Transfer Standards
-
Product
DC Power Source for Standard Lamp
DC502
-
DC502 is CONSTANT CURRENT DC POWER SUPPLY for standard lamp. Function and technical indexes are as follows: • output voltage 4 grades: 6V/12V/24V/50V • output current: DC 0~2.5A (adjustable) • Output current drift at full scale: ±0.05% reading value/10 mins • Monitor range of ampere meter: 0.0000A ~1.9500A, 1.950 A ~2.500A • Accuracy of ampere meter: ± (0.08% reading value + 0.02% full scale) • Max output power: 80W • Continuous working time: 8 hours • Work environment: Temperature 0℃ -25℃, humidity ≤ 85%R.H, supply source: AC220 ±10%, 50/60HZ • Holding conditions: -20~50℃ humidity < 75%R.H • Outside dimension (W×H×D): 333mm×114mm×307mm • Weight: about 8kg • Power: about 1000VA
-
Product
Standard Type Spring Probes
-
From for bare board to for ICT, we have variety of spring probes for PCB. In addition to variety of tip type and total length, we also have receptacles that match the best to spring probes. We can also attach lead wire to the receptacles.
-
Product
VXI Rubidium/GPS Frequency Standard
3352A Series
-
The Racal Instruments™ 3352A Rubidium frequency standard module and the 3352A-GPS, its GPS-disciplined companion, set a new standard for high density functionality in a single width VXI module. Using ANSI Standard M-Module building blocks, the 3352A series integrates the functions of a Rubidium oscillator and clock distribution together with an optional trigger distribution module and an optional digital I/O (DIO) module.
-
Product
Standard 0.62 (18.00) - 5.40 (153.00) Probe
LFRE-39I15-5.4
ICT/FCT Probe
Current Rating (Amps): 2Average Probe Resistance (mOhm): 50Test Center (mil): 75Test Center (mm): 1.91Full Travel (mil): 250Full Travel (mm): 6.35Recommended Travel (mil): 167Recommended Travel (mm): 4.24Mechanical Life (no of cycles): 50,000Overall Length (mil): 1,437Overall Length (mm): 36.50
-
Product
Standard Voltage 37 Pin D-Type Connector Blocks
-
The connector blocks and breakouts below are not compatible with Pickering products, however, are offered for developing a connection solution for use with other products.
-
Product
Two-Way Radio Communications and High Speed Data Transfer
Leaky Feeder System
-
Leaky Feeder systems offer clear two-way radio communication and high-speed data transfer capabilities throughout your underground complex.PBE’s Leaky Feeder System can be tailored to specific site requirements to provide the best radio coverage and data communications. This two-way radio system can provide complete communications coverage for your site, including above ground surface coverage. PBE offers design, supply, testing and commissioning of temporary and permanent communication infrastructures for underground mines, tunnels, plants and buildings. PBE provides a wide range of leaky feeder system options: conventional leaky feeder system, CMTS system, permanent radiating cable network and hybrid networks.
-
Product
LXI 50Ω Microwave Transfer Switch
60-808-410-007
-
These LXI (Ethernet-controlled) Microwave Transfer Switches are suitable for routing 50 Ω signals up to 50 GHz. With up to 16 switch banks, they are ideal for constructing complex microwave switching systems for many applications. Connection is by front panel mounted SMA. SMA 2.9 or SMA 2.4 connectors.
-
Product
LXI 50Ω Microwave Transfer Switch
60-808-210-001
-
These LXI (Ethernet-controlled) Microwave Transfer Switches are suitable for routing 50 Ω signals up to 50 GHz. With up to 16 switch banks, they are ideal for constructing complex microwave switching systems for many applications. Connection is by front panel mounted SMA. SMA 2.9 or SMA 2.4 connectors.
-
Product
PXI/PXIe Microwave Transfer Switch, Dual, 50 GHz, 50 Ω, SMA-2.4, Failsafe
42-782B-552
Switch Module
The 40-782B-552 (PXI) and 42-782B-552 (PXIe) dual failsafe transfer switches are part of our range of PXI microwave switching modules. They have a characteristic impedance of 50 Ω and a maximum operating frequency of 50 GHz. Connections are made via front panel mounted high quality SMA-2.4 coaxial connectors.
