Thermocouple Loggers
Data Acquisition from thermocouples and data record of termperature events.
See Also: Temperature Loggers
-
Product
Gauge Type T Thermocouple Wire
W-TW-36P2
-
Most thermocouple wire used in the manufacture of sensors is "Special Limits" wire which, to meet NIST standards, must be accurate to 0.5°C in the range 0-50°C. This means that even with most sophisticated electronics, the best possible accuracy for the system is 0.5°C.
-
Product
Data Logger
MS6-Rack
-
The complete solution for monitoring of temperature, humidity and other values. For mounting to 19" rack - one rack unit 1U. Enables to build in the optional MP016 output relays module with 16 relays - see Optional accessories.
-
Product
Data Loggers
-
Data loggers are an essential component in data acquisition systems. They can scan a wide variety of measurement sensors, perform any programmed calculations, convert the data to other units of measurement, and store the data in memory. Data loggers can also transmit the data for analysis, sharing, and reporting, as well as control external devices.
-
Product
Panel Pilot Data Logger Displays & Boards
-
A range of 4.3" and 7" screen capacitive touch displays and add-on boards, designed for use with PanelPilotACE Design Studio, a free drag-and-drop style software package for rapid development of advanced user interfaces and panel meters.
-
Product
Data Loggers
-
An electronic device that records data over time or in relation to location either with a built in instrument or sensor or via external instruments.
-
Product
State Data Logger
State101A
-
The State101A is one of MadgeTech's newest data loggers. It is part of a new series of low cost, state-of-the-art data logging devices. MadgeTech has taken the lead in offering the most advanced, low cost, battery powered data loggers inthe world today.
-
Product
Wireless Data Logger MSR145WD
MSR145WD
-
Wireless monitoring of measurement data and rapid reading of measured values – this ease of use is offered by the new MSR145WD wireless data logger. The mini-logger is equipped with Bluetooth Low Energy, a bright OLED graphic display and the optional web-based service MSR SmartCloud for data monitoring from any location.
-
Product
7-Ch Thermocouple Input Module
ADAM-5018
-
Accuracy Bandwidth: ±0.1% or better, 13.1 Hz @ 50 Hz, 15.72 Hz @ 60 HzSampling Rate: 10 samples/sec. (total)High Common Mode: 2000 VDCIsolation Voltage: 3,000 VDCFault and Overvoltage Protection: Withstands over voltage up to ±35 VCMR @ 50/60 Hz: 92 dB minInput Impedance: 20 MΩ. (Build-in 120 Ω Register for Current Input)Built-in TVS/ESD ProtectionFilter function: Yes
-
Product
Thermocouple Alarm Setting Transmitter
Model TAT
-
Kusam Electrical Industries Limited
• 4 Digits Display For Input Signal:0 - 9999 • Output Signals Are Programmable. • Ultra-thin Dimension, 27mm width. • Non-Combustible PC Case .DIN Rail or Wall Mounting. • High Dielectric Strength ( AC 2KV / Min , Input / Output / Power )
-
Product
Charge Logger Sensor
NUL-246
-
This sensor measures electrostatic charges. It can be seen as a highly sensitive electroscope indicating whether a charge is positive or negative. Other uses are: to explore the nature of static charge, to measure both charge and voltage, to measure charge by induction, quantify the charge on a capacitor or discover the charge distribution on a conducting sphere.
-
Product
CL & DL Series Environmental Data Logger
-
Select from a wide range of motion and temperature sensors for motion detection, temperature, humidity, carbon dioxide (CO2) and carbon monoxide (CO). We carry passive infrared (PIR) sensors that detects human-body generated infrared waves to indoor motion detection. They can be configured to automatically switch on a light or trigger alarms if motion is detected. The DL-300 can also be used on mobile devices so it is easy for you to monitor your room temperature, humidity, carbon dioxide (CO2) and carbon monoxide (CO) level on your phone.
-
Product
Single Channel Data Logger
-
Our range of Single Channel Data Logger are impeccable designed and take only single type of input. The one is a factory set and there are many sensors required. This an really work on the data stream including Modbus or a dedicated protocol but do not work on the applications where there is no sensor input.
-
Product
Specialty Data Loggers
-
Includes dataloggers that measure pH, CO, Moisture, Light, Water level, Wind Speed, and others.
-
Product
Basic Quad J-Type Analog Thermocouple Amplifier
SEN-30103-J1
-
Analog thermocouple amplifier board based on the AD849x from Analog Devices (successor of the AD597). This quad-channel thermocouple board converts the very low voltage signal from a thermocouple to a highly-linear, 0.005V/C output with either 0V or 1.245V offset (both configurations stocked) while removing unwanted noise from the signal. Many supply and output configurations are available with this board, though the PCB was designed with Arduino in mind. Specifically, the output header will plug directly into a standard Arduino Uno or Mega, with a pin-for-pin match for power supply, ground and analog outputs. With a 5V Arduino, temperatures from 0C to 1,000C are possible with the 0V offset board and -249C to 750C with the 1.245V offset board. If using a 3.3V microcontroller (Due, etc), the board must be supplied with no more than 3.3V to avoid damaging the microcontroller. Temperature measurement range is dependent on the supply voltage. It is possible to supply the board with higher voltages to allow temperature measurement over the entire operating range of the K-Type and J-Type thermocouples, allowing use with more capable data acquisition equipment.
