Thermocouple Calibrators
-
product
DC/10 MHz 67 GHz USB Thermocouple Power Sensor
U8488A
The U8480 series is Keysight's first power sensor with the capability to measure down to DC (only applicable for U8481A/85A). Now, with an expanded frequency range up to 50 and 67 GHz, the U8480 series allows you to make fast and accurate high frequency power measurements in applications ranging from PNA/MXG calibration to high volume manufacturing.
-
product
Pressure Calibrators
We offer pressure calibrators as portable and as workshop models. Pressure measurement is performed with internal and/or external pressure modules for better flexibility. Pressure measurement ranges go from vacuum up to 1000 bar (14,500 Psi). Both gauge (vacuum and positive) and absolute pressure can be measured with same modules meaning you don’t need to buy so many module for greater flexibility. Also, intrinsically safe pressure calibrators are available for use in hazardous areas.
-
product
Air Data Calibration
Fluke calibration offers digital pressure monitors, air data calibrators and laboratory standards for air data pressure range calibrations. Each of these systems feature pressure ranges, measurement units and features specific to calibrate air data test sets and RVSM compliant air data instruments. Models include 2468 Ruska and ADCS-601 DHI primary level standards; 7750i Ruska air data controller/calibrator and RPM4-AD DHI reference pressure monitor.
-
product
Dimensional Calibration
Process Instruments certifies Gage Blocks with a state-of-the-art Pratt & Whitney Gage Block Comparator. Outside and Inside Micrometers, Depth Micrometers, Height Gages, Calipers and Dial Indicators can be repaired and calibrated to manufacturers'' specs.
-
product
Transducer Calibration
When it comes to finding the perfect transducer calibration system, look no further than MB Dynamics. Our Calibration Systems offer an extensive range, from the Win475-Basic, the trusted calibration solution for the United States Air Force; to the first of its kind Win475-TS, which measures a transducer’s transverse sensitivity. No matter what your needs, you’ll find the calibration equipment that works for you.
-
product
Torque Calibrators
Torque calibrators offer the ability to check torque on a manual torque wrenches, electric and impact driven torque tools.
-
product
Labconcept Horizontal Calibration Benches By Trimos
a remarkable instrument for all measuring tasks that require extremely high accuracy.
-
product
PAT Calibration Checkboxes
Seaward's special PAT calibration checkboxes are designed to provide a fast and simple means of confirming that test readings remain effective during those working periods between formal re-calibration.
-
product
Relative Humidity Calibration Services
PST have calibration laboratories offering Relative Humidity calibrations in six locations across the globe.
-
product
Open-Short-Load RF calibration kits
Open-Short-Load RF calibration kits from Fairview Microwave are available with Type N or 7/16 DIN connectors. Type N open-short-load RF calibration kits have male or female genders, 7/16 DIN open-short-load kits are male gender. Type N open-short-load (OSL) calibration kits for RF have a minimum frequency of 0 (DC) and a maximum frequency range between 4 GHz and 6 GHz. Type N open short load kits for calibration have a maximum power handling of between 1 Watt and 2 Watts.
-
product
Uniformity Calibration Standards
Integrating sphere light sources with halogen lamps or LEDs for generating luminous fields with uniform luminance distribution. Traceable calibrations of luminance or spectral radiance in the wavelength range from 250 nm to 2500 nm.
-
product
Process Calibrators
4-20mA Process calibrators are specific equipment which, thanks to the employed modern building technology, is now part of the range of mobile devices which have become indispensable to technicians working on modern installations.
-
product
MAX31855 J-Type Thermocouple Sensor Breakout
SEN-30001-J
Breakout board for the MAX31855J digital thermocouple interface IC. Measured temperature range is -210C-1200C with known thermal characteristics and output resolution of 0.25C. This sensor supports a larger operating range (specifically in the negative range) than its predecessors, the MAX6674 and MAX6675, though it is not pin-pin compatible. This board is interfaced with a 0.1" 1x5 pin header, has a vertical mini thermocouple connector and four mounting holes for standoffs and 4-40 screws.
-
product
Multiport Calibration Assistant
S96552B
The S96552B provides a tool to flexibly create and manage calibration sets for multiport measurements. For example, two calibration sets with independent test ports can be combined as one calibration set with a greater number of test ports. The software also offers a way to re-calibrate using a certain set of test ports to refresh the calibration set.
-
product
Thermocouple Probes
sensor that measures temperature. It consists of two different types of metals, joined together at one end. When the junction of the two metals is heated or cooled, a voltage is created that can be correlated back to the temperature.
-
product
Instrument Calibration Services
Instrument Calibration ServicesCalibration is a fundamental step in the process of measurement. It ensures that the instrument used for testing accurately indicates the required measurement parameter and that the instrument is performing to its specification.
-
product
N-port Calibrated Measurements
S97551B
The S97551B software enables full multiport error correction and measurement capabilities when using multiple USB vector network analyzers
-
product
Humidity and Temperature Calibration
The most comprehensive temperature, humidity and dew-point calibration offering on the market today.