-
Product
Standard - 1.44 (41.00) - 4.50 (128.00) High Current Probe
HCP-13A
High Current Probe
Current Rating (Amps): 15Average Probe Resistance (mOhm): 25Test Center (mil): 125Test Center (mm): 3.18Full Travel (mil): 250Full Travel (mm): 6.35Recommended Travel (mil): 167Recommended Travel (mm): 4.24Mechanical Life (no of cyles): 250,000Overall Length (mil): 1,300Overall Length (mm): 33.02
-
Product
LXI 50Ω Microwave Transfer Switch
60-808-510-004
-
These LXI (Ethernet-controlled) Microwave Transfer Switches are suitable for routing 50 Ω signals up to 50 GHz. With up to 16 switch banks, they are ideal for constructing complex microwave switching systems for many applications. Connection is by front panel mounted SMA. SMA 2.9 or SMA 2.4 connectors.
-
Product
Standard 1.02 (29.00) - 4.00 (114.00) High Performance Bias Ball Probe
POGO-62I8-4-S
ICT/FCT Probe
Current Rating (Amps): 3Average Probe Resistance (mOhm): 15Test Center (mil): 50Test Center (mm): 1.27Full Travel (mil): 250Full Travel (mm): 6.35Recommended Travel (mil): 167Recommended Travel (mm): 4.24Mechanical Life (no of cycles): 500,000Overall Length (mil): 1,300Overall Length (mm): 33.02
-
Product
Standard Voltage 9 Pin D-Type Cables - Connector to Unterminated for Pickering Products
-
The connector to unterminated cable assemblies below are suitable to use with Pickering cards and modules that utilize a standard voltage 9-pin D-type connector.
-
Product
LXI 50Ω Microwave Transfer Switch
60-808-015-015
-
These LXI (Ethernet-controlled) Microwave Transfer Switches are suitable for routing 50 Ω signals up to 50 GHz. With up to 16 switch banks, they are ideal for constructing complex microwave switching systems for many applications. Connection is by front panel mounted SMA. SMA 2.9 or SMA 2.4 connectors.
-
Product
Standard Ratio Box For Calibration
ST-105
-
The ST-105 is a calibration box with standard ratios. It is used for calibration of any turn ratios measurement system. Housed in a rugged, waterproof case, it is very lightweight.
-
Product
Turbidity And Standard Meters
-
Accurately measure the cloudiness of a fluid caused by suspended particles with turbidity meters and standards from HF scientific. Our turbidity meters and standards instruments include features that simplify installation, maintenance, and data access.We offer reliable turbidity meters including an online turbidity meter, handheld turbidity meter, and benchtop turbidity meter.
-
Product
Standard 1.10 (31.00) - 3.85 (109.00)General Purpose Probe
SPA-64-8
General Purpose Probe
Current Rating (Amps): 3Average Probe Resistance (mOhm): 50Test Center (mil): 100Test Center (mm): 2.54Test Center Remark: max. test center 187 mil / 4,74 mmFull Travel (mil): 50Full Travel (mm): 1.27Recommended Travel (mil): 50Recommended Travel (mm): 1.27Mechanical Life (no of cyles): 1,000,000Overall Length (mil): 375Overall Length (mm): 9.53Overall Length Remark: Exact length depends on selected tip: Tip 1,4, 7: 0,375″; Tip 2,3: 0,365″; Tip 8: 0,385″; Tip ,9,10: 0,363″
-
Product
Single Wafer Transfer Tools
-
Dou Yee Enterprises (S) Pte Ltd
Dou Yee Enterprises Single Wafer Transfer Tools
-
Product
Standard 1.60 (45.00) - 4.50 (128.00) General Purpose Probe
EPA-3B
General Purpose Probe
Current Rating (Amps): 6Average Probe Resistance (mOhm): 35Test Center (mil): 125Test Center (mm): 3.18Full Travel (mil): 250Full Travel (mm): 6.35Recommended Travel (mil): 167Recommended Travel (mm): 4.24Mechanical Life (no of cyles): 2,000,000Overall Length (mil): 1,300Overall Length (mm): 33.02
-
Product
Radiative Transfer Equation Solver
EcoLight-S
-
EcoLight-S(ubroutine) is an extremely fast RTE (radiative transfer equation) solver developed for use as the optical component of coupled physical-biological-optical ocean ecosystem models, or as the radiative transfer forward-model core of implicit inverse models.
