Current Preamplifiers
-
product
High Current Calibrator
MC151
MC151 Current calibrator is an accurate current source capable of 120 A. Typical uses include calibration of current sensors, current probes, current transformers, shunts, ammeters, DMMs or as stable current source for test and development applications. The calibrator is equipped with a built-in multimeter that can be used for simulation of programmable transconductance or current amplifier.
-
product
Split type Pulse Current Sensor
PCT-06
MULTI MEASURING INSTRUMENTS Co., Ltd.
*Through hole type pulse current sensor.*Pulse current sensor for power demand meter.
-
product
DC/AC Earth Leakage Current Measurement
FDAZCT-11L-0.4
MULTI MEASURING INSTRUMENTS Co., Ltd.
*Bipolar ±15V Power Supply.*Output ±5V at primary nominal current.*Applicable Frequency DC-18kHz.*Inside Diameter:φ11mm
-
product
Current Measurement in a Compact Design
ICD-Series
Isabellenhütte Heusler GmbH & Co. KG
The ICD series is a compact system for current measurement. The ICD-A is suitable for an application in the automotive industry due to its connector, while the ICD-C is more suitable for the design industry. The shunt-based measurement provides for a high level of accuracy and temperature compensation is also incorporated through the internal signal processing. External temperature influences are thus reduced to a minimum.
-
product
Active Input Module for Teledyne RESON TC4014 and TC4032, Hydrophones with Built-In Preamplifiers
EC6076
The EC6076 Active Input module is for the Teledyne RESON TC4014 and TC4032 hydrophones with built-in pre-amplifiers.EC6076 provides an easy interface to the hydrophones, it al-lows use of the differential output from the hydrophones ei-ther via direct feedthrough of the signal on an XLR output con-nector or via the built-in differential amplifier that converts the differential hydrophone signal into a single-ended +6dB signal on a BNC/coax out. EC6076 has a built-in rechargeable battery that provides power for the EC6076 differential amplifier and the TC4000 hydrophone.
-
product
Current Transformer
ST-12RCT
Standard Electric Works Co., Ltd
● Primary Current Rating (Amp) : 800~2000
-
product
C-Band Single Channel Pre-Amplifier EDFA (SPA)
HSA4300 (With SNMP)
Hangzhou Huatai Optic Tech. Co., Ltd.
Huatai HSA4300 series is a low noise pre-EDFA which designed specifically for single wavelength optic transmission system. It is installed in the front of optical receiver, used for improving the receiving sensitivity of the optical receiver, and extending the signal transmission distance.
-
product
High Current SMU
Source and Measurement Units (SMUs) are devices that generate voltages or currents and can measure them simultaneously using the integrated measurement units (VMU, CMU).High current SMUs operate as a regulated power source and are able to generate very high output currents as pulses.
-
product
Capacitor Leakage Current Meter
DU2316/2317
Delta United Instrument Co., Ltd.
Leackage Current range display: 0.0001uA ~ 20.00mAAutomatic or Manual trigger with CHARGE/TEST/DISCHARGE100 sets of memory, can be saved test parameter and comparator setting, easy to use.Cover up free, system firmware upgrade can be update via RS-232, easy to maintenanceHi / Lo current limit setting & PASS/FAIL judgment240*64 Graphic LCD display, can be read the reading clearly and easier.User friendly programmable interface, easy to useProvided RS-232C and Handler combinatorial interface option, to meet your needed
-
product
Primary Current Injection Testing
KAM
This substation testing device is designed to grant high current output when needed in substation commissioning activities.
-
product
Preamplifier, 100 MHz to 18 GHz
87405C
Exceptional gain (25 dB) and flatness (1.5 dB) combined with a probe-power bias connection which eliminates the need for an additional DC power supply, makes these preamplifiers the ideal choice for spectrum analyzer or stand alone applications.
-
product
Split Core Current Transformers
Application:Watt Transducer, Current Transducer, KWH Meter, Demand Meter, Power Factor Meter, Current Sensing Relays, Energy Management SystemsContinuous Thermal: Rating 1.25 at 30° C, 1.0 at 55° C Standard 5-amp secondary. Others available.
-
product
Current Probe
Vernier Software & Technology, LLC
Simplify your experimental setup with the Go Direct Current Probe. It connects wirelessly via Bluetooth® or wired via USB to your device. The wireless connection eliminates additional cables that can clutter the lab bench. Capture small currents like those produced by a magnet falling through a coil.
-
product
Clamp type AC Current Sensor/for Low Leakage Current Measurements(ZCT Series)
ZCT-18S
MULTI MEASURING INSTRUMENTS Co., Ltd.
*Best sensor for low leakage current measurements of less than 1mA.*Ultra compact size with 18mmφ jaw opening capability.*High sensitivity and least affection from external magnetic field.
-
product
High-Voltage Differential Probe, 25 MHz
N2791A
Use the N2791A 25-MHz low-cost high-voltage differential probe to make safe and accurate floating measurements with an oscilloscope. The N2791A differential probe allows conventional earth-grounded Keysight oscilloscopes to be used for floating signal measurements of up to 700 V of differential voltage and common mode voltage.
-
product
Split Type AC Current Sensor
CTF-10
MULTI MEASURING INSTRUMENTS Co., Ltd.
*For AC current and power measurements.*Wide measuring range (AC 0.1~60A).*Compliant with RoHS drective.
-
product
Clamp type AC Current Sensor/for Low Leakage Current Measurements(ZCT Series)
ZCT-22
MULTI MEASURING INSTRUMENTS Co., Ltd.
