Battery Charge Discharge
-
Product
PXI/PXIe Battery Simulator Module, 6-Channel, V/I Readback, Simplified Current Sink, 750 V Isolation
41-752A-911
Battery Simulator
Targeting EV, automotive, aerospace, energy storage and electric aircraft applications, the new battery simulator modules occupy a single PXI slot. These 6-channel battery simulators are capable of supplying up to 7 V and 300 mA per channel. The channels are fully isolated from ground and from each other, allowing series connection to simulate batteries in a stacked architecture.
-
Product
DC-DC Charge Pumps
-
Charge pumps – inductorless boost converters – from ams operate at up to 90% efficiency.
-
Product
Partial Discharge Detector
PXDP-II
-
The PXDP-II partial discharge meter is a portable device that performs detection and measurement of partial discharges in electrical devices or components. It records partial discharge measurements for analysis and diagnosis through the optional PC software. The PXDP-II can be used in various applications and complies with IEC 60270.
-
Product
Charge System Safety
-
Renesas' charging system safety circuits are optimized to provide a redundant safety protection to an Li-ion battery charging system by monitoring input voltage, battery voltage and charge current.
-
Product
Charge Amplifier
-
This compact Charge Amplifier has 3 signal routes.When it is used as the Charge Amplifier for the vibration analysis systemWave Stocker, all setups are possibleby the upgraded software.
-
Product
Batterie Inspektor
Battery Test Platform
By combining the most diverse hardware and software modules, Batterie Inspektor™ delivers innovative, automated, and digitalized battery testing at every stage of manufacturing. With this flexible test platform, all modules can be adapted to their respective quality requirements. Manufacturing is simplified through a scalable and standardized framework for both new projects and upgrades.
-
Product
Battery Starting & Charging System Analyze
12-2415
-
*Shown with optional 12-2416 barcode scanner*Graphical Hand-Held Tester with Thermal Printer and USB Port*Tests 12V Flooded, AGM, Gel Cell, & EFB Batteries from 100 to 2000CCA*Graphical/Symbol Based LCD display*Tests 12/24V charging and electrical systems*Stores last 70 test series with or without power*Carrying case, printing software and USB cables included*Built-in thermal printer with thermal paper (611305)*Field-Replaceable Cables (900165)
-
Product
Standard 0.95 (26.90) - 4.50 (128.00) Battery Probe
CP-2TB-12
Battery Probe
Current Rating (Amps): 5Average Probe Resistance (mOhm): 50Test Center (mil): 75Test Center (mm): 1.91Full Travel (mil): 128Full Travel (mm): 3.25Recommended Travel (mil): 118.1Recommended Travel (mm): 3.00Overall Length (mil): 472Overall Length (mm): 12.00Overall Length Remark: Overall length does not include tail.Recommended Drill Size: #53 or 1.51 mmRec. Mounting Hole Size (mil): 61Rec. Mounting Hole Size (mm): 1.55
-
Product
Electrostatic Discharge Generator
-
Beijing KeHuan Century EMC Technology Co,.LTD
Electrostatic discharge generator
-
Product
Standard 0.81 (23.00) - 4.50 (128.00) Battery Probe
CP-059-026
Battery Probe
Current Rating (Amps): 10Average Probe Resistance (mOhm): 25Test Center (mil): 100Test Center (mm): 2.54Full Travel (mil): 57Full Travel (mm): 1.45Recommended Travel (mil): 40Recommended Travel (mm): 1.00Mechanical Life (no of cyles): 100,000Overall Length (mil): 221Overall Length (mm): 5.61
-
Product
PXI/PXIe Battery Simulator Module, 2-Channel, 750 V Isolation
43-752A-003
Battery Simulator
Targeting EV, automotive, aerospace, energy storage and electric aircraft applications, the new battery simulator modules occupy a single PXI slot. These 2-channel battery simulators are capable of supplying up to 7 V and 300 mA per channel. The channels are fully isolated from ground and from each other, allowing series connection to simulate batteries in a stacked architecture.
