EMI
unintentional signal interference originating within or outside the system or circuit. Also known as: Electromagnetic Interference
See Also: Interference, Interference Generators, EMI Receivers, RFI, EMC, LISN
-
product
RF Amplifiers up to 1000 MHz
Narrow and Broad band high power RF modules and rack mount amplifier systems using solid state devices including LDMOS and GaAs in Class A and Class A/B topologies for Pulse, AM, FM, continuous wave and digital modulation applications that include EW, Radar, Jamming, EMI and EMC radiated immunity, and wireless communications testing.
-
product
ITA, 9050, 50 Module, Double Tier, for EMI
410104577
ITA, 9050, 50 Module, Double Tier, for EMI
-
product
Magnetic Resonance Instruments
Integrated Dynamics Engineering
MRI systems represent a significant investment. As magnetic resonance images can be distorted by electromagnetic fields, frequently the location is isolated by passive shielding to somewhat insulate the detectors from image distorting EMI. But for a fraction of the cost of the machine an active EMI compensation can fully protect the image from damaging fields generated by other electrical equipment, passing traffic, elevators or other nearby equipment.
-
product
EMI/EMC Compliance Consulting
EMI Devices offers a broad range of consulting services in the field Electromagnetic Compatibility. Our extensive knowledge of consumer electronics and worldwide regulatory requirements allow us to design Electromagnetic Compatibility Regulatory Compliances from the start.
-
product
Microwave Delay Line
E501
The Eastern OptX Series E501 / Microwave Delay Line is a high performance turnkey solution for radar and communications market. The E501 allows for ultra wide bandwidth, low loss, high isolation and immunity from EMI and EMP with timedelays up to 250 usec at frequencies up to 18 GHz.
-
product
EMI Filters And Application-Specific Integrated Products (ASIP)
An electromagnetic interference (EMI) filter is used in electronic circuits to improve system immunity against unwanted external electromagnetic signals from neighboring circuits and to avoid emitting radiation (“noise”) that may disturb the same nearby circuits by canceling unwanted frequencies.
-
product
Talon 26 GHz Sentinel Intelligent Signal Scanning RTX Extreme Recorder
Talon RTX 2684
- Search and capture system using Pentek's Sentinel™ Intelligent Signal Scanner- Captures RF signals from 1 GHz to 26 GHz- Capture and scan bandwidths up to 500 MHz- Selectable threshold triggered or manual record modes- 12-bit A/Ds with 57.5 dB SNR & 72 dB SFDR- Built-in DDC with selectable decimations of 4, 8 and 16- Rugged 1/2 ATR MIL-spec chassis for harsh mechanical and thermal environments- Environmentally sealed- Internally conduction-cooled- Fully sealed for RF emissions with EMI power line filter- MIL-STD circular connectors- Compact and lightweight: about 23 lb (10.4 kg)- QuickPac® drive packs allow quick removal of all data storage up to 61 TB via the front panel- Ideal for UAVs, military vehicles, aircraft pods and outdoor environments- Sustained real-time record rates up to 4 GB/s- 12 to 28 VDC power supply- Optional GPS receiver for precise time and position stamping- SystemFlow® GUI, SystemFlow API, and Signal Viewer analysis tools- Optional telnet remote connection to recorder
-
product
Absorbing Clamp
AB-CLP
• EMI Receiver equipped with absorbing clamp can indirectly test radiated interference power of household electrical appliance, power tool and similar electrical appliance with frequency from 30~300MHz.
-
product
i2 MX
i2 MX, VPC’s handheld ITA offers a configurable connector in a slim 0.8" footprint and provides EMI protection features. With multiple I/O options to choose from, i2 MX allows you to engineer the ideal connector to meet your test application needs.
-
product
EMI Receiver
KH3931
Beijing KeHuan Century EMC Technology Co,.LTD
* Detection frequency range: 9KHz-30MHz * Frequency stability: 1X10-6 * Frequency resolution: (9kHz ~ 150kHz): 30Hz; (150kHz ~ 30MHz): 1kHz * Test error: ±2dB * Corresponding characteristics of pulse: in line with national standard GB/T6113.1-1995 * Detection time constant: in line with national standard GB/T6113.1-1995
-
product
Electromagnetic Interference Test
Electromagnetic interference (also known as radio frequency interference) tests are used to determine the electromagnetic characteristics of electrical, electronic, and electro-mechanical equipment. Electromagnetic interference, both radiated or conducted, can affect the performance of equipment. Electromagnetic interference tests are specified as follows: conducted emission, radiated emission, conducted susceptibility, and radiated susceptibility.
