40x32 1-Pole (8 sub-cards)
40-562A-121-40X32
Matrix Switch Module
This version of our BRIC is part of a range of high-density PXI matrix modules. These modules are available in 2, 4 or 8-slot PXI sizes to suit all high performance matrix requirements and are constructed using instrumentation quality reed relays. With this high level of switching density, these PXI matrix modules allow a complete Functional ATE system to be housed in a single 3U PXI chassis. These BRIC matrix modules allow the use of lower cost 8 or 14-slot PXI chassis.
-
Product
PXI 2 Amp Multiplexer, Quad 16-Channel, 1-Pole
40-635A-008
Multiplexer Module
The 40-635A-008 is a quad 16-channel, 1-pole MUX and is part of a range of Multiplexer modules available in 9 standard density and 9 half density configurations, all using high quality electro-mechanical signal relays allowing each channel to switch current up to 2A and voltage up to 300VDC/250VAC. The module is suitable for signal routing in ATE and data acquisition systems. Connections are made via a front panel 78-way D-type connector.
-
Product
LXI High Density Dual 8x64 2A Matrix
60-552-008
Matrix Switch Module
A high-density single pole LXI matrix module capable of switching up to 300VDC/250VAC, 2A (60W max). The use of high-quality electro-mechanical relays offers high switching confidence for signal routing in large ATE systems.
-
Product
PXI 4 Banks of 40 Channel 1 Pole MUX
40-615-022-4/40/1
Multiplexer Module
High density multiplexer modules featuring a wide range of switching configurations, especially useful where a large number of small multiplexers are required. Typical applications include signal routing in ATE and data acquisition systems. Each module is factory configured into one of the configuration modes. Connections are made via a front panel 200-pin connector.
-
Product
PXI 2A Multiplexer, 2-Bank, 32-Channel 2-Pole
40-614-011
Multiplexer Module
The 40-614 High Density 2 Amp multiplexer module is available in 20 configurations. All configurations use high quality electro-mechanical signal relays allowing each channel to switch current up to 2A and voltage up to 200VDC/140VACThe module is suitable for signal routing in ATE and data acquisition systems. User connections are made via a front panel 160-pin DIN 41612 connector which is fully supported by our range of cabling and connector solutions.
-
Product
PXI 4 Banks of 20 Channel 1 Pole MUX
40-615-021-4/20/1
Multiplexer Module
High density multiplexer modules featuring a wide range of switching configurations, especially useful where a large number of small multiplexers are required. Typical applications include signal routing in ATE and data acquisition systems. Each module is factory configured into one of the configuration modes. Connections are made via a front panel 200-pin connector.
-
Product
Advanced Power System - DC Power Supply, 160 V, 12.5 A, 2000 W
N6977A
DC Power Supply
The N6978A is designed for automated test equipment (ATE) applications where high performance is critical.
-
Product
PXI 8 Slot BRIC 180x8 1-Pole (6 sub-cards)
40-561A-121-180X8
Matrix Switch Module
This version of our BRIC is part of a range of high-density PXI matrix modules. These modules are available in 2, 4 or 8 slot PXI sizes to suit all high performance matrix requirements and are constructed using instrumentation quality reed relays. With this high level of switching density, these PXI matrix modules allow a complete Functional ATE system to be housed in a single 3U PXI chassis. These BRIC matrix modules allow the use of lower cost 8 or 14-slot PXI chassis.
-
Product
PXI 8 Slot BRIC 90X16 1-Pole (6 sub-cards)
40-561A-121-90X16
Matrix Switch Module
This version of our BRIC is part of a range of high-density PXI matrix modules. These modules are available in 2, 4 or 8 slot PXI sizes to suit all high performance matrix requirements and are constructed using instrumentation quality reed relays. With this high level of switching density, these PXI matrix modules allow a complete Functional ATE system to be housed in a single 3U PXI chassis. These BRIC matrix modules allow the use of lower cost 8 or 14-slot PXI chassis.
-
Product
ATEÂ Socket
-
Design ATE socket according to customer's requirementsUse on auto-test eqiupments and handler.Pitch range from 0.30 to 1.0mm.Pin amount: 2 and above.Key material: Peek,Torlon.etcContact with top pogo pin
-
Product
PXI 8 Slot BRIC 440x4 1-Pole (10 sub-cards)
40-562A-121-440X4
Matrix Switch Module
This version of our BRIC is part of a range of high-density PXI matrix modules. These modules are available in 2, 4 or 8-slot PXI sizes to suit all high performance matrix requirements and are constructed using instrumentation quality reed relays. With this high level of switching density, these PXI matrix modules allow a complete Functional ATE system to be housed in a single 3U PXI chassis. These BRIC matrix modules allow the use of lower cost 8 or 14-slot PXI chassis.
-
Product
PXI High Density Mux 5 Channel 16 Pole
40-670A-021-5/16
Multiplexer Module
The 40-670A series of very high density multiplexer modules feature a wide range of switching configurations. Typical applications include signal routing in ATE and data acquisition systems. The 40-670 multiplexer may be operated as a conventional multiplexer with break-before-make action when a new channel is selected.In addition multiple channels may be simultaneously selected (not available in 1 pole mode).