-
Product
Standard 1.50 (43.00) - 4.00 (113.00) High Performance Lead Free Probe
LFRE-25I35-4
ICT/FCT Probe
Current Rating (Amps): 8Average Probe Resistance (mOhm): 8Test Center (mil): 100Test Center (mm): 2.54Full Travel (mil): 250Full Travel (mm): 6.35Recommended Travel (mil): 167Recommended Travel (mm): 4.24Mechanical Life (no of cycles): 1,000,000Overall Length (mil): 1,300Overall Length (mm): 33.02
-
Product
Standard 1.08 (31.00) - 3.50 (99.00) General Purpose Probe
EPA-2T
General Purpose Probe
Current Rating (Amps): 5Average Probe Resistance (mOhm): 35Test Center (mil): 100Test Center (mm): 2.54Full Travel (mil): 160Full Travel (mm): 4.06Recommended Travel (mil): 107Recommended Travel (mm): 2.72Mechanical Life (no of cyles): 2,000,000Overall Length (mil): 970Overall Length (mm): 24.64
-
Product
Analytical Reference Materials & Standards
-
Agilent, now with former Ultra Scientific, offers a comprehensive portfolio of analytical standards, reference materials and certified reference materials for environmental, food safety, elemental analysis, instrument calibration, tuning mixes, and more.Reference materials and certified reference materials are substances that are tested to be homogenous and have fixed values of its concentrations. These standards are a critical component of your application workflow - from sample prep, instruments, columns, supplies, and services. The success of your analysis depends upon the quality of your reference material. All Agilent standard reference materials have been manufactured to the highest quality in an ISO 9001, ISO 17025 and 17034 accredited facilities to ensure the accuracy of your analyses.If you need a custom reference material, partner with us to design and develop a custom standard to your specifications.
-
Product
Additional Products: Standard Voltage 50 Pin D-Type Cables - Connector to Unterminated
-
The connector to unterminated cable assemblies below are not compatible with Pickering products, however, are offered for developing a connection solution for use with other products.
-
Product
Decade Resistance Substituter Lab Standard
HARS-LX Series
-
The HARS-LX substituter is a precision resistance source with excellent characteristics of accuracy, stability, temperature coefficient, and power coefficient. All these features serve to make it a laboratory resistance standard, exceeded in performance only by stand-alone standard resistors.
-
Product
Standard 0.62 (18.00) - 4.00 (114.00) High Performance Bias Ball Probe
POGO-1J-4
ICT/FCT Probe
Current Rating (Amps): 6Average Probe Resistance (mOhm): 10Test Center (mil): 75Test Center (mm): 1.91Full Travel (mil): 250Full Travel (mm): 6.35Recommended Travel (mil): 167Recommended Travel (mm): 4.24Mechanical Life (no of cycles): 1,000,000Overall Length (mil): 1,300Overall Length (mm): 33.02
-
Product
LXI 50Ω Microwave Transfer Switch
60-808-510-014
-
These LXI (Ethernet-controlled) Microwave Transfer Switches are suitable for routing 50 Ω signals up to 50 GHz. With up to 16 switch banks, they are ideal for constructing complex microwave switching systems for many applications. Connection is by front panel mounted SMA. SMA 2.9 or SMA 2.4 connectors.
-
Product
Standard 3.27 (93.00) - 8.13 (231.00) High Frequency Probe
K-50L
High Frequency Probe
Current Rating (Amps): 5Bandwidth @ -1dB (GHz): 4.00Return Loss @ -20dB (GHz): 1.90Nominal Impedance (Ohms): 50Test Center (mil): 550Test Center (mm): 13.97Full Travel (mil): 250Full Travel (mm): 6.35Recommended Travel (mil): 225Recommended Travel (mm): 5.72Overall Length (mil): 1,830Overall Length (mm): 46.48
-
Product
LXI 50Ω Microwave Transfer Switch
60-808-415-010
-
These LXI (Ethernet-controlled) Microwave Transfer Switches are suitable for routing 50 Ω signals up to 50 GHz. With up to 16 switch banks, they are ideal for constructing complex microwave switching systems for many applications. Connection is by front panel mounted SMA. SMA 2.9 or SMA 2.4 connectors.