*Best sensor for leakage current measurements*Ultra compact size*AC 1mA~100A
-
product
IEC Standard Burden Sets (Current)
IEC Burden Sets
Testing and calibrating current transformers often requires standard burdens of reliable accuracy and stability, and burdens that are immune to stray fields and harmonics. These burden sets have been carefully designed to meet these requirements. They also provide the standard burdens required for the testing of current transformers for metering service, and for the testing (within the current rating provided by the sets) of current transformers for relaying applications, all as called for by IEC (International Electrotechnical Commission) Publication 185: 1987.
-
product
Current Clamp Multimeters
PeakTech Prüf- und Messtechnik GmbH
It uses a pair of jaw which allow clamping around an electrical conductor to measure the current in a conductor without the need to make physical contact unlike a normal multimeter.
-
product
Digital Volt Or Current Meter
CS1/CS2-VA
Measuring Voltage or Current for DC / AC / TRMS Accuracy: DC: +/-0.04% or AC: +/-0.1%; Display range: -19999~29999 User function, Easily programmable via the front panel. 1 relay, 1 Analogue output or RS 485 communication port in option with flexible functions. CE approved
-
product
Automotive Current Tester LCD Display
77102
This automotive current tester with LCD display, plugs directly into the fuse box and can be used on mini, standard and maxi fuse connections. Blades may get hot during use and care should be taken for 2mins whilst they cool down. Fits mini and maxi fuses. Current range 0-80AMP. Safe and easy way to check automotive current.
-
product
Bluetooth Recording Current Meter
RCM Blue
A self-recording dedicated current meter with Bluetooth for communications and data retrieval - now with the possibility to integrate a pressure sensor!The RCM Blue is a self-recording Current Meter which also measures water temperature in salt or fresh water, and a battery container with battery capacity up to 70Ah. .The Doppler Current Sensor is an upgraded version of the proven SeaGuard ZPulse sensor. The RCM Blue instrument configuration and data retrieval is done via Bluetooth which eliminates the need to open the pressure case for repeated deployments.RCM Blue has now been upgraded with the possibility to integrate a pressure sensor with a 0,01% accuracy. This simplifies your work significantly as you will know exactly where you are in the water column.
-
product
Lock-In Voltage Preamplifier
SR550
Stanford Research Systems, Inc.
The SR550 Voltage Preamplifier is designed to work with any SRS lock-in amplifier. Preamplifiers provide gain close to the experimental detector, before the signal-to-noise ratio is permanently degraded by cable capacitance and pickup
-
product
Flexible Leakage/Line Current Tester
RLM-10+
MULTI MEASURING INSTRUMENTS Co., Ltd.
●Low-pass filter equipped, it can be cut the noise which is over 150Hz frequency.●Even Coreless Coil but Least Influence from External Magnetic Field and Residual Current●Superior Flexible CT enables Leakage Current Measurement●Backlight Function useful for measurement in the dark place
-
product
High-Voltage, High Current I/O Module
Model JI-4516
The JI-4516 module is a versatile, easy-to-use device for adding high-voltage, high-current digital I/O capability to a computer system via a USB connection. The module is comprised of 8, low-side power MOSFET switches, and 8 high-voltage inputs. I/O ground isolation eliminates ground-loops and provides protection from noise and switching transients during high-current load switching. The JI-4516 is available as either a desktop unit or low-cost OEM board.
-
product
TMR Current Sensors
MultiDimension Technology Co.,Ltd.
An open-close current transducer, high sensitivity and signal-to-noise ratio TMR chips are used in the design, which based on Tunneling magneto resistance effect. The transducer has a built-in temperature compensation and nonlinear compensation circuit, which can accurately measure DC, AC and pulse current. The transducer has many benefits ,such as high precision, wide bandwidth, low power consumption, excellent isolation performance and so on. Besides, the design of open-close structure makes it easier to install and unload.
-
product
High Current Probes
The maximum continuous current rating of a spring probe is determined by its design, size, and construction. Typical probes are rated from 2 to 8 amps maximum continuously current at working travel. While this is sufficient for most board test applications, higher current applications will require a much more solid and rugged probe to withstand current capabilities of 10 to 150 amps and beyond.Another high current solution is our feed-through plunger probe line. As the name already describes, the plunger moves right through the probe and is made from a single piece, reducing the internal resistance of the probe to a minimum.
-
product
1 MHz Bandwidth Voltage Preamplifier with Bandpass Filter
EC6081 mk2 - preamplifier
The EC6081 mk2 (VP2000) is a 1MHz bandwidth voltage preamplifier with bandpass filter that is designed for uses in conjunction with piezoelectric hydrophones. VP2000 offers excellent low-noise performance over the entire frequency range; and adjustable gain selection. A range of 12 high-pass and 12 low-pass filters are available, these allow ideal band pass filter settings.
-
product
Electrolytic Capacitor Leakage Current Meter
TH2686C
Changzhou Tonghui Electronic Co., Ltd.
■ Test voltage: 0-200V, 0-500V ■ Voltage accuracy: 2% set value + 2 words ■ Measuring range: 0-30mA, 10 gears ■ Current accuracy: 2% of reading +0.5 grid
-
product
High AC Current Capacitor
LC1/LC2/LC3-RNM
Induction Heating Processing Equipment, Electric Current Welding, High Power Resonant Circuits, Motor Controls; Oscillating, Bypass, Coupling circuits, High AC Current applications, High-Frequency AC Filter and Medium Frequency Power applications.