-
Product
Programmable Digital Attenuator
LDA-602EH
-
The LDA-602EH has a large attenuation range of 120 dB with an exceptional 0.1 dB step size, allowing for both precision and accuracy during fading tests or device characterizations. This attenuator also features a fast 15 us switching speed, an operating temperature from -30oC to 50oC, a maximum RF input of +28 dBm, and is priced at $875. The LDA602-EH operates with a low insertion loss of 9 dB to 6 GHz, an input IP3 of +55 dBm and a typical VSWR of 1.3:1. Easily programmed for ATE applications, the LDA digital attenuators are a cost effective solution whether you are in engineering, the production test lab, or in the field. Units are ROHS compliant and can be used with any PC or laptop computer with USB 2.0 port (or powered USB hub) and Windows operating system. Lab Brick Signal Generators are provided with easy to use Lab Brick GUI software, 32 and 64 bit API DLL files, LabVIEW and Linux compatible drivers.
-
Product
PXI High Density Multiplexer, 8-Bank, 8-Channel, 2-Pole
40-610A-005
Multiplexer Module
The 40-610A-005 is a 8-bank, 8-channel, 2-pole MUX and is part of our range of PXI high density reed-relay based multiplexer modules. The range includes a wide choice of switching configurations which are especially useful where a large number of small multiplexers are required. Typical applications include signal routing in ATE and data acquisition systems.
-
Product
PXIe Microwave Signal Generator
LSX4091X
Microwave Signal Generator
The LSX4091X is a 40GHz Single Channel PXIe Microwave Signal Generator that offers industry leading performance, in a modern modular 2 slot PXIe format that can be used on the desk, embeded in a system or or easily scaled up to multiple channels ATE systems.
-
Product
Automated Aerospace and Defense Test
test
Obsolescence management, evolving RF requirements, and design for test (DFT) challenges every test organization in the aerospace and defense industry. Organizations are transitioning from rack-and-stack box instruments and closed-architecture automated test equipment (ATE) systems to smarter test systems built on a modular platform that scales to meet current and future needs.
-
Product
PXI High Density Mux 99 Channel 1 pole
40-670A-021-99/1
Multiplexer Module
The 40-670A series of very high density multiplexer modules feature a wide range of switching configurations. Typical applications include signal routing in ATE and data acquisition systems. The 40-670 multiplexer may be operated as a conventional multiplexer with break-before-make action when a new channel is selected. In addition multiple channels may be simultaneously selected (not available in 1 pole mode).
-
Product
PXI 2A Multiplexer, 1-Bank, 16-Channel 8-Pole
40-614-018
Multiplexer Module
The 40-614 High Density 2 Amp multiplexer module is available in 20 configurations. All configurations use high quality electro-mechanical signal relays allowing each channel to switch current up to 2A and voltage up to 200VDC/140VACThe module is suitable for signal routing in ATE and data acquisition systems. User connections are made via a front panel 160-pin DIN 41612 connector which is fully supported by our range of cabling and connector solutions.
-
Product
PXI MUX 4 Banks of 32 Channel 1 Pole
40-610-022-4/32/1
Multiplexer Module
This series of high density multiplexer modules feature a wide range of switching configurations, especially useful where a large number of small multiplexers are required. Typical applications include signal routing in ATE and data acquisition systems. Connections are made via a front panel 200-pin connector. Inter-bank linking relays allow multiplexer size to be increased in multiples of in multiples of three by joining the common terminals of adjacent banks. Closing one linking switch produces a 6-channel multiplexer, closing all linking switches produces an 54-channel multiplexer
-
Product
DC Power Module, 5V, 20A, 100W
N6741B
Power Module
The Keysight N6741B is a 100 W basic DC power module that provides programmable voltage and current, measurement and protection features at a very economical price, making these modules suitable to power the DUT or to provide power for ATE system resources such as fixture control.
-
Product
Combination Board Tester
ATE QT2256-640 PXI
-
Qmax Test Technologies Pvt. Ltd.
Most commercial ATEs does only functional test and do not carry out DC/AC parameter testing, which are very essential in increasing the fault coverage and for achieving near zero field returns. The testing challenges get worse when the boards are equipped with BS compatible components, DSP chips and CPUs or micro controller based boards. ATE QT2256-640 PXI system is designed as a combination board tester capable of testing highly complex and PCBs employing various techniques on a single platform. It can be easily upgraded to 640 digital channels and with programmable UUT power supplies, IEEE or PXI external instrumentation, Bus cycle signature system, ICE and integrated Boundary scan Test AC/DC parametric testing. The ATE is interfaced to an external host PC using a PCI express interface card allowing a maximum data transfer rate. Most commercial ATEs does only functional test and do not carry out DC/AC parameter testing, which are very essential in increasing the fault coverage and for achieving near zero field returns. The testing challenges get worse when the boards are equipped with BS compatible components, DSP chips and CPUs or microcontroller based boards.
-
Product
PXI Very High Density Multiplexer, 2A, 79-Channel, 2-Pole, Single Channel Mode
40-611B-002
Multiplexer Module
The 40-611B-002 (PXI) and 42-611B-002 (PXIe) modules are 79-Channel 2-Pole multiplexers. A 158-Channel 1-Pole configuration is also available. They use high quality electro-mechanical signal relays allowing switching up to 2 A and voltage up to 300 VDC/240 VAC.They are suitable for signal routing in high channel count ATE and data acquisition systems. Connections are made via a front panel 160-pin DIN 41612 connector.
-
Product
PXI High Density Multiplexer, 5-Bank, 16-Channel, 1-Pole
40-615A-015
Multiplexer Module
The 40-615A-015 is a 5-bank, 16-channel, 1-pole MUX and is part of our range of PXI high density reed-relay based multiplexer modules. These feature a wide range of switching configurations and are especially useful where a large number of small multiplexers are required. Typical applications include signal routing in ATE and data acquisition systems. Connections are made via a front panel 200-pin connector.