Voltage References
-
product
NI-9244, 400 Vrms L-N, 800 Vrms L-L, 50 kS/s/ch, 24-Bit, 3-Phase C Series Voltage Input Module
783106-01
400 Vrms L-N, 800 Vrms L-L, 50 kS/s/ch, 24-Bit, 3-Phase C Series Voltage Input Module - The NI‑9244 performs single-ended analog input. The wide measurement range makes it ideal for high-voltage measurement applications such as phasor measurements, power metering, power quality monitoring, industrial machinery, and motor test. You can also perform transient and harmonic analysis with high-speed simultaneous sampling. The NI‑9244 offers three channels, so you can connect single‑ or three‑phase measurement configurations such as WYE and delta. You can incorporate the NI‑9244 into systems to meet standards such as IEC 61010‑1, C37.90 and C37.60, IEC 60255‑22‑(1:7), IEC 60255‑1, C37.188 Class M and P, EMC section of IEC 60870, EMC sections of IEC 61850, IEC 61000‑4‑30 Class S, and IEC 61000‑4‑7.
-
product
Acoustical Generator (STIPA Reference)
TalkBox
The TalkBox is an acoustic signal generator for speech intelligibility measurements in evacuation and announcement systems, as well as for level alignment of teleconference or other audio systems. It allows you to perform a complete end-to-end evaluation of the speech intelligibility STI from the talker’s microphone to the listener’s ears.
-
product
Reference Cells For PIV-IV Systems
NREL calibrated cell used for calibration transfer.The Abet Technologies solar reference cell is a precision instrument for the determination of solar simulator irradiance levels. The sensor is a mono-crystalline silicon solar cell having an area of2x2cm(4cm).The back of the solar cell is attached to the device in such a way that a good heat transfer to the device housing is guaranteed. Below the solar cell a Pt100 RTD temperature sensor is mounted to allow monitoring of device temperature. The device is not shunted allowing the whole IV-curve to be measured. The solar cell is protected by a high quality fused silica window, assuring spectral sensitivity over a 320 -1100 nm range.
-
product
GPS Frequency Reference
E8000
The Quartzlock E8000 GPS Frequency Reference is a breakthrough in exceptionally low cost, traceable, 1-U rack mount, calibration-free, off-air frequency & time standards. These very low cost references maintain the high frequency & time accuracy required for demanding applications. Ultra low noise option are available.
-
product
Reference Transmitter
81491A
Keysight's 81491A Reference Transmitter is designed to offer excellent eye quality for NRZ and PAM4 signals at baud-rates up to 32Gbaud and can serve as universal E/O converter. It comes in Multimode (MM) and Single-Mode (SM) flavors and includes internal lasers at 850nm (MM) or 1310&1550nm (SM). External optical input for usage with tunable laser sources is available for SM option. It is fully integrated into Keysight’s Optical Receiver Stress Test solutions to address test requirements of IEEE 802.3 10,40,100 and 400GBASE optical standards.
-
product
Reference Thermometers
Reference thermometers (standard thermometers) are, due to their excellent stability and their geometrical adaptations, ideally suited for applications in industrial laboratories. They enable easy comparative calibration in baths, in tube furnaces and in dry-well calibrators. The advantage of reference thermometers is the wide temperature range, and with this, their flexible operation. Furthermore, with their low drift, a long service life is ensured.
-
product
AC Reference Generators
SR25
Computer Conversions Corporation
The SR Series are miniature, low cost AC reference generators designed to supply 26 or 115 volt excitation to synchros or resolvers in military and industrial control applications. They accept +/-15V DC and provide up to 5VA of transformer isolated output power. These converters are packaged in PC card mounting modules 2.6”x3.1”x1”H.
-
product
Voltage Protection
Are solid state voltage sensing relays with electromechanical output contacts built in a fully draw out case format. Designed for application on AC & DC voltage systems, these relays are ideally suited to monitor power supply voltage levels wherever high accuracy and reliable, maintenance free operation is essential. All power to operate the relays is derived from the sensed input voltage therefore an auxiliary supply is not required.
-
product
Voltage Probes
In addition to EMI measurement with LISNs (Line Impedance Stabilisation Networks, Artificial Mains Networks), Probes are used for Terminal or Line voltage measurement.
-
product
Voltage Stabilizer
MS 7643
VSTAB is a voltage stabilizer, regulates the incoming supply +28V voltage into the required +15V. The electrical specifications meets MIL704 standard. Over load and short circuit protections are provided. Voltage stabilizer Module is a part of shipborne unit and it is meant for ensuring the power supply of the devices of this unit when fed from DC mains with nominal voltage of 28 V and variations of voltages from minimum 16V to maximum 32 V. The power consumption is 45 watts. The module is subjected to Qualification Tests as per MIL-STD-810G.
-
product
AC Reference Generators
SRB
Computer Conversions Corporation
The SRB Series are miniature, Bulk-head Mount, low cost AC reference generators to supply moderate power 2-115VAC excitation to Synchro's, Resolvers, LVDT's and related converters in COTS-Military and industrial applications for measurement, control, simulation and data communications.