-
product
ITA, I2 MX, EMI, XL Backshell (XL Bend Radius and Cable Exit)
410130126
This model i2 MX includes the backshell only and does not include module inserts or front protective cover. The XL-size backshell allows for a greater cable bend radius and large cable exit. The max cable bundle eff diameter= 1.67".
-
product
Emissions Test System
PC-114
Perform Radiated & Conducted EMI pre-compliance testing at your facility up to 1 GHz. Com-Power PC-114 EMI emissions test system is a ideal solution performing pre-compliance EMC testing from 9 kHz - 1 GHz.. It has essential equipment needed for radiated and conducted EMI emissions measurements. The system includes a spectrum analyzer, antennas, near field probes, a preamplifier, LISN and a non conductive antenna tripod. Pre-compliance testing in EMC is a commonly used term not easy to define. In general, it implies testing done prior to formal testing for legal compliance. Formal legal compliance is performed at a facility designed and equipped with test instrumentation that is fully compliant with the applicable EMC standards. Such facility and instrumentation is capital intensive and can be expensive even to rent and not easily available. Compliance testing is performed per exacting requirements of the Standards and other reference documents adhering to the test methods and last detail. In addition, the test facility may require to be accredited by an accreditation body such as NVLAP, A2LA. Often it is desirable to know prior to compliance testing at such facility, whether a product is close to compliance and also how close. Pre-compliance testing is specially useful for specifications such as FCC, Part 15, EN 55022 or EN 55011 (CISPR 22 or CISPR11). Pre-compliance testing usually means using the full compliance methods but making a few educated compromises in use of site or equipment to reduce costs and testing time. Here are some benefits of pre-compliance testing.
-
product
EMI EMC test Solutions for Immunity
Scientific Mes-Technik Private Ltd
EMI EMC test Solutions for Immunity
-
product
EMI Receiver System
EMI-9KC/EMI-9KB
EMI-9KB is an automatic EMI receiver system. It is a main test system for EMI (Electro Magnetic Interference) testing. The EMI-9KB is produced by the full closure structure and strong electro-conductibility material, which has high shielding effect. Due to the new technology for the EMI Test System, it solved the instrument self-EMI problem. The test results are according to the international format test report. The EMI Test System EMI-9KB fully meets CISPRl6-1, GB17743, FCC, EN55015 and EN55022.
-
product
EMI Tester
The EMI tester automatically measures the noise distribution of the electric field and the magnetic field radiated from electronic equipment with high accuracy.・ Even if PCB and IC parts have complicated bumpy shape and surface. The movable assembly can automatically trace them.・ EMI noise distribution is expressed as a variety of maps, such as 4D/3D/2D graphics and cross section view.
-
product
Mounting Flange Kit, G40X, Receiver, Agilent M9019/Adlink PXES-2785
310113801
Mounting Flange Kit, G40X, Receiver, Agilent M9019/Adlink PXES-2785.Includes hardware required to mount flanges to the G40X EMI receiver, slide kit and Agilent M9019/Adlink PXES-2785.
-
product
Bench Power Supplies
Series ABC
Kepco¹s ABC bench power supply embodies the latest features: keyboard data entry, interactive digital display, integral GPIB support, software calibration, high frequency switch mode conversion, wide range input (85-264V a-c) and power factor correction. It meets the EN 61000-3-2 harmonic limits. A built-in EN 55022 Class B input EMI filter is provided. Integral External Trigger and RS 232 ports are now standard features.
-
product
Immunity Development System
Used for EMI suppression in printed circuit boards during the development phase. The developer can use the E1 set to quickly identify the causes of burst and ESD interference. This allows the developer to design suitable measures to solve the causes of the interference. It can also be used to test the effectiveness of the measures taken.
-
product
WiFiScope WS6+EMI: 1 GS/s 250MHz BW, 4 Channel, Digital Storage Oscilloscope, Spectrum Analyzer, Voltmeter, Transient Recorder
WS6-1000XME-W5
TiePie engineering has introduced the WiFiScope series oscilloscopes. The new range WiFi oscilloscopes can be used via an ethernet connection (LAN, WiFi or WAN) but also still with a USB 2.0 / 3.0 connection. The built-in battery gives the WiFiScope the possibility to perform fully wireless measurements. Measurements can then be performed completely galvanically isolated, and over long distances. This wireless PC-based data acquisition instrument offers the user more possibilities for measurement applications.