-
Product
Ammonium Logger Sensor
NUL-240
-
The NeuLog ammonium sensor can be used to measure the concentration of ammonium ions (NH4+) in aqueous samples. It can be used to evaluate the degree of contamination of water due to the use of fertilizers.Ammonium measurements can also be very relevant to study the nitrogen cycle in general and to relate this cycle to plants and algae.
-
Product
3D Acceleration Logger Sensor
NUL-227
-
This is a 3D (three dimensions) acceleration sensor which displays each dimension one at a time. It allows measuring the acceleration of moving bodies such as a body oscillating in a spring or in a moving vehicle.
-
Product
Cable Assembly, Receiver, Thermocouple, 20", TB-4353
540291010162
Cable Assembly
Cable Assembly, Receiver, Thermocouple, 20", TB-4353
-
Product
Thermocouple Contacts
-
Thermocouple contacts are manufactured from chromel or alumel alloys and are color-coded for easy identification. They are crimp terminated and easily inserted into connector modules and readily removed using a special removal tool.
-
Product
Wireless Moisture Monitors Data Loggers
-
Lignomat’s monitoring systems can measure:*wood moisture, bamboo, gypsum, sheetrock, solid materials*relative humidity and temperature, DPT, GPP, EMC*EMC*concrete moisture using in-situ RH probes ASTM F 2170*Surface and interior temperature https://www.lignomatusa.com/wp-content/uploads/2015/02/wireless-moisture-data-logger.jpg
-
Product
Thermocouple, Module, Receiver, 90 Series, 64 Position
510104133
Receiver Module
Primary mating module 510108124. (May mate with other ITA modules, as well.) *Please note: VPC receiver modules must be separated into two pieces in order to extract contacts. For detailed instructions please consult the user manual/procedure sheet for this module before extracting contacts.
-
Product
Programmable Data Logger
HD32MT.1
-
Programmable datalogger able to capture and store the values measured by a series of sensors connected to its inputs. 8 analoge input, 8 digitale input, 2 puls input, potential free contacts, alarming. Programmable through software. RS485, RS232.
-
Product
Wireless Compact Loggers
-
Temperature and Humidity Data Logger for Managing Production Plants and Agricultural Sites
-
Product
Data Logger
MS55D
-
The complete solution for monitoring of temperature, humidity and other values.
-
Product
Isolated Thermocouple Input Module
ADAM-3011
-
1000 VDC, fully isolatedConfigurable thermocouple typeFlexible DIN-rail mountingLinearized thermocouple measurementOperates from a single +24VDCTemperature range of 0 to 50°C
-
Product
Gauge Type T Thermocouple Wire
W-TW-40P
-
Most thermocouple wire used in the manufacture of sensors is "Special Limits" wire which, to meet NIST standards, must be accurate to 0.5°C in the range 0-50°C. This means that even with most sophisticated electronics, the best possible accuracy for the system is 0.5°C.
-
Product
Relative Humidity Logger Sensor
NUL-207
-
This sensor measures relative humidity. It can find use in recording variations with weather conditions and the relative humidity effect on organisms such as seedlings and insects. It is located in a plastic box with exposure of the sensor being through a hole in the side.
-
Product
Differential Pressure and Temperature Data Logger
PRTemp1000D
-
The PRTemp1000D is a rugged pressure and temperature data logger designed to accurately monitor and record pressure and temperature at user programmable reading intervals. The rugged stainless steel design allows for the device to be placed in harsh environments, which makes it well suited for use with air conditioning systems, chilled water, hot water, air, gas, oil and steam pressure systems.
-
Product
Basic Quad K-Type Analog Thermocouple Amplifier
SEN-30103-K0
-
Analog thermocouple amplifier board based on the AD849x from Analog Devices (successor of the AD597). This quad-channel thermocouple board converts the very low voltage signal from a thermocouple to a highly-linear, 0.005V/C output with either 0V or 1.245V offset (both configurations stocked) while removing unwanted noise from the signal. Many supply and output configurations are available with this board, though the PCB was designed with Arduino in mind. Specifically, the output header will plug directly into a standard Arduino Uno or Mega, with a pin-for-pin match for power supply, ground and analog outputs. With a 5V Arduino, temperatures from 0C to 1,000C are possible with the 0V offset board and -249C to 750C with the 1.245V offset board. If using a 3.3V microcontroller (Due, etc), the board must be supplied with no more than 3.3V to avoid damaging the microcontroller. Temperature measurement range is dependent on the supply voltage. It is possible to supply the board with higher voltages to allow temperature measurement over the entire operating range of the K-Type and J-Type thermocouples, allowing use with more capable data acquisition equipment.