Loop Meters
-
Product
AC/DC Single Phase Digital Power Meter 100 kHz
T3PM1100
Power Meter
AC/DC Single Phase Digital Power Meter 100 kHz.
-
Product
P-Series Single Channel Power Meter
N1911A
Power Meter
30 MHz video bandwidth Single shot real time capture at 100 M sample/s per second Key Measurements: - peak, average, peak-to-average ratio, rise time, fall time and pulse width22 Predefined formats: WiMAX, DME, HSDPA, etc. One screen view for pulse measurement analysis: Auto Scale, Auto Gate, Rise/Fall Time, Duty Cycle, etc. Internal Zeroing and Calibration while connecting to the DUT Bench Vue software enabled
-
Product
Single Loop Controller
1462
-
The N4400 is a sophisticated, single loop controller which provides extensive profiling programming options for complex processes. The controller can create a profile with up to 121 segments, store up to 8 programs and configure and store extra programs on a PC.
-
Product
Recorder for non-stop(Loop)
-
You just set the desired number of the days to keep track of, and Stream MultiRec will record them uninterruptedly 24 hours a day with no human intervention. The number of tracked channels is defined by the user depending on specific requirements and the storage capacity of the video server in use.
-
Product
High Current Short Circuit Loop Impedance Meter
AMZC-310S
-
Measurement of very small short-circuit loop impedances (with resolution of 0,1mΩ) using the current of 150A under 230V, maximum 280A under 440V, or measurement using the current of 23A under 230V, maximum 42A under 440V
-
Product
Short Circuit Loop Impedance Meter
AMZC-306
-
Voltage measurement up to 750V and up to 250V with resolution 0,1V ; Measurements using Uni-Schuko adapter or test wires 1,2; 5; 10 and 20m ; Loop impedance measurement with resolution 0,01Ω and much more
-
Product
EPM Series Dual-Channel Power Meter
N1914B
Power Meter
The N1914B EPM series dual-channel average power meter provides repeatable and reliable results for bench/rack and field applications.
-
Product
Monitoring Loops
-
The Loop Sensor was designed to monitor the generated magnetic fields in radiated susceptibility tests.
-
Product
RCD Loop Line
-
Digital measuring instrument for RCD testing with Loop and Line resistance measurement also without tripping the RCD.
-
Product
Analog Optical Power Meter - PXI
Power 1500 Series
Power Meter
The Power 1500 Series analog power meter brings cost-effective test and measurement. The Power 1500 provides logarithmic analog output as well as a digital optical power meter for applications that require real-time feedback.
-
Product
Local Loop Simulator 128 Channels
458-CC-16/458-CM
-
FEATURES: Accepts 1 to 16 Line Modules; User-Friendly Interface; Multiple Configurations; Field-Upgradeable Software; One-Year Warranty/Calibration. The 458 Series 16-slot Chassis, which consists of the 458-CC chassis and one of three control modules, provides a wide variety of configurations through use of up to 16 plug-in Line Modules.
-
Product
Open Loop Current Sensor
C03 30A
-
The C03 offers efficient and precise sensor solutions for direct, alternating and pulsed currents in industrial, commercial and communication systems. It consists of three main components: an accurate, linear Hall sensor with low temperature drift, a flux collector and a transformer. It is characterized by a very low resistance and thus lowers power loss and temperature drift - for optimal performance.
-
Product
ThePoint - Loop Powered Level Switch
-
ThePoint Loop Powered two wire level switch provides a current output and has hazardous area approvals making it a good choice for most of your point level application requirements. ThePoint level sensing device offering is suitable for most temperature, pressure, and material types.
-
Product
Current Loop Expansion Kit
OP-SB85C
-
This expansion kit supports current loop communications.The kit incorporates a communications circuit with photo-coupler isolation and constant-current power supply of insulated type, thus realizing not only monitoring but also easy communications testing with passive or active current loop devices.
-
Product
Loop / PFC Testers
-
PeakTech Prüf- und Messtechnik GmbH
The PeakTech 2715 is a loop tester which is used to test the safety of electrical systems. These device measures the impedance of the short-circuit loop between the outer conductors of a circuit, whereby the probable short-circuit current is calculated. The protection of the circuit (miniature circuit breaker) must therefore trigger at a lower current than the expected short-circuit current, in order to avoid excessive heating of the lines and thus a fire risk. The PeakTech 2715 is due to its function and its robust design almost indispensable when performing new installations, but also for general checking of electrical systems, this device is the ideal companion.
-
Product
Friction Flow Loop System
-
Friction Flow Loop System is used for testing the effects of friction reducers by circulating at high rates through different pipe diameters. Friction Loop designs vary based on the application required.
-
Product
Short Circuit Loop Impedance Meter
AMZC-305
-
Loop impedance measurement with resolution 0,01Ω ; Loop impedance measurement without tripping the circuit breaker > 30mA with resolution 0,01Ω (100...440V) ; Measurements possible in installations 110/190V, 115/200V, 127/220V, 220/380V, 230/400V, 240/415V, 290/500V and 400/690V (range 100...750V)
-
Product
Dual Loop Master Controller
-
The Xcite System Master Controller provides all dual loop functions needed for accurate closed loop control and display of the static and dynamic test variables, while producing the highest electro-hydraulic frequency response. At the heart of each Xcite System is the Master Controller, a compact electronic control package which provides all of the controls and displays necessary to operate a controlled force or torque exciter system. The Xcite Master Controller is unique in that it provides electro-hydraulic excitation over a broad frequency range, unprecedented by any previous electro-hydraulic excitation system. It achieves its great frequency range through the use of sophisticated circuitry, high voltage inputs to the servovalve and compression control of the dynamic feedback variable in addition to the conventional servo control of the static loop. Static parameters such as force or displacement may be matched with dynamic control variables such as force, displacement, velocity, acceleration or strain for maximum test flexibility.