-
Product
Standard 0.95 (26.90) - 4.50 (128.00) Battery Probe
CP-2SB-12
Battery Probe
Current Rating (Amps): 5Average Probe Resistance (mOhm): 50Test Center (mil): 75Test Center (mm): 1.91Full Travel (mil): 128Full Travel (mm): 3.25Recommended Travel (mil): 118.1Recommended Travel (mm): 3.00Overall Length (mil): 472Overall Length (mm): 12.00Overall Length Remark: Overall length does not include tail.Recommended Drill Size: #53 or 1.51 mmRec. Mounting Hole Size (mil): 61Rec. Mounting Hole Size (mm): 1.55
-
Product
Discharging Bars
-
VARIO discharge products consist of a separate AC power supply for connecting one or more Eltex discharging components. In SINGLE discharging, the voltage generation (power supply ) is integrated in the bar.
-
Product
Partial Discharge Testing Equipment
AR700
-
PD Defect Location in High-Voltage Equipment Insulation by Acoustic Sensors To act on deteriorating insulation the source of PD must be known.The insulation defects produce partial discharges, which emits electrical impulses, radiation of electromagnetic waves as well as acoustic signals.The AR700 measures acoustic signals with multiple sensors spread over the transformer. Then the software determines the failure location using the time difference of all incoming signals. Finally, these coordinates are shown in a 3D model of the transformer. AR700 device is used for measuring of acoustic signals on the external surfaces of gas-insulated breakers and substations, power transformers and other tank high-voltage equipment. The acoustic signals are caused by partial discharges in the insulation, which is the sigh of the defects.The advantage of “AR700” device is the quick installation of the acoustic PD sensors on the external surface of high-voltage equipment tank. The sensors have magnetic holder that is why there is no need to de-energize the equipment for the sensors installation. “AR700” device has 4 syn-chronic channels for acoustic signal measurement. This gives the possibility not only to find the defects in the insulation, but also to locate them. The location function of the “AR700”device is unique for acoustic devices.
-
Product
Electrostatic Discharge Generator
STT-ESD-2005
-
Beijing KeHuan Century EMC Technology Co,.LTD
The STT-ESD-2005 ESD generator meets the requirements of IEC61000-4-2 and GB/T17626.2. Its maximum ESD voltage reaches 30kV, meeting the standard's ESD voltage requirements (Level 4 air-gap discharge requires 15kV). It is also suitable for a wider range of applications and future standards. Therefore, the ESD-2005 ESD generator can be used for ESD testing of most electrical and electronic equipment, ensuring test comparability and reproducibility.
-
Product
Partial Discharge Solutions
-
From software systems to hand-held instruments, we’ve developed industry-leading technology to help you keep on top of ageing assets. Spot the warning signs, including partial discharge, to manage maintenance and make timely repairs.
-
Product
Partial Discharge Pulse Calibrator
TPK
-
Partial discharge puls calibrator TPK is a battery-powered handheld device for determining the correction factor in a Partial Discharge test circuit and to verify the Partial Discharge measurement.
-
Product
Charge Integrator Amplifiers
AD8488
-
Analog Devices’ charge integrator amplifiers convert the charge acquired by X-ray or photodiode detectors to a voltage. The channels are composed of CMOS transistors, using typical high input impedance CMOS gates. The integrators generate charge dependent voltages using a range of selectable capacitance values that accommodate a broad range of input charge values. The integrators are followed by single-ended input to differential output voltage amplifiers where offset and low frequency noise voltages are subtracted from the input voltages.
-
Product
High Voltage Discharge Rod
DSR-50K & DSR-100K
-
Standard Electric Works Co., Ltd
● For discharging and earthing for cables ● For discharging and earthing of test units● For safety purpose
-
Product
Standard 0.49 (13.89) - 2.50 (70.87) Battery Probe
CP-4L
Battery Probe
Current Rating (Amps): 10Average Probe Resistance (mOhm): 25Test Center (mil): 75Test Center (mm): 1.91Full Travel (mil): 60Full Travel (mm): 1.52Recommended Travel (mil): 40Recommended Travel (mm): 1.01Overall Length (mil): 311Overall Length (mm): 7.90Overall Length Remark: Overall length does not include tail.