-
product
SR Series AC Reference Supplies
Computer Conversions Corporation
The SR Series are miniature, low cost AC reference generators designed to supply 26 or 115 Volt excitation to Synchros or resolvers in military and industrial control applications. They accept +/- 15V DC and provide up to 5VA of transformer isolated output power. These converters are packaged in PC card mounting modules 2.6" x 3.1" x 1"H.
-
product
Voltage Testers
Shenzhen Everbest Machinery Industry Co.,Ltd.
Non-contact detection of 50 to 1000V ACRugged and double molded caseSuitable for outlets or against wire insulation testingFlashing red LED light indicatorBuilt-in bright flashlight with on/off buttonConvenient size with pocket clipAuto power offSystem self testUse on 50/60Hz circuitsComplete with two AA batteriesCATIII 1000VDimensions: 158 x 21mmWeight: 48g
-
product
Power Integrity Analyzer Reference Solution
The power integrity analyzer reference solution is a hardware-based solution with the Keysight Infiniium S-Series 10-Bit ADC oscilloscope and probes, including the N7020A power rail probe that lets you see the true AC power noise on your DC power line and supports up to +/- 24 V offset and the N2820A high-sensitivity current probe that can measure down to 50 uA.
-
product
TPI With Voltage
NMC''s Digital Tap Position indicator with Voltage Display, type: TX-202, is used to indicate the Tap Position of the Power Transformer with On Load Tap Changer as well as also indicates the voltage .
-
product
Voltage Testers
Electrical Receptacle Tester Instantly Displays Wiring Condition of Any Standard 3-Wire AC 110-120 OutletNeon Indicators Give Positive Indication of Current StatusCompact Unit Simply Plugs into any Standard 3 Wire/Grounded Receptacle (110–125 Volt AC Circuits)Tests for 6 Circuit Conditions: Open Ground, Open Neutral, Open Hot, Hot/Ground Reverse, Hot/Neutral Reverse & Correct WiringBlister PackedcULus ListedOrder Qty of 1 = 1 Piece
-
product
3207a GPS/GNS Frequency and Time Reference
GlobalTyme2
Precise Time and Frequency, Inc.
The ptf 3207A GlobalTyme2 GNS Receiver introduces a new level of advanced capability from a second generation, based on the highly successful ptf 3203A and ptf 3204A GlobalTyme receivers.The unit is both a frequency standard and a time standard and has been used as a precision frequency reference with low phase noise, in satellite communications applications around the world.
-
product
Reference Radiators / Comb Generators
The Spectrum Generator is a family member of the Schwarzbeck pulse generators, which are used as pulsestandard world wide. Whilst the latter one uses a bounce free relay contact to discharge a coaxial lineto the load resistor, it uses a special avalanche transistor instead of the relay contact.
-
product
Voltage Meter
МН32СМ
The mezzanine module (mezzanine) МН32СМ is designed to measure instantaneous voltage values over thirty two two-wire differential channels.
-
product
Reference DAC, Pre And Headphone Amplifier
CALLIA
Designed and manufactured in the United Kingdom, CALLIA embodies the Prism Sound uncompromising approach to audio resulting in the most accurate and detailed DAC available.
-
product
Reference Magnet
Reference magnets generate a homogeneous magnetic field in an air gap. They are mainly used to calibrate hall probes for their full scale value of output for the magnetic field strength H or the magnetic flux density B they measure. For example Gaussmeters can be calibrated by using reference magnets.
-
product
Primary Reference Source
VCH-1008C
The primary reference source VCH-1008C is designed to form highly stable signals used in digital communication networks as the first level of the hierarchy. The use of digital technologies for the formation and processing of signals allows you to realize the best stability characteristics.
-
product
sbRIO-9201, Non-Enclosed, ±10 V, 500 kS/s, 12-Bit, 8-Channel C Series Voltage Input Module
781114-01
Non-Enclosed, ±10 V, 500 kS/s, 12-Bit, 8-Channel C Series Voltage Input Module - The sbRIO‑9201 is an effective combination of channel count and speed at a low price for an economical multifunction system. In addition to the absolute protection from the isolation, the module features up to 100 V of overvoltage protection for errant signal connection or unexpected outputs to the individual channels. Non-enclosed modules are designed for OEM applications.
-
product
Reference Sources
A physical or digital document that you would refer to for more information about a topic.
-
product
Surge Voltage Generator
SSG 2100
BAUR Prüf- und Messtechnik GmbH
Cable fault location with the BAUR SSG 2100. Surge voltage generators are used for pre-location and pinpointing of high- and low-resistive as well as intermittent faults in power cables. The energy stored in a high-voltage capacitor is released at regular intervals or as DC voltage. The thus generated acoustic signal at the fault position can be recorded with a ground microphone and a universal receiver.* High surge voltage up to 32 kV* Continuously adjustable voltage* Voltage monitoring through kV meters with 3 measuring ranges* Automatic discharge unit