-
product
RF Architectural Shielding Products
EMI (Electromagnetic Interference) is often used interchangeably with RFI (Radio Frequency Interference). However, EMI can be any frequency of electromagnetic noise, whereas RFI is a relatively narrow range of electromagnetic noise on the EM spectrum. EMI Shielding can be used to mitigate electric and magnetic radiation across various spaces. Radio Frequency (RF) Shielding can be used to mitigate RFI with specifically designed enclosures that can block RFI. As well, RF Shielding can include application of RF Shielding paints, fabrics, and other materials.
-
product
Electromagnetic Simulation Software Suite
EMTOOLS
EMTOOLS is a computational electromagnetic (CEM) software suite comprised of 16 different software codes. ACAL (Advanced Complex Algebra Library) is an out-of-core linear system solution library, using a hyper-matrix approach to partition the problem. The AntFarm™ (Antenna Farm) toolkit analyzes the radiation and electromagnetic interference (EMI) effects of single or multiple heterogeneous RF systems. Apatch™ software is an antenna design and analysis tool that provides antenna simulation and modeling by computing the radiation and receiving pattern of an antenna or antenna array installed in an operational environment...
-
product
120W to 150W - Single Output
CUS150M Serie
*150W Convection rating (/U version)*ITE and Medical Certifications (2 x MOPP)*Class B Conducted and Radiated EMI*Suitable for Class I and II installations*Compact 2 x 4 x 1.24" footprint*Suitable for BF Rated Equipment*Operation up to 85°C Ambient
-
product
Near Field Probes 30 MHz up to 3 GHz
RF2 set
The RF2 near field probe set consists of 4 passive near field probes for measurements in the development phase of the magnetic field in the range from 30 MHz to 3 GHz on electronic assemblies. The probe heads of the RF2 set allow the step by step localization of interference sources of the RF magnetic field on assemblies. From greater distances the electromagnetic interference can be detected by RF-R 400-1 and RF-R 50-1 probes. The RF-B 3-2 and RF-U 5-2 probes with their higher resolution can more precisely detect the interference sources. Field orientation and field distribution on an electronic assembly can be detected through a trained special use of the near field probe. The near field probes are small and handy. They have a sheath current attenuation and are electrically shielded. They can be connected to a spectrum analyzer or an oscilloscope with a 50 Ω input. They do not have an internal terminating resistance.
-
product
EMI/EMC Filters And EMI Solutions
Chengdu Mengsheng Electronics Co., Ltd.
DOREXS is a company specializing in the manufacture of EMI/EMC filters. For more than a decade, it has been committed to providing cost-effective EMI/EMC filters and EMI solutions for commercial, medical, military and industrial applications. We help your equipment gain recognition for its stable and reliable functions.
-
product
EMC Testing Inductors
Electromagnetic Compatibility (EMC) testing is a somewhat unique discipline within the world of electrical product development and analysis. Electromagnetic Compatibility (EMC) testing is primarily concerned with understanding and mitigating the affects of Electromagnetic Interference (EMI).
-
product
15W to 960W - Single Output
DPP Series
*Low Cost*UL 508 Listed*Convection Cooled*Conducted and Radiated EMI, Class B*Input Transient Protection, IEC61000-4*Conforms to EN61000-3-2 (PFC)*Three year warranty
-
product
EMI/EMP Connectors
Filter connector series includes EMI/ EMP/ESD circular, ARINC, D-subminiature and micro-D connector styles. They can be combined with high energy TVS diode technology to achieve lightning and EMP transient protection. Smiths Interconnect's EMI filter connectors use multi-layer ceramic capacitor arrays together with inductive materials to realize robust, high performance low pass filter networks. Where required, transient protection can be combined with EMI /RFI filtering to provide maximum protection. The diodes as well as the EMI filter are packaged separately so the construction of the connector remains modular.
-
product
EMF Measurements/EM Measurements/Electromagnetic Radiation
Holland Shielding Systems B.V.
Electromagnetic fields cause interference in electronic devices and may affect the health of people close to where the fields are generated. It is important to recognize this at an early stage in a construction process, for instance at a future construction location or while construction is already underway, so that budgets are not exceeded. By means of field-strength measurements one can chart the existing electromagnetic fields and radiation emitted by GSM, UMTS antennas and transformer spaces, to mention a few examples. These measurements can help determine the best location in the new building for rooms where sensitive measurements are to take place, e.g. in hospitals or nano laboratories. And last but not least, field-strength measurements can detect sources of interference and can be part of a scheduled check of existing screened spaces and Faraday cages.





