-
Product
Cable Discharge Solutions
-
Cable Discharge Event, or CDE, is an electrostatic discharge event that occurs when a cable is connecting to a piece of equipment with different potential. It occurs because there is a potential differential between the charge on a cable to be connected and the equipment. It doesn't matter if the cable is charged or if the equipment is charged. It's the potential differential that causes the discharge. ESDEMC develops commercial system for CDE reliability test and evaluation.
-
Product
Expert Partial Discharge Detector
XDP-II™
-
The well-established XDP-II™ is a battery-operated portable device allowing partial discharge detection and analysis. The data is saved in its internal memory for local or further analysis on the PC-based XDP-SOFT™. Paired with the proper accessories, the XDP-II™ becomes a powerful solution for many applications such as Cable Joints and Elbows, Switchgear, Offline, Acoustic, TEV, Rotating machines, Transformer, etc…
-
Product
Battery Chargers
BAC Series
-
Battery charger BAC series is a portable and universal battery charging solution. It is primarily intended for charging Lead-Acid, Ni-Cd and Li-ion batteries from 1 V DC to 300V DC level. However, the unit can charge the string of any battery type by one of the available charge modes:IU (constant current + constant voltage)UU (constant voltage + constant voltage with a current limit)Charging modes provide a safe regulation of charging procedure and achieves fast recharge and low risk of overcharge.Variety of implemented protections, such as thermal, overcurrent, undervoltage, and overvoltage, assure the charging process will be safe for the battery and the instrument itself.A user doesn’t have to switch off the main charger in order to use BAC series charger. Just the opposite, the BAC series charger should support the main charger to speed up the process. An alternative use is to quickly recharge a battery following a discharge test.The provided display enables users to monitor all relevant information during the charging process and to adjust charging parameters and limits in real-time.The instrument offers the best power-to-weight ratio in the market, weighing only 10 kg / 22 lbs with the maximum output power of 2,7 kW.The maximum charging currents for lead-acid, Ni-Cd and Li-ion batteries, at various battery voltages, are presented in the brochure.
-
Product
Standard 0.66 (18.70) - 4.50 (128.00) Battery Probe
CP-2TB-4
Battery Probe
Current Rating (Amps): 5Average Probe Resistance (mOhm): 50Test Center (mil): 75Test Center (mm): 1.91Full Travel (mil): 39Full Travel (mm): 1.00Recommended Travel (mil): 30Recommended Travel (mm): 0.75Overall Length (mil): 158Overall Length (mm): 4.00Overall Length Remark: Overall length does not include tail.Recommended Drill Size: #53 or 1.51 mmRec. Mounting Hole Size (mil): 61Rec. Mounting Hole Size (mm): 1.55
-
Product
Battery Tester
BT-100A
-
Konstar Electric Industrial Co., Ltd
Battery tester can test the car battery whether is ok, if the battery is bad or need chanrge or bad, the tester will give you the right check reasult, then can do the right plan for the battery before work.
-
Product
Battery Simulator
G5.BAS
-
The G5.BAS series is bidirectional regenerative. It was developed specifically for the simulation of energy storage devices and batteries and is suitable for use in laboratories and on test benches. The modular and finely graded G5.BAS series is characterized by highly dynamic response times and a wide current-voltage range with an auto-ranging factor 3.
-
Product
Battery Analyzers for Stationary Battery Systems
-
Fluke Battery Analyzers are the ideal test tool for maintaining, troubleshooting and performance testing individual stationary batteries and battery banks used in critical battery back-up applications in data centers, telecom networks, power distribution systems and more. With an intuitive user interface, a compact design, and rugged construction the Fluke Battery Analyzers are designed to provide optimum performance, test results and reliability.
-
Product
Battery Charger/Discharger
BCD-3933T
-
Kongter Test & Measurement Co., Limited
Specially designed for single cell of 6V and 12V ONLY with max current of 50A. Three functions in one: charger, discharger and activator, which will facilitate your maintenance for batteries.