-
product
Air Pollution Multigas Calibrator
APMC-370
Dilution of gases with high accuracy and precision requires high quality MFC’s, especially for high dilution ratios and ranges. Consequently HORIBA’s APMC-370 is equipped with digital MFC’s. These MFC’s are factory calibrated, optional also with a special Polynomial Calibration. HORIBA Europe‘s APMC-370 is designed to calibrate gas analyzers manually, remotely controlled or automatically. It is installed in air pollution monitoring stations for quality assurance in the laboratory and also in the production of gas analyzers.
-
product
Calibration and Repair Services
Additel calibrations provide you with high confidence and low uncertainty for your standards. Our accredited calibration laboratory utilizes primary-level piston gauge systems and high-performance controllers to provide services for the entire Additel product line. In addition, our repair technicians which are ready to help, should you have trouble with the Additel units you own.
-
product
Calibration Software
AMETEK Sensors, Test & Calibration
Our calibration software provides an easy way to calibrate gauges, RTD´s, thermocouples, transmitters, thermoswithes, and pressure switches. Complete a full calibration from entering the details of the gauge to printing out a calibration certificate. Reduce operating time by automating calibration procedures, reduce sources of error by automatically reading and storing values from the reference, and customize certificate templates to fit your needs.
-
product
Calibrator/DVM Calibration
Measurements International Ltd.
Developed & designed by metrologists for metrologists & calibration technicians
-
product
Qualified Hermetic EGT Thermocouple Upgrade
FIT-IT & FORGET-IT Eliminate Exhaust Gas Temperature (EGT) thermocouple concerns with AMETEK's new EGT thermocouple product offering for Frame turbine applications. AMETEK has worked closely with the turbine OEM to design and engine test this thermocouple as a direct replacement and upgrade for all new and existing EGT thermocouples. The new EGT thermocouples are qualified and meet all design specifications.
-
product
Resistors for Calibration of Current Measuring Systems and Sensors/Transducers
ChenYang Technologies GmbH & Co. KG
Is designed and made according to the Standard JB/T8225-1999 for DC resistors used in laboratory and electrical engineering.By using full closed structure and automatictemperature control it ensures resistor good long-term stability and small temperaturecoefficient. This DC resistor is very suitablefor DC current measurement and calibration of current measuring systems and current sensors. The maximal measuring current is 100A with measuring accuracy of ±0.02%
-
product
Calibration Foils Sets
990
The Elcometer 990 Calibration Foil Sets are ideal for use in the laboratory, on the production line or on site.
-
product
Torque Calibration
ISO 17025 Accredited Calibration for Torque Screwdrivers, Torque Wrenches, Torque Multipliers, Torque Transducers, Torque Watches, and Torque Readout
-
product
MAX31855 K-Type Thermocouple Arduino Shield
SEN-30004-K47
Four channel MAX31855 digital thermocouple Arduino Shield. Two versions of this shield are avaliable for each thermocouple type: either 'Ch 0-3' (CS pins use Uno/Mega IO pins 7-10) or 'Ch 4-7' (CS pins use Uno/Mega IO pins 3-6), with the only difference being which set of zero-ohm resistors are populated on the board. This allows use of other SPI devices that may be 'hard coded' to specific digital pins on the Arduino, or simply stacking one of each type together to get a total of eight thermocouple channels on one Arduino. The MAX31855K supports a measured temperature range of -270C-1372C with known thermal characteristics and output resolution of 0.25C. Included thermocouple connectors are type-specific to provide proper material continuity as close to the IC as possible. The SEN-30004 is interfaced via 3 or 4-wire SPI and a high-speed level shifter is included to allow the board to plug directly into an Arduino Uno or Mega
-
product
Test Equipment Calibration
ISO:17025 AccreditedANSI Z540-1-1994 AccreditationA2LA Certificate 2374.01
-
product
Speedometer Calibrator
Hypertech’s Speedometer Calibrator can correct the speedometer and odometer for tires up to 54 inches (depending on the application), and/or non-stock rear gear ratios. This new device is engineered for consumers that want the speedometer recalibration functions of the Speedometer Calibrator without the additional expense of the other tuning features. The Speedometer Calibrator comes with a USB cable and a CD containing software to enable quick updates and upgrades over the internet. For an additional charge, the Speedometer Calibrator can be upgraded to a Speedometer Calibrator via the internet to include all the Speedometer Calibrator features available for that vehicle.
-
product
ECPR System (Electrically Calibrated Pyroelectric Radiometer)
Rs-5900
Developed in conjunction with NIST, the Rs-5900 ECPR is a ±1% absolute accuracy radiometric transfer standard for the visible to near-IR (0.25-2.0µm), with the RsIR Option extending the ±1% accuracy to >20µm. The RsP-590 Pyroelectric Probe requires no cooling and maintains ±1% accuracy from 1 µW to 100 mW. The ECPR uses an auto-nulling, electrical substitution technique that allows the instrument to be referenced against NIST electrical standards, insuring maximum accuracy and precision. Unlike most electrically calibrated radiometers, there is a direct correlation between electrical and optical heating because the same material serves as both the optical absorber and electrical heating element.





