-
Product
Antenna, Active Loop
EM-6869 | 9 KHz – 50 MHz
-
The Electro-Metrics EM-6869 Active Loop Antenna is used with any receiver or spectrum analyzer with 50 ohm input and covers the frequency range of 9 kHz to 50 MHz.
-
Product
Temperature Loop Control Setup
ULP-27
-
Unitech Scales And Measurements Pvt. Ltd
Unitech’s Temperature Control Loop Setup is basically a PC based PID controller setup used for closed loop and open loop analysis of temperature process system. The setup comprises of RTD temperature Sensor. The water flows through the Rotameter and Process tank to which a heating coil is fitted. The heater is controlled by a Thirstier drive. The Thirstier drive is connected to PID controller. The manual control valve can control the water flow. The system is mounted on a tabletop model with all necessary Piping. Water at approx. 100 LPH has to be supplied to a system externally. The electronic panel comprises of ADC/DAC card with RS-232 interfaces.
-
Product
Closed Loop Hall AC/DC Current Sensor
CYHCS-SH
-
ChenYang Technologies GmbH & Co. KG
This Hall Effect current sensor is based on closed loop compensating principle and can beused for measurement of DC and AC current, pulse currents etc. The output of thetransducer reflects the real wave of the current carrying conductor.
-
Product
Dynamic Scale Deposition Loop System
-
Dynamic Scale Deposition Loop fully automated systems includes hardware and software to measure and evaluate the performance of scale inhibitors under high pressure and high temperature conditions.
-
Product
3-Dimensional Loop Antenna Van Veen
-
Loop Antenna System ( LAS )3-dimensional large loop antennadiam. 2 macc. EN 55015 / CISPR 15
-
Product
U Type Glow Wire Loop
IEC60695-2-10
-
Shenzhen Chuangxin Instruments Co., Ltd.
Thermo resistance, spare part set of Glow Wire Apparatus Acc IEC60695-2-10. Thermo resistance loop is a wire loop that is defined at a temperature and is pressed against a standardized test platelet made of plastic (or other materials) for a prescribed period of time under precise test conditions.
-
Product
Antenna, Loop
EM-6879 | 10 KHz – 30 MHz
-
The EM-6879 Loop Antenna is used for magnetic field measurements over the frequency range of 10 kHz to 30 MHz. The EM-6879 is designed for use with any 50 ohm Receiver System. The antenna has a balanced Faraday shield that reduces its response to electric fields to a vanishingly small amount so that it can produce a practically pure magnetic field response.
-
Product
Modular Breakout System for Hardware-In-Loop Simulation
-
Designed in partnership with OPAL-RT Technologies, this Modular Breakout System combines a BoB feature set with the added flexibility of an FIU. By mating the FIU chassis directly to the BoB using our plug-in modules, cabling is minimized, creating a more compact reliable design and improving signal integrity.
-
Product
Resistance Tester With Leakage Current (Loop Current)
GT00WD00ZY
-
*screen display*Double protection insulation*Non-contact measured resistance, safe, fast
-
Product
Single Loop Controller
1160+
-
The 1160+ controller is an evolved product from the West N6100. The product benefits from having more versatile features and user-friendly functionalities such as remote setpoint inputs, digital inputs, plug-in output modules, a customisable operator/HMI menu, jumperless and auto-hardware configuration, and 24VDC transmitter power supply.
-
Product
Active Loop Antenna
AL-130R
-
Also known as Magnetic Loop Antenna, the AL-130R is compliant with CISPR 16-1-4. It is ideal for emissions measurements as required by various EMC standards such as FCC 18, CISPR 11, CISPR 13, CISPR 14, CISPR 32 and many more. The built-in, low-noise preamplifier, increases overall measurement sensitivity as well as the overall signal to noise ratio. As per ANSI C63.4-2014, the use of active loop antenna for compliance testing is permitted in a non-sheilded environment ONLY if the saturation indicator is continuously monitored during the course of testing. Com-Power’s Remote Antenna Interface (RAI-100) comes in very handy for this application. It is a compact controller which can be used to enable/ disable RF measurement circuit and monitor saturation and battery low conditions remotely via a fiber optic cable up to 30 mtrs in length.
-
Product
Milliamp Calibrators & Loop Calibrators
-
Practical Instrument Electronics, Inc.
PIE has milliamp calibrators to fit your needs from the PIE 334 with the basic functions of a 4-20 milliamp calibrator to the advanced loop troubleshooting capabilities of the Model 532. And PIE milliamp calibrators are the only models with patented Loop Diagnostic Technology! All the loop calibrators have fuse-less protection, rugged design, long battery life. Calibrate in the units matching your instruments by displaying in milliamps and percent (%) of 4 to 20 milliamps.





























